{"product_id":"potential-titrator-apt1800-det-met-set-mat-0-01-ph-accuracy","title":"Potential Titrator APT1800 (DET\/MET\/SET\/MAT, ±0.01 pH Accuracy)","description":"\u003cp data-start=\"285\" data-end=\"1030\"\u003eAutomatic Potential Titrator APT1800 is designed for precise and automated titration analysis in laboratory environments. It supports multiple titration modes including dynamic equivalence point, monotone equivalence point, preset endpoint and manual titration, enabling flexibility across different analytical methods. The system features a high-accuracy burette with selectable volumes, ensuring precise reagent delivery. With integrated pH and mV measurement capabilities, temperature compensation and data storage, it delivers reliable and repeatable results. The LCD interface provides detailed visualization of titration curves and results, while connectivity options allow seamless data transfer and integration into laboratory workflows.\u003c\/p\u003e\n\u003ch3 data-start=\"1032\" data-end=\"1049\"\u003eKey Features\u003c\/h3\u003e\n\u003cp data-start=\"1050\" data-end=\"1680\"\u003eSupports DET, MET, SET and MAT titration modes\u003cbr data-start=\"1096\" data-end=\"1099\"\u003eHigh precision burette system with selectable 10 ml and 20 ml options\u003cbr data-start=\"1168\" data-end=\"1171\"\u003eAccurate pH and mV measurement with fine resolution\u003cbr data-start=\"1222\" data-end=\"1225\"\u003eLCD display for real-time curve and result visualization\u003cbr data-start=\"1281\" data-end=\"1284\"\u003eAutomatic titration with repeatable and consistent results\u003cbr data-start=\"1342\" data-end=\"1345\"\u003eData storage up to 50 titration sets\u003cbr data-start=\"1381\" data-end=\"1384\"\u003eIntegrated stirring function for uniform mixing\u003cbr data-start=\"1431\" data-end=\"1434\"\u003eTemperature measurement and compensation support\u003cbr data-start=\"1482\" data-end=\"1485\"\u003eRS232 and USB interface for data connectivity\u003cbr data-start=\"1530\" data-end=\"1533\"\u003eHigh resolution dosing mechanism for precise control\u003cbr data-start=\"1585\" data-end=\"1588\"\u003eGMP compliant data handling system\u003cbr data-start=\"1622\" data-end=\"1625\"\u003eSuitable for automated analytical titration workflows\u003c\/p\u003e\n\u003ch3 data-start=\"1682\" data-end=\"1711\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"1712\" data-end=\"2584\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"1712\" data-end=\"1741\"\u003e\n\u003ctr data-start=\"1712\" data-end=\"1741\"\u003e\n\u003cth data-start=\"1712\" data-end=\"1724\" data-col-size=\"sm\" class=\"\"\u003eParameter\u003c\/th\u003e\n\u003cth data-start=\"1724\" data-end=\"1741\" data-col-size=\"md\" class=\"\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"1752\" data-end=\"2584\"\u003e\n\u003ctr data-start=\"1752\" data-end=\"1801\"\u003e\n\u003ctd data-start=\"1752\" data-end=\"1769\" data-col-size=\"sm\"\u003eEquipment Type\u003c\/td\u003e\n\u003ctd data-start=\"1769\" data-end=\"1801\" data-col-size=\"md\"\u003eAutomatic Potential Titrator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1802\" data-end=\"1821\"\u003e\n\u003ctd data-start=\"1802\" data-end=\"1810\" data-col-size=\"sm\"\u003eModel\u003c\/td\u003e\n\u003ctd data-start=\"1810\" data-end=\"1821\" data-col-size=\"md\"\u003eAPT1800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1822\" data-end=\"1862\"\u003e\n\u003ctd data-start=\"1822\" data-end=\"1840\" data-col-size=\"sm\"\u003eTitration Modes\u003c\/td\u003e\n\u003ctd data-start=\"1840\" data-end=\"1862\" data-col-size=\"md\"\u003eDET, MET, SET, MAT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1863\" data-end=\"1903\"\u003e\n\u003ctd data-start=\"1863\" data-end=\"1890\" data-col-size=\"sm\"\u003eBurette Accuracy (10 ml)\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"1890\" data-end=\"1903\"\u003e±0.025 ml\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1904\" data-end=\"1944\"\u003e\n\u003ctd data-start=\"1904\" data-end=\"1931\" data-col-size=\"sm\"\u003eBurette Accuracy (20 ml)\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"1931\" data-end=\"1944\"\u003e±0.035 ml\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1945\" data-end=\"1981\"\u003e\n\u003ctd data-start=\"1945\" data-end=\"1966\" data-col-size=\"sm\"\u003eBurette Resolution\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"1966\" data-end=\"1981\"\u003e1 µl \/ 2 µl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1982\" data-end=\"2006\"\u003e\n\u003ctd data-start=\"1982\" data-end=\"1998\" data-col-size=\"sm\"\u003eRepeatability\u003c\/td\u003e\n\u003ctd data-start=\"1998\" data-end=\"2006\" data-col-size=\"md\"\u003e0.2%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2007\" data-end=\"2032\"\u003e\n\u003ctd data-start=\"2007\" data-end=\"2018\" data-col-size=\"sm\"\u003emV Range\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2018\" data-end=\"2032\"\u003e±1800.