{"product_id":"antistatic-ionizer-iz540e-iz540a-static-neutralization-for-analytical-balances","title":"Antistatic Ionizer IZ540E \u0026 IZ540A (Static Neutralization for Analytical Balances)","description":"\u003cp data-start=\"287\" data-end=\"636\"\u003eAntistatic Ionizer IZ540E and IZ540A are precision laboratory devices designed to eliminate electrostatic interference during highly sensitive weighing operations. By neutralizing excess electric charges surrounding samples, weighing containers, and balance chambers, the ionizers improve weighing stability, repeatability, and measurement accuracy.\u003c\/p\u003e\n\u003cp data-start=\"638\" data-end=\"945\"\u003eElectrostatic charges generated on powders, plastics, glass containers, and lightweight materials can affect weighing performance and lead to inconsistent results. The IZ540 series reduces these effects by balancing ion concentration around the weighing environment and improving sample handling conditions.\u003c\/p\u003e\n\u003cp data-start=\"947\" data-end=\"1229\"\u003eIZ540E is designed as an external ionization device, while IZ540A integrates directly with the balance windshield assembly for space-efficient operation. Both models support dual operating modes including continuous operation and timed ionization cycles for flexible laboratory use.\u003c\/p\u003e\n\u003cp data-start=\"1231\" data-end=\"1439\"\u003eThe system delivers rapid charge discharge performance with controlled ozone generation and optimized airflow, making it suitable for analytical balances, micro balances, and semi-micro weighing applications.\u003c\/p\u003e\n\u003cp data-start=\"1441\" data-end=\"1643\"\u003eDesigned for research laboratories, pharmaceutical environments, and precision weighing workflows, the IZ540 series improves measurement reliability where static-sensitive samples are routinely handled.\u003c\/p\u003e\n\u003ch3 data-start=\"1645\" data-end=\"1660\"\u003eKey Features\u003c\/h3\u003e\n\u003cp data-start=\"1662\" data-end=\"2182\"\u003eNeutralizes electrostatic charges during weighing\u003cbr data-start=\"1711\" data-end=\"1714\"\u003eImproves weighing precision and repeatability\u003cbr data-start=\"1759\" data-end=\"1762\"\u003eSuitable for analytical and micro balances\u003cbr data-start=\"1804\" data-end=\"1807\"\u003eDual operating modes: continuous and timed operation\u003cbr data-start=\"1859\" data-end=\"1862\"\u003eFast static discharge performance\u003cbr data-start=\"1895\" data-end=\"1898\"\u003eSupports weighing of static-sensitive powder samples\u003cbr data-start=\"1950\" data-end=\"1953\"\u003eReduces electrostatic interference\u003cbr data-start=\"1987\" data-end=\"1990\"\u003eLow ozone generation design\u003cbr data-start=\"2017\" data-end=\"2020\"\u003eCompact and lightweight construction\u003cbr data-start=\"2056\" data-end=\"2059\"\u003eExternal and integrated installation options\u003cbr data-start=\"2103\" data-end=\"2106\"\u003eSimple push-button operation\u003cbr data-start=\"2134\" data-end=\"2137\"\u003eOptimized airflow for stable ion distribution\u003c\/p\u003e\n\u003ch3 data-start=\"2184\" data-end=\"2211\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"2213\" data-end=\"2836\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"2213\" data-end=\"2244\"\u003e\n\u003ctr data-start=\"2213\" data-end=\"2244\"\u003e\n\u003cth data-start=\"2213\" data-end=\"2225\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth data-start=\"2225\" data-end=\"2234\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eIZ540E\u003c\/th\u003e\n\u003cth data-start=\"2234\" data-end=\"2244\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eIZ540A\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"2259\" data-end=\"2836\"\u003e\n\u003ctr data-start=\"2259\" data-end=\"2319\"\u003e\n\u003ctd data-start=\"2259\" data-end=\"2273\" data-col-size=\"sm\"\u003eDesign Type\u003c\/td\u003e\n\u003ctd data-start=\"2273\" data-end=\"2291\" data-col-size=\"sm\"\u003eExternal Device\u003c\/td\u003e\n\u003ctd data-start=\"2291\" data-end=\"2319\" data-col-size=\"sm\"\u003eAttached with Windshield\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2320\" data-end=\"2396\"\u003e\n\u003ctd data-start=\"2320\" data-end=\"2337\" data-col-size=\"sm\"\u003eOperation Mode\u003c\/td\u003e\n\u003ctd data-start=\"2337\" data-end=\"2366\" data-col-size=\"sm\"\u003eContinuous \/ 2-minute Mode\u003c\/td\u003e\n\u003ctd data-start=\"2366\" data-end=\"2396\" data-col-size=\"sm\"\u003eContinuous \/ 2-minute Mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2397\" data-end=\"2463\"\u003e\n\u003ctd data-start=\"2397\" data-end=\"2426\" data-col-size=\"sm\"\u003eDistance Sample–Ion Source\u003c\/td\u003e\n\u003ctd data-start=\"2426\" data-end=\"2444\" data-col-size=\"sm\"\u003eApprox. 