{"product_id":"visible-spectrophotometer-lmspv325-325-1000-nm","title":"Visible Spectrophotometer LMSPV325 (325–1000 nm)","description":"\u003cp data-start=\"266\" data-end=\"530\"\u003eThe LMSPV325 Visible Spectrophotometer is designed for routine analytical applications in the visible wavelength range from 325 to 1000 nm. It uses a single beam optical system with a 1200 lines\/mm grating to provide stable and consistent photometric measurements.\u003c\/p\u003e\n\u003cp data-start=\"532\" data-end=\"793\"\u003eThe instrument features automatic wavelength setting, allowing users to quickly select required wavelengths with minimal operational error. It supports standard curve generation, enabling quantitative analysis and determination of unknown sample concentrations.\u003c\/p\u003e\n\u003cp data-start=\"795\" data-end=\"1039\"\u003eThe system provides multiple result display capability, showing wavelength, absorbance, and transmittance simultaneously, with memory storage for up to 200 results. A compact LCD interface ensures clear data visualization and ease of operation.\u003c\/p\u003e\n\u003cp data-start=\"1041\" data-end=\"1329\"\u003eEquipped with a tungsten lamp and silicon photodiode detector, the instrument delivers reliable performance across the visible spectrum. A 4-position cuvette holder allows efficient sample handling, while USB connectivity enables data transfer to external systems and printer integration.\u003c\/p\u003e\n\u003cp data-start=\"1331\" data-end=\"1479\"\u003eThe LMSPV325 is suitable for laboratories requiring a cost-effective solution for routine visible range analysis without the need for UV capability.\u003c\/p\u003e\n\u003ch3 data-start=\"1481\" data-end=\"1498\"\u003eKey Features\u003c\/h3\u003e\n\u003cp data-start=\"1499\" data-end=\"1904\"\u003eSingle beam optical system with stable performance\u003cbr data-start=\"1549\" data-end=\"1552\"\u003eVisible wavelength range from 325 to 1000 nm\u003cbr data-start=\"1596\" data-end=\"1599\"\u003eAutomatic wavelength setting\u003cbr data-start=\"1627\" data-end=\"1630\"\u003eStandard curve and quantitative analysis capability\u003cbr data-start=\"1681\" data-end=\"1684\"\u003eMultiple parameter display with memory storage\u003cbr data-start=\"1730\" data-end=\"1733\"\u003eLCD screen for clear data visualization\u003cbr data-start=\"1772\" data-end=\"1775\"\u003e4-position cuvette holder\u003cbr data-start=\"1800\" data-end=\"1803\"\u003eUSB and printer connectivity\u003cbr data-start=\"1831\" data-end=\"1834\"\u003eReliable tungsten lamp light source\u003cbr data-start=\"1869\" data-end=\"1872\"\u003eCompact and easy-to-use design\u003c\/p\u003e\n\u003ch3 data-start=\"1906\" data-end=\"1935\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"1937\" data-end=\"2717\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"1937\" data-end=\"1961\"\u003e\n\u003ctr data-start=\"1937\" data-end=\"1961\"\u003e\n\u003cth data-start=\"1937\" data-end=\"1949\" data-col-size=\"sm\" class=\"\"\u003eParameter\u003c\/th\u003e\n\u003cth data-start=\"1949\" data-end=\"1961\" data-col-size=\"sm\" class=\"\"\u003eLMSPV325\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"1986\" data-end=\"2717\"\u003e\n\u003ctr data-start=\"1986\" data-end=\"2003\"\u003e\n\u003ctd data-start=\"1986\" data-end=\"1993\" data-col-size=\"sm\"\u003eMake\u003c\/td\u003e\n\u003ctd data-start=\"1993\" data-end=\"2003\" data-col-size=\"sm\"\u003eLABMAN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2004\" data-end=\"2059\"\u003e\n\u003ctd data-start=\"2004\" data-end=\"2021\" data-col-size=\"sm\"\u003eOptical System\u003c\/td\u003e\n\u003ctd data-start=\"2021\" data-end=\"2059\" data-col-size=\"sm\"\u003eSingle Beam, Grating 1200 lines\/mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2060\" data-end=\"2093\"\u003e\n\u003ctd data-start=\"2060\" data-end=\"2071\" data-col-size=\"sm\"\u003eDetector\u003c\/td\u003e\n\u003ctd data-start=\"2071\" data-end=\"2093\" data-col-size=\"sm\"\u003eSilicon Photodiode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2094\" data-end=\"2128\"\u003e\n\u003ctd data-start=\"2094\" data-end=\"2113\" data-col-size=\"sm\"\u003eWavelength Range\u003c\/td\u003e\n\u003ctd data-start=\"2113\" data-end=\"2128\" data-col-size=\"sm\"\u003e325–1000 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2129\" data-end=\"2149\"\u003e\n\u003ctd data-start=\"2129\" data-end=\"2141\" data-col-size=\"sm\"\u003eBandwidth\u003c\/td\u003e\n\u003ctd data-start=\"2141\" data-end=\"2149\" data-col-size=\"sm\"\u003e4 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2150\" data-end=\"2181\"\u003e\n\u003ctd data-start=\"2150\" data-end=\"2172\" data-col-size=\"sm\"\u003eWavelength Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"2172\" data-end=\"2181\" data-col-size=\"sm\"\u003e±1 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2182\" data-end=\"2220\"\u003e\n\u003ctd