{"product_id":"semi-micro-analytical-balance-tab10t-81-220g-capacity-internal-calibration","title":"Semi Micro \/ Analytical Balance TAB10T (81\/220g Capacity, Internal Calibration)","description":"\u003cp data-start=\"319\" data-end=\"725\"\u003eSemi Micro \/ Analytical Balance TAB10T is a high-precision laboratory balance developed for analytical, pharmaceutical, research, and quality control applications requiring exceptional measurement sensitivity and repeatability. Designed with dual weighing capacities of 81 g and 220 g and readability down to 0.01 mg and 0.1 mg, the instrument supports both semi-micro and analytical weighing requirements.\u003c\/p\u003e\n\u003cp data-start=\"727\" data-end=\"1029\"\u003eThe balance integrates advanced EMFC (Electromagnetic Force Compensation) technology to deliver stable performance, rapid response, and reliable weighing results. Internal calibration ensures consistent measurement accuracy while reducing manual calibration effort and improving operational efficiency.\u003c\/p\u003e\n\u003cp data-start=\"1031\" data-end=\"1276\"\u003eEquipped with a responsive 4.3-inch touchscreen display, TAB10T enables intuitive operation and access to multiple weighing functions including dynamic weighing, piece counting, percentage weighing, density determination, and summation weighing.\u003c\/p\u003e\n\u003cp data-start=\"1278\" data-end=\"1475\"\u003eThe system features GLP\/GMP compliance support, multi-unit operation, integrated temperature sensing, RS232C and USB connectivity, and configurable output modes for laboratory workflow integration.\u003c\/p\u003e\n\u003cp data-start=\"1477\" data-end=\"1689\"\u003eWith compact construction, antistatic glass windshield design, and precision measurement capability, TAB10T is suitable for laboratories performing highly accurate analytical and semi-micro weighing applications.\u003c\/p\u003e\n\u003ch3 data-start=\"1691\" data-end=\"1706\"\u003eKey Features\u003c\/h3\u003e\n\u003cp data-start=\"1708\" data-end=\"2133\"\u003e81 g \/ 220 g dual weighing capacity\u003cbr data-start=\"1743\" data-end=\"1746\"\u003eUltra-fine readability of 0.01 mg \/ 0.1 mg\u003cbr data-start=\"1788\" data-end=\"1791\"\u003eEMFC weighing technology\u003cbr data-start=\"1815\" data-end=\"1818\"\u003eInternal automatic calibration\u003cbr data-start=\"1848\" data-end=\"1851\"\u003e4.3-inch touchscreen display\u003cbr data-start=\"1879\" data-end=\"1882\"\u003eGLP \/ GMP compliant operation\u003cbr data-start=\"1911\" data-end=\"1914\"\u003eMultiple weighing modes\u003cbr data-start=\"1937\" data-end=\"1940\"\u003eBuilt-in temperature sensor\u003cbr data-start=\"1967\" data-end=\"1970\"\u003eGlass antistatic windshield\u003cbr data-start=\"1997\" data-end=\"2000\"\u003eFast sensitivity adjustment\u003cbr data-start=\"2027\" data-end=\"2030\"\u003eRS232C and USB communication\u003cbr data-start=\"2058\" data-end=\"2061\"\u003eDensity determination capability\u003cbr data-start=\"2093\" data-end=\"2096\"\u003eContinuous and command output modes\u003c\/p\u003e\n\u003ch3 data-start=\"2135\" data-end=\"2162\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"2164\" data-end=\"3090\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"2164\" data-end=\"2193\"\u003e\n\u003ctr data-start=\"2164\" data-end=\"2193\"\u003e\n\u003cth data-start=\"2164\" data-end=\"2176\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth data-start=\"2176\" data-end=\"2193\" data-col-size=\"md\" class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"2204\" data-end=\"3090\"\u003e\n\u003ctr data-start=\"2204\" data-end=\"2231\"\u003e\n\u003ctd data-start=\"2204\" data-end=\"2215\" data-col-size=\"sm\"\u003eCapacity\u003c\/td\u003e\n\u003ctd