{"product_id":"water-quality-multiparameter-meter-for-ph-conductivity-do-ion","title":"Water Quality Multiparameter Meter LMMP32 (pH, Conductivity, DO, Ion)","description":"\u003cp data-start=\"253\" data-end=\"676\"\u003eWater Quality Multiparameter LMMP32 is a high-precision laboratory instrument designed for comprehensive water analysis applications including pH, ORP, ion concentration, dissolved oxygen, conductivity, TDS, salinity, resistivity, and temperature measurement. The system combines multiple analytical functions into a single platform for environmental, pharmaceutical, industrial, research, and water treatment laboratories.\u003c\/p\u003e\n\u003cp data-start=\"678\" data-end=\"965\"\u003eThe instrument supports up to 5-point pH calibration with automatic buffer recognition and customizable calibration standards. Automatic electrode diagnostics continuously monitor electrode slope and offset, helping users maintain accurate and reliable measurements throughout operation.\u003c\/p\u003e\n\u003cp data-start=\"967\" data-end=\"1288\"\u003eLMMP32 provides advanced conductivity and TDS analysis with selectable compensation modes, cell constants, temperature coefficients, and normalization temperature settings. The instrument also supports dissolved oxygen measurement with pressure correction and selectable calibration modes for highly accurate DO analysis.\u003c\/p\u003e\n\u003cp data-start=\"1290\" data-end=\"1566\"\u003eThe multiparameter system offers ion concentration analysis compatible with ion selective electrodes, making it suitable for specialized laboratory testing applications. Automatic temperature compensation ensures stable and repeatable results across varying sample conditions.\u003c\/p\u003e\n\u003cp data-start=\"1568\" data-end=\"1886\"\u003eA large backlit LCD interface displays operational prompts and measured parameters clearly for improved usability. The system includes automatic endpoint detection, auto hold functionality, calibration reminders, and memory storage for up to 500 data sets with date and time records to support GLP-compliant workflows.\u003c\/p\u003e\n\u003cp data-start=\"1888\" data-end=\"2104\"\u003eLMMP32 is suitable for water quality laboratories, environmental monitoring, pharmaceutical analysis, wastewater treatment, aquaculture, food processing, educational institutions, and industrial process applications.\u003c\/p\u003e\n\u003ch3 data-start=\"2106\" data-end=\"2121\"\u003eKey Features\u003c\/h3\u003e\n\u003cp data-start=\"2123\" data-end=\"2824\"\u003epH, ORP, ion, conductivity, TDS, salinity, resistivity, DO, and temperature measurement\u003cbr data-start=\"2210\" data-end=\"2213\"\u003eUp to 5-point pH calibration with auto buffer recognition\u003cbr data-start=\"2270\" data-end=\"2273\"\u003eDissolved oxygen measurement with pressure correction\u003cbr data-start=\"2326\" data-end=\"2329\"\u003eIon analysis using ion selective electrodes\u003cbr data-start=\"2372\" data-end=\"2375\"\u003eAutomatic temperature compensation\u003cbr data-start=\"2409\" data-end=\"2412\"\u003eAutomatic endpoint detection and auto hold function\u003cbr data-start=\"2463\" data-end=\"2466\"\u003eAutomatic electrode diagnosis with slope and offset display\u003cbr data-start=\"2525\" data-end=\"2528\"\u003eSelectable conductivity compensation modes\u003cbr data-start=\"2570\" data-end=\"2573\"\u003eSalinity measurement in PSU or seawater standards\u003cbr data-start=\"2622\" data-end=\"2625\"\u003eLarge backlit LCD display with operational guidance\u003cbr data-start=\"2676\" data-end=\"2679\"\u003eMemory storage for up to 500 data sets\u003cbr data-start=\"2717\" data-end=\"2720\"\u003eCalibration due reminder and stability selection\u003cbr