{"product_id":"single-beam-uv-vis-spectrophotometer-luv1100t-190-1100-nm-touchscreen","title":"Single Beam UV-Vis Spectrophotometer LUV1100T (190–1100 nm, Touchscreen)","description":"\u003cp data-start=\"312\" data-end=\"638\"\u003eThe Single Beam UV-Vis Spectrophotometer LUV1100T is designed for routine and advanced spectrophotometric analysis across UV, visible, and near-infrared regions from 190 to 1100 nm. It uses a precision single beam optical system with a high-performance grating monochromator to deliver reliable and stable measurement results.\u003c\/p\u003e\n\u003cp data-start=\"640\" data-end=\"917\"\u003eThe optical system is fully sealed and equipped with SiO2-coated mirrors to minimize stray light and protect against environmental factors such as dust and corrosive gases. This ensures improved baseline stability and long-term operational reliability in laboratory conditions.\u003c\/p\u003e\n\u003cp data-start=\"919\" data-end=\"1225\"\u003eThe instrument features a 7-inch touchscreen interface with an integrated computing system, allowing standalone operation without requiring an external PC. It supports multiple analytical modes including photometric measurement, quantitative analysis, spectral scanning, kinetics, and DNA\/protein analysis.\u003c\/p\u003e\n\u003cp data-start=\"1227\" data-end=\"1622\"\u003eEquipped with tungsten and deuterium lamps, the system enables accurate measurement across the full wavelength range. It includes internal 32GB memory for data storage and supports USB data export and direct printing. The software complies with GLP\/GMP requirements and includes user management, audit trails, and data tracking features, making it suitable for regulated laboratory environments.\u003c\/p\u003e\n\u003ch3 data-start=\"1624\" data-end=\"1641\"\u003eKey Features\u003c\/h3\u003e\n\u003cp data-start=\"1642\" data-end=\"2109\"\u003eSingle beam optical system with stable performance\u003cbr data-start=\"1692\" data-end=\"1695\"\u003e190–1100 nm wide wavelength range\u003cbr data-start=\"1728\" data-end=\"1731\"\u003e7-inch touchscreen with standalone operation\u003cbr data-start=\"1775\" data-end=\"1778\"\u003e32GB internal storage for data handling\u003cbr data-start=\"1817\" data-end=\"1820\"\u003eSealed optics with SiO2 coating for low stray light\u003cbr data-start=\"1871\" data-end=\"1874\"\u003eTungsten and deuterium lamp system\u003cbr data-start=\"1908\" data-end=\"1911\"\u003eSupports photometric, quantitative and spectral analysis\u003cbr data-start=\"1967\" data-end=\"1970\"\u003eUSB data export and printing support\u003cbr data-start=\"2006\" data-end=\"2009\"\u003eGLP\/GMP compliant software with audit trail\u003cbr data-start=\"2052\" data-end=\"2055\"\u003eAutomatic self-test and calibration before operation\u003c\/p\u003e\n\u003ch3 data-start=\"2111\" data-end=\"2140\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"2142\" data-end=\"3020\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"2142\" data-end=\"2166\"\u003e\n\u003ctr data-start=\"2142\" data-end=\"2166\"\u003e\n\u003cth data-start=\"2142\" data-end=\"2154\" data-col-size=\"sm\" class=\"\"\u003eParameter\u003c\/th\u003e\n\u003cth data-start=\"2154\" data-end=\"2166\" data-col-size=\"sm\" class=\"\"\u003eLUV1100T\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"2191\" data-end=\"3020\"\u003e\n\u003ctr data-start=\"2191\" data-end=\"2208\"\u003e\n\u003ctd data-start=\"2191\" data-end=\"2198\" data-col-size=\"sm\"\u003eMake\u003c\/td\u003e\n\u003ctd