{"title":"Water Quality \u0026 Analytical Meters","description":null,"products":[{"product_id":"visual-colorimeter-for-colour-scale-measurement-transmittance-reflectance","title":"Visual Colorimeter for Colour Scale Measurement LMCR80F (Transmittance \u0026 Reflectance)","description":"\u003cp data-start=\"289\" data-end=\"624\"\u003eVisual Colorimeter LMCR80F is designed for visual colour measurement and colour matching analysis using internationally accepted colour scale units. The instrument enables accurate determination of colour intensity and comparison for liquids, semi-solids, powders, and transparent samples across industrial and laboratory applications.\u003c\/p\u003e\n\u003cp data-start=\"626\" data-end=\"893\"\u003eThe system operates on both transmittance and reflectance measurement principles, allowing flexible analysis of different sample types. It provides direct visual comparison using standard international colour scales for reliable colour grading and quality assessment.\u003c\/p\u003e\n\u003cp data-start=\"895\" data-end=\"1214\"\u003eEquipped with an adjustable viewing system and daylight-approximate illumination, the instrument ensures consistent observation conditions and improved colour perception accuracy. The replaceable sample chamber liner and replaceable incandescent light source support long-term laboratory operation and easy maintenance.\u003c\/p\u003e\n\u003cp data-start=\"1216\" data-end=\"1414\"\u003eThe LMCR80F is suitable for colour analysis in grease, paints, plastics, jams, textiles, food products, chemicals, pharmaceuticals, and related industries requiring routine visual colour evaluation.\u003c\/p\u003e\n\u003ch3 data-start=\"1416\" data-end=\"1431\"\u003eKey Features\u003c\/h3\u003e\n\u003cp data-start=\"1433\" data-end=\"1907\"\u003eVisual colour measurement using international colour scale units\u003cbr data-start=\"1497\" data-end=\"1500\"\u003eTransmittance and reflectance measurement modes\u003cbr data-start=\"1547\" data-end=\"1550\"\u003eAdjustable viewing system for accurate observation\u003cbr data-start=\"1600\" data-end=\"1603\"\u003eDaylight-approximate illumination system\u003cbr data-start=\"1643\" data-end=\"1646\"\u003eReplaceable incandescent light source\u003cbr data-start=\"1683\" data-end=\"1686\"\u003eReplaceable sample chamber liner\u003cbr data-start=\"1718\" data-end=\"1721\"\u003eSimple and easy laboratory operation\u003cbr data-start=\"1757\" data-end=\"1760\"\u003eSuitable for liquid, powder, and semi-solid samples\u003cbr data-start=\"1811\" data-end=\"1814\"\u003eDesigned for colour matching and quality control applications\u003cbr data-start=\"1875\" data-end=\"1878\"\u003eCompact benchtop construction\u003c\/p\u003e\n\u003ch3 data-start=\"1909\" data-end=\"1936\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"1938\" data-end=\"2648\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"1938\" data-end=\"1967\"\u003e\n\u003ctr data-start=\"1938\" data-end=\"1967\"\u003e\n\u003cth data-start=\"1938\" data-end=\"1950\" data-col-size=\"sm\" class=\"\"\u003eParameter\u003c\/th\u003e\n\u003cth data-start=\"1950\" data-end=\"1967\" data-col-size=\"md\" class=\"\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"1982\" data-end=\"2648\"\u003e\n\u003ctr data-start=\"2020\" data-end=\"2077\"\u003e\n\u003ctd data-start=\"2020\" data-end=\"2042\" data-col-size=\"sm\"\u003eMeasuring Principle\u003c\/td\u003e\n\u003ctd data-start=\"2042\" data-end=\"2077\" data-col-size=\"md\"\u003eVisual colour scale measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2078\" data-end=\"2116\"\u003e\n\u003ctd data-start=\"2078\" data-end=\"2086\" data-col-size=\"sm\"\u003eModes\u003c\/td\u003e\n\u003ctd data-start=\"2086\" data-end=\"2116\" data-col-size=\"md\"\u003eTransmittance, Reflectance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2117\" data-end=\"2202\"\u003e\n\u003ctd data-start=\"2117\" data-end=\"2137\" data-col-size=\"sm\"\u003eMeasurement