{"product_id":"double-beam-uv-vis-spectrophotometer-with-mercury-lamp-luv6hg-190-900-nm-pmt-detector","title":"Double Beam UV-Vis Spectrophotometer with Mercury Lamp LUV6HG (190–900 nm, PMT Detector)","description":"\u003cp data-start=\"301\" data-end=\"621\"\u003eThe Double Beam UV-Vis Spectrophotometer LUV6HG is designed for high-precision optical analysis across a wide wavelength range of 190 to 900 nm. Equipped with a double beam optical system and a highly sensitive photomultiplier tube detector, it delivers excellent signal stability and accuracy, even at low light levels.\u003c\/p\u003e\n\u003cp data-start=\"623\" data-end=\"994\"\u003eThe system integrates three built-in light sources including deuterium, tungsten, and mercury lamps. The mercury lamp enables real-time wavelength calibration, significantly improving measurement reliability and long-term accuracy. The Czerny-Turner optical system ensures high resolution and minimal stray light, making it suitable for demanding analytical applications.\u003c\/p\u003e\n\u003cp data-start=\"996\" data-end=\"1296\"\u003eThe instrument supports continuously adjustable spectral bandwidth from 0.1 nm to 5 nm, allowing flexibility for different analytical requirements, especially for samples with sharp absorption peaks. A large sample chamber accommodates standard 10 mm cells for both sample and reference measurements.\u003c\/p\u003e\n\u003cp data-start=\"1298\" data-end=\"1620\"\u003eThe system is controlled via PC software and supports advanced analytical functions such as photometric analysis, wavelength scanning, kinetic studies, and quantitative analysis. It complies with GLP\/GMP requirements and includes features such as user management, audit trails, and data logging for regulated environments.\u003c\/p\u003e\n\u003ch3 data-start=\"1622\" data-end=\"1639\"\u003eKey Features\u003c\/h3\u003e\n\u003cp data-start=\"1640\" data-end=\"2154\"\u003eDouble beam optical system for enhanced stability\u003cbr data-start=\"1689\" data-end=\"1692\"\u003ePMT detector for high sensitivity and low light detection\u003cbr data-start=\"1749\" data-end=\"1752\"\u003eDeuterium, tungsten, and mercury lamps for accurate measurement\u003cbr data-start=\"1815\" data-end=\"1818\"\u003eReal-time wavelength calibration using mercury lamp\u003cbr data-start=\"1869\" data-end=\"1872\"\u003eCzerny-Turner monochromator for high resolution\u003cbr data-start=\"1919\" data-end=\"1922\"\u003eAdjustable spectral bandwidth from 0.1 to 5 nm\u003cbr data-start=\"1968\" data-end=\"1971\"\u003eLarge sample chamber for easy handling\u003cbr data-start=\"2009\" data-end=\"2012\"\u003eAdvanced PC-based analysis software\u003cbr data-start=\"2047\" data-end=\"2050\"\u003eGLP\/GMP compliant with user management and data tracking\u003cbr data-start=\"2106\" data-end=\"2109\"\u003eLow stray light and high baseline stability\u003c\/p\u003e\n\u003ch3 data-start=\"2156\" data-end=\"2185\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"2187\" data-end=\"3036\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"2187\" data-end=\"2209\"\u003e\n\u003ctr data-start=\"2187\" data-end=\"2209\"\u003e\n\u003cth data-start=\"2187\" data-end=\"2199\" data-col-size=\"sm\" class=\"\"\u003eParameter\u003c\/th\u003e\n\u003cth data-start=\"2199\" data-end=\"2209\" data-col-size=\"sm\" class=\"\"\u003eLUV6HG\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"2232\" data-end=\"3036\"\u003e\n\u003ctr data-start=\"2232\" data-end=\"2249\"\u003e\n\u003ctd