{"product_id":"laboratory-water-purification-system-lwps10lt-10-l-h-production-7-touch-screen-ro-ultra-pure-water","title":"Laboratory Water Purification System – LWPS10LT (10 L\/H Production | 7\" Touch Screen | RO + Ultra Pure Water)","description":"\u003cp data-start=\"536\" data-end=\"876\"\u003eLWPS10LT Laboratory Water Purification System is designed to provide reliable production of reverse osmosis and ultrapure water for demanding laboratory applications. Equipped with a 7-inch touch screen and a microcomputer-based control system, the unit offers intelligent operation, comprehensive monitoring and advanced safety protection.\u003c\/p\u003e\n\u003cp data-start=\"878\" data-end=\"1137\"\u003eThe system continuously monitors conductivity, resistivity, flow rate, pressure and tank level to ensure stable water quality. Simultaneous online monitoring of source water, RO water and ultrapure water enables real-time tracking of water quality parameters.\u003c\/p\u003e\n\u003cp data-start=\"1139\" data-end=\"1425\"\u003eAn automatic membrane anti-scaling flushing program helps prolong membrane life, while integrated pressure protection prevents bacterial recontamination. Comprehensive alarm functions provide alerts for low pressure, raw water quality, purified water quality and consumable replacement.\u003c\/p\u003e\n\u003cp data-start=\"1427\" data-end=\"1667\"\u003eWith high ion removal efficiency and excellent organic retention performance, LWPS10LT produces ultrapure water suitable for analytical chemistry, microbiology, molecular biology, pharmaceutical research and general laboratory applications.\u003c\/p\u003e\n\u003ch3 data-start=\"1669\" data-end=\"1684\"\u003eKey Features\u003c\/h3\u003e\n\u003cp data-start=\"1686\" data-end=\"2344\"\u003e7-inch touch screen display\u003cbr\u003eFully automatic operation\u003cbr\u003e32-bit microcomputer control system\u003cbr\u003eReal-time monitoring of conductivity and resistivity\u003cbr\u003eMonitoring of flow rate, pressure and tank level\u003cbr\u003eSimultaneous monitoring of source water, RO water and ultrapure water\u003cbr\u003eLow-pressure protection system\u003cbr\u003eAutomatic water production stop when tank is full\u003cbr\u003eComprehensive alarm system\u003cbr\u003eRO membrane anti-scaling flushing program\u003cbr\u003eIntegrated pressure system to prevent bacterial recontamination\u003cbr\u003eTimed water withdrawal function\u003cbr\u003eQuantitative water dispensing function\u003cbr\u003eDate and time display\u003cbr\u003eUSB communication interface\u003cbr\u003ePassword protection and alarm functions\u003cbr\u003eInternal data storage\u003c\/p\u003e\n\u003ch3 data-start=\"2346\" data-end=\"2373\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"2375\" data-end=\"3586\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"2375\" data-end=\"2399\"\u003e\n\u003ctr data-start=\"2375\" data-end=\"2399\"\u003e\n\u003cth data-start=\"2375\" data-end=\"2387\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth data-start=\"2387\" data-end=\"2399\" data-col-size=\"md\" class=\"last:pe-10\"\u003eLWPS10LT\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"2427\" data-end=\"3586\"\u003e\n\u003ctr data-start=\"2427\" data-end=\"2465\"\u003e\n\u003ctd data-start=\"2427\" data-end=\"2455\" data-col-size=\"sm\"\u003eWater Production Capacity\u003c\/td\u003e\n\u003ctd data-start=\"2455\" data-end=\"2465\" data-col-size=\"md\"\u003e10 L\/H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2466\" data-end=\"2541\"\u003e\n\u003ctd data-start=\"2466\" data-end=\"2487\" data-col-size=\"sm\"\u003eInlet Water Source\u003c\/td\u003e\n\u003ctd data-start=\"2487\" data-end=\"2541\" data-col-size=\"md\"\u003eCity tap water, pressure 0.1–0.5 MPa, TDS \u0026lt;300 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2542\" data-end=\"2608\"\u003e\n\u003ctd data-start=\"2542\" data-end=\"2571\" data-col-size=\"sm\"\u003eInstantaneous Water Intake\u003c\/td\u003e\n\u003ctd data-start=\"2571\" data-end=\"2608\" data-col-size=\"md\"\u003e1.5–2.0 L\/min (when tank is full)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2609\" data-end=\"2638\"\u003e\n\u003ctd data-start=\"2609\" data-end=\"2619\" data-col-size=\"sm\"\u003eDisplay\u003c\/td\u003e\n\u003ctd data-start=\"2619\" data-end=\"2638\" data-col-size=\"md\"\u003e7\" Touch