{"product_id":"semi-automatic-microtome-arm-300","title":"Semi Automatic Microtome ARM – 300","description":"\u003cp data-start=\"125\" data-end=\"794\"\u003eSemi Automatic Microtome ARM-300 is a high-precision sectioning instrument designed for clinical histology, histopathology, and research applications. It combines manual control with motorized precision using stepping motor technology, ensuring accurate and consistent sectioning across a wide thickness range. The system features an ergonomic design, smooth handwheel operation, and intuitive digital interface displaying all critical parameters such as section thickness, trimming values, and section count. With advanced specimen retraction, cross roller guidance, and safety-focused design, it delivers reliable performance for routine and advanced laboratory work.\u003c\/p\u003e\n\u003ch3 data-start=\"796\" data-end=\"813\"\u003eKey Features\u003c\/h3\u003e\n\u003cp data-start=\"814\" data-end=\"1673\"\u003eSemi-automatic operation with precision stepping motor technology\u003cbr data-start=\"879\" data-end=\"882\"\u003eSection thickness range from 0.5 to 100 microns\u003cbr data-start=\"929\" data-end=\"932\"\u003eDigital display for section thickness, trimming and section count\u003cbr data-start=\"997\" data-end=\"1000\"\u003eSpecimen retraction during return travel with adjustable range\u003cbr data-start=\"1062\" data-end=\"1065\"\u003eSmooth hand wheel with low resistance operation\u003cbr data-start=\"1112\" data-end=\"1115\"\u003eQuick clamp system for easy specimen change\u003cbr data-start=\"1158\" data-end=\"1161\" data-is-only-node=\"\"\u003eCross roller bearings with zero-backlash for high precision\u003cbr data-start=\"1220\" data-end=\"1223\"\u003eVariable speed control for specimen feed\u003cbr data-start=\"1263\" data-end=\"1266\"\u003eLarge section waste tray covering full working area\u003cbr data-start=\"1317\" data-end=\"1320\"\u003eErgonomic design for long duration, fatigue-free operation\u003cbr data-start=\"1378\" data-end=\"1381\"\u003e360° specimen orientation with fine adjustment control\u003cbr data-start=\"1435\" data-end=\"1438\"\u003eAdvanced safety and operational design for reliable use\u003cbr data-start=\"1493\" data-end=\"1496\"\u003eDifferentiator vs ARM-200: Motorized feed with digital control and automated functions\u003cbr data-start=\"1582\" data-end=\"1585\"\u003eBest for: histopathology labs, clinical labs, research institutes and medical colleges\u003c\/p\u003e\n\u003ch3 data-start=\"1675\" data-end=\"1704\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"1705\" data-end=\"2494\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"1705\" data-end=\"1734\"\u003e\n\u003ctr data-start=\"1705\" data-end=\"1734\"\u003e\n\u003cth data-start=\"1705\" data-end=\"1717\" data-col-size=\"sm\" class=\"\"\u003eParameter\u003c\/th\u003e\n\u003cth data-start=\"1717\" data-end=\"1734\" data-col-size=\"md\" class=\"\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"1745\" data-end=\"2494\"\u003e\n\u003ctr data-start=\"1745\" data-end=\"1791\"\u003e\n\u003ctd data-start=\"1745\" data-end=\"1763\" data-col-size=\"sm\"\u003eInstrument Type\u003c\/td\u003e\n\u003ctd data-start=\"1763\" data-end=\"1791\" data-col-size=\"md\"\u003eSemi Automatic Microtome\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1792\" data-end=\"1811\"\u003e\n\u003ctd data-start=\"1792\" data-end=\"1800\" data-col-size=\"sm\"\u003eModel\u003c\/td\u003e\n\u003ctd data-start=\"1800\" data-end=\"1811\" data-col-size=\"md\"\u003eARM-300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1812\" data-end=\"1854\"\u003e\n\u003ctd data-start=\"1812\" data-end=\"1838\" data-col-size=\"sm\"\u003eSection Thickness Range\u003c\/td\u003e\n\u003ctd data-start=\"1838\" data-end=\"1854\" data-col-size=\"md\"\u003e0.5 – 100 µm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1855\" data-end=\"1908\"\u003e\n\u003ctd data-start=\"1855\" data-end=\"1869\" data-col-size=\"sm\"\u003eFeed System\u003c\/td\u003e\n\u003ctd data-start=\"1869\" data-end=\"1908\" data-col-size=\"md\"\u003eStepping motor based precision feed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1909\" data-end=\"1939\"\u003e\n\u003ctd