{"product_id":"benchtop-ion-ph-mv-temperature-meter-for-laboratory-analysis","title":"Benchtop ION pH mV Temperature Meter LMION40","description":"\u003cp data-start=\"255\" data-end=\"595\"\u003eBenchtop ION\/pH\/mV\/°C Meter LMION40 is a high-accuracy laboratory instrument designed for ion concentration, pH, ORP, mV, and temperature measurement in research, environmental, industrial, and academic laboratories. The system combines advanced ion analysis with precision pH measurement to support a wide range of analytical applications.\u003c\/p\u003e\n\u003cp data-start=\"597\" data-end=\"914\"\u003eThe instrument supports up to 5-point pH calibration with automatic buffer recognition and selectable international buffer standards including USA, NIST, DIN, and user-defined options. Automatic electrode diagnostics calculate and display electrode slope after calibration to maintain reliable analytical performance.\u003c\/p\u003e\n\u003cp data-start=\"916\" data-end=\"1210\"\u003eLMION40 provides advanced ion concentration analysis with support for ion selective electrodes and multiple concentration units including ppm, mg\/L, mol\/L, and percentage concentration measurements. The system allows 2 to 5-point ion calibration for accurate low-to-high concentration analysis.\u003c\/p\u003e\n\u003cp data-start=\"1212\" data-end=\"1447\"\u003eThe meter also supports ORP and relative mV measurement with selectable calibration and stability conditions. Automatic temperature compensation ensures accurate readings across varying sample temperatures and environmental conditions.\u003c\/p\u003e\n\u003cp data-start=\"1449\" data-end=\"1719\"\u003eA large LCD interface with operational guidance simplifies routine operation and setup. The instrument features automatic endpoint detection, calibration reminders, real-time clock stamping, and internal memory for storing up to 500 data sets with date and time records.\u003c\/p\u003e\n\u003cp data-start=\"1721\" data-end=\"1962\"\u003eLMION40 is suitable for water quality testing, environmental monitoring, chemical laboratories, pharmaceutical analysis, educational institutions, food processing, and ion concentration studies requiring accurate electrochemical measurement.\u003c\/p\u003e\n\u003ch3 data-start=\"1964\" data-end=\"1979\"\u003eKey Features\u003c\/h3\u003e\n\u003cp data-start=\"1981\" data-end=\"2576\"\u003epH, ion concentration, ORP, mV, and temperature measurement\u003cbr data-start=\"2040\" data-end=\"2043\"\u003eHigh-accuracy ion selective electrode analysis\u003cbr data-start=\"2089\" data-end=\"2092\"\u003eUp to 5-point pH and ion calibration\u003cbr data-start=\"2128\" data-end=\"2131\"\u003eAutomatic buffer recognition with multiple standards\u003cbr data-start=\"2183\" data-end=\"2186\"\u003eAutomatic electrode slope calculation and diagnostics\u003cbr data-start=\"2239\" data-end=\"2242\"\u003eAutomatic temperature compensation\u003cbr data-start=\"2276\" data-end=\"2279\"\u003eAutomatic endpoint detection for stable readings\u003cbr data-start=\"2327\" data-end=\"2330\"\u003eSelectable concentration units including ppm and mol\/L\u003cbr data-start=\"2384\" data-end=\"2387\"\u003eUSB communication interface for data transfer\u003cbr data-start=\"2432\" data-end=\"2435\"\u003eMemory storage for up to 500 data sets\u003cbr data-start=\"2473\" data-end=\"2476\"\u003eCalibration due reminder and stability selection\u003cbr data-start=\"2524\" data-end=\"2527\"\u003eSuitable for laboratory and environmental testing\u003c\/p\u003e\n\u003ch3 data-start=\"2578\" data-end=\"2605\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"2607\" data-end=\"3675\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"2607\" data-end=\"2636\"\u003e\n\u003ctr data-start=\"2607\" data-end=\"2636\"\u003e\n\u003cth data-start=\"2607\" data-end=\"2619\" data-col-size=\"sm\" class=\"\"\u003eParameter\u003c\/th\u003e\n\u003cth data-start=\"2619\" data-end=\"2636\" data-col-size=\"md\" class=\"\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"2651\" data-end=\"3675\"\u003e\n\u003ctr data-start=\"2651\" data-end=\"2685\"\u003e\n\u003ctd