{"product_id":"single-beam-uv-vis-spectrophotometer-lmspuv1200-190-1100-nm","title":"Single Beam UV-Vis Spectrophotometer LMSPUV1200 (190–1100 nm)","description":"\u003cp data-start=\"300\" data-end=\"645\"\u003eThe LMSPUV1200 Single Beam UV-Vis Spectrophotometer is designed for accurate and consistent spectrophotometric analysis across the ultraviolet and visible spectrum from 190 to 1100 nm. It utilizes a single beam optical system with a 1200 lines\/mm grating to deliver stable and precise measurement performance for routine laboratory applications.\u003c\/p\u003e\n\u003cp data-start=\"647\" data-end=\"950\"\u003eThe instrument is built on a rigid die-cast aluminum optical base, ensuring mechanical stability and minimizing the effects of vibration and environmental variations. The system features automatic wavelength setting through keypad control, allowing easy operation and reducing the risk of manual errors.\u003c\/p\u003e\n\u003cp data-start=\"952\" data-end=\"1203\"\u003eEquipped with both deuterium and tungsten halogen lamps, the spectrophotometer provides reliable performance across the full wavelength range. Lamp selection can be controlled independently to extend operational life and maintain measurement accuracy.\u003c\/p\u003e\n\u003cp data-start=\"1205\" data-end=\"1457\"\u003eThe system supports standard curve generation, enabling quantitative analysis and determination of unknown concentrations. Data output is available via USB for integration with external systems, and results can be processed using connected PC software.\u003c\/p\u003e\n\u003cp data-start=\"1459\" data-end=\"1742\"\u003eA large sample compartment accommodates standard 10 mm cuvettes with a 4-position holder, and optional accessories allow extended path length measurements up to 100 mm. The instrument is suitable for routine quality control, academic research, and industrial laboratory applications.\u003c\/p\u003e\n\u003ch3 data-start=\"1744\" data-end=\"1761\"\u003eKey Features\u003c\/h3\u003e\n\u003cp data-start=\"1762\" data-end=\"2233\"\u003eSingle beam optical system with 1200 lines\/mm grating\u003cbr data-start=\"1815\" data-end=\"1818\"\u003e190–1100 nm wavelength range\u003cbr data-start=\"1846\" data-end=\"1849\"\u003eAutomatic wavelength setting with keypad control\u003cbr data-start=\"1897\" data-end=\"1900\"\u003eRigid die-cast aluminum optical base\u003cbr data-start=\"1936\" data-end=\"1939\"\u003eSupports standard curve and quantitative analysis\u003cbr data-start=\"1988\" data-end=\"1991\"\u003eDual lamp system (Deuterium and Tungsten)\u003cbr data-start=\"2032\" data-end=\"2035\"\u003eUSB data output for PC connectivity\u003cbr data-start=\"2070\" data-end=\"2073\"\u003e4-position cuvette holder with large sample compartment\u003cbr data-start=\"2128\" data-end=\"2131\"\u003eLow stray light with stable photometric performance\u003cbr data-start=\"2182\" data-end=\"2185\"\u003eSuitable for routine and research applications\u003c\/p\u003e\n\u003ch3 data-start=\"2235\" data-end=\"2264\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"2266\" data-end=\"3085\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"2266\" data-end=\"2292\"\u003e\n\u003ctr data-start=\"2266\" data-end=\"2292\"\u003e\n\u003cth data-start=\"2266\" data-end=\"2278\" data-col-size=\"sm\" class=\"\"\u003eParameter\u003c\/th\u003e\n\u003cth data-start=\"2278\" data-end=\"2292\" data-col-size=\"sm\" class=\"\"\u003eLMSPUV1200\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"2319\" data-end=\"3085\"\u003e\n\u003ctr