Range\u003c\/td\u003e\n\u003ctd data-start=\"2137\" data-end=\"2202\" data-col-size=\"md\"\u003e0.1–79.9 Red, 0.1–79.9 Yellow, 0.1–49.9 Blue, 0.1–3.9 Neutral\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2203\" data-end=\"2241\"\u003e\n\u003ctd data-start=\"2203\" data-end=\"2216\" data-col-size=\"sm\"\u003eResolution\u003c\/td\u003e\n\u003ctd data-start=\"2216\" data-end=\"2241\" data-col-size=\"md\"\u003e0.1 colour scale unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2242\" data-end=\"2279\"\u003e\n\u003ctd data-start=\"2242\" data-end=\"2259\" data-col-size=\"sm\"\u003eViewing System\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2259\" data-end=\"2279\"\u003eFully Adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2280\" data-end=\"2316\"\u003e\n\u003ctd data-start=\"2280\" data-end=\"2295\" data-col-size=\"sm\"\u003eLight Source\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2295\" data-end=\"2316\"\u003eIncandescent Lamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2317\" data-end=\"2354\"\u003e\n\u003ctd data-start=\"2317\" data-end=\"2330\" data-col-size=\"sm\"\u003eIlluminant\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2330\" data-end=\"2354\"\u003eApproximate Daylight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2355\" data-end=\"2385\"\u003e\n\u003ctd data-start=\"2355\" data-end=\"2369\" data-col-size=\"sm\"\u003ePath Length\u003c\/td\u003e\n\u003ctd data-start=\"2369\" data-end=\"2385\" data-col-size=\"md\"\u003eUp to 180 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2386\" data-end=\"2432\"\u003e\n\u003ctd data-start=\"2386\" data-end=\"2424\" data-col-size=\"sm\"\u003eDiffuse Reflectivity of White Plate\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2424\" data-end=\"2432\"\u003e\u0026gt;80%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2433\" data-end=\"2467\"\u003e\n\u003ctd data-start=\"2433\" data-end=\"2459\" data-col-size=\"sm\"\u003eMagnifier Amplification\u003c\/td\u003e\n\u003ctd data-start=\"2459\" data-end=\"2467\" data-col-size=\"md\"\u003e1.9×\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2468\" data-end=\"2548\"\u003e\n\u003ctd data-start=\"2468\" data-end=\"2502\" data-col-size=\"sm\"\u003eColorimetric Cuvette Dimensions\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2502\" data-end=\"2548\"\u003e10×20×40 mm, 25.4×20×40 mm, 133.4×20×40 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2549\" data-end=\"2585\"\u003e\n\u003ctd data-start=\"2549\" data-end=\"2564\" data-col-size=\"sm\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2564\" data-end=\"2585\"\u003eAC 220V \/ 50–60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2586\" data-end=\"2629\"\u003e\n\u003ctd data-start=\"2586\" data-end=\"2607\" data-col-size=\"sm\"\u003eDimensions (L×W×H)\u003c\/td\u003e\n\u003ctd data-start=\"2607\" data-end=\"2629\" data-col-size=\"md\"\u003e620 × 450 × 310 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2630\" data-end=\"2648\"\u003e\n\u003ctd data-start=\"2630\" data-end=\"2639\" data-col-size=\"sm\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2639\" data-end=\"2648\"\u003e10 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 data-start=\"2650\" data-end=\"2665\"\u003eApplications\u003c\/h3\u003e\n\u003cp data-start=\"2667\" data-end=\"2946\"\u003eGrease and lubricant colour testing\u003cbr data-start=\"2702\" data-end=\"2705\"\u003ePaint and coating colour analysis\u003cbr data-start=\"2738\" data-end=\"2741\"\u003ePlastic and polymer colour matching\u003cbr data-start=\"2776\" data-end=\"2779\"\u003eFood and beverage colour evaluation\u003cbr data-start=\"2814\" data-end=\"2817\"\u003eTextile and fabric colour assessment\u003cbr data-start=\"2853\" data-end=\"2856\"\u003eChemical and pharmaceutical quality control\u003cbr data-start=\"2899\" data-end=\"2902\"\u003eRoutine industrial colour comparison testing\u003c\/p\u003e","brand":"Labman","offers":[{"title":"Default Title","offer_id":49968451420397,"sku":null,"price":90000.