{"product_id":"analytical-balance-tab1t-220g-capacity-0-1mg-readability-5-touch-screen-internal-calibration","title":"Analytical Balance TAB1T (220g Capacity, 0.1mg Readability, 5\" Touch Screen \u0026 Internal Calibration)","description":"\u003cp data-start=\"458\" data-end=\"789\"\u003eThe TAB1T Analytical Balance is a high-precision weighing instrument designed for analytical laboratories, pharmaceutical environments, research facilities and precision industrial applications. Built with Electro Magnetic Force Compensation (EMFC) technology, it delivers stable and highly repeatable weighing performance.\u003c\/p\u003e\n\u003cp data-start=\"791\" data-end=\"1077\"\u003eWith a 220 g capacity and 0.1 mg readability, TAB1T enables accurate measurement for analytical testing, formulation, density determination and quality control operations. The integrated 5-inch touch screen display provides intuitive operation and faster workflow execution.\u003c\/p\u003e\n\u003cp data-start=\"1079\" data-end=\"1321\"\u003eThe balance includes internal calibration, density determination, percentage weighing, piece counting, underhook weighing and multiple weighing unit support. RS232 communication enables convenient data transfer and laboratory integration.\u003c\/p\u003e\n\u003cp data-start=\"1323\" data-end=\"1473\"\u003eTAB1T is also suitable for gold, jewellery, precious metal and gemstone weighing applications where high precision and repeatability are required.\u003c\/p\u003e\n\u003ch3 data-start=\"1480\" data-end=\"1497\"\u003eKey Features\u003c\/h3\u003e\n\u003cp data-start=\"1499\" data-end=\"1880\"\u003eElectro Magnetic Force Compensation (EMFC) technology\u003cbr data-start=\"1552\" data-end=\"1555\"\u003e5-inch touch screen display\u003cbr data-start=\"1582\" data-end=\"1585\"\u003ePercentage weighing function\u003cbr data-start=\"1613\" data-end=\"1616\"\u003eMultiple weighing units\u003cbr data-start=\"1639\" data-end=\"1642\"\u003eDensity determination function\u003cbr data-start=\"1672\" data-end=\"1675\"\u003eRS232C communication interface\u003cbr data-start=\"1705\" data-end=\"1708\"\u003ePiece counting function\u003cbr data-start=\"1731\" data-end=\"1734\"\u003eUnderhook weighing\u003cbr data-start=\"1752\" data-end=\"1755\"\u003eInternal calibration with built-in weight\u003cbr data-start=\"1796\" data-end=\"1799\"\u003eDate and time function\u003cbr data-start=\"1821\" data-end=\"1824\"\u003eFast weighing response\u003cbr data-start=\"1846\" data-end=\"1849\"\u003eStable analytical performance\u003c\/p\u003e\n\u003ch3 data-start=\"1887\" data-end=\"1916\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"1918\" data-end=\"2683\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"1918\" data-end=\"1947\"\u003e\n\u003ctr data-start=\"1918\" data-end=\"1947\"\u003e\n\u003cth data-start=\"1918\" data-end=\"1930\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth data-start=\"1930\" data-end=\"1947\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"1958\" data-end=\"2683\"\u003e\n\u003ctr data-start=\"1958\" data-end=\"1978\"\u003e\n\u003ctd data-start=\"1958\" data-end=\"1969\" data-col-size=\"sm\"\u003eCapacity\u003c\/td\u003e\n\u003ctd data-start=\"1969\" data-end=\"1978\" data-col-size=\"sm\"\u003e220 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1979\" data-end=\"2007\"\u003e\n\u003ctd data-start=\"1979\" data-end=\"1997\" data-col-size=\"sm\"\u003eReadability (d)\u003c\/td\u003e\n\u003ctd data-start=\"1997\" data-end=\"2007\" data-col-size=\"sm\"\u003e0.1 