data-start=\"2319\" data-end=\"2336\"\u003e\n\u003ctd data-start=\"2319\" data-end=\"2326\" data-col-size=\"sm\"\u003eMake\u003c\/td\u003e\n\u003ctd data-start=\"2326\" data-end=\"2336\" data-col-size=\"sm\"\u003eLABMAN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2337\" data-end=\"2392\"\u003e\n\u003ctd data-start=\"2337\" data-end=\"2354\" data-col-size=\"sm\"\u003eOptical System\u003c\/td\u003e\n\u003ctd data-start=\"2354\" data-end=\"2392\" data-col-size=\"sm\"\u003eSingle Beam, Grating 1200 lines\/mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2393\" data-end=\"2426\"\u003e\n\u003ctd data-start=\"2393\" data-end=\"2404\" data-col-size=\"sm\"\u003eDetector\u003c\/td\u003e\n\u003ctd data-start=\"2404\" data-end=\"2426\" data-col-size=\"sm\"\u003eSilicon Photodiode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2427\" data-end=\"2461\"\u003e\n\u003ctd data-start=\"2427\" data-end=\"2446\" data-col-size=\"sm\"\u003eWavelength Range\u003c\/td\u003e\n\u003ctd data-start=\"2446\" data-end=\"2461\" data-col-size=\"sm\"\u003e190–1100 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2462\" data-end=\"2482\"\u003e\n\u003ctd data-start=\"2462\" data-end=\"2474\" data-col-size=\"sm\"\u003eBandwidth\u003c\/td\u003e\n\u003ctd data-start=\"2474\" data-end=\"2482\" data-col-size=\"sm\"\u003e2 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2483\" data-end=\"2516\"\u003e\n\u003ctd data-start=\"2483\" data-end=\"2505\" data-col-size=\"sm\"\u003eWavelength Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"2505\" data-end=\"2516\" data-col-size=\"sm\"\u003e±0.8 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2517\" data-end=\"2555\"\u003e\n\u003ctd data-start=\"2517\" data-end=\"2544\" data-col-size=\"sm\"\u003eWavelength Repeatability\u003c\/td\u003e\n\u003ctd data-start=\"2544\" data-end=\"2555\" data-col-size=\"sm\"\u003e±0.2 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2556\" data-end=\"2590\"\u003e\n\u003ctd data-start=\"2556\" data-end=\"2577\" data-col-size=\"sm\"\u003eWavelength Setting\u003c\/td\u003e\n\u003ctd data-start=\"2577\" data-end=\"2590\" data-col-size=\"sm\"\u003eAutomatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2591\" data-end=\"2631\"\u003e\n\u003ctd data-start=\"2591\" data-end=\"2611\" data-col-size=\"sm\"\u003ePhotometric Range\u003c\/td\u003e\n\u003ctd data-start=\"2611\" data-end=\"2631\" data-col-size=\"sm\"\u003e-0.3–3A, 0–200%T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2632\" data-end=\"2665\"\u003e\n\u003ctd data-start=\"2632\" data-end=\"2655\" data-col-size=\"sm\"\u003ePhotometric Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"2655\" data-end=\"2665\" data-col-size=\"sm\"\u003e±0.3%T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2666\" data-end=\"2704\"\u003e\n\u003ctd data-start=\"2666\" data-end=\"2694\" data-col-size=\"sm\"\u003ePhotometric Repeatability\u003c\/td\u003e\n\u003ctd data-start=\"2694\" data-end=\"2704\" data-col-size=\"sm\"\u003e±0.2%T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2705\" data-end=\"2742\"\u003e\n\u003ctd data-start=\"2705\" data-end=\"2717\" data-col-size=\"sm\"\u003eStability\u003c\/td\u003e\n\u003ctd data-start=\"2717\" data-end=\"2742\" data-col-size=\"sm\"\u003e±0.002 Abs\/h @ 500 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2743\" data-end=\"2777\"\u003e\n\u003ctd data-start=\"2743\" data-end=\"2763\" data-col-size=\"sm\"\u003eBaseline Flatness\u003c\/td\u003e\n\u003ctd