{"product_id":"autosampler-for-gas-chromatography-asgc22-0-1-250-µl-22-vial-tray","title":"Autosampler for Gas Chromatography ASGC22 (0.1–250 µL, 22 Vial Tray)","description":"\u003cp data-start=\"281\" data-end=\"870\"\u003eAutosampler ASGC22 is designed to automate sample injection in gas chromatography systems, improving precision, repeatability and workflow efficiency. It enables unattended operation with programmable injection sequences, ensuring consistent injection volumes and reduced manual error. The system features a multi-position vial tray, flexible injection modes and adjustable speed control for accurate sample handling. With touchscreen interface, barcode support and communication compatibility, it integrates seamlessly with GC systems for routine and high-throughput analytical workflows.\u003c\/p\u003e\n\u003ch3 data-start=\"872\" data-end=\"889\"\u003eKey Features\u003c\/h3\u003e\n\u003cp data-start=\"890\" data-end=\"1530\"\u003eAutomated sample injection for improved reproducibility\u003cbr data-start=\"945\" data-end=\"948\"\u003eInjection volume range from 0.1 µL to 250 µL\u003cbr data-start=\"992\" data-end=\"995\"\u003eMulti-position sample tray for high-throughput operation\u003cbr data-start=\"1051\" data-end=\"1054\"\u003eProgrammable injection sequences with multiple methods\u003cbr data-start=\"1108\" data-end=\"1111\"\u003eAdjustable needle speed and injection modes\u003cbr data-start=\"1154\" data-end=\"1157\"\u003eHigh precision syringe control for accurate volume delivery\u003cbr data-start=\"1216\" data-end=\"1219\"\u003eTouchscreen interface for easy operation and monitoring\u003cbr data-start=\"1274\" data-end=\"1277\"\u003eSupports barcode scanning and sample tracking\u003cbr data-start=\"1322\" data-end=\"1325\"\u003eContinuous and normal injection modes for flexibility\u003cbr data-start=\"1378\" data-end=\"1381\"\u003eLow carryover design with multiple needle cleaning cycles\u003cbr data-start=\"1438\" data-end=\"1441\"\u003eCompatible with GC software control systems\u003cbr data-start=\"1484\" data-end=\"1487\"\u003eSupports long unattended operation cycles\u003c\/p\u003e\n\u003ch3 data-start=\"1532\" data-end=\"1561\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"1562\" data-end=\"2425\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"1562\" data-end=\"1591\"\u003e\n\u003ctr data-start=\"1562\" data-end=\"1591\"\u003e\n\u003cth data-start=\"1562\" data-end=\"1574\" data-col-size=\"sm\" class=\"\"\u003eParameter\u003c\/th\u003e\n\u003cth data-start=\"1574\" data-end=\"1591\" data-col-size=\"md\" class=\"\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"1602\" data-end=\"2425\"\u003e\n\u003ctr data-start=\"1602\" data-end=\"1637\"\u003e\n\u003ctd data-start=\"1602\" data-end=\"1619\" data-col-size=\"sm\"\u003eEquipment Type\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"1619\" data-end=\"1637\"\u003eGC Autosampler\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1638\" data-end=\"1656\"\u003e\n\u003ctd data-start=\"1638\" data-end=\"1646\" data-col-size=\"sm\"\u003eModel\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"1646\" data-end=\"1656\"\u003eASGC22\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1657\" data-end=\"1701\"\u003e\n\u003ctd data-start=\"1657\" data-end=\"1682\" data-col-size=\"sm\"\u003eInjection Volume Range\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"1682\" data-end=\"1701\"\u003e0.1 µL – 250 µL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1702\" data-end=\"1758\"\u003e\n\u003ctd data-start=\"1702\" data-end=\"1720\" data-col-size=\"sm\"\u003eSyringe Options\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"1720\" data-end=\"1758\"\u003e1, 5, 10, 25, 50, 100, 250, 500 µL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1759\" data-end=\"1798\"\u003e\n\u003ctd data-start=\"1759\" data-end=\"1782\" data-col-size=\"sm\"\u003eSample Tray Capacity\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"1782\" data-end=\"1798\"\u003e22 positions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1799\" data-end=\"1820\"\u003e\n\u003ctd data-start=\"1799\" data-end=\"1814\" data-col-size=\"sm\"\u003eSample Vials\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"1814\" data-end=\"1820\"\u003e19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1821\" data-end=\"1842\"\u003e\n\u003ctd data-start=\"1821\" data-end=\"1837\" data-col-size=\"sm\"\u003eSolvent Vials\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"1837\" data-end=\"1842\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1843\" data-end=\"1861\"\u003e\n\u003ctd