{"product_id":"benchtop-ph-meter-with-thermal-printer-and-5-point-calibration","title":"Benchtop pH Meter LMPH15 (Thermal Printer, 5-Point Calibration)","description":"\u003cp data-start=\"272\" data-end=\"652\"\u003eBenchtop pH Meter with Thermal Printer LMPH15 is a high-precision laboratory instrument designed for accurate pH, ORP, mV, and temperature measurement with integrated printing and advanced data management functionality. The system is suitable for pharmaceutical laboratories, research facilities, environmental testing, water analysis, and industrial quality control applications.\u003c\/p\u003e\n\u003cp data-start=\"654\" data-end=\"913\"\u003eThe instrument supports 1 to 5 point calibration with automatic recognition of USA, NIST, DIN, and user-defined buffer standards. Automatic electrode diagnostics continuously monitor electrode slope and zero offset to maintain reliable analytical performance.\u003c\/p\u003e\n\u003cp data-start=\"915\" data-end=\"1181\"\u003eThe integrated thermal printer enables direct printing of interval readings and measurement reports, improving laboratory documentation and traceability. Built-in real-time clock functionality supports GLP-compliant data records with accurate date and time stamping.\u003c\/p\u003e\n\u003cp data-start=\"1183\" data-end=\"1472\"\u003eLMPH15 provides both relative and absolute millivolt measurement modes for reliable ORP analysis. Automatic temperature compensation ensures stable and accurate readings across the measurement range, while auto-read endpoint sensing locks stable measured values for improved repeatability.\u003c\/p\u003e\n\u003cp data-start=\"1474\" data-end=\"1762\"\u003eThe system also includes calibration due alarms, password protection for calibration settings, high\/low limit alarm functions, and internal memory storage for up to 1000 data sets. A large 7-inch TFT LCD display provides clear visualization of measurement values and operational settings.\u003c\/p\u003e\n\u003cp data-start=\"1764\" data-end=\"1921\"\u003eDesigned for advanced laboratory workflows, the instrument combines high analytical accuracy with integrated reporting and secure data handling capabilities.\u003c\/p\u003e\n\u003ch3 data-start=\"1923\" data-end=\"1938\"\u003eKey Features\u003c\/h3\u003e\n\u003cp data-start=\"1940\" data-end=\"2535\"\u003eIntegrated thermal printer for direct result printing\u003cbr data-start=\"1993\" data-end=\"1996\"\u003e1 to 5 point calibration with auto buffer recognition\u003cbr data-start=\"2049\" data-end=\"2052\"\u003eSupports USA, NIST, DIN, and user-defined buffers\u003cbr data-start=\"2101\" data-end=\"2104\"\u003eAutomatic temperature compensation (ATC)\u003cbr data-start=\"2144\" data-end=\"2147\"\u003eORP and mV measurement capability\u003cbr data-start=\"2180\" data-end=\"2183\"\u003eAutomatic electrode diagnostics\u003cbr data-start=\"2214\" data-end=\"2217\"\u003eAuto-read endpoint sensing function\u003cbr data-start=\"2252\" data-end=\"2255\"\u003e7-inch TFT LCD display\u003cbr data-start=\"2277\" data-end=\"2280\"\u003ePassword protection for calibration settings\u003cbr data-start=\"2324\" data-end=\"2327\"\u003eHigh and low limit alarm system\u003cbr data-start=\"2358\" data-end=\"2361\"\u003eGLP-compliant real-time clock data stamping\u003cbr data-start=\"2404\" data-end=\"2407\"\u003eMemory storage for up to 1000 data sets\u003cbr data-start=\"2446\" data-end=\"2449\"\u003eRelative and absolute mV measurement modes\u003cbr data-start=\"2491\" data-end=\"2494\"\u003eSuitable for advanced laboratory analysis\u003c\/p\u003e\n\u003ch3 data-start=\"2537\" data-end=\"2564\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"2566\" data-end=\"3413\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"2566\" data-end=\"2595\"\u003e\n\u003ctr