data-start=\"2763\" data-end=\"2777\" data-col-size=\"sm\"\u003e±0.002 Abs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2778\" data-end=\"2803\"\u003e\n\u003ctd data-start=\"2778\" data-end=\"2792\" data-col-size=\"sm\"\u003eStray Light\u003c\/td\u003e\n\u003ctd data-start=\"2792\" data-end=\"2803\" data-col-size=\"sm\"\u003e≤0.05%T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2804\" data-end=\"2861\"\u003e\n\u003ctd data-start=\"2804\" data-end=\"2819\" data-col-size=\"sm\"\u003eLight Source\u003c\/td\u003e\n\u003ctd data-start=\"2819\" data-end=\"2861\" data-col-size=\"sm\"\u003eDeuterium Lamp \u0026amp; Tungsten Halogen Lamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2862\" data-end=\"2879\"\u003e\n\u003ctd data-start=\"2862\" data-end=\"2872\" data-col-size=\"sm\"\u003eDisplay\u003c\/td\u003e\n\u003ctd data-start=\"2872\" data-end=\"2879\" data-col-size=\"sm\"\u003eLCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2880\" data-end=\"2930\"\u003e\n\u003ctd data-start=\"2880\" data-end=\"2894\" data-col-size=\"sm\"\u003eCell Holder\u003c\/td\u003e\n\u003ctd data-start=\"2894\" data-end=\"2930\" data-col-size=\"sm\"\u003e10 mm, 4-position cuvette holder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2931\" data-end=\"2952\"\u003e\n\u003ctd data-start=\"2931\" data-end=\"2945\" data-col-size=\"sm\"\u003eData Output\u003c\/td\u003e\n\u003ctd data-start=\"2945\" data-end=\"2952\" data-col-size=\"sm\"\u003eUSB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2953\" data-end=\"2985\"\u003e\n\u003ctd data-start=\"2953\" data-end=\"2968\" data-col-size=\"sm\"\u003ePrinter Port\u003c\/td\u003e\n\u003ctd data-start=\"2968\" data-end=\"2985\" data-col-size=\"sm\"\u003eParallel Port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2986\" data-end=\"3022\"\u003e\n\u003ctd data-start=\"2986\" data-end=\"3001\" data-col-size=\"sm\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd data-start=\"3001\" data-end=\"3022\" data-col-size=\"sm\"\u003eAC 220V \/ 50–60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3023\" data-end=\"3066\"\u003e\n\u003ctd data-start=\"3023\" data-end=\"3044\" data-col-size=\"sm\"\u003eDimensions (L×W×H)\u003c\/td\u003e\n\u003ctd data-start=\"3044\" data-end=\"3066\" data-col-size=\"sm\"\u003e640 × 550 × 400 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3067\" data-end=\"3085\"\u003e\n\u003ctd data-start=\"3067\" data-end=\"3076\" data-col-size=\"sm\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-start=\"3076\" data-end=\"3085\" data-col-size=\"sm\"\u003e24 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 data-start=\"3087\" data-end=\"3104\"\u003eApplications\u003c\/h3\u003e\n\u003cp data-start=\"3105\" data-end=\"3291\"\u003ePharmaceutical quality control laboratories\u003cbr data-start=\"3148\" data-end=\"3151\"\u003eChemical and environmental analysis\u003cbr data-start=\"3186\" data-end=\"3189\"\u003eAcademic and teaching laboratories\u003cbr data-start=\"3223\" data-end=\"3226\"\u003eFood and beverage testing\u003cbr data-start=\"3251\" data-end=\"3254\"\u003eRoutine spectrophotometric analysis\u003c\/p\u003e","brand":"Labman","offers":[{"title":"Default Title","offer_id":49929415852269,"sku":null,"price":150000.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5672\/6765\/files\/LMSPUV1200.jpg?v=1778916253","url":"https:\/\/www.biotronscientific.com\/products\/single-beam-uv-vis-spectrophotometer-lmspuv1200-190-1100-nm","provider":"BIOTRON","version":"1.0","type":"link"}