data-start=\"2198\" data-end=\"2208\" data-col-size=\"sm\"\u003eLABMAN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2209\" data-end=\"2241\"\u003e\n\u003ctd data-start=\"2209\" data-end=\"2226\" data-col-size=\"sm\"\u003eOptical System\u003c\/td\u003e\n\u003ctd data-start=\"2226\" data-end=\"2241\" data-col-size=\"sm\"\u003eSingle Beam\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2242\" data-end=\"2275\"\u003e\n\u003ctd data-start=\"2242\" data-end=\"2253\" data-col-size=\"sm\"\u003eDetector\u003c\/td\u003e\n\u003ctd data-start=\"2253\" data-end=\"2275\" data-col-size=\"sm\"\u003eSilicon Photodiode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2276\" data-end=\"2310\"\u003e\n\u003ctd data-start=\"2276\" data-end=\"2295\" data-col-size=\"sm\"\u003eWavelength Range\u003c\/td\u003e\n\u003ctd data-start=\"2295\" data-end=\"2310\" data-col-size=\"sm\"\u003e190–1100 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2311\" data-end=\"2333\"\u003e\n\u003ctd data-start=\"2311\" data-end=\"2323\" data-col-size=\"sm\"\u003eBandwidth\u003c\/td\u003e\n\u003ctd data-start=\"2323\" data-end=\"2333\" data-col-size=\"sm\"\u003e2.0 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2334\" data-end=\"2367\"\u003e\n\u003ctd data-start=\"2334\" data-end=\"2356\" data-col-size=\"sm\"\u003eWavelength Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"2356\" data-end=\"2367\" data-col-size=\"sm\"\u003e±0.5 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2368\" data-end=\"2406\"\u003e\n\u003ctd data-start=\"2368\" data-end=\"2395\" data-col-size=\"sm\"\u003eWavelength Repeatability\u003c\/td\u003e\n\u003ctd data-start=\"2395\" data-end=\"2406\" data-col-size=\"sm\"\u003e±0.2 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2407\" data-end=\"2459\"\u003e\n\u003ctd data-start=\"2407\" data-end=\"2427\" data-col-size=\"sm\"\u003ePhotometric Range\u003c\/td\u003e\n\u003ctd data-start=\"2427\" data-end=\"2459\" data-col-size=\"sm\"\u003e0–200%T, -0.3 to 3A, 0–9999C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2460\" data-end=\"2505\"\u003e\n\u003ctd data-start=\"2460\" data-end=\"2483\" data-col-size=\"sm\"\u003ePhotometric Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"2483\" data-end=\"2505\" data-col-size=\"sm\"\u003e±0.2%T, ±0.002 Abs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2506\" data-end=\"2544\"\u003e\n\u003ctd data-start=\"2506\" data-end=\"2534\" data-col-size=\"sm\"\u003ePhotometric Repeatability\u003c\/td\u003e\n\u003ctd data-start=\"2534\" data-end=\"2544\" data-col-size=\"sm\"\u003e≤0.1%T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2545\" data-end=\"2582\"\u003e\n\u003ctd data-start=\"2545\" data-end=\"2557\" data-col-size=\"sm\"\u003eStability\u003c\/td\u003e\n\u003ctd data-start=\"2557\" data-end=\"2582\" data-col-size=\"sm\"\u003e±0.001 Abs\/h @ 500 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2583\" data-end=\"2625\"\u003e\n\u003ctd data-start=\"2583\" data-end=\"2597\" data-col-size=\"sm\"\u003eStray Light\u003c\/td\u003e\n\u003ctd data-start=\"2597\" data-end=\"2625\" data-col-size=\"sm\"\u003e≤0.05%T (220 nm, 360 nm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2626\" data-end=\"2675\"\u003e\n\u003ctd data-start=\"2626\" data-end=\"2641\" data-col-size=\"sm\"\u003eLight Source\u003c\/td\u003e\n\u003ctd data-start=\"2641\" data-end=\"2675\" data-col-size=\"sm\"\u003eTungsten Lamp \u0026amp; Deuterium Lamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2676\" data-end=\"2699\"\u003e\n\u003ctd data-start=\"2676\" data-end=\"2689\" data-col-size=\"sm\"\u003eResolution\u003c\/td\u003e\n\u003ctd