data-start=\"2566\" data-end=\"2595\"\u003e\n\u003cth data-start=\"2566\" data-end=\"2578\" data-col-size=\"sm\" class=\"\"\u003eParameter\u003c\/th\u003e\n\u003cth data-start=\"2578\" data-end=\"2595\" data-col-size=\"sm\" class=\"\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"2610\" data-end=\"3413\"\u003e\n\u003ctr data-start=\"2610\" data-end=\"2644\"\u003e\n\u003ctd data-start=\"2610\" data-end=\"2621\" data-col-size=\"sm\"\u003epH Range\u003c\/td\u003e\n\u003ctd data-start=\"2621\" data-end=\"2644\" data-col-size=\"sm\"\u003e-2.000 to 20.000 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2645\" data-end=\"2689\"\u003e\n\u003ctd data-start=\"2645\" data-end=\"2661\" data-col-size=\"sm\"\u003epH Resolution\u003c\/td\u003e\n\u003ctd data-start=\"2661\" data-end=\"2689\" data-col-size=\"sm\"\u003e0.001, 0.01 (Selectable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2690\" data-end=\"2717\"\u003e\n\u003ctd data-start=\"2690\" data-end=\"2704\" data-col-size=\"sm\"\u003epH Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"2704\" data-end=\"2717\" data-col-size=\"sm\"\u003e±0.002 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2718\" data-end=\"2757\"\u003e\n\u003ctd data-start=\"2718\" data-end=\"2739\" data-col-size=\"sm\"\u003eCalibration Points\u003c\/td\u003e\n\u003ctd data-start=\"2739\" data-end=\"2757\" data-col-size=\"sm\"\u003eUp to 5 Points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2758\" data-end=\"2807\"\u003e\n\u003ctd data-start=\"2758\" data-end=\"2775\" data-col-size=\"sm\"\u003eBuffer Options\u003c\/td\u003e\n\u003ctd data-start=\"2775\" data-end=\"2807\" data-col-size=\"sm\"\u003eUSA, NIST, DIN, User Defined\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2808\" data-end=\"2831\"\u003e\n\u003ctd data-start=\"2808\" data-end=\"2819\" data-col-size=\"sm\"\u003emV Range\u003c\/td\u003e\n\u003ctd data-start=\"2819\" data-end=\"2831\" data-col-size=\"sm\"\u003e±2000 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2832\" data-end=\"2857\"\u003e\n\u003ctd data-start=\"2832\" data-end=\"2846\" data-col-size=\"sm\"\u003emV Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"2846\" data-end=\"2857\" data-col-size=\"sm\"\u003e±0.2 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2858\" data-end=\"2884\"\u003e\n\u003ctd data-start=\"2858\" data-end=\"2874\" data-col-size=\"sm\"\u003emV Resolution\u003c\/td\u003e\n\u003ctd data-start=\"2874\" data-end=\"2884\" data-col-size=\"sm\"\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2885\" data-end=\"2929\"\u003e\n\u003ctd data-start=\"2885\" data-end=\"2905\" data-col-size=\"sm\"\u003eTemperature Range\u003c\/td\u003e\n\u003ctd data-start=\"2905\" data-end=\"2929\" data-col-size=\"sm\"\u003e0°–105°C \/ 32°–221°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2930\" data-end=\"2972\"\u003e\n\u003ctd data-start=\"2930\" data-end=\"2953\" data-col-size=\"sm\"\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"2953\" data-end=\"2972\" data-col-size=\"sm\"\u003e±0.5°C \/ ±0.9°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2973\" data-end=\"3015\"\u003e\n\u003ctd data-start=\"2973\" data-end=\"2998\" data-col-size=\"sm\"\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd data-start=\"2998\" data-end=\"3015\" data-col-size=\"sm\"\u003e0.1°C \/ 0.1°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3016\" data-end=\"3065\"\u003e\n\u003ctd data-start=\"3016\" data-end=\"3043\" data-col-size=\"sm\"\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd data-start=\"3043\" data-end=\"3065\" data-col-size=\"sm\"\u003eManual \/ Automatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3066\" data-end=\"3095\"\u003e\n\u003ctd