data-start=\"2232\" data-end=\"2239\" data-col-size=\"sm\"\u003eMake\u003c\/td\u003e\n\u003ctd data-start=\"2239\" data-end=\"2249\" data-col-size=\"sm\"\u003eLABMAN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2250\" data-end=\"2282\"\u003e\n\u003ctd data-start=\"2250\" data-end=\"2267\" data-col-size=\"sm\"\u003eOptical System\u003c\/td\u003e\n\u003ctd data-start=\"2267\" data-end=\"2282\" data-col-size=\"sm\"\u003eDouble Beam\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2283\" data-end=\"2324\"\u003e\n\u003ctd data-start=\"2283\" data-end=\"2294\" data-col-size=\"sm\"\u003eDetector\u003c\/td\u003e\n\u003ctd data-start=\"2294\" data-end=\"2324\" data-col-size=\"sm\"\u003ePMT (Photomultiplier Tube)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2325\" data-end=\"2373\"\u003e\n\u003ctd data-start=\"2325\" data-end=\"2341\" data-col-size=\"sm\"\u003eLight Sources\u003c\/td\u003e\n\u003ctd data-start=\"2341\" data-end=\"2373\" data-col-size=\"sm\"\u003eDeuterium, Tungsten, Mercury\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2374\" data-end=\"2409\"\u003e\n\u003ctd data-start=\"2374\" data-end=\"2393\" data-col-size=\"sm\"\u003eWavelength Range\u003c\/td\u003e\n\u003ctd data-start=\"2393\" data-end=\"2409\" data-col-size=\"sm\"\u003e190 – 900 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2410\" data-end=\"2458\"\u003e\n\u003ctd data-start=\"2410\" data-end=\"2431\" data-col-size=\"sm\"\u003eSpectral Bandwidth\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2431\" data-end=\"2458\"\u003e0.1 – 5 nm (continuous)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2459\" data-end=\"2482\"\u003e\n\u003ctd data-start=\"2459\" data-end=\"2472\" data-col-size=\"sm\"\u003eResolution\u003c\/td\u003e\n\u003ctd data-start=\"2472\" data-end=\"2482\" data-col-size=\"sm\"\u003e0.1 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2483\" data-end=\"2516\"\u003e\n\u003ctd data-start=\"2483\" data-end=\"2505\" data-col-size=\"sm\"\u003eWavelength Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"2505\" data-end=\"2516\" data-col-size=\"sm\"\u003e±0.3 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2517\" data-end=\"2568\"\u003e\n\u003ctd data-start=\"2517\" data-end=\"2537\" data-col-size=\"sm\"\u003ePhotometric Range\u003c\/td\u003e\n\u003ctd data-start=\"2537\" data-end=\"2568\" data-col-size=\"sm\"\u003e0 – 10,000,000%T, -4A to 6A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2569\" data-end=\"2601\"\u003e\n\u003ctd data-start=\"2569\" data-end=\"2592\" data-col-size=\"sm\"\u003ePhotometric Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"2592\" data-end=\"2601\" data-col-size=\"sm\"\u003e±0.3%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2602\" data-end=\"2648\"\u003e\n\u003ctd data-start=\"2602\" data-end=\"2616\" data-col-size=\"sm\"\u003eStray Light\u003c\/td\u003e\n\u003ctd data-start=\"2616\" data-end=\"2648\" data-col-size=\"sm\"\u003e≤0.005% (at 220 nm \u0026amp; 360 nm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2649\" data-end=\"2684\"\u003e\n\u003ctd data-start=\"2649\" data-end=\"2669\" data-col-size=\"sm\"\u003eBaseline Flatness\u003c\/td\u003e\n\u003ctd data-start=\"2669\" data-end=\"2684\" data-col-size=\"sm\"\u003e±0.0005 Abs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2685\" data-end=\"2714\"\u003e\n\u003ctd data-start=\"2685\" data-end=\"2697\" data-col-size=\"sm\"\u003eStability\u003c\/td\u003e\n\u003ctd data-start=\"2697\" data-end=\"2714\" data-col-size=\"sm\"\u003e≤0.0001 