{"product_id":"microvolume-spectrophotometer-msod6-190-to-850-nm-biophotometer","title":"Microvolume Spectrophotometer MSOD6 (Biophotometer)","description":"\u003cp data-path-to-node=\"4\"\u003eThe MSOD6 is a high-performance Microvolume Spectrophotometer and Biophotometer designed for the precise quantification of nucleic acids, proteins, and cell cultures using microliter-range sample volumes. By requiring only 0.5 to 2 \u003cspan class=\"math-inline\" data-math=\"\\mu\" data-index-in-node=\"232\"\u003e$\\mu$\u003c\/span\u003eL of sample, this instrument allows researchers to analyze precious samples with high accuracy while eliminating the need for cuvettes or capillaries in most assays.\u003c\/p\u003e\n\u003cp data-path-to-node=\"5\"\u003eTechnically, the MSOD6 features a full-wavelength scanning range of 190–850nm and utilizes four optical paths to ensure linearity across varying concentrations. It integrates a Xenon flash lamp and UV-enhanced CMOS sensors for rapid measurements in under 6 seconds. The built-in Android operating system and 7-inch touch screen provide an intuitive interface for Nucleic Acid Testing (dsDNA range 2-27500ng\/\u003cspan class=\"math-inline\" data-math=\"\\mu\" data-index-in-node=\"407\"\u003e$\\mu$\u003c\/span\u003eL), Protein Analysis, OD600 measurement, and Kinetics. Additionally, the unit features built-in fluorescence detection for sensitive quantification of DNA and RNA using fluorescent dyes.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"7\"\u003eKey Features\u003c\/h3\u003e\n\u003cp data-path-to-node=\"8,0,0\"\u003eMicrovolume Spectrophotometer has full wavelength detection 190-850nm.\u003c\/p\u003e\n\u003cp data-path-to-node=\"8,1,0\"\u003e4 Optical path detection Technology Mode, Stability Repeatability, Linearity\u003c\/p\u003e\n\u003cp data-path-to-node=\"8,2,0\"\u003eOD600 measurement optical path detection system, Nucleic Acid Test, Protein Analysis, Colorimetric Method UV-Vis Detection, Kinetics\u003c\/p\u003e\n\u003cp data-path-to-node=\"8,3,0\"\u003eFluorescence quantitative reagent can detect pg concentration dsDNA\u003c\/p\u003e\n\u003cp data-path-to-node=\"8,4,0\"\u003eMicro Sample Volume can accurately detect nucleic acid, protein, and cell solutions using only 0.5 to 2 \u003cspan class=\"math-inline\" data-math=\"\\mu\" data-index-in-node=\"104\"\u003e$\\mu$\u003c\/span\u003eL of sample.\u003c\/p\u003e\n\u003cp data-path-to-node=\"8,5,0\"\u003eCuvette Mode for bacteria and other culture fluid concentration detection.\u003c\/p\u003e\n\u003cp data-path-to-node=\"8,6,0\"\u003eFluorescence detection for precise quantification of DNA, RNA, and protein concentrations using fluorescent dyes.\u003c\/p\u003e\n\u003cp data-path-to-node=\"8,7,0\"\u003eNucleic acid assays can be performed by directly spotting the sample onto the spiking plate eliminating the need for colorimetric cups or capillaries.\u003c\/p\u003e\n\u003cp data-path-to-node=\"8,8,0\"\u003eQuick and simple measurement steps.\u003c\/p\u003e\n\u003cp data-path-to-node=\"8,9,0\"\u003e \u003c\/p\u003e\n\u003ch3 data-path-to-node=\"10\"\u003eProduct Specification Table\u003c\/h3\u003e\n\u003ctable data-path-to-node=\"11\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetail\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"11,1,0,0\"\u003e\u003cb data-path-to-node=\"11,1,0,0\" data-index-in-node=\"0\"\u003eModel\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"11,1,1,0\"\u003eMSOD6\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"11,2,0,0\"\u003e\u003cb data-path-to-node=\"11,2,0,0\" data-index-in-node=\"0\"\u003eWavelength Range\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"11,2,1,0\"\u003e190-850nm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"11,3,0,0\"\u003e\u003cb data-path-to-node=\"11,3,0,0\" data-index-in-node=\"0\"\u003eSample Volume\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"11,3,1,0\"\u003e0.5-2 \u003cspan class=\"math-inline\" data-math=\"\\mu\" data-index-in-node=\"6\"\u003e$\\mu$\u003c\/span\u003eL\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"11,4,0,0\"\u003e\u003cb data-path-to-node=\"11,4,0,0\" data-index-in-node=\"0\"\u003eOptical Path (4)\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"11,4,1,0\"\u003e0.02mm, 0.05mm, 0.2mm, 1.0mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"11,5,0,0\"\u003e\u003cb data-path-to-node=\"11,5,0,0\" data-index-in-node=\"0\"\u003eNucleic Acid Testing Range\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"11,5,1,0\"\u003e2-27500ng\/\u003cspan class=\"math-inline\" data-math=\"\\mu\" data-index-in-node=\"10\"\u003e$\\mu$\u003c\/span\u003eL (dsDNA)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"11,6,0,0\"\u003e\u003cb data-path-to-node=\"11,6,0,0\" data-index-in-node=\"0\"\u003eLight Source\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"11,6,1,0\"\u003eXenon flash lamp\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"11,7,0,0\"\u003e\u003cb data-path-to-node=\"11,7,0,0\" data-index-in-node=\"0\"\u003eDetectors\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"11,7,1,0\"\u003eUV-enhanced CMOS Line Array Sensors\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"11,8,0,0\"\u003e\u003cb data-path-to-node=\"11,8,0,0\" data-index-in-node=\"0\"\u003eAbsorbance Accuracy\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"11,8,1,0\"\u003e0.002Abs (0.2mm Light Range)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"11,9,0,0\"\u003e\u003cb data-path-to-node=\"11,9,0,0\" data-index-in-node=\"0\"\u003eOD600 Absorbance Range\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"11,9,1,0\"\u003e0 ~ 6.000 Abs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"11,10,0,0\"\u003e\u003cb data-path-to-node=\"11,10,0,0\" data-index-in-node=\"0\"\u003eTesting Time\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"11,10,1,0\"\u003e\u0026lt; 6 Sec\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"11,11,0,0\"\u003e\u003cb data-path-to-node=\"11,11,0,0\" data-index-in-node=\"0\"\u003eFluorescence Sensitivity\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"11,11,1,0\"\u003edsDNA 0.5pg\/\u003cspan class=\"math-inline\" data-math=\"\\mu\" data-index-in-node=\"12\"\u003e$\\mu$\u003c\/span\u003eL\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"11,12,0,0\"\u003e\u003cb data-path-to-node=\"11,12,0,0\" data-index-in-node=\"0\"\u003eDisplay\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"11,12,1,0\"\u003e7\" Touch Screen\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"11,13,0,0\"\u003e\u003cb data-path-to-node=\"11,13,0,0\" data-index-in-node=\"0\"\u003eOperating System\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"11,13,1,0\"\u003eBuilt-In Android OS\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"11,14,0,0\"\u003e\u003cb data-path-to-node=\"11,14,0,0\" data-index-in-node=\"0\"\u003ePrinting\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"11,14,1,0\"\u003eIn-built Thermal Printer\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"11,15,0,0\"\u003e\u003cb data-path-to-node=\"11,15,0,0\" data-index-in-node=\"0\"\u003ePower Supply\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"11,15,1,0\"\u003eAdaptor, AC 220V \/ 50Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"11,16,0,0\"\u003e\u003cb data-path-to-node=\"11,16,0,0\" data-index-in-node=\"0\"\u003eGross Weight\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"11,16,1,0\"\u003e10kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Labman","offers":[{"title":"Default Title","offer_id":48952582602989,"sku":null,"price":341000.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5672\/6765\/files\/MSOD6.jpg?v=1776263432","url":"https:\/\/www.biotronscientific.com\/products\/microvolume-spectrophotometer-msod6-190-to-850-nm-biophotometer","provider":"BIOTRON","version":"1.0","type":"link"}