{"product_id":"total-organic-carbon-analyzer-toc2ndir-uv-oxidation-ndir-detection-0-10000-mg-l","title":"Total Organic Carbon Analyzer TOC2NDIR (UV Oxidation, NDIR Detection, 0–10000 mg\/L)","description":"\u003cp data-start=\"293\" data-end=\"913\"\u003eTotal Organic Carbon Analyzer TOC2NDIR is designed for accurate measurement of carbon content in liquid samples using UV oxidation combined with non-dispersive infrared (NDIR) detection. The system enables reliable quantification of total carbon and its components, supporting critical water quality monitoring applications. It features precise gas flow control, automatic leakage detection and integrated software for data management and analysis. With modular design and computer-based control, the instrument ensures stable performance, ease of operation and consistent analytical results across laboratory workflows.\u003c\/p\u003e\n\u003ch3 data-start=\"915\" data-end=\"932\"\u003eKey Features\u003c\/h3\u003e\n\u003cp data-start=\"933\" data-end=\"1458\"\u003eUV oxidation with NDIR detection for high sensitivity measurement\u003cbr data-start=\"998\" data-end=\"1001\"\u003eWide measurement range up to 10000 mg\/L\u003cbr data-start=\"1040\" data-end=\"1043\"\u003eSupports TC, TIC, TOC and NPOC analysis modes\u003cbr data-start=\"1088\" data-end=\"1091\"\u003eAutomatic leakage detection for operational safety\u003cbr data-start=\"1141\" data-end=\"1144\"\u003eAdvanced gas flow control for improved accuracy\u003cbr data-start=\"1191\" data-end=\"1194\"\u003eIntegrated PC software for data analysis and reporting\u003cbr data-start=\"1248\" data-end=\"1251\"\u003eModular design for easy maintenance and operation\u003cbr data-start=\"1300\" data-end=\"1303\"\u003eReal-time data monitoring and curve visualization\u003cbr data-start=\"1352\" data-end=\"1355\"\u003eSupports electronic data export and reporting\u003cbr data-start=\"1400\" data-end=\"1403\"\u003eHigh repeatability and stable measurement performance\u003c\/p\u003e\n\u003ch3 data-start=\"1460\" data-end=\"1489\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"1490\" data-end=\"2238\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"1490\" data-end=\"1519\"\u003e\n\u003ctr data-start=\"1490\" data-end=\"1519\"\u003e\n\u003cth data-start=\"1490\" data-end=\"1502\" data-col-size=\"sm\" class=\"\"\u003eParameter\u003c\/th\u003e\n\u003cth data-start=\"1502\" data-end=\"1519\" data-col-size=\"md\" class=\"\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"1530\" data-end=\"2238\"\u003e\n\u003ctr data-start=\"1530\" data-end=\"1563\"\u003e\n\u003ctd data-start=\"1530\" data-end=\"1547\" data-col-size=\"sm\"\u003eEquipment Type\u003c\/td\u003e\n\u003ctd data-start=\"1547\" data-end=\"1563\" data-col-size=\"md\"\u003eTOC Analyzer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1564\" data-end=\"1584\"\u003e\n\u003ctd data-start=\"1564\" data-end=\"1572\" data-col-size=\"sm\"\u003eModel\u003c\/td\u003e\n\u003ctd data-start=\"1572\" data-end=\"1584\" data-col-size=\"md\"\u003eTOC2NDIR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1585\" data-end=\"1620\"\u003e\n\u003ctd data-start=\"1585\" data-end=\"1604\" data-col-size=\"sm\"\u003eDetection Method\u003c\/td\u003e\n\u003ctd data-start=\"1604\" data-end=\"1620\" data-col-size=\"md\"\u003eUV Oxidation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1621\" data-end=\"1666\"\u003e\n\u003ctd data-start=\"1621\" data-end=\"1632\" data-col-size=\"sm\"\u003eDetector\u003c\/td\u003e\n\u003ctd data-start=\"1632\" data-end=\"1666\" data-col-size=\"md\"\u003eNDIR (Non-Dispersive Infrared)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1667\" data-end=\"1705\"\u003e\n\u003ctd data-start=\"1667\" data-end=\"1687\" data-col-size=\"sm\"\u003eMeasurement Range\u003c\/td\u003e\n\u003ctd data-start=\"1687\" data-end=\"1705\" data-col-size=\"md\"\u003e0 – 10000 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1706\" data-end=\"1734\"\u003e\n\u003ctd data-start=\"1706\" data-end=\"1724\" data-col-size=\"sm\"\u003eDetection Limit\u003c\/td\u003e\n\u003ctd data-start=\"1724\" data-end=\"1734\" data-col-size=\"md\"\u003e5 µg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1735\" data-end=\"1759\"\u003e\n\u003ctd data-start=\"1735\" data-end=\"1751\" data-col-size=\"sm\"\u003eRepeatability\u003c\/td\u003e\n\u003ctd