5–40 cm\u003c\/td\u003e\n\u003ctd data-start=\"2444\" data-end=\"2463\" data-col-size=\"sm\"\u003eApprox. 5–40 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2464\" data-end=\"2560\"\u003e\n\u003ctd data-start=\"2464\" data-end=\"2481\" data-col-size=\"sm\"\u003eDischarge Time\u003c\/td\u003e\n\u003ctd data-start=\"2481\" data-end=\"2520\" data-col-size=\"sm\"\u003e9s\/5cm, 13s\/10cm, 100s\/40cm (Fan ON)\u003c\/td\u003e\n\u003ctd data-start=\"2520\" data-end=\"2560\" data-col-size=\"sm\"\u003e9s\/5cm, 13s\/10cm, 100s\/40cm (Fan ON)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2561\" data-end=\"2610\"\u003e\n\u003ctd data-start=\"2561\" data-end=\"2583\" data-col-size=\"sm\"\u003eOzone Concentration\u003c\/td\u003e\n\u003ctd data-start=\"2583\" data-end=\"2596\" data-col-size=\"sm\"\u003e0–0.05 ppm\u003c\/td\u003e\n\u003ctd data-start=\"2596\" data-end=\"2610\" data-col-size=\"sm\"\u003e0–0.05 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2611\" data-end=\"2663\"\u003e\n\u003ctd data-start=\"2611\" data-end=\"2632\" data-col-size=\"sm\"\u003eMaximum Air Volume\u003c\/td\u003e\n\u003ctd data-start=\"2632\" data-end=\"2647\" data-col-size=\"sm\"\u003e0.06 cm³\/min\u003c\/td\u003e\n\u003ctd data-start=\"2647\" data-end=\"2663\" data-col-size=\"sm\"\u003e0.06 cm³\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2664\" data-end=\"2711\"\u003e\n\u003ctd data-start=\"2664\" data-end=\"2686\" data-col-size=\"sm\"\u003eAmbient Temperature\u003c\/td\u003e\n\u003ctd data-start=\"2686\" data-end=\"2698\" data-col-size=\"sm\"\u003e10°C–40°C\u003c\/td\u003e\n\u003ctd data-start=\"2698\" data-end=\"2711\" data-col-size=\"sm\"\u003e10°C–40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2712\" data-end=\"2746\"\u003e\n\u003ctd data-start=\"2712\" data-end=\"2727\" data-col-size=\"sm\"\u003eAir Humidity\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2727\" data-end=\"2736\"\u003e20–80%\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2736\" data-end=\"2746\"\u003e20–80%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2747\" data-end=\"2809\"\u003e\n\u003ctd data-start=\"2747\" data-end=\"2762\" data-col-size=\"sm\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd data-start=\"2762\" data-end=\"2785\" data-col-size=\"sm\"\u003eAC 100–240V, 50\/60Hz\u003c\/td\u003e\n\u003ctd data-start=\"2785\" data-end=\"2809\" data-col-size=\"sm\"\u003eAC 100–240V, 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2810\" data-end=\"2836\"\u003e\n\u003ctd data-start=\"2810\" data-end=\"2819\" data-col-size=\"sm\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-start=\"2819\" data-end=\"2827\" data-col-size=\"sm\"\u003e300 g\u003c\/td\u003e\n\u003ctd data-start=\"2827\" data-end=\"2836\" data-col-size=\"sm\"\u003e300 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 data-start=\"2838\" data-end=\"2853\"\u003eApplications\u003c\/h3\u003e\n\u003cp data-start=\"2855\" data-end=\"3127\"\u003eMicro and semi-micro balance weighing\u003cbr data-start=\"2892\" data-end=\"2895\"\u003eAnalytical laboratory measurements\u003cbr data-start=\"2929\" data-end=\"2932\"\u003ePharmaceutical weighing applications\u003cbr data-start=\"2968\" data-end=\"2971\"\u003eStatic-sensitive powder handling\u003cbr data-start=\"3003\" data-end=\"3006\"\u003ePrecision formulation workflows\u003cbr data-start=\"3037\" data-end=\"3040\"\u003eResearch and quality control laboratories\u003cbr data-start=\"3081\" data-end=\"3084\"\u003eHigh-accuracy mass measurement environments\u003c\/p\u003e","brand":"Wensar","offers":[{"title":"IZ540E","offer_id":50011065680109,"sku":null,"price":0.0,"currency_code":"INR","in_stock":true},{"title":"IZ540A","offer_id":50011065712877,"sku":null,"price":0.0,"currency_code":"INR","in_stock":true}],"url":"https:\/\/www.biotronscientific.com\/products\/antistatic-ionizer-iz540e-iz540a-static-neutralization-for-analytical-balances","provider":"BIOTRON","version":"1.0","type":"link"}