data-start=\"2182\" data-end=\"2209\" data-col-size=\"sm\"\u003eWavelength Repeatability\u003c\/td\u003e\n\u003ctd data-start=\"2209\" data-end=\"2220\" data-col-size=\"sm\"\u003e±0.5 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2221\" data-end=\"2255\"\u003e\n\u003ctd data-start=\"2221\" data-end=\"2242\" data-col-size=\"sm\"\u003eWavelength Setting\u003c\/td\u003e\n\u003ctd data-start=\"2242\" data-end=\"2255\" data-col-size=\"sm\"\u003eAutomatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2256\" data-end=\"2296\"\u003e\n\u003ctd data-start=\"2256\" data-end=\"2276\" data-col-size=\"sm\"\u003ePhotometric Range\u003c\/td\u003e\n\u003ctd data-start=\"2276\" data-end=\"2296\" data-col-size=\"sm\"\u003e-0.3–3A, 0–200%T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2297\" data-end=\"2330\"\u003e\n\u003ctd data-start=\"2297\" data-end=\"2320\" data-col-size=\"sm\"\u003ePhotometric Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"2320\" data-end=\"2330\" data-col-size=\"sm\"\u003e±0.5%T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2331\" data-end=\"2369\"\u003e\n\u003ctd data-start=\"2331\" data-end=\"2359\" data-col-size=\"sm\"\u003ePhotometric Repeatability\u003c\/td\u003e\n\u003ctd data-start=\"2359\" data-end=\"2369\" data-col-size=\"sm\"\u003e±0.3%T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2370\" data-end=\"2403\"\u003e\n\u003ctd data-start=\"2370\" data-end=\"2389\" data-col-size=\"sm\"\u003ePhotometric Mode\u003c\/td\u003e\n\u003ctd data-start=\"2389\" data-end=\"2403\" data-col-size=\"sm\"\u003eT, A, C, F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2404\" data-end=\"2441\"\u003e\n\u003ctd data-start=\"2404\" data-end=\"2416\" data-col-size=\"sm\"\u003eStability\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2416\" data-end=\"2441\"\u003e±0.002 Abs\/h @ 500 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2442\" data-end=\"2466\"\u003e\n\u003ctd data-start=\"2442\" data-end=\"2456\" data-col-size=\"sm\"\u003eStray Light\u003c\/td\u003e\n\u003ctd data-start=\"2456\" data-end=\"2466\" data-col-size=\"sm\"\u003e≤0.3%T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2467\" data-end=\"2499\"\u003e\n\u003ctd data-start=\"2467\" data-end=\"2482\" data-col-size=\"sm\"\u003eLight Source\u003c\/td\u003e\n\u003ctd data-start=\"2482\" data-end=\"2499\" data-col-size=\"sm\"\u003eTungsten Lamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2500\" data-end=\"2524\"\u003e\n\u003ctd data-start=\"2500\" data-end=\"2510\" data-col-size=\"sm\"\u003eDisplay\u003c\/td\u003e\n\u003ctd data-start=\"2510\" data-end=\"2524\" data-col-size=\"sm\"\u003eLCD (2.5\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2525\" data-end=\"2574\"\u003e\n\u003ctd data-start=\"2525\" data-end=\"2539\" data-col-size=\"sm\"\u003eCell Holder\u003c\/td\u003e\n\u003ctd data-start=\"2539\" data-end=\"2574\" data-col-size=\"sm\"\u003e4-position 10 mm cuvette holder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2575\" data-end=\"2617\"\u003e\n\u003ctd data-start=\"2575\" data-end=\"2589\" data-col-size=\"sm\"\u003eData Output\u003c\/td\u003e\n\u003ctd data-start=\"2589\" data-end=\"2617\" data-col-size=\"sm\"\u003eUSB \u0026amp; Parallel (Printer)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2618\" data-end=\"2654\"\u003e\n\u003ctd data-start=\"2618\" data-end=\"2633\" data-col-size=\"sm\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd data-start=\"2633\" data-end=\"2654\" data-col-size=\"sm\"\u003eAC 220V \/ 50–60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2655\" data-end=\"2698\"\u003e\n\u003ctd data-start=\"2655\" data-end=\"2676\" data-col-size=\"sm\"\u003eDimensions (L×W×H)\u003c\/td\u003e\n\u003ctd data-start=\"2676\" data-end=\"2698\" data-col-size=\"sm\"\u003e565 × 435 × 305 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2699\" data-end=\"2717\"\u003e\n\u003ctd data-start=\"2699\" data-end=\"2708\" data-col-size=\"sm\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-start=\"2708\" data-end=\"2717\" data-col-size=\"sm\"\u003e11 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 data-start=\"2719\" data-end=\"2736\"\u003eApplications\u003c\/h3\u003e\n\u003cp data-start=\"2737\" data-end=\"2901\"\u003eRoutine laboratory testing\u003cbr data-start=\"2763\" data-end=\"2766\"\u003eEducational and academic laboratories\u003cbr data-start=\"2803\" data-end=\"2806\"\u003eFood and beverage analysis\u003cbr data-start=\"2832\" data-end=\"2835\"\u003eChemical testing in visible range\u003cbr data-start=\"2868\" data-end=\"2871\"\u003eQuality control applications\u003c\/p\u003e","brand":"Labman","offers":[{"title":"Default Title","offer_id":49929416278253,"sku":null,"price":68000.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5672\/6765\/files\/LMSPUV325.jpg?v=1778916379","url":"https:\/\/www.biotronscientific.com\/products\/visible-spectrophotometer-lmspv325-325-1000-nm","provider":"BIOTRON","version":"1.0","type":"link"}