data-start=\"1751\" data-end=\"1759\" data-col-size=\"md\"\u003e≤ 3%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1760\" data-end=\"1789\"\u003e\n\u003ctd data-start=\"1760\" data-end=\"1779\" data-col-size=\"sm\"\u003eMaximum Salinity\u003c\/td\u003e\n\u003ctd data-start=\"1779\" data-end=\"1789\" data-col-size=\"md\"\u003e85 g\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1790\" data-end=\"1818\"\u003e\n\u003ctd data-start=\"1790\" data-end=\"1806\" data-col-size=\"sm\"\u003eParticle Size\u003c\/td\u003e\n\u003ctd data-start=\"1806\" data-end=\"1818\" data-col-size=\"md\"\u003e≤ 0.2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1819\" data-end=\"1863\"\u003e\n\u003ctd data-start=\"1819\" data-end=\"1841\" data-col-size=\"sm\"\u003eAnalysis Parameters\u003c\/td\u003e\n\u003ctd data-start=\"1841\" data-end=\"1863\" data-col-size=\"md\"\u003eTC, TIC, TOC, NPOC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1864\" data-end=\"1888\"\u003e\n\u003ctd data-start=\"1864\" data-end=\"1878\" data-col-size=\"sm\"\u003eSample Type\u003c\/td\u003e\n\u003ctd data-start=\"1878\" data-end=\"1888\" data-col-size=\"md\"\u003eLiquid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1889\" data-end=\"1931\"\u003e\n\u003ctd data-start=\"1889\" data-end=\"1907\" data-col-size=\"sm\"\u003eGas Requirement\u003c\/td\u003e\n\u003ctd data-start=\"1907\" data-end=\"1931\" data-col-size=\"md\"\u003eNitrogen (≥ 99.995%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1932\" data-end=\"1960\"\u003e\n\u003ctd data-start=\"1932\" data-end=\"1942\" data-col-size=\"sm\"\u003eControl\u003c\/td\u003e\n\u003ctd data-start=\"1942\" data-end=\"1960\" data-col-size=\"md\"\u003eComputer-based\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1961\" data-end=\"1980\"\u003e\n\u003ctd data-start=\"1961\" data-end=\"1973\" data-col-size=\"sm\"\u003eInterface\u003c\/td\u003e\n\u003ctd data-start=\"1973\" data-end=\"1980\" data-col-size=\"md\"\u003eUSB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1981\" data-end=\"2008\"\u003e\n\u003ctd data-start=\"1981\" data-end=\"1996\" data-col-size=\"sm\"\u003eAuto Sampler\u003c\/td\u003e\n\u003ctd data-start=\"1996\" data-end=\"2008\" data-col-size=\"md\"\u003eOptional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2009\" data-end=\"2029\"\u003e\n\u003ctd data-start=\"2009\" data-end=\"2020\" data-col-size=\"sm\"\u003eHumidity\u003c\/td\u003e\n\u003ctd data-start=\"2020\" data-end=\"2029\" data-col-size=\"md\"\u003e≤ 85%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2030\" data-end=\"2067\"\u003e\n\u003ctd data-start=\"2030\" data-end=\"2045\" data-col-size=\"sm\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd data-start=\"2045\" data-end=\"2067\" data-col-size=\"md\"\u003eAC 220V \/ 50–60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2068\" data-end=\"2103\"\u003e\n\u003ctd data-start=\"2068\" data-end=\"2081\" data-col-size=\"sm\"\u003eDimensions\u003c\/td\u003e\n\u003ctd data-start=\"2081\" data-end=\"2103\" data-col-size=\"md\"\u003e660 × 610 × 685 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2104\" data-end=\"2130\"\u003e\n\u003ctd data-start=\"2104\" data-end=\"2113\" data-col-size=\"sm\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-start=\"2113\" data-end=\"2130\" data-col-size=\"md\"\u003eApprox. 43 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2131\" data-end=\"2171\"\u003e\n\u003ctd data-start=\"2131\" data-end=\"2145\" data-col-size=\"sm\"\u003eApplication\u003c\/td\u003e\n\u003ctd data-start=\"2145\" data-end=\"2171\" data-col-size=\"md\"\u003eWater quality analysis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2172\" data-end=\"2238\"\u003e\n\u003ctd data-start=\"2172\" data-end=\"2180\" data-col-size=\"sm\"\u003eUsage\u003c\/td\u003e\n\u003ctd data-start=\"2180\" data-end=\"2238\" data-col-size=\"md\"\u003eEnvironmental, pharmaceutical and laboratory workflows\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Labman","offers":[{"title":"Default Title","offer_id":49828404953325,"sku":null,"price":1200000.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5672\/6765\/files\/toc2ndir.webp?v=1777035310","url":"https:\/\/www.biotronscientific.com\/products\/total-organic-carbon-analyzer-toc2ndir-uv-oxidation-ndir-detection-0-10000-mg-l","provider":"BIOTRON","version":"1.0","type":"link"}