{"product_id":"water-quality-multiparameter-meter-for-ph-orp-conductivity-tds","title":"Water Quality Multiparameter Meter LMMP30 (pH, ORP, Conductivity, TDS)","description":"\u003cp data-start=\"271\" data-end=\"693\"\u003eWater Quality Multiparameter LMMP30 is a high-performance laboratory instrument designed for comprehensive water analysis applications including pH, ORP, conductivity, TDS, salinity, resistivity, and temperature measurement. The system combines multiple analytical functions into a single platform for accurate and efficient testing in research, environmental, pharmaceutical, industrial, and water treatment laboratories.\u003c\/p\u003e\n\u003cp data-start=\"695\" data-end=\"1010\"\u003eThe instrument supports up to 5-point push-button calibration with automatic buffer recognition for pH measurement and customizable calibration solutions for conductivity analysis. Automatic electrode diagnostics continuously monitor electrode slope and offset, helping users maintain reliable measurement accuracy.\u003c\/p\u003e\n\u003cp data-start=\"1012\" data-end=\"1285\"\u003eLMMP30 features automatic temperature compensation for highly stable and repeatable readings across different sample conditions. Users can select temperature units, compensation modes, normalization temperature, and salinity standards according to application requirements.\u003c\/p\u003e\n\u003cp data-start=\"1287\" data-end=\"1573\"\u003eThe system supports absolute and relative mV measurement for ORP analysis, along with conductivity, TDS, salinity, and resistivity testing using selectable cell constants and compensation settings. Auto endpoint detection freezes stable measured values for easier reading and recording.\u003c\/p\u003e\n\u003cp data-start=\"1575\" data-end=\"1793\"\u003eA large backlit LCD interface provides clear visualization of all parameters and operational prompts. Built-in memory stores up to 500 data sets with date and time records to support GLP-compliant laboratory workflows.\u003c\/p\u003e\n\u003cp data-start=\"1795\" data-end=\"2018\"\u003eThe LMMP30 is suitable for water treatment facilities, environmental monitoring laboratories, pharmaceutical quality control, food and beverage analysis, chemical processing, aquaculture, and academic research applications.\u003c\/p\u003e\n\u003ch3 data-start=\"2020\" data-end=\"2035\"\u003eKey Features\u003c\/h3\u003e\n\u003cp data-start=\"2037\" data-end=\"2704\"\u003epH, ORP, conductivity, TDS, salinity, resistivity, and temperature measurement\u003cbr data-start=\"2115\" data-end=\"2118\"\u003eUp to 5-point calibration with auto buffer recognition\u003cbr data-start=\"2172\" data-end=\"2175\"\u003eAutomatic temperature compensation\u003cbr data-start=\"2209\" data-end=\"2212\"\u003eAutomatic endpoint detection for stable readings\u003cbr data-start=\"2260\" data-end=\"2263\"\u003eAbsolute and relative mV ORP measurement\u003cbr data-start=\"2303\" data-end=\"2306\"\u003eSelectable conductivity compensation modes\u003cbr data-start=\"2348\" data-end=\"2351\"\u003eSalinity measurement in PSU or seawater standards\u003cbr data-start=\"2400\" data-end=\"2403\"\u003eAutomatic electrode diagnosis with slope and offset display\u003cbr data-start=\"2462\" data-end=\"2465\"\u003eLarge LCD display with operational guidance\u003cbr data-start=\"2508\" data-end=\"2511\"\u003eMemory storage for up to 500 data sets\u003cbr data-start=\"2549\" data-end=\"2552\"\u003eBuilt-in real-time clock with date and time stamping\u003cbr data-start=\"2604\" data-end=\"2607\"\u003eSelectable temperature units in °C and °F\u003cbr data-start=\"2648\" data-end=\"2651\"\u003eSuitable for laboratory and industrial water analysis\u003c\/p\u003e\n\u003ch3 data-start=\"2706\" data-end=\"2733\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"2735\" data-end=\"4334\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"2735\" data-end=\"2764\"\u003e\n\u003ctr data-start=\"2735\" data-end=\"2764\"\u003e\n\u003cth