Screen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2639\" data-end=\"2680\"\u003e\n\u003ctd data-start=\"2639\" data-end=\"2677\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2641\" data-end=\"2676\"\u003eUltra Pure Water Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2677\" data-end=\"2680\" data-col-size=\"md\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2681\" data-end=\"2718\"\u003e\n\u003ctd data-start=\"2681\" data-end=\"2695\" data-col-size=\"sm\"\u003eResistivity\u003c\/td\u003e\n\u003ctd data-start=\"2695\" data-end=\"2718\" data-col-size=\"md\"\u003e18.25 MΩ·cm at 25°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2719\" data-end=\"2749\"\u003e\n\u003ctd data-start=\"2719\" data-end=\"2737\" data-col-size=\"sm\"\u003eHeavy Metal Ion\u003c\/td\u003e\n\u003ctd data-start=\"2737\" data-end=\"2749\" data-col-size=\"md\"\u003e\u0026lt;0.1 ppb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2750\" data-end=\"2790\"\u003e\n\u003ctd data-start=\"2750\" data-end=\"2779\" data-col-size=\"sm\"\u003eTotal Organic Carbon (TOC)\u003c\/td\u003e\n\u003ctd data-start=\"2779\" data-end=\"2790\" data-col-size=\"md\"\u003e\u0026lt;10 ppb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2791\" data-end=\"2822\"\u003e\n\u003ctd data-start=\"2791\" data-end=\"2806\" data-col-size=\"sm\"\u003eGerm Content\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2806\" data-end=\"2822\"\u003e\u0026lt;0.01 CFU\/ml\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2823\" data-end=\"2862\"\u003e\n\u003ctd data-start=\"2823\" data-end=\"2844\" data-col-size=\"sm\"\u003eParticulate Matter\u003c\/td\u003e\n\u003ctd data-start=\"2844\" data-end=\"2862\" data-col-size=\"md\"\u003e\u0026gt;0.2 μm, \u0026lt;1\/ml\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2863\" data-end=\"2896\"\u003e\n\u003ctd data-start=\"2863\" data-end=\"2889\" data-col-size=\"sm\"\u003eHeat Source (Endotoxin)\u003c\/td\u003e\n\u003ctd data-start=\"2889\" data-end=\"2896\" data-col-size=\"md\"\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2897\" data-end=\"2929\"\u003e\n\u003ctd data-start=\"2897\" data-end=\"2922\" data-col-size=\"sm\"\u003eRibonucleases (RNases)\u003c\/td\u003e\n\u003ctd data-start=\"2922\" data-end=\"2929\" data-col-size=\"md\"\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2930\" data-end=\"2967\"\u003e\n\u003ctd data-start=\"2930\" data-end=\"2960\" data-col-size=\"sm\"\u003eDeoxyribonucleases (DNases)\u003c\/td\u003e\n\u003ctd data-start=\"2960\" data-end=\"2967\" data-col-size=\"md\"\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2968\" data-end=\"3001\"\u003e\n\u003ctd data-start=\"2968\" data-end=\"2998\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2970\" data-end=\"2997\"\u003eRO Water Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2998\" data-end=\"3001\" data-col-size=\"md\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3002\" data-end=\"3037\"\u003e\n\u003ctd data-start=\"3002\" data-end=\"3017\" data-col-size=\"sm\"\u003eConductivity\u003c\/td\u003e\n\u003ctd data-start=\"3017\" data-end=\"3037\" data-col-size=\"md\"\u003e≤1 μS\/cm at 25°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3038\" data-end=\"3092\"\u003e\n\u003ctd data-start=\"3038\" data-end=\"3060\" data-col-size=\"sm\"\u003eIon Trap Efficiency\u003c\/td\u003e\n\u003ctd data-start=\"3060\" data-end=\"3092\" data-col-size=\"md\"\u003e\u0026gt;98% (using new RO membrane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3093\" data-end=\"3144\"\u003e\n\u003ctd data-start=\"3093\" data-end=\"3118\" data-col-size=\"sm\"\u003eOrganic Retention Rate\u003c\/td\u003e\n\u003ctd data-start=\"3118\" data-end=\"3144\" data-col-size=\"md\"\u003e\u0026gt;99% (MW \u0026gt;200 Daltons)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3145\" data-end=\"3188\"\u003e\n\u003ctd data-start=\"3145\" data-end=\"3180\" data-col-size=\"sm\"\u003eParticle and Bacterial Retention\u003c\/td\u003e\n\u003ctd data-start=\"3180\" data-end=\"3188\" data-col-size=\"md\"\u003e\u0026gt;99%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3189\" data-end=\"3228\"\u003e\n\u003ctd data-start=\"3189\" data-end=\"3221\" data-col-size=\"sm\"\u003eAlarm and Password Protection\u003c\/td\u003e\n\u003ctd