data-start=\"1843\" data-end=\"1856\" data-col-size=\"sm\"\u003eWaste Vial\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"1856\" data-end=\"1861\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1862\" data-end=\"1898\"\u003e\n\u003ctd data-start=\"1862\" data-end=\"1882\" data-col-size=\"sm\"\u003eInjection Repeats\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"1882\" data-end=\"1898\"\u003e1 – 99 times\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1899\" data-end=\"1929\"\u003e\n\u003ctd data-start=\"1899\" data-end=\"1918\" data-col-size=\"sm\"\u003eMaximum Interval\u003c\/td\u003e\n\u003ctd data-start=\"1918\" data-end=\"1929\" data-col-size=\"md\"\u003e999 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1930\" data-end=\"1950\"\u003e\n\u003ctd data-start=\"1930\" data-end=\"1940\" data-col-size=\"sm\"\u003eMethods\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"1940\" data-end=\"1950\"\u003e1 – 20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1951\" data-end=\"1994\"\u003e\n\u003ctd data-start=\"1951\" data-end=\"1976\" data-col-size=\"sm\"\u003eNeedle Cleaning Cycles\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"1976\" data-end=\"1994\"\u003eUp to 99 times\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1995\" data-end=\"2031\"\u003e\n\u003ctd data-start=\"1995\" data-end=\"2014\" data-col-size=\"sm\"\u003ePumping Interval\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2014\" data-end=\"2031\"\u003eUp to 5000 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2032\" data-end=\"2062\"\u003e\n\u003ctd data-start=\"2032\" data-end=\"2050\" data-col-size=\"sm\"\u003eViscosity Delay\u003c\/td\u003e\n\u003ctd data-start=\"2050\" data-end=\"2062\" data-col-size=\"md\"\u003e0 – 60 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2063\" data-end=\"2089\"\u003e\n\u003ctd data-start=\"2063\" data-end=\"2076\" data-col-size=\"sm\"\u003eDwell Time\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2076\" data-end=\"2089\"\u003e0 – 120 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2090\" data-end=\"2131\"\u003e\n\u003ctd data-start=\"2090\" data-end=\"2108\" data-col-size=\"sm\"\u003eInjection Modes\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2108\" data-end=\"2131\"\u003eNormal \/ Continuous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2132\" data-end=\"2177\"\u003e\n\u003ctd data-start=\"2132\" data-end=\"2147\" data-col-size=\"sm\"\u003eNeedle Speed\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2147\" data-end=\"2177\"\u003eFast \/ Slow \/ User-defined\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2178\" data-end=\"2216\"\u003e\n\u003ctd data-start=\"2178\" data-end=\"2193\" data-col-size=\"sm\"\u003eControl Mode\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2193\" data-end=\"2216\"\u003eGC software control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2217\" data-end=\"2253\"\u003e\n\u003ctd data-start=\"2217\" data-end=\"2232\" data-col-size=\"sm\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2232\" data-end=\"2253\"\u003eAC 220V, 50–60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2254\" data-end=\"2289\"\u003e\n\u003ctd data-start=\"2254\" data-end=\"2267\" data-col-size=\"sm\"\u003eDimensions\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2267\" data-end=\"2289\"\u003e620 × 325 × 280 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2290\" data-end=\"2315\"\u003e\n\u003ctd data-start=\"2290\" data-end=\"2299\" data-col-size=\"sm\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-start=\"2299\" data-end=\"2315\" data-col-size=\"md\"\u003eApprox. 6 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2316\" data-end=\"2363\"\u003e\n\u003ctd data-start=\"2316\" data-end=\"2330\" data-col-size=\"sm\"\u003eApplication\u003c\/td\u003e\n\u003ctd data-start=\"2330\" data-end=\"2363\" data-col-size=\"md\"\u003eAutomated GC sample injection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2364\" data-end=\"2425\"\u003e\n\u003ctd data-start=\"2364\" data-end=\"2372\" data-col-size=\"sm\"\u003eUsage\u003c\/td\u003e\n\u003ctd data-start=\"2372\" data-end=\"2425\" data-col-size=\"md\"\u003eAnalytical laboratories, chromatography workflows\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Labman","offers":[{"title":"Default Title","offer_id":49822367056109,"sku":null,"price":450000.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5672\/6765\/files\/ASGC22.jpg?v=1776974426","url":"https:\/\/www.biotronscientific.com\/products\/autosampler-for-gas-chromatography-asgc22-0-1-250-%c2%b5l-22-vial-tray","provider":"BIOTRON","version":"1.0","type":"link"}