data-start=\"2735\" data-end=\"2747\" data-col-size=\"sm\" class=\"\"\u003eParameter\u003c\/th\u003e\n\u003cth data-start=\"2747\" data-end=\"2764\" data-col-size=\"md\" class=\"\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"2779\" data-end=\"4334\"\u003e\n\u003ctr data-start=\"2779\" data-end=\"2813\"\u003e\n\u003ctd data-start=\"2779\" data-end=\"2790\" data-col-size=\"sm\"\u003epH Range\u003c\/td\u003e\n\u003ctd data-start=\"2790\" data-end=\"2813\" data-col-size=\"md\"\u003e-2.000 to 20.000 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2814\" data-end=\"2853\"\u003e\n\u003ctd data-start=\"2814\" data-end=\"2830\" data-col-size=\"sm\"\u003epH Resolution\u003c\/td\u003e\n\u003ctd data-start=\"2830\" data-end=\"2853\" data-col-size=\"md\"\u003e0.001, 0.01, 0.1 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2854\" data-end=\"2881\"\u003e\n\u003ctd data-start=\"2854\" data-end=\"2868\" data-col-size=\"sm\"\u003epH Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"2868\" data-end=\"2881\" data-col-size=\"md\"\u003e±0.002 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2882\" data-end=\"2924\"\u003e\n\u003ctd data-start=\"2882\" data-end=\"2906\" data-col-size=\"sm\"\u003epH Calibration Points\u003c\/td\u003e\n\u003ctd data-start=\"2906\" data-end=\"2924\" data-col-size=\"md\"\u003eUp to 5 Points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2925\" data-end=\"2972\"\u003e\n\u003ctd data-start=\"2925\" data-end=\"2945\" data-col-size=\"sm\"\u003epH Buffer Options\u003c\/td\u003e\n\u003ctd data-start=\"2945\" data-end=\"2972\" data-col-size=\"md\"\u003eUSA, NIST, User Defined\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2973\" data-end=\"3002\"\u003e\n\u003ctd data-start=\"2973\" data-end=\"2985\" data-col-size=\"sm\"\u003eORP Range\u003c\/td\u003e\n\u003ctd data-start=\"2985\" data-end=\"3002\" data-col-size=\"md\"\u003e0 to ±1999 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3003\" data-end=\"3034\"\u003e\n\u003ctd data-start=\"3003\" data-end=\"3020\" data-col-size=\"sm\"\u003eORP Resolution\u003c\/td\u003e\n\u003ctd data-start=\"3020\" data-end=\"3034\" data-col-size=\"md\"\u003e0.1 \/ 1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3035\" data-end=\"3061\"\u003e\n\u003ctd data-start=\"3035\" data-end=\"3050\" data-col-size=\"sm\"\u003eORP Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"3050\" data-end=\"3061\" data-col-size=\"md\"\u003e±0.2 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3062\" data-end=\"3115\"\u003e\n\u003ctd data-start=\"3062\" data-end=\"3085\" data-col-size=\"sm\"\u003eORP Measurement Mode\u003c\/td\u003e\n\u003ctd data-start=\"3085\" data-end=\"3115\" data-col-size=\"md\"\u003eAbsolute mV or Relative mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3116\" data-end=\"3152\"\u003e\n\u003ctd data-start=\"3116\" data-end=\"3137\" data-col-size=\"sm\"\u003eConductivity Range\u003c\/td\u003e\n\u003ctd data-start=\"3137\" data-end=\"3152\" data-col-size=\"md\"\u003e0–200 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3153\" data-end=\"3197\"\u003e\n\u003ctd data-start=\"3153\" data-end=\"3179\" data-col-size=\"sm\"\u003eConductivity Resolution\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3179\" data-end=\"3197\"\u003e0.01 \/ 0.1 \/ 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3198\" data-end=\"3242\"\u003e\n\u003ctd data-start=\"3198\" data-end=\"3222\" data-col-size=\"sm\"\u003eConductivity Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"3222\" data-end=\"3242\" data-col-size=\"md\"\u003e±0.5% Full Scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3243\" data-end=\"3289\"\u003e\n\u003ctd data-start=\"3243\" data-end=\"3259\" data-col-size=\"sm\"\u003eCell Constant\u003c\/td\u003e\n\u003ctd data-start=\"3259\" data-end=\"3289\" data-col-size=\"md\"\u003e0.01 \/ 1 \/ 10 User Defined\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3290\" data-end=\"3336\"\u003e\n\u003ctd data-start=\"3290\" data-end=\"3316\" data-col-size=\"sm\"\u003eTemperature