{"product_id":"turbidity-meter-lmtb200-4-5-tft-display-tss-measurement-mode","title":"Turbidity Meter LMTB200 (4.5\" TFT Display, TSS Measurement Mode)","description":"\u003cp data-start=\"261\" data-end=\"594\"\u003eTurbidity Meter LMTB200 is a precision laboratory instrument designed for accurate turbidity and total suspended solids (TSS) measurement in water and wastewater analysis applications. The system combines advanced optical detection with multi-point calibration capability to deliver stable and reliable turbidity measurement results.\u003c\/p\u003e\n\u003cp data-start=\"596\" data-end=\"848\"\u003eThe instrument supports turbidity measurement from 1 to 2000 NTU with selectable turbidity units including NTU, FNU, EBC, and ASBC. A built-in TSS conversion mode enables accurate suspended solids analysis for industrial and environmental applications.\u003c\/p\u003e\n\u003cp data-start=\"850\" data-end=\"1121\"\u003eLMTB200 features a 4.5-inch TFT display with user-friendly menu navigation and operational guidance for simplified testing procedures. The system supports 2 to 7-point calibration using Formazin standards to improve measurement accuracy across different turbidity ranges.\u003c\/p\u003e\n\u003cp data-start=\"1123\" data-end=\"1384\"\u003eAn infrared-emitting diode operating at 850 nm combined with a silicon photodiode detector ensures stable optical performance with low stray light interference. Continuous measurement mode allows indexing and matching of sample vials for improved repeatability.\u003c\/p\u003e\n\u003cp data-start=\"1386\" data-end=\"1580\"\u003eThe meter includes password protection, hold functionality, automatic reset options, and internal memory capable of storing up to 200 data sets for laboratory record management and traceability.\u003c\/p\u003e\n\u003cp data-start=\"1582\" data-end=\"1795\"\u003eLMTB200 is suitable for industrial wastewater plants, municipal water treatment facilities, environmental laboratories, food and beverage testing, academic research, and industrial process monitoring applications.\u003c\/p\u003e\n\u003ch3 data-start=\"1797\" data-end=\"1812\"\u003eKey Features\u003c\/h3\u003e\n\u003cp data-start=\"1814\" data-end=\"2376\"\u003eTurbidity and TSS measurement capability\u003cbr data-start=\"1854\" data-end=\"1857\"\u003eMeasurement range from 1 to 2000 NTU\u003cbr data-start=\"1893\" data-end=\"1896\"\u003eSelectable turbidity units including NTU, FNU, EBC, and ASBC\u003cbr data-start=\"1956\" data-end=\"1959\"\u003e2 to 7-point calibration using Formazin standards\u003cbr data-start=\"2008\" data-end=\"2011\"\u003e4.5-inch TFT display with menu-based operation\u003cbr data-start=\"2057\" data-end=\"2060\"\u003eInfrared LED light source at 850 nm\u003cbr data-start=\"2095\" data-end=\"2098\"\u003eSilicon photodiode detector for stable measurement\u003cbr data-start=\"2148\" data-end=\"2151\"\u003eContinuous measurement mode for vial indexing\u003cbr data-start=\"2196\" data-end=\"2199\"\u003ePassword protection for calibration and settings\u003cbr data-start=\"2247\" data-end=\"2250\"\u003eMemory storage for up to 200 data sets\u003cbr data-start=\"2288\" data-end=\"2291\"\u003eLow stray light optical system\u003cbr data-start=\"2321\" data-end=\"2324\"\u003eSuitable for laboratory and industrial water testing\u003c\/p\u003e\n\u003ch3 data-start=\"2378\" data-end=\"2405\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"2407\" data-end=\"3198\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"2407\" data-end=\"2436\"\u003e\n\u003ctr data-start=\"2407\" data-end=\"2436\"\u003e\n\u003cth data-start=\"2407\" data-end=\"2419\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth data-start=\"2419\" data-end=\"2436\" data-col-size=\"md\" class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"2451\" data-end=\"3198\"\u003e\n\u003ctr data-start=\"2451\" data-end=\"2485\"\u003e\n\u003ctd data-start=\"2451\" data-end=\"2471\" data-col-size=\"sm\"\u003eMeasurement Range\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2471\" data-end=\"2485\"\u003e1–2000 NTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2486\" data-end=\"2556\"\u003e\n\u003ctd data-start=\"2486\" data-end=\"2499\" data-col-size=\"sm\"\u003eResolution\u003c\/td\u003e\n\u003ctd data-start=\"2499\" data-end=\"2556\" data-col-size=\"md\"\u003e0.01 (1–100 NTU), 0.1 (100–999 NTU), 1 (999–2000 NTU)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2557\" data-end=\"2575\"\u003e\n\u003ctd data-start=\"2557\" data-end=\"2568\" data-col-size=\"sm\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2568\" data-end=\"2575\"\u003e±5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2576\" data-end=\"2614\"\u003e\n\u003ctd data-start=\"2576\" data-end=\"2597\" data-col-size=\"sm\"\u003eCalibration Points\u003c\/td\u003e\n\u003ctd data-start=\"2597\" data-end=\"2614\" data-col-size=\"md\"\u003e2 to 7 Points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2615\" data-end=\"2683\"\u003e\n\u003ctd data-start=\"2615\" data-end=\"2639\" data-col-size=\"sm\"\u003eCalibration