mg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2008\" data-end=\"2034\"\u003e\n\u003ctd data-start=\"2008\" data-end=\"2024\" data-col-size=\"sm\"\u003eRepeatability\u003c\/td\u003e\n\u003ctd data-start=\"2024\" data-end=\"2034\" data-col-size=\"sm\"\u003e0.2 mg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2035\" data-end=\"2061\"\u003e\n\u003ctd data-start=\"2035\" data-end=\"2051\" data-col-size=\"sm\"\u003eLinearity (±)\u003c\/td\u003e\n\u003ctd data-start=\"2051\" data-end=\"2061\" data-col-size=\"sm\"\u003e0.4 mg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2062\" data-end=\"2090\"\u003e\n\u003ctd data-start=\"2062\" data-end=\"2081\" data-col-size=\"sm\"\u003eMinimum Capacity\u003c\/td\u003e\n\u003ctd data-start=\"2081\" data-end=\"2090\" data-col-size=\"sm\"\u003e10 mg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2091\" data-end=\"2133\"\u003e\n\u003ctd data-start=\"2091\" data-end=\"2125\" data-col-size=\"sm\"\u003eVerification Scale Interval (e)\u003c\/td\u003e\n\u003ctd data-start=\"2125\" data-end=\"2133\" data-col-size=\"sm\"\u003e1 mg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2134\" data-end=\"2172\"\u003e\n\u003ctd data-start=\"2134\" data-end=\"2148\" data-col-size=\"sm\"\u003eCalibration\u003c\/td\u003e\n\u003ctd data-start=\"2148\" data-end=\"2172\" data-col-size=\"sm\"\u003eInternal Calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2173\" data-end=\"2192\"\u003e\n\u003ctd data-start=\"2173\" data-end=\"2181\" data-col-size=\"sm\"\u003eClass\u003c\/td\u003e\n\u003ctd data-start=\"2181\" data-end=\"2192\" data-col-size=\"sm\"\u003eClass I\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2193\" data-end=\"2226\"\u003e\n\u003ctd data-start=\"2193\" data-end=\"2203\" data-col-size=\"sm\"\u003eDisplay\u003c\/td\u003e\n\u003ctd data-start=\"2203\" data-end=\"2226\" data-col-size=\"sm\"\u003e5-inch Touch Screen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2227\" data-end=\"2254\"\u003e\n\u003ctd data-start=\"2227\" data-end=\"2243\" data-col-size=\"sm\"\u003eResponse Time\u003c\/td\u003e\n\u003ctd data-start=\"2243\" data-end=\"2254\" data-col-size=\"sm\"\u003e3–5 sec\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2255\" data-end=\"2277\"\u003e\n\u003ctd data-start=\"2255\" data-end=\"2266\" data-col-size=\"sm\"\u003ePan Size\u003c\/td\u003e\n\u003ctd data-start=\"2266\" data-end=\"2277\" data-col-size=\"sm\"\u003e80 mm Ø\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2278\" data-end=\"2299\"\u003e\n\u003ctd data-start=\"2278\" data-end=\"2291\" data-col-size=\"sm\"\u003eTare Range\u003c\/td\u003e\n\u003ctd data-start=\"2291\" data-end=\"2299\" data-col-size=\"sm\"\u003eFull\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2300\" data-end=\"2340\"\u003e\n\u003ctd data-start=\"2300\" data-end=\"2324\" data-col-size=\"sm\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd data-start=\"2324\" data-end=\"2340\" data-col-size=\"sm\"\u003e15°C to 30°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2341\" data-end=\"2373\"\u003e\n\u003ctd data-start=\"2341\" data-end=\"2361\" data-col-size=\"sm\"\u003eSensitivity Drift\u003c\/td\u003e\n\u003ctd data-start=\"2361\" data-end=\"2373\" data-col-size=\"sm\"\u003e2 ppm\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2374\" data-end=\"2406\"\u003e\n\u003ctd data-start=\"2374\" data-end=\"2393\" data-col-size=\"sm\"\u003eDensity Function\u003c\/td\u003e\n\u003ctd