{"product_id":"moisture-analyzer-lmb16-160g-capacity-1mg-readability-halogen-heating-graphic-display","title":"Moisture Analyzer – LMB16 (160g Capacity | 1mg Readability | Halogen Heating \u0026 Graphic Display)","description":"\u003cp data-start=\"137\" data-end=\"537\"\u003eLMB16 Moisture Analyzer is a precision laboratory moisture determination instrument designed for fast, reliable and repeatable moisture analysis across research, industrial and quality control environments. Combining loadcell-based weighing technology with halogen heating, the analyzer delivers accurate moisture percentage and dry residue measurements for routine and advanced laboratory workflows.\u003c\/p\u003e\n\u003cp data-start=\"539\" data-end=\"871\"\u003eThe instrument offers a 160 g capacity with 1 mg readability, supported by a large graphic display with backlight for clear parameter monitoring and result visualization. Its dual operating profiles—Standard and Rapid—allow users to optimize testing speed and sample heating conditions according to application requirements.\u003c\/p\u003e\n\u003cp data-start=\"873\" data-end=\"1170\"\u003eLMB16 features automatic external calibration, configurable temperature settings from 40°C to 160°C, moisture result reporting and integrated GLP\/ISO record management for calibration traceability. RS232C connectivity enables efficient data export and documentation for regulated environments.\u003c\/p\u003e\n\u003cp data-start=\"1172\" data-end=\"1348\"\u003eDesigned for scientific laboratories and industrial process monitoring, LMB16 supports dependable moisture analysis with user-friendly operation and multilingual functionality.\u003c\/p\u003e\n\u003ch3 data-start=\"1350\" data-end=\"1364\"\u003eKey Features\u003c\/h3\u003e\n\u003cp data-start=\"1366\" data-end=\"1775\"\u003eHalogen heating system\u003cbr data-start=\"1388\" data-end=\"1391\"\u003eLarge graphic display with backlight\u003cbr data-start=\"1427\" data-end=\"1430\"\u003eLoadcell-based weighing technology\u003cbr data-start=\"1464\" data-end=\"1467\"\u003eGLP \/ ISO record of stored calibration data\u003cbr data-start=\"1510\" data-end=\"1513\"\u003eDual heating modes – Standard and Rapid\u003cbr data-start=\"1552\" data-end=\"1555\"\u003eTemperature range from 40°C to 160°C\u003cbr data-start=\"1591\" data-end=\"1594\"\u003eRS232C communication interface\u003cbr data-start=\"1624\" data-end=\"1627\"\u003eMulti-language support\u003cbr data-start=\"1649\" data-end=\"1652\"\u003ePre-heating on\/off function\u003cbr data-start=\"1679\" data-end=\"1682\"\u003eDate and time function\u003cbr data-start=\"1704\" data-end=\"1707\"\u003eAutomatic external calibration\u003cbr data-start=\"1737\" data-end=\"1740\"\u003eMoisture and dry residue analysis\u003c\/p\u003e\n\u003ch3 data-start=\"1777\" data-end=\"1803\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"1805\" data-end=\"2691\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"1805\" data-end=\"1834\"\u003e\n\u003ctr data-start=\"1805\" data-end=\"1834\"\u003e\n\u003cth data-start=\"1805\" data-end=\"1817\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth data-start=\"1817\" data-end=\"1834\" data-col-size=\"md\" class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"1845\" data-end=\"2691\"\u003e\n\u003ctr data-start=\"1845\" data-end=\"1862\"\u003e\n\u003ctd data-start=\"1845\" data-end=\"1853\" data-col-size=\"sm\"\u003eModel\u003c\/td\u003e\n\u003ctd data-start=\"1853\" data-end=\"1862\" data-col-size=\"md\"\u003eLMB16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1863\" data-end=\"1883\"\u003e\n\u003ctd data-start=\"1863\" data-end=\"1874\" data-col-size=\"sm\"\u003eCapacity\u003c\/td\u003e\n\u003ctd