data-start=\"2768\" data-end=\"2771\"\u003eSuitable for laboratory and industrial water analysis\u003c\/p\u003e\n\u003ch3 data-start=\"2826\" data-end=\"2853\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"2855\" data-end=\"4744\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"2855\" data-end=\"2884\"\u003e\n\u003ctr data-start=\"2855\" data-end=\"2884\"\u003e\n\u003cth data-start=\"2855\" data-end=\"2867\" data-col-size=\"sm\" class=\"\"\u003eParameter\u003c\/th\u003e\n\u003cth data-start=\"2867\" data-end=\"2884\" data-col-size=\"md\" class=\"\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"2899\" data-end=\"4744\"\u003e\n\u003ctr data-start=\"2899\" data-end=\"2933\"\u003e\n\u003ctd data-start=\"2899\" data-end=\"2910\" data-col-size=\"sm\"\u003epH Range\u003c\/td\u003e\n\u003ctd data-start=\"2910\" data-end=\"2933\" data-col-size=\"md\"\u003e-2.000 to 20.000 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2934\" data-end=\"2973\"\u003e\n\u003ctd data-start=\"2934\" data-end=\"2950\" data-col-size=\"sm\"\u003epH Resolution\u003c\/td\u003e\n\u003ctd data-start=\"2950\" data-end=\"2973\" data-col-size=\"md\"\u003e0.001, 0.01, 0.1 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2974\" data-end=\"3001\"\u003e\n\u003ctd data-start=\"2974\" data-end=\"2988\" data-col-size=\"sm\"\u003epH Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"2988\" data-end=\"3001\" data-col-size=\"md\"\u003e±0.002 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3002\" data-end=\"3044\"\u003e\n\u003ctd data-start=\"3002\" data-end=\"3026\" data-col-size=\"sm\"\u003epH Calibration Points\u003c\/td\u003e\n\u003ctd data-start=\"3026\" data-end=\"3044\" data-col-size=\"md\"\u003eUp to 5 Points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3045\" data-end=\"3097\"\u003e\n\u003ctd data-start=\"3045\" data-end=\"3065\" data-col-size=\"sm\"\u003epH Buffer Options\u003c\/td\u003e\n\u003ctd data-start=\"3065\" data-end=\"3097\" data-col-size=\"md\"\u003eUSA, NIST, DIN, User Defined\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3098\" data-end=\"3127\"\u003e\n\u003ctd data-start=\"3098\" data-end=\"3110\" data-col-size=\"sm\"\u003eORP Range\u003c\/td\u003e\n\u003ctd data-start=\"3110\" data-end=\"3127\" data-col-size=\"md\"\u003e0 to ±1999 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3128\" data-end=\"3159\"\u003e\n\u003ctd data-start=\"3128\" data-end=\"3145\" data-col-size=\"sm\"\u003eORP Resolution\u003c\/td\u003e\n\u003ctd data-start=\"3145\" data-end=\"3159\" data-col-size=\"md\"\u003e0.1 \/ 1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3160\" data-end=\"3186\"\u003e\n\u003ctd data-start=\"3160\" data-end=\"3175\" data-col-size=\"sm\"\u003eORP Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"3175\" data-end=\"3186\" data-col-size=\"md\"\u003e±0.2 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3187\" data-end=\"3216\"\u003e\n\u003ctd data-start=\"3187\" data-end=\"3199\" data-col-size=\"sm\"\u003eIon Range\u003c\/td\u003e\n\u003ctd data-start=\"3199\" data-end=\"3216\" data-col-size=\"md\"\u003e0.00 to 19999\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3217\" data-end=\"3254\"\u003e\n\u003ctd data-start=\"3217\" data-end=\"3234\" data-col-size=\"sm\"\u003eIon Resolution\u003c\/td\u003e\n\u003ctd data-start=\"3234\" data-end=\"3254\" data-col-size=\"md\"\u003e0.001, 0.01, 0.