{"product_id":"benchtop-ph-mv-c-meter-with-5-point-calibration","title":"Benchtop pH\/mV\/°C Meter with 5-Point Calibration","description":"\u003cp data-start=\"244\" data-end=\"602\"\u003eBenchtop pH\/mV\/°C Meter LMPH12 is a high-precision laboratory instrument designed for accurate pH, mV, ORP, and temperature measurement across research, pharmaceutical, environmental, and industrial testing applications. The instrument combines advanced calibration capability with intelligent diagnostic functions to deliver reliable analytical performance.\u003c\/p\u003e\n\u003cp data-start=\"604\" data-end=\"961\"\u003eThe system features a large backlit LCD display with user guidance prompts for simplified operation and efficient sample analysis. Automatic temperature compensation ensures accurate measurement across the entire operating range, while automatic electrode diagnostics display electrode slope after calibration for improved monitoring of electrode condition.\u003c\/p\u003e\n\u003cp data-start=\"963\" data-end=\"1226\"\u003eThe meter supports up to five-point push-button calibration with automatic buffer recognition and selectable buffer standards. It also includes calibration due reminders, helping laboratories maintain measurement accuracy through scheduled recalibration routines.\u003c\/p\u003e\n\u003cp data-start=\"1228\" data-end=\"1454\"\u003eThe instrument supports both absolute and relative millivolt measurement for precise ORP analysis. Automatic endpoint detection freezes stable measured values for consistent recording and improved repeatability during testing.\u003c\/p\u003e\n\u003cp data-start=\"1456\" data-end=\"1795\"\u003eAn expanded internal memory allows storage of up to 500 readings with date and time stamping to support GLP-compliant laboratory documentation. The setup menu enables users to customize calibration points, buffer standards, resolution, temperature units, stability conditions, and operational settings according to laboratory requirements.\u003c\/p\u003e\n\u003cp data-start=\"1797\" data-end=\"1951\"\u003eLMPH12 is suitable for laboratories requiring advanced pH analysis with high accuracy, flexible calibration, and comprehensive data management capability.\u003c\/p\u003e\n\u003ch3 data-start=\"1953\" data-end=\"1968\"\u003eKey Features\u003c\/h3\u003e\n\u003cp data-start=\"1970\" data-end=\"2543\"\u003eHigh precision pH, mV, ORP, and temperature measurement\u003cbr data-start=\"2025\" data-end=\"2028\"\u003eUp to 5-point calibration with auto buffer recognition\u003cbr data-start=\"2082\" data-end=\"2085\"\u003eAutomatic temperature compensation (ATC)\u003cbr data-start=\"2125\" data-end=\"2128\"\u003eAutomatic electrode slope diagnostics\u003cbr data-start=\"2165\" data-end=\"2168\"\u003eLarge LCD display with backlight\u003cbr data-start=\"2200\" data-end=\"2203\"\u003eAbsolute and relative mV measurement capability\u003cbr data-start=\"2250\" data-end=\"2253\"\u003eAutomatic endpoint detection function\u003cbr data-start=\"2290\" data-end=\"2293\"\u003eCalibration reminder system\u003cbr data-start=\"2320\" data-end=\"2323\"\u003eInternal memory for up to 500 readings\u003cbr data-start=\"2361\" data-end=\"2364\"\u003eDate and time stamped data storage\u003cbr data-start=\"2398\" data-end=\"2401\"\u003eSelectable pH resolution and mV resolution\u003cbr data-start=\"2443\" data-end=\"2446\"\u003eCustomizable setup and calibration parameters\u003cbr data-start=\"2491\" data-end=\"2494\"\u003eSuitable for research and industrial laboratories\u003c\/p\u003e\n\u003ch3 data-start=\"2545\" data-end=\"2572\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"2574\" data-end=\"3278\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"2574\" data-end=\"2603\"\u003e\n\u003ctr data-start=\"2574\" data-end=\"2603\"\u003e\n\u003cth data-start=\"2574\" data-end=\"2586\" data-col-size=\"sm\" class=\"\"\u003eParameter\u003c\/th\u003e\n\u003cth data-start=\"2586\" data-end=\"2603\" data-col-size=\"sm\" class=\"\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"2618\" data-end=\"3278\"\u003e\n\u003ctr data-start=\"2618\" data-end=\"2652\"\u003e\n\u003ctd data-start=\"2618\" data-end=\"2629\" data-col-size=\"sm\"\u003epH Range\u003c\/td\u003e\n\u003ctd data-start=\"2629\" data-end=\"2652\" data-col-size=\"sm\"\u003e-2.000 to 20.000 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2653\" data-end=\"2680\"\u003e\n\u003ctd data-start=\"2653\" data-end=\"2667\" data-col-size=\"sm\"\u003epH Accuracy\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2667\" data-end=\"2680\"\u003e±0.002 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2681\" data-end=\"2733\"\u003e\n\u003ctd data-start=\"2681\" data-end=\"2697\" data-col-size=\"sm\"\u003epH Resolution\u003c\/td\u003e\n\u003ctd data-start=\"2697\" data-end=\"2733\" data-col-size=\"sm\"\u003e0.001, 0.01, 0.1 pH (Selectable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2734\" data-end=\"2757\"\u003e\n\u003ctd data-start=\"2734\" data-end=\"2745\" data-col-size=\"sm\"\u003emV Range\u003c\/td\u003e\n\u003ctd data-start=\"2745\" data-end=\"2757\" data-col-size=\"sm\"\u003e±1999 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2758\" data-end=\"2783\"\u003e\n\u003ctd data-start=\"2758\" data-end=\"2772\" data-col-size=\"sm\"\u003emV Accuracy\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2772\" data-end=\"2783\"\u003e±0.2 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2784\" data-end=\"2826\"\u003e\n\u003ctd data-start=\"2784\" data-end=\"2800\" data-col-size=\"sm\"\u003emV Resolution\u003c\/td\u003e\n\u003ctd data-start=\"2800\" data-end=\"2826\" data-col-size=\"sm\"\u003e0.1, 1 mV (Selectable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2827\" data-end=\"2859\"\u003e\n\u003ctd data-start=\"2827\" data-end=\"2841\" data-col-size=\"sm\"\u003eCalibration\u003c\/td\u003e\n\u003ctd data-start=\"2841\" data-end=\"2859\" data-col-size=\"sm\"\u003eUp to 5 Points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2860\" data-end=\"2905\"\u003e\n\u003ctd data-start=\"2860\" data-end=\"2877\" data-col-size=\"sm\"\u003eBuffer Options\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2877\" data-end=\"2905\"\u003eUSA, NIST \u0026amp; User Defined\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2906\" data-end=\"2952\"\u003e\n\u003ctd data-start=\"2906\" data-end=\"2929\" data-col-size=\"sm\"\u003eCalibration Reminder\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2929\" data-end=\"2952\"\u003e1 to 30 Days or Off\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2953\" data-end=\"2996\"\u003e\n\u003ctd data-start=\"2953\" data-end=\"2973\" data-col-size=\"sm\"\u003eTemperature Range\u003c\/td\u003e\n\u003ctd data-start=\"2973\" data-end=\"2996\" data-col-size=\"sm\"\u003e0°–105°C, 32°–212°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2997\" data-end=\"3038\"\u003e\n\u003ctd data-start=\"2997\" data-end=\"3020\" data-col-size=\"sm\"\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3020\" data-end=\"3038\"\u003e±0.5°C, ±0.9°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3039\" data-end=\"3089\"\u003e\n\u003ctd data-start=\"3039\" data-end=\"3066\" data-col-size=\"sm\"\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd data-start=\"3066\" data-end=\"3089\" data-col-size=\"sm\"\u003eAutomatic or Manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3090\" data-end=\"3124\"\u003e\n\u003ctd data-start=\"3090\" data-end=\"3101\" data-col-size=\"sm\"\u003eAuto-Off\u003c\/td\u003e\n\u003ctd data-start=\"3101\" data-end=\"3124\" data-col-size=\"sm\"\u003eManual or Automatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3125\" data-end=\"3167\"\u003e\n\u003ctd data-start=\"3125\" data-end=\"3134\" data-col-size=\"sm\"\u003eMemory\u003c\/td\u003e\n\u003ctd data-start=\"3134\" data-end=\"3167\" data-col-size=\"sm\"\u003e500 Readings with Date \u0026amp; Time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3168\" data-end=\"3216\"\u003e\n\u003ctd data-start=\"3168\" data-end=\"3183\" data-col-size=\"sm\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd data-start=\"3183\" data-end=\"3216\" data-col-size=\"sm\"\u003eDC Adaptor, AC 220V \/ 50–60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3217\" data-end=\"3260\"\u003e\n\u003ctd data-start=\"3217\" data-end=\"3238\" data-col-size=\"sm\"\u003eDimensions (L×W×H)\u003c\/td\u003e\n\u003ctd data-start=\"3238\" data-end=\"3260\" data-col-size=\"sm\"\u003e310 × 250 × 190 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3261\" data-end=\"3278\"\u003e\n\u003ctd data-start=\"3261\" data-end=\"3270\" data-col-size=\"sm\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-start=\"3270\" data-end=\"3278\" data-col-size=\"sm\"\u003e2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 data-start=\"3280\" data-end=\"3295\"\u003eApplications\u003c\/h3\u003e\n\u003cp data-start=\"3297\" data-end=\"3503\"\u003ePharmaceutical laboratory analysis\u003cbr data-start=\"3331\" data-end=\"3334\"\u003eWater and wastewater testing\u003cbr data-start=\"3362\" data-end=\"3365\"\u003eEnvironmental monitoring\u003cbr data-start=\"3389\" data-end=\"3392\"\u003eChemical and industrial quality control\u003cbr data-start=\"3431\" data-end=\"3434\"\u003eResearch and academic laboratories\u003cbr data-start=\"3468\" data-end=\"3471\"\u003eORP and electrochemical analysis\u003c\/p\u003e","brand":"Labman","offers":[{"title":"Default Title","offer_id":49968478093549,"sku":null,"price":45000.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5672\/6765\/files\/LMPH12.jpg?v=1778960645","url":"https:\/\/www.biotronscientific.com\/products\/benchtop-ph-mv-c-meter-with-5-point-calibration","provider":"BIOTRON","version":"1.0","type":"link"}