data-start=\"1874\" data-end=\"1883\" data-col-size=\"md\"\u003e160 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1884\" data-end=\"1916\"\u003e\n\u003ctd data-start=\"1884\" data-end=\"1898\" data-col-size=\"sm\"\u003eReadability\u003c\/td\u003e\n\u003ctd data-start=\"1898\" data-end=\"1916\" data-col-size=\"md\"\u003e0.001 g (1 mg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1917\" data-end=\"1951\"\u003e\n\u003ctd data-start=\"1917\" data-end=\"1933\" data-col-size=\"sm\"\u003eRepeatability\u003c\/td\u003e\n\u003ctd data-start=\"1933\" data-end=\"1951\" data-col-size=\"md\"\u003e0.001 g (1 mg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1952\" data-end=\"1979\"\u003e\n\u003ctd data-start=\"1952\" data-end=\"1968\" data-col-size=\"sm\"\u003eLinearity (±)\u003c\/td\u003e\n\u003ctd data-start=\"1968\" data-end=\"1979\" data-col-size=\"md\"\u003e0.002 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1980\" data-end=\"2025\"\u003e\n\u003ctd data-start=\"1980\" data-end=\"1990\" data-col-size=\"sm\"\u003eDisplay\u003c\/td\u003e\n\u003ctd data-start=\"1990\" data-end=\"2025\" data-col-size=\"md\"\u003eGraphic Display with Back Light\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2026\" data-end=\"2087\"\u003e\n\u003ctd data-start=\"2026\" data-end=\"2044\" data-col-size=\"sm\"\u003eDisplay Results\u003c\/td\u003e\n\u003ctd data-start=\"2044\" data-end=\"2087\" data-col-size=\"md\"\u003eMoisture %, Dry Residue %, ATRO, Weight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2088\" data-end=\"2199\"\u003e\n\u003ctd data-start=\"2088\" data-end=\"2107\" data-col-size=\"sm\"\u003ePrintout Results\u003c\/td\u003e\n\u003ctd data-start=\"2107\" data-end=\"2199\" data-col-size=\"md\"\u003eDate, Time, Instrument ID, User ID, Project ID, Temperature, Mode, Moisture %, Signature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2200\" data-end=\"2221\"\u003e\n\u003ctd data-start=\"2200\" data-end=\"2211\" data-col-size=\"sm\"\u003ePan Size\u003c\/td\u003e\n\u003ctd data-start=\"2211\" data-end=\"2221\" data-col-size=\"md\"\u003e100 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2222\" data-end=\"2243\"\u003e\n\u003ctd data-start=\"2222\" data-end=\"2231\" data-col-size=\"sm\"\u003eSensor\u003c\/td\u003e\n\u003ctd data-start=\"2231\" data-end=\"2243\" data-col-size=\"md\"\u003eLoadcell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2244\" data-end=\"2280\"\u003e\n\u003ctd data-start=\"2244\" data-end=\"2258\" data-col-size=\"sm\"\u003eCalibration\u003c\/td\u003e\n\u003ctd data-start=\"2258\" data-end=\"2280\" data-col-size=\"md\"\u003eAutomatic External\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2281\" data-end=\"2317\"\u003e\n\u003ctd data-start=\"2281\" data-end=\"2305\" data-col-size=\"sm\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd data-start=\"2305\" data-end=\"2317\" data-col-size=\"md\"\u003e5°C–35°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2318\" data-end=\"2351\"\u003e\n\u003ctd data-start=\"2318\" data-end=\"2335\" data-col-size=\"sm\"\u003eHeating Source\u003c\/td\u003e\n\u003ctd data-start=\"2335\" data-end=\"2351\" data-col-size=\"md\"\u003eHalogen Lamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2352\" data-end=\"2374\"\u003e\n\u003ctd data-start=\"2352\" data-end=\"2364\" data-col-size=\"sm\"\u003eInterface\u003c\/td\u003e\n\u003ctd data-start=\"2364\" data-end=\"2374\" data-col-size=\"md\"\u003eRS232C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2375\" data-end=\"2420\"\u003e\n\u003ctd data-start=\"2375\" data-end=\"2398\" data-col-size=\"sm\"\u003eTemperature