data-start=\"2215\" data-end=\"2231\" data-col-size=\"md\"\u003e81 g \/ 220 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2232\" data-end=\"2266\"\u003e\n\u003ctd data-start=\"2232\" data-end=\"2246\" data-col-size=\"sm\"\u003eReadability\u003c\/td\u003e\n\u003ctd data-start=\"2246\" data-end=\"2266\" data-col-size=\"md\"\u003e0.01 mg \/ 0.1 mg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2267\" data-end=\"2303\"\u003e\n\u003ctd data-start=\"2267\" data-end=\"2283\" data-col-size=\"sm\"\u003eRepeatability\u003c\/td\u003e\n\u003ctd data-start=\"2283\" data-end=\"2303\" data-col-size=\"md\"\u003e0.01 mg \/ 0.1 mg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2304\" data-end=\"2338\"\u003e\n\u003ctd data-start=\"2304\" data-end=\"2316\" data-col-size=\"sm\"\u003eLinearity\u003c\/td\u003e\n\u003ctd data-start=\"2316\" data-end=\"2338\" data-col-size=\"md\"\u003e±0.04 mg \/ ±0.4 mg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2339\" data-end=\"2381\"\u003e\n\u003ctd data-start=\"2339\" data-end=\"2373\" data-col-size=\"sm\"\u003eVerification Scale Interval (e)\u003c\/td\u003e\n\u003ctd data-start=\"2373\" data-end=\"2381\" data-col-size=\"md\"\u003e1 mg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2382\" data-end=\"2420\"\u003e\n\u003ctd data-start=\"2382\" data-end=\"2396\" data-col-size=\"sm\"\u003eCalibration\u003c\/td\u003e\n\u003ctd data-start=\"2396\" data-end=\"2420\" data-col-size=\"md\"\u003eInternal Calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2421\" data-end=\"2449\"\u003e\n\u003ctd data-start=\"2421\" data-end=\"2438\" data-col-size=\"sm\"\u003eAccuracy Class\u003c\/td\u003e\n\u003ctd data-start=\"2438\" data-end=\"2449\" data-col-size=\"md\"\u003eClass I\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2450\" data-end=\"2484\"\u003e\n\u003ctd data-start=\"2450\" data-end=\"2460\" data-col-size=\"sm\"\u003eDisplay\u003c\/td\u003e\n\u003ctd data-start=\"2460\" data-end=\"2484\" data-col-size=\"md\"\u003eTouch Screen Display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2485\" data-end=\"2512\"\u003e\n\u003ctd data-start=\"2485\" data-end=\"2501\" data-col-size=\"sm\"\u003eResponse Time\u003c\/td\u003e\n\u003ctd data-start=\"2501\" data-end=\"2512\" data-col-size=\"md\"\u003e4–6 sec\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2513\" data-end=\"2535\"\u003e\n\u003ctd data-start=\"2513\" data-end=\"2524\" data-col-size=\"sm\"\u003ePan Size\u003c\/td\u003e\n\u003ctd data-start=\"2524\" data-end=\"2535\" data-col-size=\"md\"\u003e90 mm Ø\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2536\" data-end=\"2557\"\u003e\n\u003ctd data-start=\"2536\" data-end=\"2549\" data-col-size=\"sm\"\u003eTare Range\u003c\/td\u003e\n\u003ctd data-start=\"2549\" data-end=\"2557\" data-col-size=\"md\"\u003eFull\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2558\" data-end=\"2598\"\u003e\n\u003ctd data-start=\"2558\" data-end=\"2582\" data-col-size=\"sm\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd data-start=\"2582\" data-end=\"2598\" data-col-size=\"md\"\u003e15°C to 30°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2599\" data-end=\"2633\"\u003e\n\u003ctd data-start=\"2599\" data-end=\"2619\" data-col-size=\"sm\"\u003eSensitivity Drift\u003c\/td\u003e\n\u003ctd data-start=\"2619\" data-end=\"2633\" data-col-size=\"md\"\u003e2 ppm \/ °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2634\" data-end=\"2666\"\u003e\n\u003ctd data-start=\"2634\" data-end=\"2653\" data-col-size=\"sm\"\u003eDensity Function\u003c\/td\u003e\n\u003ctd data-start=\"2653\" data-end=\"2666\" data-col-size=\"md\"\u003eAvailable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2667\" data-end=\"2717\"\u003e\n\u003ctd data-start=\"2667\" data-end=\"2686\" data-col-size=\"sm\"\u003eData