Abs\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2715\" data-end=\"2759\"\u003e\n\u003ctd data-start=\"2715\" data-end=\"2729\" data-col-size=\"sm\"\u003eCell Holder\u003c\/td\u003e\n\u003ctd data-start=\"2729\" data-end=\"2759\" data-col-size=\"sm\"\u003e10 mm (Sample \u0026amp; Reference)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2760\" data-end=\"2786\"\u003e\n\u003ctd data-start=\"2760\" data-end=\"2777\" data-col-size=\"sm\"\u003eSample Chamber\u003c\/td\u003e\n\u003ctd data-start=\"2777\" data-end=\"2786\" data-col-size=\"sm\"\u003eLarge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2787\" data-end=\"2823\"\u003e\n\u003ctd data-start=\"2787\" data-end=\"2799\" data-col-size=\"sm\"\u003eInterface\u003c\/td\u003e\n\u003ctd data-start=\"2799\" data-end=\"2823\" data-col-size=\"sm\"\u003eUSB, RS232, Ethernet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2824\" data-end=\"2850\"\u003e\n\u003ctd data-start=\"2824\" data-end=\"2837\" data-col-size=\"sm\"\u003eCompliance\u003c\/td\u003e\n\u003ctd data-start=\"2837\" data-end=\"2850\" data-col-size=\"sm\"\u003eGLP \/ GMP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2851\" data-end=\"2880\"\u003e\n\u003ctd data-start=\"2851\" data-end=\"2873\" data-col-size=\"sm\"\u003ePassword Protection\u003c\/td\u003e\n\u003ctd data-start=\"2873\" data-end=\"2880\" data-col-size=\"sm\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2881\" data-end=\"2936\"\u003e\n\u003ctd data-start=\"2881\" data-end=\"2902\" data-col-size=\"sm\"\u003eScanning Intervals\u003c\/td\u003e\n\u003ctd data-start=\"2902\" data-end=\"2936\" data-col-size=\"sm\"\u003e0.025 to 5 nm (multiple steps)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2937\" data-end=\"2973\"\u003e\n\u003ctd data-start=\"2937\" data-end=\"2952\" data-col-size=\"sm\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd data-start=\"2952\" data-end=\"2973\" data-col-size=\"sm\"\u003eAC 220V \/ 50-60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2974\" data-end=\"3017\"\u003e\n\u003ctd data-start=\"2974\" data-end=\"2995\" data-col-size=\"sm\"\u003eDimensions (L×W×H)\u003c\/td\u003e\n\u003ctd data-start=\"2995\" data-end=\"3017\" data-col-size=\"sm\"\u003e710 × 690 × 540 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3018\" data-end=\"3036\"\u003e\n\u003ctd data-start=\"3018\" data-end=\"3027\" data-col-size=\"sm\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-start=\"3027\" data-end=\"3036\" data-col-size=\"sm\"\u003e49 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 data-start=\"3038\" data-end=\"3055\"\u003eApplications\u003c\/h3\u003e\n\u003cp data-start=\"3056\" data-end=\"3247\"\u003ePharmaceutical analysis and quality control\u003cbr data-start=\"3099\" data-end=\"3102\"\u003eChemical and environmental analysis\u003cbr data-start=\"3137\" data-end=\"3140\"\u003eBiotechnology and life sciences research\u003cbr data-start=\"3180\" data-end=\"3183\"\u003eFood and beverage testing\u003cbr data-start=\"3208\" data-end=\"3211\"\u003eAcademic and research laboratories\u003c\/p\u003e","brand":"Labman","offers":[{"title":"Default Title","offer_id":49929398190317,"sku":null,"price":700000.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5672\/6765\/files\/LUV6HG.webp?v=1778877230","url":"https:\/\/www.biotronscientific.com\/products\/double-beam-uv-vis-spectrophotometer-with-mercury-lamp-luv6hg-190-900-nm-pmt-detector","provider":"BIOTRON","version":"1.0","type":"link"}