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5672\/6765\/files\/LMCR80F.jpg?v=1778926751"},{"product_id":"economic-ph-meter-with-automatic-temperature-compensation","title":"Economic pH Meter with Automatic Temperature Compensation LMPH9","description":"\u003cp data-start=\"266\" data-end=\"573\"\u003eEconomic pH Meter LMPH9 is designed for accurate and reliable pH measurement in laboratories, educational institutes, water testing facilities, and industrial quality control applications. The instrument combines user-friendly operation with stable analytical performance for routine pH and mV measurements.\u003c\/p\u003e\n\u003cp data-start=\"575\" data-end=\"819\"\u003eThe system features automatic temperature compensation to improve measurement accuracy across varying sample temperatures. A large LCD display simultaneously shows pH and temperature values, providing clear real-time monitoring during analysis.\u003c\/p\u003e\n\u003cp data-start=\"821\" data-end=\"1070\"\u003eThe instrument supports up to three-point calibration using standard USA buffer solutions, enabling improved accuracy and calibration flexibility. Integrated memory storage allows storage of up to 25 measurement records for convenient data handling.\u003c\/p\u003e\n\u003cp data-start=\"1072\" data-end=\"1329\"\u003eLMPH9 includes mV measurement capability, automatic slope display after calibration, and a BNC connector for compatibility with standard pH electrodes. The compact benchtop design and supplied electrode stand make it suitable for daily laboratory operation.\u003c\/p\u003e\n\u003cp data-start=\"1331\" data-end=\"1491\"\u003eThe instrument is widely used for water analysis, educational laboratories, chemical testing, environmental monitoring, and routine pH measurement applications.\u003c\/p\u003e\n\u003ch3 data-start=\"1493\" data-end=\"1508\"\u003eKey Features\u003c\/h3\u003e\n\u003cp data-start=\"1510\" data-end=\"1918\"\u003e0–14 pH measurement range\u003cbr data-start=\"1535\" data-end=\"1538\"\u003eAutomatic temperature compensation\u003cbr data-start=\"1572\" data-end=\"1575\"\u003eSimultaneous pH and temperature display\u003cbr data-start=\"1614\" data-end=\"1617\"\u003eLarge LCD screen with backlight\u003cbr data-start=\"1648\" data-end=\"1651\"\u003eUp to 3-point calibration support\u003cbr data-start=\"1684\" data-end=\"1687\"\u003eMemory storage up to 25 records\u003cbr data-start=\"1718\" data-end=\"1721\"\u003emV measurement capability\u003cbr data-start=\"1746\" data-end=\"1749\"\u003eAutomatic slope display after calibration\u003cbr data-start=\"1790\" data-end=\"1793\"\u003eCompatible with standard BNC electrodes\u003cbr data-start=\"1832\" data-end=\"1835\"\u003eCompact and easy-to-use laboratory design\u003cbr data-start=\"1876\" data-end=\"1879\"\u003eSuitable for routine laboratory testing\u003c\/p\u003e\n\u003ch3 data-start=\"1920\" data-end=\"1947\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"1949\" data-end=\"2612\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"1949\" data-end=\"1978\"\u003e\n\u003ctr data-start=\"1949\" data-end=\"1978\"\u003e\n\u003cth data-start=\"1949\" data-end=\"1961\" data-col-size=\"sm\" class=\"\"\u003eParameter\u003c\/th\u003e\n\u003cth data-start=\"1961\" data-end=\"1978\" data-col-size=\"sm\" class=\"\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"1993\" data-end=\"2612\"\u003e\n\u003ctr data-start=\"2029\" data-end=\"2057\"\u003e\n\u003ctd data-start=\"2029\" data-end=\"2040\" data-col-size=\"sm\"\u003epH Range\u003c\/td\u003e\n\u003ctd data-start=\"2040\" data-end=\"2057\" data-col-size=\"sm\"\u003e0 to 14.00 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2058\" data-end=\"2094\"\u003e\n\u003ctd data-start=\"2058\" data-end=\"2074\" data-col-size=\"sm\"\u003epH Resolution\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2074\" data-end=\"2094\"\u003e0.1 pH \/ 0.01 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2095\" data-end=\"2121\"\u003e\n\u003ctd