Standards\u003c\/td\u003e\n\u003ctd data-start=\"2639\" data-end=\"2683\" data-col-size=\"md\"\u003e0.02, 10, 200, 500, 1000, 1500, 2000 NTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2684\" data-end=\"2734\"\u003e\n\u003ctd data-start=\"2684\" data-end=\"2696\" data-col-size=\"sm\"\u003eTSS Range\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2696\" data-end=\"2734\"\u003eDepending on TSS Conversion Factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2735\" data-end=\"2763\"\u003e\n\u003ctd data-start=\"2735\" data-end=\"2752\" data-col-size=\"sm\"\u003eTSS Resolution\u003c\/td\u003e\n\u003ctd data-start=\"2752\" data-end=\"2763\" data-col-size=\"md\"\u003e0.0 \/ 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2764\" data-end=\"2797\"\u003e\n\u003ctd data-start=\"2764\" data-end=\"2779\" data-col-size=\"sm\"\u003eTSS Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"2779\" data-end=\"2797\" data-col-size=\"md\"\u003e±3% of Reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2798\" data-end=\"2849\"\u003e\n\u003ctd data-start=\"2798\" data-end=\"2813\" data-col-size=\"sm\"\u003eLight Source\u003c\/td\u003e\n\u003ctd data-start=\"2813\" data-end=\"2849\" data-col-size=\"md\"\u003eInfrared Emitting Diode (850 nm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2850\" data-end=\"2883\"\u003e\n\u003ctd data-start=\"2850\" data-end=\"2861\" data-col-size=\"sm\"\u003eDetector\u003c\/td\u003e\n\u003ctd data-start=\"2861\" data-end=\"2883\" data-col-size=\"md\"\u003eSilicon Photodiode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2884\" data-end=\"2911\"\u003e\n\u003ctd data-start=\"2884\" data-end=\"2898\" data-col-size=\"sm\"\u003eStray Light\u003c\/td\u003e\n\u003ctd data-start=\"2898\" data-end=\"2911\" data-col-size=\"md\"\u003e\u0026lt;0.02 NTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2912\" data-end=\"2954\"\u003e\n\u003ctd data-start=\"2912\" data-end=\"2927\" data-col-size=\"sm\"\u003eSample Vials\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2927\" data-end=\"2954\"\u003e60 (H) × 25 mm Diameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2955\" data-end=\"2987\"\u003e\n\u003ctd data-start=\"2955\" data-end=\"2964\" data-col-size=\"sm\"\u003eMemory\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2964\" data-end=\"2987\"\u003eUp to 200 Data Sets\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2988\" data-end=\"3022\"\u003e\n\u003ctd data-start=\"2988\" data-end=\"2998\" data-col-size=\"sm\"\u003eDisplay\u003c\/td\u003e\n\u003ctd data-start=\"2998\" data-end=\"3022\" data-col-size=\"md\"\u003e4.5-inch TFT Display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3023\" data-end=\"3052\"\u003e\n\u003ctd data-start=\"3023\" data-end=\"3045\" data-col-size=\"sm\"\u003ePassword Protection\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3045\" data-end=\"3052\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3053\" data-end=\"3087\"\u003e\n\u003ctd data-start=\"3053\" data-end=\"3077\" data-col-size=\"sm\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3077\" data-end=\"3087\"\u003e0–50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3088\" data-end=\"3136\"\u003e\n\u003ctd data-start=\"3088\" data-end=\"3103\" data-col-size=\"sm\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd data-start=\"3103\" data-end=\"3136\" data-col-size=\"md\"\u003eDC Adaptor, AC 220V \/ 50–60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3137\" data-end=\"3180\"\u003e\n\u003ctd data-start=\"3137\" data-end=\"3158\" data-col-size=\"sm\"\u003eDimensions (L×W×H)\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3158\" data-end=\"3180\"\u003e310 × 255 × 190 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3181\" data-end=\"3198\"\u003e\n\u003ctd data-start=\"3181\" data-end=\"3190\" data-col-size=\"sm\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-start=\"3190\" data-end=\"3198\" data-col-size=\"md\"\u003e2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 data-start=\"3200\" data-end=\"3215\"\u003eApplications\u003c\/h3\u003e\n\u003cp data-start=\"3217\" data-end=\"3448\"\u003eIndustrial wastewater analysis\u003cbr data-start=\"3247\" data-end=\"3250\"\u003eMunicipal water treatment testing\u003cbr data-start=\"3283\" data-end=\"3286\"\u003eEnvironmental monitoring laboratories\u003cbr data-start=\"3323\" data-end=\"3326\"\u003eWater quality analysis\u003cbr data-start=\"3348\" data-end=\"3351\"\u003eFood and beverage processing\u003cbr data-start=\"3379\" data-end=\"3382\"\u003eAcademic and research laboratories\u003cbr data-start=\"3416\" data-end=\"3419\"\u003eIndustrial process monitoring\u003c\/p\u003e","brand":"Labman","offers":[{"title":"Default Title","offer_id":49973052440813,"sku":null,"price":60000.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5672\/6765\/files\/LMTB200.jpg?v=1778962945","url":"https:\/\/www.biotronscientific.com\/products\/turbidity-meter-lmtb200-4-5-tft-display-tss-measurement-mode","provider":"BIOTRON","version":"1.0","type":"link"}