{"product_id":"high-speed-automatic-polarimeter-adp95cfr-single-wavelength-589-nm-0-004-accuracy-peltier-control","title":"High Speed Automatic Polarimeter ADP95CFR (Single Wavelength 589 nm, ±0.004° Accuracy, Peltier Control)","description":"\u003cp data-start=\"320\" data-end=\"695\"\u003eHigh Speed Automatic Polarimeter ADP95CFR is a precision analytical instrument designed for accurate measurement of optical rotation, specific rotation, sugar concentration, and related parameters in optically active substances. Operating at a fixed wavelength of 589 nm, it delivers highly stable and repeatable results across routine and advanced laboratory applications.\u003c\/p\u003e\n\u003cp data-start=\"697\" data-end=\"959\"\u003eThe instrument incorporates an advanced control system with Android-based interface, enabling intuitive operation through a large touchscreen display. Built-in Peltier temperature control ensures consistent sample conditions, enhancing measurement reliability.\u003c\/p\u003e\n\u003cp data-start=\"961\" data-end=\"1193\"\u003eWith compliance to GMP, GLP, and 21 CFR Part 11 standards, along with large internal storage and automated calibration, the system is ideal for regulated environments such as pharmaceutical quality control and research laboratories.\u003c\/p\u003e\n\u003ch3 data-start=\"1195\" data-end=\"1212\"\u003eKey Features\u003c\/h3\u003e\n\u003cp data-start=\"1213\" data-end=\"1815\"\u003eSingle wavelength operation at 589 nm for stable measurements\u003cbr data-start=\"1274\" data-end=\"1277\"\u003eHigh accuracy up to ±0.004° with excellent repeatability\u003cbr data-start=\"1333\" data-end=\"1336\"\u003eAdvanced Peltier temperature control for precise thermal stability\u003cbr data-start=\"1402\" data-end=\"1405\"\u003eAndroid-based operating system with intuitive interface\u003cbr data-start=\"1460\" data-end=\"1463\"\u003e10.1-inch color touchscreen display\u003cbr data-start=\"1498\" data-end=\"1501\"\u003eMultiple measurement modes including optical rotation and sugar analysis\u003cbr data-start=\"1573\" data-end=\"1576\"\u003eMultipoint automatic calibration for enhanced accuracy\u003cbr data-start=\"1630\" data-end=\"1633\"\u003eLarge internal storage up to 128GB\u003cbr data-start=\"1667\" data-end=\"1670\"\u003eFast measurement with high response speed\u003cbr data-start=\"1711\" data-end=\"1714\"\u003e21 CFR Part 11 compliance for secure data management\u003cbr data-start=\"1766\" data-end=\"1769\"\u003eUSB and RS232 connectivity for data transfer\u003c\/p\u003e\n\u003ch3 data-start=\"1817\" data-end=\"1846\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"1848\" data-end=\"2511\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"1848\" data-end=\"1877\"\u003e\n\u003ctr data-start=\"1848\" data-end=\"1877\"\u003e\n\u003cth data-start=\"1848\" data-end=\"1860\" data-col-size=\"sm\" class=\"\"\u003eParameter\u003c\/th\u003e\n\u003cth data-start=\"1860\" data-end=\"1877\" data-col-size=\"sm\" class=\"\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"1888\" data-end=\"2511\"\u003e\n\u003ctr data-start=\"1888\" data-end=\"1947\"\u003e\n\u003ctd data-start=\"1888\" data-end=\"1908\" data-col-size=\"sm\"\u003eMeasurement Range\u003c\/td\u003e\n\u003ctd data-start=\"1908\" data-end=\"1947\" data-col-size=\"sm\"\u003e±90° Optical Rotation, ±259°Z Sugar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1948\" data-end=\"1976\"\u003e\n\u003ctd data-start=\"1948\" data-end=\"1966\" data-col-size=\"sm\"\u003eMinimum Reading\u003c\/td\u003e\n\u003ctd data-start=\"1966\" data-end=\"1976\" data-col-size=\"sm\"\u003e0.001°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1977\" data-end=\"1999\"\u003e\n\u003ctd data-start=\"1977\" data-end=\"1988\" data-col-size=\"sm\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd data-start=\"1988\" data-end=\"1999\" data-col-size=\"sm\"\u003e±0.004°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2000\" data-end=\"2027\"\u003e\n\u003ctd data-start=\"2000\" data-end=\"2016\" data-col-size=\"sm\"\u003eRepeatability\u003c\/td\u003e\n\u003ctd data-start=\"2016\" data-end=\"2027\" data-col-size=\"sm\"\u003e±0.002°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2028\" data-end=\"2051\"\u003e\n\u003ctd data-start=\"2028\" data-end=\"2041\" data-col-size=\"sm\"\u003eWavelength\u003c\/td\u003e\n\u003ctd data-start=\"2041\" data-end=\"2051\" data-col-size=\"sm\"\u003e589 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2052\" data-end=\"2074\"\u003e\n\u003ctd data-start=\"2052\" data-end=\"2067\" data-col-size=\"sm\"\u003eLight Source\u003c\/td\u003e\n\u003ctd