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3255\" data-end=\"3295\"\u003e\n\u003ctd data-start=\"3255\" data-end=\"3270\" data-col-size=\"sm\"\u003eIon Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"3270\" data-end=\"3295\" data-col-size=\"md\"\u003e±0.5%, ±1% Full Scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3296\" data-end=\"3332\"\u003e\n\u003ctd data-start=\"3296\" data-end=\"3317\" data-col-size=\"sm\"\u003eConductivity Range\u003c\/td\u003e\n\u003ctd data-start=\"3317\" data-end=\"3332\" data-col-size=\"md\"\u003e0–200 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3333\" data-end=\"3377\"\u003e\n\u003ctd data-start=\"3333\" data-end=\"3359\" data-col-size=\"sm\"\u003eConductivity Resolution\u003c\/td\u003e\n\u003ctd data-start=\"3359\" data-end=\"3377\" data-col-size=\"md\"\u003e0.01 \/ 0.1 \/ 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3378\" data-end=\"3422\"\u003e\n\u003ctd data-start=\"3378\" data-end=\"3402\" data-col-size=\"sm\"\u003eConductivity Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"3402\" data-end=\"3422\" data-col-size=\"md\"\u003e±0.5% Full Scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3423\" data-end=\"3468\"\u003e\n\u003ctd data-start=\"3423\" data-end=\"3439\" data-col-size=\"sm\"\u003eCell Constant\u003c\/td\u003e\n\u003ctd data-start=\"3439\" data-end=\"3468\" data-col-size=\"md\"\u003e0.1 \/ 1 \/ 10 User Defined\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3469\" data-end=\"3515\"\u003e\n\u003ctd data-start=\"3469\" data-end=\"3495\" data-col-size=\"sm\"\u003eTemperature Coefficient\u003c\/td\u003e\n\u003ctd data-start=\"3495\" data-end=\"3515\" data-col-size=\"md\"\u003e0.0–10.0% per °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3516\" data-end=\"3568\"\u003e\n\u003ctd data-start=\"3516\" data-end=\"3550\" data-col-size=\"sm\"\u003eConductivity Calibration Points\u003c\/td\u003e\n\u003ctd data-start=\"3550\" data-end=\"3568\" data-col-size=\"md\"\u003eUp to 5 Points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3569\" data-end=\"3653\"\u003e\n\u003ctd data-start=\"3569\" data-end=\"3593\" data-col-size=\"sm\"\u003eCalibration Solutions\u003c\/td\u003e\n\u003ctd data-start=\"3593\" data-end=\"3653\" data-col-size=\"md\"\u003e10 µS\/cm, 84 µS\/cm, 1413 µS\/cm, 12.88 mS\/cm, 111.8 µS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3654\" data-end=\"3699\"\u003e\n\u003ctd data-start=\"3654\" data-end=\"3675\" data-col-size=\"sm\"\u003eCompensation Modes\u003c\/td\u003e\n\u003ctd data-start=\"3675\" data-end=\"3699\" data-col-size=\"md\"\u003eLinear or Pure Water\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3700\" data-end=\"3724\"\u003e\n\u003ctd data-start=\"3700\" data-end=\"3712\" data-col-size=\"sm\"\u003eTDS Range\u003c\/td\u003e\n\u003ctd data-start=\"3712\" data-end=\"3724\" data-col-size=\"md\"\u003e0–10 ppt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3725\" data-end=\"3760\"\u003e\n\u003ctd data-start=\"3725\" data-end=\"3742\" data-col-size=\"sm\"\u003eTDS Resolution\u003c\/td\u003e\n\u003ctd data-start=\"3742\" data-end=\"3760\" data-col-size=\"md\"\u003e0.01 \/ 0.1 \/ 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3761\" data-end=\"3794\"\u003e\n\u003ctd data-start=\"3761\" data-end=\"3776\" data-col-size=\"sm\"\u003eTDS Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"3776\" data-end=\"3794\" data-col-size=\"md\"\u003e±1% Full Scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3795\" data-end=\"3819\"\u003e\n\u003ctd data-start=\"3795\" data-end=\"3808\" data-col-size=\"sm\"\u003eTDS Factor\u003c\/td\u003e\n\u003ctd data-start=\"3808\" data-end=\"3819\" data-col-size=\"md\"\u003e0.0–1.