data-start=\"2651\" data-end=\"2662\" data-col-size=\"sm\"\u003epH Range\u003c\/td\u003e\n\u003ctd data-start=\"2662\" data-end=\"2685\" data-col-size=\"md\"\u003e-2.000 to 20.000 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2686\" data-end=\"2713\"\u003e\n\u003ctd data-start=\"2686\" data-end=\"2700\" data-col-size=\"sm\"\u003epH Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"2700\" data-end=\"2713\" data-col-size=\"md\"\u003e±0.002 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2714\" data-end=\"2753\"\u003e\n\u003ctd data-start=\"2714\" data-end=\"2730\" data-col-size=\"sm\"\u003epH Resolution\u003c\/td\u003e\n\u003ctd data-start=\"2730\" data-end=\"2753\" data-col-size=\"md\"\u003e0.001, 0.01, 0.1 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2754\" data-end=\"2796\"\u003e\n\u003ctd data-start=\"2754\" data-end=\"2778\" data-col-size=\"sm\"\u003epH Calibration Points\u003c\/td\u003e\n\u003ctd data-start=\"2778\" data-end=\"2796\" data-col-size=\"md\"\u003eUp to 5 Points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2797\" data-end=\"2855\"\u003e\n\u003ctd data-start=\"2797\" data-end=\"2823\" data-col-size=\"sm\"\u003eIon Concentration Range\u003c\/td\u003e\n\u003ctd data-start=\"2823\" data-end=\"2855\" data-col-size=\"md\"\u003e0.001–19999 ppm, mg\/L, mol\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2856\" data-end=\"2931\"\u003e\n\u003ctd data-start=\"2856\" data-end=\"2871\" data-col-size=\"sm\"\u003eIon Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"2871\" data-end=\"2931\" data-col-size=\"md\"\u003e±0.5% Full Scale (Monovalent), ±1% Full Scale (Divalent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2932\" data-end=\"2972\"\u003e\n\u003ctd data-start=\"2932\" data-end=\"2949\" data-col-size=\"sm\"\u003eIon Resolution\u003c\/td\u003e\n\u003ctd data-start=\"2949\" data-end=\"2972\" data-col-size=\"md\"\u003e0.001, 0.01, 0.1, 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2973\" data-end=\"3016\"\u003e\n\u003ctd data-start=\"2973\" data-end=\"2998\" data-col-size=\"sm\"\u003eIon Calibration Points\u003c\/td\u003e\n\u003ctd data-start=\"2998\" data-end=\"3016\" data-col-size=\"md\"\u003eUp to 5 Points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3017\" data-end=\"3042\"\u003e\n\u003ctd data-start=\"3017\" data-end=\"3028\" data-col-size=\"sm\"\u003emV Range\u003c\/td\u003e\n\u003ctd data-start=\"3028\" data-end=\"3042\" data-col-size=\"md\"\u003e±1999.9 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3043\" data-end=\"3068\"\u003e\n\u003ctd data-start=\"3043\" data-end=\"3057\" data-col-size=\"sm\"\u003emV Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"3057\" data-end=\"3068\" data-col-size=\"md\"\u003e±0.2 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3069\" data-end=\"3099\"\u003e\n\u003ctd data-start=\"3069\" data-end=\"3085\" data-col-size=\"sm\"\u003emV Resolution\u003c\/td\u003e\n\u003ctd data-start=\"3085\" data-end=\"3099\" data-col-size=\"md\"\u003e0.1 \/ 1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3100\" data-end=\"3128\"\u003e\n\u003ctd data-start=\"3100\" data-end=\"3117\" data-col-size=\"sm\"\u003emV Calibration\u003c\/td\u003e\n\u003ctd data-start=\"3117\" data-end=\"3128\" data-col-size=\"md\"\u003e1 Point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3129\" data-end=\"3160\"\u003e\n\u003ctd data-start=\"3129\" data-end=\"3149\" data-col-size=\"sm\"\u003eTemperature Range\u003c\/td\u003e\n\u003ctd data-start=\"3149\" data-end=\"3160\" data-col-size=\"md\"\u003e0–105°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3161\" data-end=\"3194\"\u003e\n\u003ctd data-start=\"3161\" data-end=\"3184\" data-col-size=\"sm\"\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"3184\" data-end=\"3194\" data-col-size=\"md\"\u003e±0.5°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3195\" data-end=\"3229\"\u003e\n\u003ctd data-start=\"3195\" data-end=\"3220\" data-col-size=\"sm\"\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd data-start=\"3220\" data-end=\"3229\" data-col-size=\"md\"\u003e0.1°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3230\" data-end=\"3282\"\u003e\n\u003ctd