{"product_id":"single-beam-uv-vis-spectrophotometer-lmspuv1000b-190-1000-nm-basic-model","title":"Single Beam UV-Vis Spectrophotometer LMSPUV1000B (190–1000 nm, Basic Model)","description":"\u003cp data-start=\"310\" data-end=\"611\"\u003eThe LMSPUV1000B is a basic single beam UV-Vis spectrophotometer designed for routine analytical applications where reliability and simplicity are required. Covering a wavelength range of 190 to 1000 nm, the instrument is suitable for standard absorbance and transmittance measurements in laboratories.\u003c\/p\u003e\n\u003cp data-start=\"613\" data-end=\"881\"\u003eIt uses a single beam optical system with a 1200 lines\/mm grating to provide stable and consistent measurement results. The rigid die-cast aluminum optical base enhances structural stability and minimizes external interference, ensuring dependable operation over time.\u003c\/p\u003e\n\u003cp data-start=\"883\" data-end=\"1138\"\u003eThe instrument features automatic wavelength setting, allowing users to quickly select required wavelengths and reduce manual errors. It supports standard curve generation, enabling quantitative analysis and determination of unknown sample concentrations.\u003c\/p\u003e\n\u003cp data-start=\"1140\" data-end=\"1402\"\u003eEquipped with both deuterium and tungsten halogen lamps, the system ensures coverage across UV and visible regions. The LCD display provides clear readouts of wavelength, absorbance, and transmittance, with the ability to display multiple results simultaneously.\u003c\/p\u003e\n\u003cp data-start=\"1404\" data-end=\"1646\"\u003eA 4-position cuvette holder supports efficient sample handling, while USB connectivity allows data transfer to external systems. The instrument also includes memory storage for up to 200 results and retains data in case of power interruption.\u003c\/p\u003e\n\u003ch3 data-start=\"1648\" data-end=\"1665\"\u003eKey Features\u003c\/h3\u003e\n\u003cp data-start=\"1666\" data-end=\"2069\"\u003eSingle beam optical system with stable performance\u003cbr data-start=\"1716\" data-end=\"1719\"\u003e190–1000 nm wavelength range\u003cbr data-start=\"1747\" data-end=\"1750\"\u003eAutomatic wavelength setting\u003cbr data-start=\"1778\" data-end=\"1781\"\u003eRigid die-cast aluminum optical base\u003cbr data-start=\"1817\" data-end=\"1820\"\u003eSupports standard curve and quantitative analysis\u003cbr data-start=\"1869\" data-end=\"1872\"\u003eDual lamp system for UV and visible regions\u003cbr data-start=\"1915\" data-end=\"1918\"\u003eLCD display with multi-result readout\u003cbr data-start=\"1955\" data-end=\"1958\"\u003e4-position cuvette holder\u003cbr data-start=\"1983\" data-end=\"1986\"\u003eUSB and printer connectivity\u003cbr data-start=\"2014\" data-end=\"2017\"\u003eMemory storage with data recovery after power loss\u003c\/p\u003e\n\u003ch3 data-start=\"2071\" data-end=\"2100\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"2102\" data-end=\"2872\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"2102\" data-end=\"2129\"\u003e\n\u003ctr data-start=\"2102\" data-end=\"2129\"\u003e\n\u003cth data-start=\"2102\" data-end=\"2114\" data-col-size=\"sm\" class=\"\"\u003eParameter\u003c\/th\u003e\n\u003cth data-start=\"2114\" data-end=\"2129\" data-col-size=\"sm\" class=\"\"\u003eLMSPUV1000B\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"2157\" data-end=\"2872\"\u003e\n\u003ctr data-start=\"2157\" data-end=\"2174\"\u003e\n\u003ctd data-start=\"2157\" data-end=\"2164\" data-col-size=\"sm\"\u003eMake\u003c\/td\u003e\n\u003ctd data-start=\"2164\" data-end=\"2174\" data-col-size=\"sm\"\u003eLABMAN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2175\" data-end=\"2230\"\u003e\n\u003ctd data-start=\"2175\" data-end=\"2192\" data-col-size=\"sm\"\u003eOptical System\u003c\/td\u003e\n\u003ctd data-start=\"2192\" data-end=\"2230\" data-col-size=\"sm\"\u003eSingle Beam, Grating 1200 lines\/mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2231\" data-end=\"2264\"\u003e\n\u003ctd data-start=\"2231\" data-end=\"2242\" data-col-size=\"sm\"\u003eDetector\u003c\/td\u003e\n\u003ctd data-start=\"2242\" data-end=\"2264\" data-col-size=\"sm\"\u003eSilicon Photodiode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2265\" data-end=\"2299\"\u003e\n\u003ctd data-start=\"2265\" data-end=\"2284\" data-col-size=\"sm\"\u003eWavelength Range\u003c\/td\u003e\n\u003ctd data-start=\"2284\" data-end=\"2299\" data-col-size=\"sm\"\u003e190–1000 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2300\" data-end=\"2320\"\u003e\n\u003ctd data-start=\"2300\" data-end=\"2312\" data-col-size=\"sm\"\u003eBandwidth\u003c\/td\u003e\n\u003ctd data-start=\"2312\" data-end=\"2320\" data-col-size=\"sm\"\u003e2 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2321\" data-end=\"2352\"\u003e\n\u003ctd data-start=\"2321\" data-end=\"2343\" data-col-size=\"sm\"\u003eWavelength Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"2343\" data-end=\"2352\" data-col-size=\"sm\"\u003e±1 