data-start=\"2095\" data-end=\"2109\" data-col-size=\"sm\"\u003epH Accuracy\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2109\" data-end=\"2121\"\u003e±0.01 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2122\" data-end=\"2161\"\u003e\n\u003ctd data-start=\"2122\" data-end=\"2143\" data-col-size=\"sm\"\u003eCalibration Points\u003c\/td\u003e\n\u003ctd data-start=\"2143\" data-end=\"2161\" data-col-size=\"sm\"\u003eUp to 3 Points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2162\" data-end=\"2209\"\u003e\n\u003ctd data-start=\"2162\" data-end=\"2179\" data-col-size=\"sm\"\u003eBuffer Options\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2179\" data-end=\"2209\"\u003eUSA (pH 4.01, 7.00, 10.01)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2210\" data-end=\"2233\"\u003e\n\u003ctd data-start=\"2210\" data-end=\"2221\" data-col-size=\"sm\"\u003emV Range\u003c\/td\u003e\n\u003ctd data-start=\"2221\" data-end=\"2233\" data-col-size=\"sm\"\u003e±1999 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2234\" data-end=\"2287\"\u003e\n\u003ctd data-start=\"2234\" data-end=\"2261\" data-col-size=\"sm\"\u003emV Resolution \u0026amp; Accuracy\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2261\" data-end=\"2287\"\u003e±1% FS ±1 digit \u0026amp; 1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2288\" data-end=\"2324\"\u003e\n\u003ctd data-start=\"2288\" data-end=\"2308\" data-col-size=\"sm\"\u003eTemperature Range\u003c\/td\u003e\n\u003ctd data-start=\"2308\" data-end=\"2324\" data-col-size=\"sm\"\u003e0°C to 100°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2325\" data-end=\"2358\"\u003e\n\u003ctd data-start=\"2325\" data-end=\"2348\" data-col-size=\"sm\"\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2348\" data-end=\"2358\"\u003e±0.5°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2359\" data-end=\"2393\"\u003e\n\u003ctd data-start=\"2359\" data-end=\"2384\" data-col-size=\"sm\"\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2384\" data-end=\"2393\"\u003e0.1°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2394\" data-end=\"2434\"\u003e\n\u003ctd data-start=\"2394\" data-end=\"2421\" data-col-size=\"sm\"\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd data-start=\"2421\" data-end=\"2434\" data-col-size=\"sm\"\u003eAutomatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2435\" data-end=\"2454\"\u003e\n\u003ctd data-start=\"2435\" data-end=\"2447\" data-col-size=\"sm\"\u003eConnector\u003c\/td\u003e\n\u003ctd data-start=\"2447\" data-end=\"2454\" data-col-size=\"sm\"\u003eBNC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2455\" data-end=\"2472\"\u003e\n\u003ctd data-start=\"2455\" data-end=\"2465\" data-col-size=\"sm\"\u003eDisplay\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2465\" data-end=\"2472\"\u003eLCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2473\" data-end=\"2501\"\u003e\n\u003ctd data-start=\"2473\" data-end=\"2482\" data-col-size=\"sm\"\u003eMemory\u003c\/td\u003e\n\u003ctd data-start=\"2482\" data-end=\"2501\" data-col-size=\"sm\"\u003eUp to 25 Prints\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2502\" data-end=\"2550\"\u003e\n\u003ctd data-start=\"2502\" data-end=\"2517\" data-col-size=\"sm\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2517\" data-end=\"2550\"\u003eDC Adaptor, AC 220V \/ 50–60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2551\" data-end=\"2594\"\u003e\n\u003ctd data-start=\"2551\" data-end=\"2572\" data-col-size=\"sm\"\u003eDimensions (L×W×H)\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2572\" data-end=\"2594\"\u003e300 × 250 × 130 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2595\" data-end=\"2612\"\u003e\n\u003ctd data-start=\"2595\" data-end=\"2604\" data-col-size=\"sm\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-start=\"2604\" data-end=\"2612\" data-col-size=\"sm\"\u003e1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 