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3820\" data-end=\"3849\"\u003e\n\u003ctd data-start=\"3820\" data-end=\"3837\" data-col-size=\"sm\"\u003eSalinity Range\u003c\/td\u003e\n\u003ctd data-start=\"3837\" data-end=\"3849\" data-col-size=\"md\"\u003e0–80 ppt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3850\" data-end=\"3888\"\u003e\n\u003ctd data-start=\"3850\" data-end=\"3870\" data-col-size=\"sm\"\u003eSalinity Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"3870\" data-end=\"3888\" data-col-size=\"md\"\u003e±1% Full Scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3889\" data-end=\"3954\"\u003e\n\u003ctd data-start=\"3889\" data-end=\"3905\" data-col-size=\"sm\"\u003eSalinity Mode\u003c\/td\u003e\n\u003ctd data-start=\"3905\" data-end=\"3954\" data-col-size=\"md\"\u003ePractical Salinity (PSU) or Seawater Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3955\" data-end=\"3987\"\u003e\n\u003ctd data-start=\"3955\" data-end=\"3975\" data-col-size=\"sm\"\u003eResistivity Range\u003c\/td\u003e\n\u003ctd data-start=\"3975\" data-end=\"3987\" data-col-size=\"md\"\u003e0–100 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3988\" data-end=\"4031\"\u003e\n\u003ctd data-start=\"3988\" data-end=\"4013\" data-col-size=\"sm\"\u003eResistivity Resolution\u003c\/td\u003e\n\u003ctd data-start=\"4013\" data-end=\"4031\" data-col-size=\"md\"\u003e1 \/ 0.1 \/ 0.01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4032\" data-end=\"4073\"\u003e\n\u003ctd data-start=\"4032\" data-end=\"4055\" data-col-size=\"sm\"\u003eResistivity Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"4055\" data-end=\"4073\" data-col-size=\"md\"\u003e±1% Full Scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4074\" data-end=\"4107\"\u003e\n\u003ctd data-start=\"4074\" data-end=\"4085\" data-col-size=\"sm\"\u003eDO Range\u003c\/td\u003e\n\u003ctd data-start=\"4085\" data-end=\"4107\" data-col-size=\"md\"\u003e0.00 to 20.00 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4108\" data-end=\"4147\"\u003e\n\u003ctd data-start=\"4108\" data-end=\"4130\" data-col-size=\"sm\"\u003eDO Saturation Range\u003c\/td\u003e\n\u003ctd data-start=\"4130\" data-end=\"4147\" data-col-size=\"md\"\u003e0.0 to 200.0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4148\" data-end=\"4178\"\u003e\n\u003ctd data-start=\"4148\" data-end=\"4164\" data-col-size=\"sm\"\u003eDO Resolution\u003c\/td\u003e\n\u003ctd data-start=\"4164\" data-end=\"4178\" data-col-size=\"md\"\u003e0.01 \/ 0.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4179\" data-end=\"4206\"\u003e\n\u003ctd data-start=\"4179\" data-end=\"4193\" data-col-size=\"sm\"\u003eDO Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"4193\" data-end=\"4206\" data-col-size=\"md\"\u003e±0.2 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4207\" data-end=\"4241\"\u003e\n\u003ctd data-start=\"4207\" data-end=\"4224\" data-col-size=\"sm\"\u003eDO Calibration\u003c\/td\u003e\n\u003ctd data-start=\"4224\" data-end=\"4241\" data-col-size=\"md\"\u003e1 or 2 Points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4242\" data-end=\"4285\"\u003e\n\u003ctd data-start=\"4242\" data-end=\"4264\" data-col-size=\"sm\"\u003ePressure Correction\u003c\/td\u003e\n\u003ctd data-start=\"4264\" data-end=\"4285\" data-col-size=\"md\"\u003e60.0 to 112.5 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4286\" data-end=\"4317\"\u003e\n\u003ctd data-start=\"4286\" data-end=\"4306\" data-col-size=\"sm\"\u003eTemperature Range\u003c\/td\u003e\n\u003ctd data-start=\"4306\" data-end=\"4317\" data-col-size=\"md\"\u003e0–100°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4318\" data-end=\"4368\"\u003e\n\u003ctd data-start=\"4318\" data-end=\"4345\" data-col-size=\"sm\"\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd data-start=\"4345\" data-end=\"4368\" data-col-size=\"md\"\u003eAutomatic or Manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4369\" data-end=\"4402\"\u003e\n\u003ctd data-start=\"4369\" data-end=\"4392\" data-col-size=\"sm\"\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"4392\" data-end=\"4402\" data-col-size=\"md\"\u003e±0.5°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4403\" data-end=\"4430\"\u003e\n\u003ctd