Output Mode\u003c\/td\u003e\n\u003ctd data-start=\"2686\" data-end=\"2717\" data-col-size=\"md\"\u003eCommand \u0026amp; Continuous Output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2718\" data-end=\"2747\"\u003e\n\u003ctd data-start=\"2718\" data-end=\"2734\" data-col-size=\"sm\"\u003eFactory Reset\u003c\/td\u003e\n\u003ctd data-start=\"2734\" data-end=\"2747\" data-col-size=\"md\"\u003eAvailable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2748\" data-end=\"2794\"\u003e\n\u003ctd data-start=\"2748\" data-end=\"2772\" data-col-size=\"sm\"\u003eWeighing Chamber Size\u003c\/td\u003e\n\u003ctd data-start=\"2772\" data-end=\"2794\" data-col-size=\"md\"\u003e162 × 180 × 210 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2795\" data-end=\"2820\"\u003e\n\u003ctd data-start=\"2795\" data-end=\"2803\" data-col-size=\"sm\"\u003eUnits\u003c\/td\u003e\n\u003ctd data-start=\"2803\" data-end=\"2820\" data-col-size=\"md\"\u003eg, mg, oz, ct\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2821\" data-end=\"2908\"\u003e\n\u003ctd data-start=\"2821\" data-end=\"2841\" data-col-size=\"sm\"\u003eApplication Modes\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2841\" data-end=\"2908\"\u003eBasic, Dynamic, Percentage, Piece Counting, Density, Σ Weighing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2909\" data-end=\"2947\"\u003e\n\u003ctd data-start=\"2909\" data-end=\"2921\" data-col-size=\"sm\"\u003eBaud Rate\u003c\/td\u003e\n\u003ctd data-start=\"2921\" data-end=\"2947\" data-col-size=\"md\"\u003e1200, 2400, 4800, 9600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2948\" data-end=\"2975\"\u003e\n\u003ctd data-start=\"2948\" data-end=\"2960\" data-col-size=\"sm\"\u003eInterface\u003c\/td\u003e\n\u003ctd data-start=\"2960\" data-end=\"2975\" data-col-size=\"md\"\u003eRS232C, USB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2976\" data-end=\"3028\"\u003e\n\u003ctd data-start=\"2976\" data-end=\"2991\" data-col-size=\"sm\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd data-start=\"2991\" data-end=\"3028\" data-col-size=\"md\"\u003eDC 9V Adapter, AC 220V \/ 50–60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3029\" data-end=\"3072\"\u003e\n\u003ctd data-start=\"3029\" data-end=\"3050\" data-col-size=\"sm\"\u003eDimensions (L×W×H)\u003c\/td\u003e\n\u003ctd data-start=\"3050\" data-end=\"3072\" data-col-size=\"md\"\u003e420 × 315 × 445 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3073\" data-end=\"3090\"\u003e\n\u003ctd data-start=\"3073\" data-end=\"3082\" data-col-size=\"sm\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-start=\"3082\" data-end=\"3090\" data-col-size=\"md\"\u003e9 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 data-start=\"3092\" data-end=\"3107\"\u003eApplications\u003c\/h3\u003e\n\u003cp data-start=\"3109\" data-end=\"3356\"\u003eAnalytical laboratory weighing\u003cbr data-start=\"3139\" data-end=\"3142\"\u003eSemi-micro precision measurement\u003cbr data-start=\"3174\" data-end=\"3177\"\u003ePharmaceutical and QC laboratories\u003cbr data-start=\"3211\" data-end=\"3214\"\u003eResearch and academic institutions\u003cbr data-start=\"3248\" data-end=\"3251\"\u003eDensity determination workflows\u003cbr data-start=\"3282\" data-end=\"3285\"\u003eSample preparation and formulation\u003cbr data-start=\"3319\" data-end=\"3322\"\u003eHigh-accuracy analytical testing\u003c\/p\u003e","brand":"Wensar","offers":[{"title":"Default Title","offer_id":50011062010093,"sku":null,"price":0.0,"currency_code":"INR","in_stock":true}],"url":"https:\/\/www.biotronscientific.com\/products\/semi-micro-analytical-balance-tab10t-81-220g-capacity-internal-calibration","provider":"BIOTRON","version":"1.0","type":"link"}