data-start=\"2067\" data-end=\"2074\" data-col-size=\"sm\"\u003eLED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2075\" data-end=\"2122\"\u003e\n\u003ctd data-start=\"2075\" data-end=\"2095\" data-col-size=\"sm\"\u003eMeasurement Speed\u003c\/td\u003e\n\u003ctd data-start=\"2095\" data-end=\"2122\" data-col-size=\"sm\"\u003e6 measurements \/ 26 sec\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2123\" data-end=\"2150\"\u003e\n\u003ctd data-start=\"2123\" data-end=\"2140\" data-col-size=\"sm\"\u003eResponse Speed\u003c\/td\u003e\n\u003ctd data-start=\"2140\" data-end=\"2150\" data-col-size=\"sm\"\u003e8°\/sec\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2151\" data-end=\"2195\"\u003e\n\u003ctd data-start=\"2151\" data-end=\"2173\" data-col-size=\"sm\"\u003eTemperature Control\u003c\/td\u003e\n\u003ctd data-start=\"2173\" data-end=\"2195\" data-col-size=\"sm\"\u003ePeltier (In-built)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2196\" data-end=\"2231\"\u003e\n\u003ctd data-start=\"2196\" data-end=\"2216\" data-col-size=\"sm\"\u003eTemperature Range\u003c\/td\u003e\n\u003ctd data-start=\"2216\" data-end=\"2231\" data-col-size=\"sm\"\u003e10°C – 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2232\" data-end=\"2265\"\u003e\n\u003ctd data-start=\"2232\" data-end=\"2255\" data-col-size=\"sm\"\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"2255\" data-end=\"2265\" data-col-size=\"sm\"\u003e±0.2°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2266\" data-end=\"2303\"\u003e\n\u003ctd data-start=\"2266\" data-end=\"2276\" data-col-size=\"sm\"\u003eDisplay\u003c\/td\u003e\n\u003ctd data-start=\"2276\" data-end=\"2303\" data-col-size=\"sm\"\u003e10.1\" Color Touchscreen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2304\" data-end=\"2322\"\u003e\n\u003ctd data-start=\"2304\" data-end=\"2313\" data-col-size=\"sm\"\u003eMemory\u003c\/td\u003e\n\u003ctd data-start=\"2313\" data-end=\"2322\" data-col-size=\"sm\"\u003e128GB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2323\" data-end=\"2346\"\u003e\n\u003ctd data-start=\"2323\" data-end=\"2334\" data-col-size=\"sm\"\u003eSoftware\u003c\/td\u003e\n\u003ctd data-start=\"2334\" data-end=\"2346\" data-col-size=\"sm\"\u003eIn-built\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2347\" data-end=\"2390\"\u003e\n\u003ctd data-start=\"2347\" data-end=\"2360\" data-col-size=\"sm\"\u003eCompliance\u003c\/td\u003e\n\u003ctd data-start=\"2360\" data-end=\"2390\" data-col-size=\"sm\"\u003eGMP \/ GLP \/ 21 CFR Part 11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2391\" data-end=\"2417\"\u003e\n\u003ctd data-start=\"2391\" data-end=\"2403\" data-col-size=\"sm\"\u003eInterface\u003c\/td\u003e\n\u003ctd data-start=\"2403\" data-end=\"2417\" data-col-size=\"sm\"\u003eUSB, RS232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2418\" data-end=\"2456\"\u003e\n\u003ctd data-start=\"2418\" data-end=\"2437\" data-col-size=\"sm\"\u003eTest Tube Length\u003c\/td\u003e\n\u003ctd data-start=\"2437\" data-end=\"2456\" data-col-size=\"sm\"\u003e100 mm \u0026amp; 200 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2457\" data-end=\"2492\"\u003e\n\u003ctd data-start=\"2457\" data-end=\"2470\" data-col-size=\"sm\"\u003eDimensions\u003c\/td\u003e\n\u003ctd data-start=\"2470\" data-end=\"2492\" data-col-size=\"sm\"\u003e870 × 520 × 475 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2493\" data-end=\"2511\"\u003e\n\u003ctd data-start=\"2493\" data-end=\"2502\" data-col-size=\"sm\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-start=\"2502\" data-end=\"2511\" data-col-size=\"sm\"\u003e34 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 data-start=\"2513\" data-end=\"2530\"\u003eApplications\u003c\/h3\u003e\n\u003cp data-start=\"2531\" data-end=\"2738\"\u003ePharmaceutical analysis and quality control\u003cbr data-start=\"2574\" data-end=\"2577\"\u003eSugar and food industry testing\u003cbr data-start=\"2608\" data-end=\"2611\"\u003eChemical and petrochemical laboratories\u003cbr data-start=\"2650\" data-end=\"2653\"\u003eAcademic and research institutions\u003cbr data-start=\"2687\" data-end=\"2690\"\u003eOptical activity and concentration measurement\u003c\/p\u003e","brand":"Labman","offers":[{"title":"Default Title","offer_id":49889628586221,"sku":null,"price":490000.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5672\/6765\/files\/ADP95CFR.webp?v=1778791234","url":"https:\/\/www.biotronscientific.com\/products\/high-speed-automatic-polarimeter-adp95cfr-single-wavelength-589-nm-0-004-accuracy-peltier-control","provider":"BIOTRON","version":"1.0","type":"link"}