{"product_id":"high-speed-automatic-polarimeter-adp100cfr-dual-wavelength-546-589-nm-0-004-accuracy","title":"High Speed Automatic Polarimeter ADP100CFR (Dual Wavelength 546\/589 nm, ±0.004° Accuracy)","description":"\u003cp data-start=\"314\" data-end=\"673\"\u003eHigh Speed Automatic Polarimeter ADP100CFR is an advanced analytical instrument designed for precise measurement of optical rotation, specific rotation, sugar content, and concentration in optically active substances. Equipped with dual wavelength capability (546 nm and 589 nm), it ensures high accuracy and flexibility across a wide range of applications.\u003c\/p\u003e\n\u003cp data-start=\"675\" data-end=\"1012\"\u003eThe system integrates Peltier-based temperature control for stable and reproducible measurements, making it ideal for pharmaceutical, chemical, and food industries. With built-in software, Windows-based operation, and compliance with GMP, GLP, and 21 CFR Part 11 standards, it supports secure data handling and regulatory requirements.\u003c\/p\u003e\n\u003cp data-start=\"1014\" data-end=\"1198\"\u003eIts high-speed measurement capability, intuitive touchscreen interface, and large internal storage make it suitable for both routine quality control and advanced research laboratories.\u003c\/p\u003e\n\u003ch3 data-start=\"1200\" data-end=\"1217\"\u003eKey Features\u003c\/h3\u003e\n\u003cp data-start=\"1218\" data-end=\"1862\"\u003eDual wavelength operation (546 nm \u0026amp; 589 nm) for versatile analysis\u003cbr data-start=\"1284\" data-end=\"1287\"\u003eHigh accuracy up to ±0.004° with excellent repeatability\u003cbr data-start=\"1343\" data-end=\"1346\"\u003ePeltier temperature control for stable measurement conditions\u003cbr data-start=\"1407\" data-end=\"1410\"\u003eMultiple measurement modes: optical rotation, specific rotation, sugar, concentration\u003cbr data-start=\"1495\" data-end=\"1498\"\u003e21 CFR Part 11 compliance for secure electronic records\u003cbr data-start=\"1553\" data-end=\"1556\"\u003eBuilt-in software with no need for external PC\u003cbr data-start=\"1602\" data-end=\"1605\"\u003e8-inch color touchscreen interface\u003cbr data-start=\"1639\" data-end=\"1642\"\u003eHigh-speed measurement with rapid response time\u003cbr data-start=\"1689\" data-end=\"1692\"\u003eLarge internal storage (16GB) for data management\u003cbr data-start=\"1741\" data-end=\"1744\"\u003eMultipoint automatic calibration for improved precision\u003cbr data-start=\"1799\" data-end=\"1802\"\u003eWide connectivity options including USB, Ethernet, and VGA\u003c\/p\u003e\n\u003ch3 data-start=\"1864\" data-end=\"1893\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"1895\" data-end=\"2639\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"1895\" data-end=\"1924\"\u003e\n\u003ctr data-start=\"1895\" data-end=\"1924\"\u003e\n\u003cth data-start=\"1895\" data-end=\"1907\" data-col-size=\"sm\" class=\"\"\u003eParameter\u003c\/th\u003e\n\u003cth data-start=\"1907\" data-end=\"1924\" data-col-size=\"sm\" class=\"\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"1935\" data-end=\"2639\"\u003e\n\u003ctr data-start=\"1935\" data-end=\"1994\"\u003e\n\u003ctd data-start=\"1935\" data-end=\"1955\" data-col-size=\"sm\"\u003eMeasurement Range\u003c\/td\u003e\n\u003ctd data-start=\"1955\" data-end=\"1994\" data-col-size=\"sm\"\u003e±90° Optical Rotation, ±259°Z Sugar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1995\" data-end=\"2023\"\u003e\n\u003ctd data-start=\"1995\" data-end=\"2013\" data-col-size=\"sm\"\u003eMinimum Reading\u003c\/td\u003e\n\u003ctd data-start=\"2013\" data-end=\"2023\" data-col-size=\"sm\"\u003e0.001°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2024\" data-end=\"2046\"\u003e\n\u003ctd data-start=\"2024\" data-end=\"2035\" data-col-size=\"sm\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd data-start=\"2035\" data-end=\"2046\" data-col-size=\"sm\"\u003e±0.004°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2047\" data-end=\"2074\"\u003e\n\u003ctd data-start=\"2047\" data-end=\"2063\" data-col-size=\"sm\"\u003eRepeatability\u003c\/td\u003e\n\u003ctd data-start=\"2063\" data-end=\"2074\" data-col-size=\"sm\"\u003e±0.002°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2075\" data-end=\"2107\"\u003e\n\u003ctd data-start=\"2075\" data-end=\"2088\" data-col-size=\"sm\"\u003eWavelength\u003c\/td\u003e\n\u003ctd data-start=\"2088\" data-end=\"2107\" data-col-size=\"sm\"\u003e546 nm \u0026amp; 589 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2108\" data-end=\"2148\"\u003e\n\u003ctd data-start=\"2108\" data-end=\"2123\" data-col-size=\"sm\"\u003eLight Source\u003c\/td\u003e\n\u003ctd data-start=\"2123\" data-end=\"2148\" data-col-size=\"sm\"\u003eTungsten Halogen Lamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2149\" data-end=\"2196\"\u003e\n\u003ctd data-start=\"2149\" data-end=\"2169\" data-col-size=\"sm\"\u003eMeasurement Speed\u003c\/td\u003e\n\u003ctd data-start=\"2169\" data-end=\"2196\" data-col-size=\"sm\"\u003e6 measurements \/ 26 sec\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2197\" data-end=\"2224\"\u003e\n\u003ctd data-start=\"2197\" data-end=\"2214\" data-col-size=\"sm\"\u003eResponse Speed\u003c\/td\u003e\n\u003ctd data-start=\"2214\" data-end=\"2224\" data-col-size=\"sm\"\u003e8°\/sec\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2225\" data-end=\"2269\"\u003e\n\u003ctd data-start=\"2225\" data-end=\"2247\" data-col-size=\"sm\"\u003eTemperature Control\u003c\/td\u003e\n\u003ctd data-start=\"2247\" data-end=\"2269\" data-col-size=\"sm\"\u003ePeltier (In-built)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2270\" data-end=\"2305\"\u003e\n\u003ctd data-start=\"2270\" data-end=\"2290\" data-col-size=\"sm\"\u003eTemperature Range\u003c\/td\u003e\n\u003ctd data-start=\"2290\" data-end=\"2305\" data-col-size=\"sm\"\u003e10°C – 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2306\" data-end=\"2339\"\u003e\n\u003ctd data-start=\"2306\" data-end=\"2329\" data-col-size=\"sm\"\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"2329\" data-end=\"2339\" data-col-size=\"sm\"\u003e±0.2°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2340\" data-end=\"2374\"\u003e\n\u003ctd data-start=\"2340\" data-end=\"2350\" data-col-size=\"sm\"\u003eDisplay\u003c\/td\u003e\n\u003ctd data-start=\"2350\" data-end=\"2374\" data-col-size=\"sm\"\u003e8\" Color Touchscreen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2375\" data-end=\"2392\"\u003e\n\u003ctd data-start=\"2375\" data-end=\"2384\" data-col-size=\"sm\"\u003eMemory\u003c\/td\u003e\n\u003ctd data-start=\"2384\" data-end=\"2392\" data-col-size=\"sm\"\u003e16GB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2393\" data-end=\"2416\"\u003e\n\u003ctd data-start=\"2393\" data-end=\"2404\" data-col-size=\"sm\"\u003eSoftware\u003c\/td\u003e\n\u003ctd data-start=\"2404\" data-end=\"2416\" data-col-size=\"sm\"\u003eIn-built\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2417\" data-end=\"2464\"\u003e\n\u003ctd data-start=\"2417\" data-end=\"2430\" data-col-size=\"sm\"\u003eCompliance\u003c\/td\u003e\n\u003ctd data-start=\"2430\" data-end=\"2464\" data-col-size=\"sm\"\u003eGMP \/ GLP \/ FDA 21 CFR Part 11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2465\" data-end=\"2516\"\u003e\n\u003ctd data-start=\"2465\" data-end=\"2477\" data-col-size=\"sm\"\u003eInterface\u003c\/td\u003e\n\u003ctd data-start=\"2477\" data-end=\"2516\" data-col-size=\"sm\"\u003eUSB, Keyboard, Mouse, VGA, Ethernet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2517\" data-end=\"2555\"\u003e\n\u003ctd data-start=\"2517\" data-end=\"2536\" data-col-size=\"sm\"\u003eTest Tube Length\u003c\/td\u003e\n\u003ctd data-start=\"2536\" data-end=\"2555\" data-col-size=\"sm\"\u003e100 mm \u0026amp; 200 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2556\" data-end=\"2584\"\u003e\n\u003ctd data-start=\"2556\" data-end=\"2571\" data-col-size=\"sm\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd data-start=\"2571\" data-end=\"2584\" data-col-size=\"sm\"\u003eAC Supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2585\" data-end=\"2620\"\u003e\n\u003ctd data-start=\"2585\" data-end=\"2598\" data-col-size=\"sm\"\u003eDimensions\u003c\/td\u003e\n\u003ctd data-start=\"2598\" data-end=\"2620\" data-col-size=\"sm\"\u003e865 × 515 × 470 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2621\" data-end=\"2639\"\u003e\n\u003ctd data-start=\"2621\" data-end=\"2630\" data-col-size=\"sm\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-start=\"2630\" data-end=\"2639\" data-col-size=\"sm\"\u003e35 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 data-start=\"2641\" data-end=\"2658\"\u003eApplications\u003c\/h3\u003e\n\u003cp data-start=\"2659\" data-end=\"2846\"\u003ePharmaceutical quality control\u003cbr data-start=\"2689\" data-end=\"2692\"\u003eSugar and food industry analysis\u003cbr data-start=\"2724\" data-end=\"2727\"\u003eChemical and petrochemical analysis\u003cbr data-start=\"2762\" data-end=\"2765\"\u003eResearch laboratories and academia\u003cbr data-start=\"2799\" data-end=\"2802\"\u003eOptical activity and concentration studies\u003c\/p\u003e","brand":"Labman","offers":[{"title":"Default Title","offer_id":49886067654893,"sku":null,"price":551000.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5672\/6765\/files\/ADP100CFR.webp?v=1778791082","url":"https:\/\/www.biotronscientific.com\/products\/high-speed-automatic-polarimeter-adp100cfr-dual-wavelength-546-589-nm-0-004-accuracy","provider":"BIOTRON","version":"1.0","type":"link"}