data-start=\"1909\" data-end=\"1921\" data-col-size=\"sm\"\u003eOperation\u003c\/td\u003e\n\u003ctd data-start=\"1921\" data-end=\"1939\" data-col-size=\"md\"\u003eSemi-automatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1940\" data-end=\"1988\"\u003e\n\u003ctd data-start=\"1940\" data-end=\"1962\" data-col-size=\"sm\"\u003eSpecimen Retraction\u003c\/td\u003e\n\u003ctd data-start=\"1962\" data-end=\"1988\" data-col-size=\"md\"\u003e0 – 200 µm, selectable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1989\" data-end=\"2024\"\u003e\n\u003ctd data-start=\"1989\" data-end=\"2007\" data-col-size=\"sm\"\u003eHorizontal Feed\u003c\/td\u003e\n\u003ctd data-start=\"2007\" data-end=\"2024\" data-col-size=\"md\"\u003eApprox. 30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2025\" data-end=\"2058\"\u003e\n\u003ctd data-start=\"2025\" data-end=\"2041\" data-col-size=\"sm\"\u003eVertical Feed\u003c\/td\u003e\n\u003ctd data-start=\"2041\" data-end=\"2058\" data-col-size=\"md\"\u003eApprox. 60 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2059\" data-end=\"2112\"\u003e\n\u003ctd data-start=\"2059\" data-end=\"2077\" data-col-size=\"sm\"\u003eSectioning Mode\u003c\/td\u003e\n\u003ctd data-start=\"2077\" data-end=\"2112\" data-col-size=\"md\"\u003eManual mode with motorized feed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2113\" data-end=\"2179\"\u003e\n\u003ctd data-start=\"2113\" data-end=\"2136\" data-col-size=\"sm\"\u003eSpecimen Orientation\u003c\/td\u003e\n\u003ctd data-start=\"2136\" data-end=\"2179\" data-col-size=\"md\"\u003eHorizontal 8°, Vertical 8°, Z-axis 360°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2180\" data-end=\"2214\"\u003e\n\u003ctd data-start=\"2180\" data-end=\"2200\" data-col-size=\"sm\"\u003eMax Specimen Size\u003c\/td\u003e\n\u003ctd data-start=\"2200\" data-end=\"2214\" data-col-size=\"md\"\u003e50 × 50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2215\" data-end=\"2238\"\u003e\n\u003ctd data-start=\"2215\" data-end=\"2229\" data-col-size=\"sm\"\u003eObject Feed\u003c\/td\u003e\n\u003ctd data-start=\"2229\" data-end=\"2238\" data-col-size=\"md\"\u003e28 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2239\" data-end=\"2278\"\u003e\n\u003ctd data-start=\"2239\" data-end=\"2249\" data-col-size=\"sm\"\u003eDisplay\u003c\/td\u003e\n\u003ctd data-start=\"2249\" data-end=\"2278\" data-col-size=\"md\"\u003eDigital parameter display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2279\" data-end=\"2315\"\u003e\n\u003ctd data-start=\"2279\" data-end=\"2289\" data-col-size=\"sm\"\u003eVoltage\u003c\/td\u003e\n\u003ctd data-start=\"2289\" data-end=\"2315\" data-col-size=\"md\"\u003e220V\/50Hz or 110V\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2316\" data-end=\"2356\"\u003e\n\u003ctd data-start=\"2316\" data-end=\"2331\" data-col-size=\"sm\"\u003eGuide System\u003c\/td\u003e\n\u003ctd data-start=\"2331\" data-end=\"2356\" data-col-size=\"md\"\u003eCross roller bearings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2357\" data-end=\"2405\"\u003e\n\u003ctd data-start=\"2357\" data-end=\"2371\" data-col-size=\"sm\"\u003eApplication\u003c\/td\u003e\n\u003ctd data-start=\"2371\" data-end=\"2405\" data-col-size=\"md\"\u003eHistology, pathology, research\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2406\" data-end=\"2464\"\u003e\n\u003ctd data-start=\"2406\" data-end=\"2414\" data-col-size=\"sm\"\u003eUsage\u003c\/td\u003e\n\u003ctd data-start=\"2414\" data-end=\"2464\" data-col-size=\"md\"\u003eClinical labs, medical colleges, research labs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2465\" data-end=\"2494\"\u003e\n\u003ctd data-start=\"2465\" data-end=\"2485\" data-col-size=\"sm\"\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd data-start=\"2485\" data-end=\"2494\" data-col-size=\"md\"\u003eIndia\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"ALMICRO","offers":[{"title":"Default Title","offer_id":49431337959661,"sku":null,"price":1486800.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5672\/6765\/files\/ARM300.png?v=1774618372","url":"https:\/\/www.biotronscientific.com\/products\/semi-automatic-microtome-arm-300","provider":"BIOTRON","version":"1.0","type":"link"}