data-start=\"3230\" data-end=\"3250\" data-col-size=\"sm\"\u003epH Buffer Options\u003c\/td\u003e\n\u003ctd data-start=\"3250\" data-end=\"3282\" data-col-size=\"md\"\u003eUSA, NIST, DIN, User Defined\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3283\" data-end=\"3326\"\u003e\n\u003ctd data-start=\"3283\" data-end=\"3292\" data-col-size=\"sm\"\u003eMemory\u003c\/td\u003e\n\u003ctd data-start=\"3292\" data-end=\"3326\" data-col-size=\"md\"\u003e500 Data Sets with Date \u0026amp; Time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3327\" data-end=\"3367\"\u003e\n\u003ctd data-start=\"3327\" data-end=\"3336\" data-col-size=\"sm\"\u003eOutput\u003c\/td\u003e\n\u003ctd data-start=\"3336\" data-end=\"3367\" data-col-size=\"md\"\u003eUSB Communication Interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3368\" data-end=\"3387\"\u003e\n\u003ctd data-start=\"3368\" data-end=\"3380\" data-col-size=\"sm\"\u003eConnector\u003c\/td\u003e\n\u003ctd data-start=\"3380\" data-end=\"3387\" data-col-size=\"md\"\u003eBNC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3388\" data-end=\"3418\"\u003e\n\u003ctd data-start=\"3388\" data-end=\"3404\" data-col-size=\"sm\"\u003eHold Function\u003c\/td\u003e\n\u003ctd data-start=\"3404\" data-end=\"3418\" data-col-size=\"md\"\u003eSelectable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3419\" data-end=\"3469\"\u003e\n\u003ctd data-start=\"3419\" data-end=\"3446\" data-col-size=\"sm\"\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd data-start=\"3446\" data-end=\"3469\" data-col-size=\"md\"\u003eAutomatic or Manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3470\" data-end=\"3520\"\u003e\n\u003ctd data-start=\"3470\" data-end=\"3493\" data-col-size=\"sm\"\u003eStability Conditions\u003c\/td\u003e\n\u003ctd data-start=\"3493\" data-end=\"3520\" data-col-size=\"md\"\u003eLow or High, Selectable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3521\" data-end=\"3564\"\u003e\n\u003ctd data-start=\"3521\" data-end=\"3548\" data-col-size=\"sm\"\u003eCalibration Due Reminder\u003c\/td\u003e\n\u003ctd data-start=\"3548\" data-end=\"3564\" data-col-size=\"md\"\u003e1 to 31 Days\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3565\" data-end=\"3613\"\u003e\n\u003ctd data-start=\"3565\" data-end=\"3580\" data-col-size=\"sm\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd data-start=\"3580\" data-end=\"3613\" data-col-size=\"md\"\u003eDC Adaptor, AC 220V \/ 50–60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3614\" data-end=\"3657\"\u003e\n\u003ctd data-start=\"3614\" data-end=\"3635\" data-col-size=\"sm\"\u003eDimensions (L×W×H)\u003c\/td\u003e\n\u003ctd data-start=\"3635\" data-end=\"3657\" data-col-size=\"md\"\u003e310 × 255 × 190 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3658\" data-end=\"3675\"\u003e\n\u003ctd data-start=\"3658\" data-end=\"3667\" data-col-size=\"sm\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-start=\"3667\" data-end=\"3675\" data-col-size=\"md\"\u003e2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 data-start=\"3677\" data-end=\"3692\"\u003eApplications\u003c\/h3\u003e\n\u003cp data-start=\"3694\" data-end=\"3951\"\u003eIon concentration analysis\u003cbr data-start=\"3720\" data-end=\"3723\"\u003eWater quality and environmental testing\u003cbr data-start=\"3762\" data-end=\"3765\"\u003eChemical and pharmaceutical laboratories\u003cbr data-start=\"3805\" data-end=\"3808\"\u003eSwimming pool and wastewater analysis\u003cbr data-start=\"3845\" data-end=\"3848\"\u003eEducational and research institutions\u003cbr data-start=\"3885\" data-end=\"3888\"\u003eFood and beverage testing\u003cbr data-start=\"3913\" data-end=\"3916\"\u003eIndustrial electrochemical analysis\u003c\/p\u003e","brand":"Labman","offers":[{"title":"Default Title","offer_id":49968495231213,"sku":null,"price":50000.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5672\/6765\/files\/LMION40.jpg?v=1778961731","url":"https:\/\/www.biotronscientific.com\/products\/benchtop-ion-ph-mv-temperature-meter-for-laboratory-analysis","provider":"BIOTRON","version":"1.0","type":"link"}