data-start=\"2689\" data-end=\"2699\" data-col-size=\"sm\"\u003e0.1 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2700\" data-end=\"2757\"\u003e\n\u003ctd data-start=\"2700\" data-end=\"2714\" data-col-size=\"sm\"\u003eCell Holder\u003c\/td\u003e\n\u003ctd data-start=\"2714\" data-end=\"2757\" data-col-size=\"sm\"\u003e10 mm Sample \u0026amp; Reference Cuvette Holder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2758\" data-end=\"2800\"\u003e\n\u003ctd data-start=\"2758\" data-end=\"2768\" data-col-size=\"sm\"\u003eDisplay\u003c\/td\u003e\n\u003ctd data-start=\"2768\" data-end=\"2800\" data-col-size=\"sm\"\u003e7-inch Touchscreen (800×480)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2801\" data-end=\"2819\"\u003e\n\u003ctd data-start=\"2801\" data-end=\"2810\" data-col-size=\"sm\"\u003eMemory\u003c\/td\u003e\n\u003ctd data-start=\"2810\" data-end=\"2819\" data-col-size=\"sm\"\u003e32 GB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2820\" data-end=\"2863\"\u003e\n\u003ctd data-start=\"2820\" data-end=\"2835\" data-col-size=\"sm\"\u003eControl Mode\u003c\/td\u003e\n\u003ctd data-start=\"2835\" data-end=\"2863\" data-col-size=\"sm\"\u003eStandalone \/ PC Software\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2864\" data-end=\"2885\"\u003e\n\u003ctd data-start=\"2864\" data-end=\"2878\" data-col-size=\"sm\"\u003eData Output\u003c\/td\u003e\n\u003ctd data-start=\"2878\" data-end=\"2885\" data-col-size=\"sm\"\u003eUSB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2886\" data-end=\"2920\"\u003e\n\u003ctd data-start=\"2886\" data-end=\"2906\" data-col-size=\"sm\"\u003eBaseline Flatness\u003c\/td\u003e\n\u003ctd data-start=\"2906\" data-end=\"2920\" data-col-size=\"sm\"\u003e±0.001 Abs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2921\" data-end=\"2957\"\u003e\n\u003ctd data-start=\"2921\" data-end=\"2936\" data-col-size=\"sm\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd data-start=\"2936\" data-end=\"2957\" data-col-size=\"sm\"\u003eAC 220V \/ 50–60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2958\" data-end=\"3001\"\u003e\n\u003ctd data-start=\"2958\" data-end=\"2979\" data-col-size=\"sm\"\u003eDimensions (L×W×H)\u003c\/td\u003e\n\u003ctd data-start=\"2979\" data-end=\"3001\" data-col-size=\"sm\"\u003e645 × 550 × 405 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3002\" data-end=\"3020\"\u003e\n\u003ctd data-start=\"3002\" data-end=\"3011\" data-col-size=\"sm\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-start=\"3011\" data-end=\"3020\" data-col-size=\"sm\"\u003e25 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 data-start=\"3022\" data-end=\"3039\"\u003eApplications\u003c\/h3\u003e\n\u003cp data-start=\"3040\" data-end=\"3245\"\u003ePharmaceutical quality control and validation\u003cbr data-start=\"3085\" data-end=\"3088\"\u003eChemical and environmental analysis\u003cbr data-start=\"3123\" data-end=\"3126\"\u003eBiotechnology and life science research\u003cbr data-start=\"3165\" data-end=\"3168\"\u003eFood and beverage testing laboratories\u003cbr data-start=\"3206\" data-end=\"3209\"\u003eAcademic and teaching laboratories\u003c\/p\u003e","brand":"Labman","offers":[{"title":"Default Title","offer_id":49929406185709,"sku":null,"price":210000.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5672\/6765\/files\/LUV1100T.webp?v=1778877738","url":"https:\/\/www.biotronscientific.com\/products\/single-beam-uv-vis-spectrophotometer-luv1100t-190-1100-nm-touchscreen","provider":"BIOTRON","version":"1.0","type":"link"}