data-start=\"2393\" data-end=\"2406\" data-col-size=\"sm\"\u003eAvailable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2407\" data-end=\"2426\"\u003e\n\u003ctd data-start=\"2407\" data-end=\"2419\" data-col-size=\"sm\"\u003eKey Sound\u003c\/td\u003e\n\u003ctd data-start=\"2419\" data-end=\"2426\" data-col-size=\"sm\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2427\" data-end=\"2468\"\u003e\n\u003ctd data-start=\"2427\" data-end=\"2446\" data-col-size=\"sm\"\u003eWeighing Chamber\u003c\/td\u003e\n\u003ctd data-start=\"2446\" data-end=\"2468\" data-col-size=\"sm\"\u003e240 × 190 × 265 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2469\" data-end=\"2494\"\u003e\n\u003ctd data-start=\"2469\" data-end=\"2477\" data-col-size=\"sm\"\u003eUnits\u003c\/td\u003e\n\u003ctd data-start=\"2477\" data-end=\"2494\" data-col-size=\"sm\"\u003eg, mg, ct, oz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2495\" data-end=\"2541\"\u003e\n\u003ctd data-start=\"2495\" data-end=\"2515\" data-col-size=\"sm\"\u003eBaud Rate Options\u003c\/td\u003e\n\u003ctd data-start=\"2515\" data-end=\"2541\" data-col-size=\"sm\"\u003e1200, 2400, 4800, 9600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2542\" data-end=\"2564\"\u003e\n\u003ctd data-start=\"2542\" data-end=\"2554\" data-col-size=\"sm\"\u003eInterface\u003c\/td\u003e\n\u003ctd data-start=\"2554\" data-end=\"2564\" data-col-size=\"sm\"\u003eRS232C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2565\" data-end=\"2602\"\u003e\n\u003ctd data-start=\"2565\" data-end=\"2580\" data-col-size=\"sm\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd data-start=\"2580\" data-end=\"2602\" data-col-size=\"sm\"\u003eAC 220V \/ 50–60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2603\" data-end=\"2658\"\u003e\n\u003ctd data-start=\"2603\" data-end=\"2636\" data-col-size=\"sm\"\u003ePacking Dimensions (L × W × H)\u003c\/td\u003e\n\u003ctd data-start=\"2636\" data-end=\"2658\" data-col-size=\"sm\"\u003e510 × 370 × 515 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2659\" data-end=\"2683\"\u003e\n\u003ctd data-start=\"2659\" data-end=\"2674\" data-col-size=\"sm\"\u003eGross Weight\u003c\/td\u003e\n\u003ctd data-start=\"2674\" data-end=\"2683\" data-col-size=\"sm\"\u003e10 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 data-start=\"2690\" data-end=\"2707\"\u003eApplications\u003c\/h3\u003e\n\u003cp data-start=\"2709\" data-end=\"3043\"\u003eAnalytical laboratories\u003cbr data-start=\"2732\" data-end=\"2735\"\u003ePharmaceutical laboratories\u003cbr data-start=\"2762\" data-end=\"2765\"\u003eResearch laboratories\u003cbr data-start=\"2786\" data-end=\"2789\"\u003eChemical laboratories\u003cbr data-start=\"2810\" data-end=\"2813\"\u003eQuality control laboratories\u003cbr data-start=\"2841\" data-end=\"2844\"\u003eDensity determination applications\u003cbr data-start=\"2878\" data-end=\"2881\"\u003ePrecision sample preparation\u003cbr data-start=\"2909\" data-end=\"2912\"\u003eGold industry\u003cbr data-start=\"2925\" data-end=\"2928\"\u003eJewellery industry\u003cbr data-start=\"2946\" data-end=\"2949\"\u003ePrecious metal weighing\u003cbr data-start=\"2972\" data-end=\"2975\"\u003eGemstone testing laboratories\u003c\/p\u003e","brand":"Wensar","offers":[{"title":"Default Title","offer_id":50011201896685,"sku":null,"price":0.0,"currency_code":"INR","in_stock":true}],"url":"https:\/\/www.biotronscientific.com\/products\/analytical-balance-tab1t-220g-capacity-0-1mg-readability-5-touch-screen-internal-calibration","provider":"BIOTRON","version":"1.0","type":"link"}