Profiles\u003c\/td\u003e\n\u003ctd data-start=\"2398\" data-end=\"2420\" data-col-size=\"md\"\u003eStandard and Rapid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2421\" data-end=\"2457\"\u003e\n\u003ctd data-start=\"2421\" data-end=\"2443\" data-col-size=\"sm\"\u003eTemperature Setting\u003c\/td\u003e\n\u003ctd data-start=\"2443\" data-end=\"2457\" data-col-size=\"md\"\u003e40°C–160°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2458\" data-end=\"2484\"\u003e\n\u003ctd data-start=\"2458\" data-end=\"2477\" data-col-size=\"sm\"\u003eTemperature Step\u003c\/td\u003e\n\u003ctd data-start=\"2477\" data-end=\"2484\" data-col-size=\"md\"\u003e1°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2485\" data-end=\"2523\"\u003e\n\u003ctd data-start=\"2485\" data-end=\"2500\" data-col-size=\"sm\"\u003eTime Setting\u003c\/td\u003e\n\u003ctd data-start=\"2500\" data-end=\"2523\" data-col-size=\"md\"\u003e1–99 min \/ Autostop\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2524\" data-end=\"2551\"\u003e\n\u003ctd data-start=\"2524\" data-end=\"2542\" data-col-size=\"sm\"\u003eDry Readability\u003c\/td\u003e\n\u003ctd data-start=\"2542\" data-end=\"2551\" data-col-size=\"md\"\u003e0.01%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2552\" data-end=\"2585\"\u003e\n\u003ctd data-start=\"2552\" data-end=\"2575\" data-col-size=\"sm\"\u003eAluminium Sample Pan\u003c\/td\u003e\n\u003ctd data-start=\"2575\" data-end=\"2585\" data-col-size=\"md\"\u003e10 pcs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2586\" data-end=\"2623\"\u003e\n\u003ctd data-start=\"2586\" data-end=\"2601\" data-col-size=\"sm\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd data-start=\"2601\" data-end=\"2623\" data-col-size=\"md\"\u003eAC 220V \/ 50–60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2624\" data-end=\"2667\"\u003e\n\u003ctd data-start=\"2624\" data-end=\"2645\" data-col-size=\"sm\"\u003eDimensions (L×W×H)\u003c\/td\u003e\n\u003ctd data-start=\"2645\" data-end=\"2667\" data-col-size=\"md\"\u003e450 × 280 × 390 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2668\" data-end=\"2691\"\u003e\n\u003ctd data-start=\"2668\" data-end=\"2683\" data-col-size=\"sm\"\u003eGross Weight\u003c\/td\u003e\n\u003ctd data-start=\"2683\" data-end=\"2691\" data-col-size=\"md\"\u003e7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 data-start=\"2693\" data-end=\"2707\"\u003eApplications\u003c\/h3\u003e\n\u003cp data-start=\"2709\" data-end=\"3068\"\u003eMoisture determination laboratories\u003cbr data-start=\"2744\" data-end=\"2747\"\u003eFood and beverage testing\u003cbr data-start=\"2772\" data-end=\"2775\"\u003eAgriculture and grain analysis\u003cbr data-start=\"2805\" data-end=\"2808\"\u003ePharmaceutical laboratories\u003cbr data-start=\"2835\" data-end=\"2838\"\u003eChemical and petrochemical testing\u003cbr data-start=\"2872\" data-end=\"2875\"\u003ePlastic and polymer moisture analysis\u003cbr data-start=\"2912\" data-end=\"2915\"\u003ePaper and pulp industry\u003cbr data-start=\"2938\" data-end=\"2941\"\u003eTextile laboratories\u003cbr data-start=\"2961\" data-end=\"2964\"\u003eResearch and quality control laboratories\u003cbr data-start=\"3005\" data-end=\"3008\"\u003eRaw material inspection\u003cbr data-start=\"3031\" data-end=\"3034\"\u003eIndustrial production monitoring\u003c\/p\u003e","brand":"Wensar","offers":[{"title":"Default Title","offer_id":50014225989869,"sku":null,"price":0.0,"currency_code":"INR","in_stock":true}],"url":"https:\/\/www.biotronscientific.com\/products\/moisture-analyzer-lmb16-160g-capacity-1mg-readability-halogen-heating-graphic-display","provider":"BIOTRON","version":"1.0","type":"link"}