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2353\" data-end=\"2391\"\u003e\n\u003ctd data-start=\"2353\" data-end=\"2380\" data-col-size=\"sm\"\u003eWavelength Repeatability\u003c\/td\u003e\n\u003ctd data-start=\"2380\" data-end=\"2391\" data-col-size=\"sm\"\u003e±0.5 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2392\" data-end=\"2426\"\u003e\n\u003ctd data-start=\"2392\" data-end=\"2413\" data-col-size=\"sm\"\u003eWavelength Setting\u003c\/td\u003e\n\u003ctd data-start=\"2413\" data-end=\"2426\" data-col-size=\"sm\"\u003eAutomatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2427\" data-end=\"2467\"\u003e\n\u003ctd data-start=\"2427\" data-end=\"2447\" data-col-size=\"sm\"\u003ePhotometric Range\u003c\/td\u003e\n\u003ctd data-start=\"2447\" data-end=\"2467\" data-col-size=\"sm\"\u003e-0.3–3A, 0–200%T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2468\" data-end=\"2501\"\u003e\n\u003ctd data-start=\"2468\" data-end=\"2491\" data-col-size=\"sm\"\u003ePhotometric Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"2491\" data-end=\"2501\" data-col-size=\"sm\"\u003e±0.5%T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2502\" data-end=\"2540\"\u003e\n\u003ctd data-start=\"2502\" data-end=\"2530\" data-col-size=\"sm\"\u003ePhotometric Repeatability\u003c\/td\u003e\n\u003ctd data-start=\"2530\" data-end=\"2540\" data-col-size=\"sm\"\u003e±0.3%T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2541\" data-end=\"2578\"\u003e\n\u003ctd data-start=\"2541\" data-end=\"2553\" data-col-size=\"sm\"\u003eStability\u003c\/td\u003e\n\u003ctd data-start=\"2553\" data-end=\"2578\" data-col-size=\"sm\"\u003e±0.002 Abs\/h @ 500 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2579\" data-end=\"2603\"\u003e\n\u003ctd data-start=\"2579\" data-end=\"2593\" data-col-size=\"sm\"\u003eStray Light\u003c\/td\u003e\n\u003ctd data-start=\"2593\" data-end=\"2603\" data-col-size=\"sm\"\u003e≤0.3%T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2604\" data-end=\"2661\"\u003e\n\u003ctd data-start=\"2604\" data-end=\"2619\" data-col-size=\"sm\"\u003eLight Source\u003c\/td\u003e\n\u003ctd data-start=\"2619\" data-end=\"2661\" data-col-size=\"sm\"\u003eDeuterium Lamp \u0026amp; Tungsten Halogen Lamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2662\" data-end=\"2679\"\u003e\n\u003ctd data-start=\"2662\" data-end=\"2672\" data-col-size=\"sm\"\u003eDisplay\u003c\/td\u003e\n\u003ctd data-start=\"2672\" data-end=\"2679\" data-col-size=\"sm\"\u003eLCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2680\" data-end=\"2729\"\u003e\n\u003ctd data-start=\"2680\" data-end=\"2694\" data-col-size=\"sm\"\u003eCell Holder\u003c\/td\u003e\n\u003ctd data-start=\"2694\" data-end=\"2729\" data-col-size=\"sm\"\u003e4-position 10 mm cuvette holder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2730\" data-end=\"2772\"\u003e\n\u003ctd data-start=\"2730\" data-end=\"2744\" data-col-size=\"sm\"\u003eData Output\u003c\/td\u003e\n\u003ctd data-start=\"2744\" data-end=\"2772\" data-col-size=\"sm\"\u003eUSB \u0026amp; Parallel (Printer)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2773\" data-end=\"2809\"\u003e\n\u003ctd data-start=\"2773\" data-end=\"2788\" data-col-size=\"sm\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd data-start=\"2788\" data-end=\"2809\" data-col-size=\"sm\"\u003eAC 220V \/ 50–60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2810\" data-end=\"2853\"\u003e\n\u003ctd data-start=\"2810\" data-end=\"2831\" data-col-size=\"sm\"\u003eDimensions (L×W×H)\u003c\/td\u003e\n\u003ctd data-start=\"2831\" data-end=\"2853\" data-col-size=\"sm\"\u003e640 × 550 × 395 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2854\" data-end=\"2872\"\u003e\n\u003ctd data-start=\"2854\" data-end=\"2863\" data-col-size=\"sm\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-start=\"2863\" data-end=\"2872\" data-col-size=\"sm\"\u003e22 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 data-start=\"2874\" data-end=\"2891\"\u003eApplications\u003c\/h3\u003e\n\u003cp data-start=\"2892\" data-end=\"3058\"\u003eRoutine laboratory analysis\u003cbr data-start=\"2919\" data-end=\"2922\"\u003eEducational and academic laboratories\u003cbr data-start=\"2959\" data-end=\"2962\"\u003eChemical and environmental testing\u003cbr data-start=\"2996\" data-end=\"2999\"\u003eFood and beverage analysis\u003cbr data-start=\"3025\" data-end=\"3028\"\u003eBasic pharmaceutical testing\u003c\/p\u003e","brand":"Labman","offers":[{"title":"Default Title","offer_id":49929416147181,"sku":null,"price":120000.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5672\/6765\/files\/LMSPUV1000B.jpg?v=1778916306","url":"https:\/\/www.biotronscientific.com\/products\/single-beam-uv-vis-spectrophotometer-lmspuv1000b-190-1000-nm-basic-model","provider":"BIOTRON","version":"1.0","type":"link"}