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2033\" data-end=\"2059\"\u003e\n\u003ctd data-start=\"2033\" data-end=\"2049\" data-col-size=\"sm\"\u003emV Resolution\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2049\" data-end=\"2059\"\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2060\" data-end=\"2087\"\u003e\n\u003ctd data-start=\"2060\" data-end=\"2074\" data-col-size=\"sm\"\u003emV Accuracy\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2074\" data-end=\"2087\"\u003e±0.05% FS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2088\" data-end=\"2118\"\u003e\n\u003ctd data-start=\"2088\" data-end=\"2099\" data-col-size=\"sm\"\u003epH Range\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2099\" data-end=\"2118\"\u003e0.00 – 14.00 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2119\" data-end=\"2146\"\u003e\n\u003ctd data-start=\"2119\" data-end=\"2135\" data-col-size=\"sm\"\u003epH Resolution\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2135\" data-end=\"2146\"\u003e0.01 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2147\" data-end=\"2173\"\u003e\n\u003ctd data-start=\"2147\" data-end=\"2161\" data-col-size=\"sm\"\u003epH Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"2161\" data-end=\"2173\" data-col-size=\"md\"\u003e±0.01 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2174\" data-end=\"2209\"\u003e\n\u003ctd data-start=\"2174\" data-end=\"2194\" data-col-size=\"sm\"\u003eTemperature Range\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2194\" data-end=\"2209\"\u003eUp to 105°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2210\" data-end=\"2244\"\u003e\n\u003ctd data-start=\"2210\" data-end=\"2235\" data-col-size=\"sm\"\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2235\" data-end=\"2244\"\u003e0.1°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2245\" data-end=\"2278\"\u003e\n\u003ctd data-start=\"2245\" data-end=\"2268\" data-col-size=\"sm\"\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"2268\" data-end=\"2278\" data-col-size=\"md\"\u003e±0.3°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2279\" data-end=\"2296\"\u003e\n\u003ctd data-start=\"2279\" data-end=\"2289\" data-col-size=\"sm\"\u003eDisplay\u003c\/td\u003e\n\u003ctd data-start=\"2289\" data-end=\"2296\" data-col-size=\"md\"\u003eLCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2297\" data-end=\"2324\"\u003e\n\u003ctd data-start=\"2297\" data-end=\"2317\" data-col-size=\"sm\"\u003eStirring Function\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2317\" data-end=\"2324\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2325\" data-end=\"2351\"\u003e\n\u003ctd data-start=\"2325\" data-end=\"2340\" data-col-size=\"sm\"\u003eData Storage\u003c\/td\u003e\n\u003ctd data-start=\"2340\" data-end=\"2351\" data-col-size=\"md\"\u003e50 sets\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2352\" data-end=\"2383\"\u003e\n\u003ctd data-start=\"2352\" data-end=\"2368\" data-col-size=\"sm\"\u003eCommunication\u003c\/td\u003e\n\u003ctd data-start=\"2368\" data-end=\"2383\" data-col-size=\"md\"\u003eRS232C, USB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2384\" data-end=\"2417\"\u003e\n\u003ctd data-start=\"2384\" data-end=\"2399\" data-col-size=\"sm\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd data-start=\"2399\" data-end=\"2417\" data-col-size=\"md\"\u003eAC 220V \/ 50Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2418\" data-end=\"2453\"\u003e\n\u003ctd data-start=\"2418\" data-end=\"2431\" data-col-size=\"sm\"\u003eDimensions\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2431\" data-end=\"2453\"\u003e540 × 495 × 480 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2454\" data-end=\"2480\"\u003e\n\u003ctd data-start=\"2454\" data-end=\"2463\" data-col-size=\"sm\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2463\" data-end=\"2480\"\u003eApprox. 10 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2481\" data-end=\"2527\"\u003e\n\u003ctd data-start=\"2481\" data-end=\"2495\" data-col-size=\"sm\"\u003eApplication\u003c\/td\u003e\n\u003ctd data-start=\"2495\" data-end=\"2527\" data-col-size=\"md\"\u003eAutomated titration analysis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2528\" data-end=\"2584\"\u003e\n\u003ctd data-start=\"2528\" data-end=\"2536\" data-col-size=\"sm\"\u003eUsage\u003c\/td\u003e\n\u003ctd data-start=\"2536\" data-end=\"2584\" data-col-size=\"md\"\u003eChemical analysis, quality control workflows\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Labman","offers":[{"title":"Default Title","offer_id":49822427644141,"sku":null,"price":0.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5672\/6765\/files\/APT1800.webp?v=1776975169","url":"https:\/\/www.biotronscientific.com\/products\/potential-titrator-apt1800-det-met-set-mat-0-01-ph-accuracy","provider":"BIOTRON","version":"1.0","type":"link"}