data-start=\"3066\" data-end=\"3084\" data-col-size=\"sm\"\u003eInput Impedance\u003c\/td\u003e\n\u003ctd data-start=\"3084\" data-end=\"3095\" data-col-size=\"sm\"\u003e\u0026lt;10¹² Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3096\" data-end=\"3137\"\u003e\n\u003ctd data-start=\"3096\" data-end=\"3108\" data-col-size=\"sm\"\u003eStability\u003c\/td\u003e\n\u003ctd data-start=\"3108\" data-end=\"3137\" data-col-size=\"sm\"\u003eStandard or High Accuracy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3138\" data-end=\"3185\"\u003e\n\u003ctd data-start=\"3138\" data-end=\"3162\" data-col-size=\"sm\"\u003eCalibration Due Alarm\u003c\/td\u003e\n\u003ctd data-start=\"3162\" data-end=\"3185\" data-col-size=\"sm\"\u003e1 to 31 Days or Off\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3186\" data-end=\"3225\"\u003e\n\u003ctd data-start=\"3186\" data-end=\"3208\" data-col-size=\"sm\"\u003ePassword Protection\u003c\/td\u003e\n\u003ctd data-start=\"3208\" data-end=\"3225\" data-col-size=\"sm\"\u003eYes, 4 Digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3226\" data-end=\"3253\"\u003e\n\u003ctd data-start=\"3226\" data-end=\"3235\" data-col-size=\"sm\"\u003eMemory\u003c\/td\u003e\n\u003ctd data-start=\"3235\" data-end=\"3253\" data-col-size=\"sm\"\u003e1000 Data Sets\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3254\" data-end=\"3273\"\u003e\n\u003ctd data-start=\"3254\" data-end=\"3266\" data-col-size=\"sm\"\u003eConnector\u003c\/td\u003e\n\u003ctd data-start=\"3266\" data-end=\"3273\" data-col-size=\"sm\"\u003eBNC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3274\" data-end=\"3302\"\u003e\n\u003ctd data-start=\"3274\" data-end=\"3284\" data-col-size=\"sm\"\u003eDisplay\u003c\/td\u003e\n\u003ctd data-start=\"3284\" data-end=\"3302\" data-col-size=\"sm\"\u003e7-inch TFT LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3303\" data-end=\"3351\"\u003e\n\u003ctd data-start=\"3303\" data-end=\"3318\" data-col-size=\"sm\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd data-start=\"3318\" data-end=\"3351\" data-col-size=\"sm\"\u003eDC Adaptor, AC 220V \/ 50–60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3352\" data-end=\"3395\"\u003e\n\u003ctd data-start=\"3352\" data-end=\"3373\" data-col-size=\"sm\"\u003eDimensions (L×W×H)\u003c\/td\u003e\n\u003ctd data-start=\"3373\" data-end=\"3395\" data-col-size=\"sm\"\u003e330 × 235 × 420 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3396\" data-end=\"3413\"\u003e\n\u003ctd data-start=\"3396\" data-end=\"3405\" data-col-size=\"sm\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-start=\"3405\" data-end=\"3413\" data-col-size=\"sm\"\u003e2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 data-start=\"3415\" data-end=\"3430\"\u003eApplications\u003c\/h3\u003e\n\u003cp data-start=\"3432\" data-end=\"3679\"\u003ePharmaceutical laboratory analysis\u003cbr data-start=\"3466\" data-end=\"3469\"\u003eWater and wastewater testing\u003cbr data-start=\"3497\" data-end=\"3500\"\u003eEnvironmental monitoring\u003cbr data-start=\"3524\" data-end=\"3527\"\u003eChemical and industrial quality control\u003cbr data-start=\"3566\" data-end=\"3569\"\u003eResearch and academic laboratories\u003cbr data-start=\"3603\" data-end=\"3606\"\u003eORP and electrochemical analysis\u003cbr data-start=\"3638\" data-end=\"3641\"\u003eGLP-compliant laboratory documentation\u003c\/p\u003e","brand":"Labman","offers":[{"title":"Default Title","offer_id":49968482025709,"sku":null,"price":70000.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5672\/6765\/files\/LMPH15.webp?v=1778960706","url":"https:\/\/www.biotronscientific.com\/products\/benchtop-ph-meter-with-thermal-printer-and-5-point-calibration","provider":"BIOTRON","version":"1.0","type":"link"}