{"product_id":"visible-spectrophotometer-lmspv320-325-1000-nm","title":"Visible Spectrophotometer LMSPV320 (325–1000 nm)","description":"\u003cp data-end=\"579\" data-start=\"271\"\u003eThe LMSPV320 Visible Spectrophotometer is a compact and cost-effective analytical instrument designed for routine measurements in the visible spectrum (325–1000 nm). It operates on a single beam optical system with a 1200 lines\/mm grating monochromator, ensuring good spectral resolution and low stray light.\u003c\/p\u003e\n\u003cp data-end=\"900\" data-start=\"581\"\u003eThis model features microprocessor-controlled operation with auto zero and auto 100% transmittance calibration, simplifying daily workflows and reducing operator error. The instrument displays absorbance, transmittance, concentration, and coefficient values directly on its LCD screen, allowing flexible analytical use.\u003c\/p\u003e\n\u003cp data-end=\"1208\" data-start=\"902\"\u003eUnlike higher-end models, the LMSPV320 uses\u003cspan\u003e \u003c\/span\u003e\u003cstrong data-end=\"975\" data-start=\"946\"\u003emanual wavelength setting\u003c\/strong\u003e, making it suitable for standard lab testing where full automation is not required. The system is equipped with a tungsten halogen lamp and silicon photodiode detector, providing consistent and reliable results in the visible range.\u003c\/p\u003e\n\u003cp data-end=\"1460\" data-start=\"1210\"\u003eThe instrument includes USB connectivity for PC integration (optional software) and a parallel port for direct printer output. Its compact footprint and robust design make it ideal for educational labs, QC environments, and routine chemical analysis.\u003c\/p\u003e\n\u003ch3 data-end=\"1479\" data-start=\"1462\"\u003eKey Features\u003c\/h3\u003e\n\u003cp data-end=\"1915\" data-start=\"1480\"\u003eMicroprocessor-controlled with auto zero \u0026amp; 100%T calibration\u003cbr data-end=\"1543\" data-start=\"1540\"\u003eSingle beam optical system with grating monochromator\u003cbr data-end=\"1599\" data-start=\"1596\"\u003eVisible range: 325–1000 nm\u003cbr data-end=\"1628\" data-start=\"1625\"\u003eManual wavelength selection via control knob\u003cbr data-end=\"1675\" data-start=\"1672\"\u003eLCD display for multiple measurement modes\u003cbr data-end=\"1720\" data-start=\"1717\"\u003eMeasures Absorbance, Transmittance, Concentration, Coefficient\u003cbr data-end=\"1785\" data-start=\"1782\"\u003eLow stray light and stable performance\u003cbr data-end=\"1826\" data-start=\"1823\"\u003eUSB data output and printer connectivity\u003cbr data-end=\"1869\" data-start=\"1866\"\u003eCompact design with large sample compartment\u003c\/p\u003e\n\u003ch3 data-end=\"1946\" data-start=\"1917\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\" data-end=\"2674\" data-start=\"1948\"\u003e\n\u003cthead data-end=\"1972\" data-start=\"1948\"\u003e\n\u003ctr data-end=\"1972\" data-start=\"1948\"\u003e\n\u003cth class=\"\" data-col-size=\"sm\" data-end=\"1960\" data-start=\"1948\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"\" data-col-size=\"sm\" data-end=\"1972\" data-start=\"1960\"\u003eLMSPV320\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-end=\"2674\" data-start=\"1997\"\u003e\n\u003ctr data-end=\"2014\" data-start=\"1997\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2004\" data-start=\"1997\"\u003eMake\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2014\" data-start=\"2004\"\u003eLABMAN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2070\" data-start=\"2015\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2032\" data-start=\"2015\"\u003eOptical System\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2070\" data-start=\"2032\"\u003eSingle Beam, Grating 1200 lines\/mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2104\" data-start=\"2071\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2082\" data-start=\"2071\"\u003eDetector\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2104\" data-start=\"2082\"\u003eSilicon Photodiode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2145\" data-start=\"2105\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2120\" data-start=\"2105\"\u003eLight Source\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2145\" data-start=\"2120\"\u003eTungsten Halogen Lamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2180\" data-start=\"2146\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2165\" data-start=\"2146\"\u003eWavelength Range\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2180\" data-start=\"2165\"\u003e325–1000 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2210\" data-start=\"2181\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2202\" data-start=\"2181\"\u003eSpectral