Coefficient\u003c\/td\u003e\n\u003ctd data-start=\"3316\" data-end=\"3336\" data-col-size=\"md\"\u003e0.0–10.0% per °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3337\" data-end=\"3389\"\u003e\n\u003ctd data-start=\"3337\" data-end=\"3371\" data-col-size=\"sm\"\u003eConductivity Calibration Points\u003c\/td\u003e\n\u003ctd data-start=\"3371\" data-end=\"3389\" data-col-size=\"md\"\u003eUp to 5 Points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3390\" data-end=\"3474\"\u003e\n\u003ctd data-start=\"3390\" data-end=\"3414\" data-col-size=\"sm\"\u003eCalibration Solutions\u003c\/td\u003e\n\u003ctd data-start=\"3414\" data-end=\"3474\" data-col-size=\"md\"\u003e10 µS\/cm, 84 µS\/cm, 1413 µS\/cm, 12.88 mS\/cm, 111.8 µS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3475\" data-end=\"3520\"\u003e\n\u003ctd data-start=\"3475\" data-end=\"3496\" data-col-size=\"sm\"\u003eCompensation Modes\u003c\/td\u003e\n\u003ctd data-start=\"3496\" data-end=\"3520\" data-col-size=\"md\"\u003eLinear or Pure Water\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3521\" data-end=\"3545\"\u003e\n\u003ctd data-start=\"3521\" data-end=\"3533\" data-col-size=\"sm\"\u003eTDS Range\u003c\/td\u003e\n\u003ctd data-start=\"3533\" data-end=\"3545\" data-col-size=\"md\"\u003e0–10 ppt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3546\" data-end=\"3579\"\u003e\n\u003ctd data-start=\"3546\" data-end=\"3561\" data-col-size=\"sm\"\u003eTDS Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"3561\" data-end=\"3579\" data-col-size=\"md\"\u003e±1% Full Scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3580\" data-end=\"3604\"\u003e\n\u003ctd data-start=\"3580\" data-end=\"3593\" data-col-size=\"sm\"\u003eTDS Factor\u003c\/td\u003e\n\u003ctd data-start=\"3593\" data-end=\"3604\" data-col-size=\"md\"\u003e0.0–1.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3605\" data-end=\"3634\"\u003e\n\u003ctd data-start=\"3605\" data-end=\"3622\" data-col-size=\"sm\"\u003eSalinity Range\u003c\/td\u003e\n\u003ctd data-start=\"3622\" data-end=\"3634\" data-col-size=\"md\"\u003e0–80 ppt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3635\" data-end=\"3673\"\u003e\n\u003ctd data-start=\"3635\" data-end=\"3655\" data-col-size=\"sm\"\u003eSalinity Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"3655\" data-end=\"3673\" data-col-size=\"md\"\u003e±1% Full Scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3674\" data-end=\"3739\"\u003e\n\u003ctd data-start=\"3674\" data-end=\"3690\" data-col-size=\"sm\"\u003eSalinity Mode\u003c\/td\u003e\n\u003ctd data-start=\"3690\" data-end=\"3739\" data-col-size=\"md\"\u003ePractical Salinity (PSU) or Seawater Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3740\" data-end=\"3772\"\u003e\n\u003ctd data-start=\"3740\" data-end=\"3760\" data-col-size=\"sm\"\u003eResistivity Range\u003c\/td\u003e\n\u003ctd data-start=\"3760\" data-end=\"3772\" data-col-size=\"md\"\u003e0–100 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3773\" data-end=\"3816\"\u003e\n\u003ctd data-start=\"3773\" data-end=\"3798\" data-col-size=\"sm\"\u003eResistivity Resolution\u003c\/td\u003e\n\u003ctd data-start=\"3798\" data-end=\"3816\" data-col-size=\"md\"\u003e1 \/ 0.1 \/ 0.01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3817\" data-end=\"3858\"\u003e\n\u003ctd data-start=\"3817\" data-end=\"3840\" data-col-size=\"sm\"\u003eResistivity Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"3840\" data-end=\"3858\" data-col-size=\"md\"\u003e±1% Full Scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3859\" data-end=\"3890\"\u003e\n\u003ctd data-start=\"3859\" data-end=\"3879\" data-col-size=\"sm\"\u003eTemperature Range\u003c\/td\u003e\n\u003ctd data-start=\"3879\" data-end=\"3890\" data-col-size=\"md\"\u003e0–100°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3891\" data-end=\"3941\"\u003e\n\u003ctd data-start=\"3891\" data-end=\"3918\" data-col-size=\"sm\"\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd data-start=\"3918\" data-end=\"3941\" data-col-size=\"md\"\u003eAutomatic or Manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3942\" data-end=\"3975\"\u003e\n\u003ctd data-start=\"3942\" data-end=\"3965\" data-col-size=\"sm\"\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3965\" data-end=\"3975\"\u003e±0.5°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3976\" data-end=\"4020\"\u003e\n\u003ctd data-start=\"3976\" data-end=\"3996\" data-col-size=\"sm\"\u003eAuto-Off Function\u003c\/td\u003e\n\u003ctd data-start=\"3996\" data-end=\"4020\" data-col-size=\"md\"\u003e10 \/ 20 \/ 30 Minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4021\" data-end=\"4057\"\u003e\n\u003ctd data-start=\"4021\" data-end=\"4050\" data-col-size=\"sm\"\u003eReset \u0026amp; Auto Hold Function\u003c\/td\u003e\n\u003ctd data-start=\"4050\" data-end=\"4057\" data-col-size=\"md\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4058\" data-end=\"4097\"\u003e\n\u003ctd data-start=\"4058\" data-end=\"4080\" data-col-size=\"sm\"\u003eElectrode Diagnosis\u003c\/td\u003e\n\u003ctd data-start=\"4080\" data-end=\"4097\" data-col-size=\"md\"\u003eSlope, Offset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4098\" data-end=\"4148\"\u003e\n\u003ctd data-start=\"4098\" data-end=\"4121\" data-col-size=\"sm\"\u003eStability Conditions\u003c\/td\u003e\n\u003ctd data-start=\"4121\" data-end=\"4148\" data-col-size=\"md\"\u003eHigh or Low, Selectable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4149\" data-end=\"4192\"\u003e\n\u003ctd data-start=\"4149\" data-end=\"4176\" data-col-size=\"sm\"\u003eCalibration Due Reminder\u003c\/td\u003e\n\u003ctd data-start=\"4176\" data-end=\"4192\" data-col-size=\"md\"\u003e1 to 30 Days\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4193\" data-end=\"4236\"\u003e\n\u003ctd data-start=\"4193\" data-end=\"4202\" data-col-size=\"sm\"\u003eMemory\u003c\/td\u003e\n\u003ctd data-start=\"4202\" data-end=\"4236\" data-col-size=\"md\"\u003e500 Data Sets with Date \u0026amp; Time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4237\" data-end=\"4272\"\u003e\n\u003ctd data-start=\"4237\" data-end=\"4249\" data-col-size=\"sm\"\u003eConnector\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"4249\" data-end=\"4272\"\u003eBNC 6-Pin Connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4273\" data-end=\"4316\"\u003e\n\u003ctd data-start=\"4273\" data-end=\"4294\" data-col-size=\"sm\"\u003eDimensions (L×W×H)\u003c\/td\u003e\n\u003ctd data-start=\"4294\" data-end=\"4316\" data-col-size=\"md\"\u003e310 × 250 × 190 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4317\" data-end=\"4334\"\u003e\n\u003ctd data-start=\"4317\" data-end=\"4326\" data-col-size=\"sm\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-start=\"4326\" data-end=\"4334\" data-col-size=\"md\"\u003e2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 data-start=\"4336\" data-end=\"4351\"\u003eApplications\u003c\/h3\u003e\n\u003cp data-start=\"4353\" data-end=\"4635\"\u003eWater and wastewater analysis\u003cbr data-start=\"4382\" data-end=\"4385\"\u003eEnvironmental monitoring laboratories\u003cbr data-start=\"4422\" data-end=\"4425\"\u003ePharmaceutical and chemical testing\u003cbr data-start=\"4460\" data-end=\"4463\"\u003eRO and purified water systems\u003cbr data-start=\"4492\" data-end=\"4495\"\u003eFood and beverage quality control\u003cbr data-start=\"4528\" data-end=\"4531\"\u003eAquaculture and seawater testing\u003cbr data-start=\"4563\" data-end=\"4566\"\u003eIndustrial process monitoring\u003cbr data-start=\"4595\" data-end=\"4598\"\u003eEducational and research laboratories\u003c\/p\u003e","brand":"Labman","offers":[{"title":"Default Title","offer_id":49968489038061,"sku":null,"price":50000.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5672\/6765\/files\/LMMP30.webp?v=1778961608","url":"https:\/\/www.biotronscientific.com\/products\/water-quality-multiparameter-meter-for-ph-orp-conductivity-tds","provider":"BIOTRON","version":"1.0","type":"link"}