data-start=\"3221\" data-end=\"3228\" data-col-size=\"md\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3229\" data-end=\"3257\"\u003e\n\u003ctd data-start=\"3229\" data-end=\"3244\" data-col-size=\"sm\"\u003eData Storage\u003c\/td\u003e\n\u003ctd data-start=\"3244\" data-end=\"3257\" data-col-size=\"md\"\u003eAvailable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3258\" data-end=\"3291\"\u003e\n\u003ctd data-start=\"3258\" data-end=\"3280\" data-col-size=\"sm\"\u003eWorking Temperature\u003c\/td\u003e\n\u003ctd data-start=\"3280\" data-end=\"3291\" data-col-size=\"md\"\u003e10–40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3292\" data-end=\"3330\"\u003e\n\u003ctd data-start=\"3292\" data-end=\"3313\" data-col-size=\"sm\"\u003eCommunication Port\u003c\/td\u003e\n\u003ctd data-start=\"3313\" data-end=\"3330\" data-col-size=\"md\"\u003eUSB Interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3331\" data-end=\"3363\"\u003e\n\u003ctd data-start=\"3331\" data-end=\"3351\" data-col-size=\"sm\"\u003ePower Consumption\u003c\/td\u003e\n\u003ctd data-start=\"3351\" data-end=\"3363\" data-col-size=\"md\"\u003e45–100 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3364\" data-end=\"3400\"\u003e\n\u003ctd data-start=\"3364\" data-end=\"3379\" data-col-size=\"sm\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd data-start=\"3379\" data-end=\"3400\" data-col-size=\"md\"\u003eAC 220V, 50–60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3401\" data-end=\"3452\"\u003e\n\u003ctd data-start=\"3401\" data-end=\"3430\" data-col-size=\"sm\"\u003eMachine Dimensions (L×W×H)\u003c\/td\u003e\n\u003ctd data-start=\"3430\" data-end=\"3452\" data-col-size=\"md\"\u003e470 × 570 × 615 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3453\" data-end=\"3504\"\u003e\n\u003ctd data-start=\"3453\" data-end=\"3482\" data-col-size=\"sm\"\u003ePacking Dimensions (L×W×H)\u003c\/td\u003e\n\u003ctd data-start=\"3482\" data-end=\"3504\" data-col-size=\"md\"\u003e485 × 660 × 730 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3505\" data-end=\"3527\"\u003e\n\u003ctd data-start=\"3505\" data-end=\"3518\" data-col-size=\"sm\"\u003eNet Weight\u003c\/td\u003e\n\u003ctd data-start=\"3518\" data-end=\"3527\" data-col-size=\"md\"\u003e23 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3528\" data-end=\"3552\"\u003e\n\u003ctd data-start=\"3528\" data-end=\"3543\" data-col-size=\"sm\"\u003eGross Weight\u003c\/td\u003e\n\u003ctd data-start=\"3543\" data-end=\"3552\" data-col-size=\"md\"\u003e36 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3553\" data-end=\"3586\"\u003e\n\u003ctd data-start=\"3553\" data-end=\"3568\" data-col-size=\"sm\"\u003ePacking Type\u003c\/td\u003e\n\u003ctd data-start=\"3568\" data-end=\"3586\" data-col-size=\"md\"\u003eWooden Packing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 data-start=\"3731\" data-end=\"3746\"\u003eApplications\u003c\/h3\u003e\n\u003cp data-start=\"3748\" data-end=\"4152\"\u003eAnalytical laboratories\u003cbr data-start=\"3771\" data-end=\"3774\"\u003eHPLC and chromatography applications\u003cbr data-start=\"3810\" data-end=\"3813\"\u003eAtomic absorption spectroscopy laboratories\u003cbr data-start=\"3856\" data-end=\"3859\"\u003eICP and trace element analysis\u003cbr data-start=\"3889\" data-end=\"3892\"\u003ePharmaceutical laboratories\u003cbr data-start=\"3919\" data-end=\"3922\"\u003eMicrobiology laboratories\u003cbr data-start=\"3947\" data-end=\"3950\"\u003eMolecular biology and biotechnology research\u003cbr data-start=\"3994\" data-end=\"3997\"\u003eCell culture applications\u003cbr data-start=\"4022\" data-end=\"4025\"\u003eClinical laboratories\u003cbr data-start=\"4046\" data-end=\"4049\"\u003eEnvironmental testing laboratories\u003cbr data-start=\"4083\" data-end=\"4086\"\u003eEducational and research institutes\u003cbr data-start=\"4121\" data-end=\"4124\"\u003eQuality control laboratories\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Labman","offers":[{"title":"Default Title","offer_id":50104427184365,"sku":null,"price":160000.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5672\/6765\/files\/LWPS10LT.jpg?v=1781453072","url":"https:\/\/www.biotronscientific.com\/products\/laboratory-water-purification-system-lwps10lt-10-l-h-production-7-touch-screen-ro-ultra-pure-water","provider":"BIOTRON","version":"1.0","type":"link"}