Bandwidth\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2210\" data-start=\"2202\"\u003e4 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2242\" data-start=\"2211\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2233\" data-start=\"2211\"\u003eWavelength Accuracy\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2242\" data-start=\"2233\"\u003e±2 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2279\" data-start=\"2243\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2270\" data-start=\"2243\"\u003eWavelength Repeatability\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2279\" data-start=\"2270\"\u003e±1 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2311\" data-start=\"2280\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2301\" data-start=\"2280\"\u003eWavelength Setting\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2311\" data-start=\"2301\"\u003eManual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2352\" data-start=\"2312\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2332\" data-start=\"2312\"\u003ePhotometric Range\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2352\" data-start=\"2332\"\u003e-0.3–3A, 0–200%T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2386\" data-start=\"2353\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2376\" data-start=\"2353\"\u003ePhotometric Accuracy\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2386\" data-start=\"2376\"\u003e±0.5%T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2425\" data-start=\"2387\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2415\" data-start=\"2387\"\u003ePhotometric Repeatability\u003c\/td\u003e\n\u003ctd data-end=\"2425\" data-start=\"2415\" data-col-size=\"sm\"\u003e±0.3%T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2459\" data-start=\"2426\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2445\" data-start=\"2426\"\u003ePhotometric Mode\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2459\" data-start=\"2445\"\u003eT, A, C, F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2484\" data-start=\"2460\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2474\" data-start=\"2460\"\u003eStray Light\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2484\" data-start=\"2474\"\u003e≤0.3%T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2513\" data-start=\"2485\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2497\" data-start=\"2485\"\u003eStability\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2513\" data-start=\"2497\"\u003e±0.002 Abs\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2531\" data-start=\"2514\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2524\" data-start=\"2514\"\u003eDisplay\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2531\" data-start=\"2524\"\u003eLCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2574\" data-start=\"2532\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2541\" data-start=\"2532\"\u003eOutput\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2574\" data-start=\"2541\"\u003eUSB \u0026amp; Parallel Port (Printer)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2611\" data-start=\"2575\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2590\" data-start=\"2575\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2611\" data-start=\"2590\"\u003eAC 220V \/ 50–60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2655\" data-start=\"2612\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2633\" data-start=\"2612\"\u003eDimensions (L×W×H)\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2655\" data-start=\"2633\"\u003e575 × 450 × 300 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2674\" data-start=\"2656\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2665\" data-start=\"2656\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2674\" data-start=\"2665\"\u003e11 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 data-end=\"2693\" data-start=\"2676\"\u003eApplications\u003c\/h3\u003e\n\u003cp data-end=\"2861\" data-start=\"2694\"\u003eRoutine chemical analysis\u003cbr data-end=\"2722\" data-start=\"2719\"\u003eEducational and teaching laboratories\u003cbr data-end=\"2762\" data-start=\"2759\"\u003eWater and environmental testing\u003cbr data-end=\"2796\" data-start=\"2793\"\u003eFood \u0026amp; beverage quality control\u003cbr data-end=\"2830\" data-start=\"2827\"\u003eBasic pharmaceutical analysis\u003c\/p\u003e","brand":"Labman","offers":[{"title":"Default Title","offer_id":49929424994541,"sku":null,"price":45000.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5672\/6765\/files\/LMSPUV320.jpg?v=1778916441","url":"https:\/\/www.biotronscientific.com\/products\/visible-spectrophotometer-lmspv320-325-1000-nm","provider":"BIOTRON","version":"1.0","type":"link"}