{"product_id":"hydrogen-generator-ggh301-ggh302-99-999-purity-300-ml-min","title":"Hydrogen Generator GGH301 \u0026 GGH302 (99.999% Purity, 300 ml\/min)","description":"\u003cp data-start=\"279\" data-end=\"604\"\u003eHydrogen Generator GGH301 and GGH302 are designed to provide continuous high-purity hydrogen gas supply for analytical laboratories and scientific instrumentation. The systems deliver stable hydrogen generation with reliable pressure control, making them suitable for gas chromatography and other laboratory gas applications.\u003c\/p\u003e\n\u003cp data-start=\"606\" data-end=\"874\"\u003eThe generator series provides hydrogen purity up to 99.999% with stable flow performance and efficient electrolysis technology. Both models feature automatic pressure display, digital gas flow monitoring, and stable output pressure for dependable analytical operation.\u003c\/p\u003e\n\u003cp data-start=\"876\" data-end=\"1090\"\u003eGGH301 operates using an alkaline electrolyte system with a 1.2 L fluid tank capacity, while GGH302 uses a pure water hydrogen generation system with a larger 2 L tank capacity for cleaner and simplified operation.\u003c\/p\u003e\n\u003cp data-start=\"1092\" data-end=\"1373\"\u003eThe compact bench-top design allows convenient installation in laboratory environments, while the LED display provides clear monitoring of gas flow conditions. High electrolysis efficiency ensures stable hydrogen generation without flow or purity degradation during continuous use.\u003c\/p\u003e\n\u003cp data-start=\"1375\" data-end=\"1608\"\u003eThese hydrogen generators are widely used in gas chromatography systems, analytical laboratories, environmental testing facilities, petrochemical laboratories, and research institutions requiring reliable high-purity hydrogen supply.\u003c\/p\u003e\n\u003ch3 data-start=\"1610\" data-end=\"1625\"\u003eKey Features\u003c\/h3\u003e\n\u003cp data-start=\"1627\" data-end=\"2075\"\u003eHydrogen purity up to 99.999%\u003cbr data-start=\"1656\" data-end=\"1659\"\u003eStable output pressure for analytical systems\u003cbr data-start=\"1704\" data-end=\"1707\"\u003eDigital gas flow display\u003cbr data-start=\"1731\" data-end=\"1734\"\u003eAutomatic pressure monitoring\u003cbr data-start=\"1763\" data-end=\"1766\"\u003eHigh electrolysis efficiency\u003cbr data-start=\"1794\" data-end=\"1797\"\u003eContinuous hydrogen generation system\u003cbr data-start=\"1834\" data-end=\"1837\"\u003eCompact laboratory bench-top design\u003cbr data-start=\"1872\" data-end=\"1875\"\u003eStable flow rate without purity decay\u003cbr data-start=\"1912\" data-end=\"1915\"\u003eEasy operation and maintenance\u003cbr data-start=\"1945\" data-end=\"1948\"\u003eSuitable for gas chromatography applications\u003cbr data-start=\"1992\" data-end=\"1995\"\u003eLED display for operational monitoring\u003cbr data-start=\"2033\" data-end=\"2036\"\u003eReliable laboratory hydrogen gas source\u003c\/p\u003e\n\u003ch3 data-start=\"2077\" data-end=\"2104\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"2106\" data-end=\"2659\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"2106\" data-end=\"2137\"\u003e\n\u003ctr data-start=\"2106\" data-end=\"2137\"\u003e\n\u003cth data-start=\"2106\" data-end=\"2118\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth data-start=\"2118\" data-end=\"2127\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eGGH301\u003c\/th\u003e\n\u003cth data-start=\"2127\" data-end=\"2137\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eGGH302\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"2158\" data-end=\"2659\"\u003e\n\u003ctr data-start=\"2158\" data-end=\"2190\"\u003e\n\u003ctd data-start=\"2158\" data-end=\"2165\" data-col-size=\"sm\"\u003eType\u003c\/td\u003e\n\u003ctd data-start=\"2165\" data-end=\"2176\" data-col-size=\"sm\"\u003eAlkaline\u003c\/td\u003e\n\u003ctd data-start=\"2176\" data-end=\"2190\" data-col-size=\"sm\"\u003ePure Water\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2191\" data-end=\"2228\"\u003e\n\u003ctd data-start=\"2191\" data-end=\"2213\" data-col-size=\"sm\"\u003eFluid Tank Capacity\u003c\/td\u003e\n\u003ctd data-start=\"2213\" data-end=\"2221\" data-col-size=\"sm\"\u003e1.2 L\u003c\/td\u003e\n\u003ctd data-start=\"2221\" data-end=\"2228\" data-col-size=\"sm\"\u003e2 L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2229\" data-end=\"2271\"\u003e\n\u003ctd data-start=\"2229\" data-end=\"2244\" data-col-size=\"sm\"\u003eMaximum Flow\u003c\/td\u003e\n\u003ctd data-start=\"2244\" data-end=\"2257\" data-col-size=\"sm\"\u003e300 ml\/min\u003c\/td\u003e\n\u003ctd