data-start=\"4403\" data-end=\"4423\" data-col-size=\"sm\"\u003eAuto-Off Function\u003c\/td\u003e\n\u003ctd data-start=\"4423\" data-end=\"4430\" data-col-size=\"md\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4431\" data-end=\"4467\"\u003e\n\u003ctd data-start=\"4431\" data-end=\"4460\" data-col-size=\"sm\"\u003eReset \u0026amp; Auto Hold Function\u003c\/td\u003e\n\u003ctd data-start=\"4460\" data-end=\"4467\" data-col-size=\"md\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4468\" data-end=\"4507\"\u003e\n\u003ctd data-start=\"4468\" data-end=\"4490\" data-col-size=\"sm\"\u003eElectrode Diagnosis\u003c\/td\u003e\n\u003ctd data-start=\"4490\" data-end=\"4507\" data-col-size=\"md\"\u003eSlope, Offset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4508\" data-end=\"4558\"\u003e\n\u003ctd data-start=\"4508\" data-end=\"4531\" data-col-size=\"sm\"\u003eStability Conditions\u003c\/td\u003e\n\u003ctd data-start=\"4531\" data-end=\"4558\" data-col-size=\"md\"\u003eHigh or Low, Selectable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4559\" data-end=\"4602\"\u003e\n\u003ctd data-start=\"4559\" data-end=\"4586\" data-col-size=\"sm\"\u003eCalibration Due Reminder\u003c\/td\u003e\n\u003ctd data-start=\"4586\" data-end=\"4602\" data-col-size=\"md\"\u003e1 to 30 Days\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4603\" data-end=\"4646\"\u003e\n\u003ctd data-start=\"4603\" data-end=\"4612\" data-col-size=\"sm\"\u003eMemory\u003c\/td\u003e\n\u003ctd data-start=\"4612\" data-end=\"4646\" data-col-size=\"md\"\u003e500 Data Sets with Date \u0026amp; Time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4647\" data-end=\"4682\"\u003e\n\u003ctd data-start=\"4647\" data-end=\"4659\" data-col-size=\"sm\"\u003eConnector\u003c\/td\u003e\n\u003ctd data-start=\"4659\" data-end=\"4682\" data-col-size=\"md\"\u003eBNC 6-Pin Connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4683\" data-end=\"4726\"\u003e\n\u003ctd data-start=\"4683\" data-end=\"4704\" data-col-size=\"sm\"\u003eDimensions (L×W×H)\u003c\/td\u003e\n\u003ctd data-start=\"4704\" data-end=\"4726\" data-col-size=\"md\"\u003e310 × 250 × 190 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4727\" data-end=\"4744\"\u003e\n\u003ctd data-start=\"4727\" data-end=\"4736\" data-col-size=\"sm\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-start=\"4736\" data-end=\"4744\" data-col-size=\"md\"\u003e2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 data-start=\"4746\" data-end=\"4761\"\u003eApplications\u003c\/h3\u003e\n\u003cp data-start=\"4763\" data-end=\"5054\"\u003eWater quality and wastewater testing\u003cbr data-start=\"4799\" data-end=\"4802\"\u003eEnvironmental monitoring laboratories\u003cbr data-start=\"4839\" data-end=\"4842\"\u003ePharmaceutical and chemical analysis\u003cbr data-start=\"4878\" data-end=\"4881\"\u003eAquaculture and seawater testing\u003cbr data-start=\"4913\" data-end=\"4916\"\u003eIndustrial process monitoring\u003cbr data-start=\"4945\" data-end=\"4948\"\u003eFood and beverage quality control\u003cbr data-start=\"4981\" data-end=\"4984\"\u003eResearch and educational laboratories\u003cbr data-start=\"5021\" data-end=\"5024\"\u003eRO and purified water analysis\u003c\/p\u003e","brand":"Labman","offers":[{"title":"Default Title","offer_id":49968493068525,"sku":null,"price":68000.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5672\/6765\/files\/LMMP32_2.webp?v=1778961662","url":"https:\/\/www.biotronscientific.com\/products\/water-quality-multiparameter-meter-for-ph-conductivity-do-ion","provider":"BIOTRON","version":"1.0","type":"link"}