data-start=\"2257\" data-end=\"2271\" data-col-size=\"sm\"\u003e300 ml\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2272\" data-end=\"2306\"\u003e\n\u003ctd data-start=\"2272\" data-end=\"2285\" data-col-size=\"sm\"\u003eGas Purity\u003c\/td\u003e\n\u003ctd data-start=\"2285\" data-end=\"2295\" data-col-size=\"sm\"\u003e99.999%\u003c\/td\u003e\n\u003ctd data-start=\"2295\" data-end=\"2306\" data-col-size=\"sm\"\u003e99.999%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2307\" data-end=\"2350\"\u003e\n\u003ctd data-start=\"2307\" data-end=\"2329\" data-col-size=\"sm\"\u003eOutput Gas Pressure\u003c\/td\u003e\n\u003ctd data-start=\"2329\" data-end=\"2339\" data-col-size=\"sm\"\u003e0.3 MPa\u003c\/td\u003e\n\u003ctd data-start=\"2339\" data-end=\"2350\" data-col-size=\"sm\"\u003e0.3 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2351\" data-end=\"2400\"\u003e\n\u003ctd data-start=\"2351\" data-end=\"2375\" data-col-size=\"sm\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd data-start=\"2375\" data-end=\"2387\" data-col-size=\"sm\"\u003e10°C–40°C\u003c\/td\u003e\n\u003ctd data-start=\"2387\" data-end=\"2400\" data-col-size=\"sm\"\u003e10°C–40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2401\" data-end=\"2452\"\u003e\n\u003ctd data-start=\"2401\" data-end=\"2423\" data-col-size=\"sm\"\u003eOutput Flow Display\u003c\/td\u003e\n\u003ctd data-start=\"2423\" data-end=\"2437\" data-col-size=\"sm\"\u003eLED Display\u003c\/td\u003e\n\u003ctd data-start=\"2437\" data-end=\"2452\" data-col-size=\"sm\"\u003eLED Display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2453\" data-end=\"2486\"\u003e\n\u003ctd data-start=\"2453\" data-end=\"2469\" data-col-size=\"sm\"\u003ePower Wattage\u003c\/td\u003e\n\u003ctd data-start=\"2469\" data-end=\"2477\" data-col-size=\"sm\"\u003e150 W\u003c\/td\u003e\n\u003ctd data-start=\"2477\" data-end=\"2486\" data-col-size=\"sm\"\u003e150 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2487\" data-end=\"2516\"\u003e\n\u003ctd data-start=\"2487\" data-end=\"2495\" data-col-size=\"sm\"\u003ePhase\u003c\/td\u003e\n\u003ctd data-start=\"2495\" data-end=\"2505\" data-col-size=\"sm\"\u003e1 Phase\u003c\/td\u003e\n\u003ctd data-start=\"2505\" data-end=\"2516\" data-col-size=\"sm\"\u003e1 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2517\" data-end=\"2567\"\u003e\n\u003ctd data-start=\"2517\" data-end=\"2532\" data-col-size=\"sm\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd data-start=\"2532\" data-end=\"2549\" data-col-size=\"sm\"\u003eAC 220V \/ 50Hz\u003c\/td\u003e\n\u003ctd data-start=\"2549\" data-end=\"2567\" data-col-size=\"sm\"\u003eAC 220V \/ 50Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2568\" data-end=\"2632\"\u003e\n\u003ctd data-start=\"2568\" data-end=\"2589\" data-col-size=\"sm\"\u003eDimensions (L×W×H)\u003c\/td\u003e\n\u003ctd data-start=\"2589\" data-end=\"2610\" data-col-size=\"sm\"\u003e450 × 340 × 500 mm\u003c\/td\u003e\n\u003ctd data-start=\"2610\" data-end=\"2632\" data-col-size=\"sm\"\u003e450 × 340 × 500 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2633\" data-end=\"2659\"\u003e\n\u003ctd data-start=\"2633\" data-end=\"2642\" data-col-size=\"sm\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-start=\"2642\" data-end=\"2650\" data-col-size=\"sm\"\u003e17 kg\u003c\/td\u003e\n\u003ctd data-start=\"2650\" data-end=\"2659\" data-col-size=\"sm\"\u003e18 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 data-start=\"2661\" data-end=\"2676\"\u003eApplications\u003c\/h3\u003e\n\u003cp data-start=\"2678\" data-end=\"2918\"\u003eGas chromatography systems\u003cbr data-start=\"2704\" data-end=\"2707\"\u003eAnalytical laboratory instruments\u003cbr data-start=\"2740\" data-end=\"2743\"\u003ePetrochemical laboratories\u003cbr data-start=\"2769\" data-end=\"2772\"\u003eEnvironmental testing laboratories\u003cbr data-start=\"2806\" data-end=\"2809\"\u003eResearch and development facilities\u003cbr data-start=\"2844\" data-end=\"2847\"\u003eChemical analysis applications\u003cbr data-start=\"2877\" data-end=\"2880\"\u003eContinuous hydrogen gas supply systems\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Labman","offers":[{"title":"GGH301","offer_id":49973087568109,"sku":null,"price":50000.0,"currency_code":"INR","in_stock":true},{"title":"GGH302","offer_id":49973087600877,"sku":null,"price":95000.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5672\/6765\/files\/GGH301.jpg?v=1778963702","url":"https:\/\/www.biotronscientific.com\/products\/hydrogen-generator-ggh301-ggh302-99-999-purity-300-ml-min","provider":"BIOTRON","version":"1.0","type":"link"}