data-start=\"2614\" data-end=\"2629\"\u003eApplications\u003c\/h3\u003e\n\u003cp data-start=\"2631\" data-end=\"2836\"\u003eWater quality testing\u003cbr data-start=\"2652\" data-end=\"2655\"\u003eEducational and academic laboratories\u003cbr data-start=\"2692\" data-end=\"2695\"\u003eChemical and environmental analysis\u003cbr data-start=\"2730\" data-end=\"2733\"\u003eRoutine pH measurement applications\u003cbr data-start=\"2768\" data-end=\"2771\"\u003eIndustrial quality control testing\u003cbr data-start=\"2805\" data-end=\"2808\"\u003eResearch laboratory analysis\u003c\/p\u003e","brand":"Labman","offers":[{"title":"Default Title","offer_id":49968461545709,"sku":null,"price":14800.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5672\/6765\/files\/LMPH9_2_c985a42c-6c72-43d3-9f74-57c1ed8a723f.webp?v=1778960534"},{"product_id":"benchtop-ph-mv-c-meter-with-usb-interface-and-atc","title":"Benchtop pH\/mV\/°C Meter LMPH10H (USB Interface and ATC)","description":"\u003cp data-start=\"243\" data-end=\"571\"\u003eBenchtop pH\/mV\/°C Meter LMPH10H is designed for precise laboratory measurement of pH, mV, and temperature across research, educational, environmental, and industrial applications. The instrument combines high measurement accuracy with intelligent calibration and user-friendly operation for routine and advanced analytical work.\u003c\/p\u003e\n\u003cp data-start=\"573\" data-end=\"837\"\u003eThe system features a large LCD display with white backlight that clearly presents measurement values, prompts, and operational guidance for simplified usage. Automatic temperature compensation ensures reliable and stable readings throughout the measurement range.\u003c\/p\u003e\n\u003cp data-start=\"839\" data-end=\"1109\"\u003eThe meter supports up to three-point calibration with automatic buffer recognition using both USA and NIST standard buffer sets. Automatic electrode diagnosis displays electrode slope and offset conditions to help maintain measurement accuracy and electrode performance.\u003c\/p\u003e\n\u003cp data-start=\"1111\" data-end=\"1437\"\u003eAn automatic endpoint function freezes stable measured values for improved repeatability, while expanded memory storage allows saving and recalling up to 100 readings. The setup menu enables customization of calibration points, pH buffer standards, resolution, temperature units, stability conditions, date, and time settings.\u003c\/p\u003e\n\u003cp data-start=\"1439\" data-end=\"1708\"\u003eWith USB connectivity, BNC electrode compatibility, and simultaneous pH, mV, and temperature measurement capability, the LMPH10H is suitable for water testing, chemical analysis, environmental monitoring, pharmaceutical laboratories, and academic research applications.\u003c\/p\u003e\n\u003ch3 data-start=\"1710\" data-end=\"1725\"\u003eKey Features\u003c\/h3\u003e\n\u003cp data-start=\"1727\" data-end=\"2265\"\u003epH, mV, and temperature measurement modes\u003cbr data-start=\"1768\" data-end=\"1771\"\u003eAutomatic temperature compensation (ATC)\u003cbr data-start=\"1811\" data-end=\"1814\"\u003eLarge LCD display with white backlight\u003cbr data-start=\"1852\" data-end=\"1855\"\u003eUp to 3-point calibration with auto buffer recognition\u003cbr data-start=\"1909\" data-end=\"1912\"\u003eSupports USA and NIST buffer standards\u003cbr data-start=\"1950\" data-end=\"1953\"\u003eAutomatic electrode diagnosis function\u003cbr data-start=\"1991\" data-end=\"1994\"\u003eAutomatic endpoint stability detection\u003cbr data-start=\"2032\" data-end=\"2035\"\u003eUSB interface for data connectivity\u003cbr data-start=\"2070\" data-end=\"2073\"\u003eMemory storage for up to 100 readings\u003cbr data-start=\"2110\" data-end=\"2113\"\u003eCustomizable calibration and setup parameters\u003cbr data-start=\"2158\" data-end=\"2161\"\u003eBNC connector for standard electrode compatibility\u003cbr data-start=\"2211\" data-end=\"2214\"\u003eSuitable for laboratory and industrial applications\u003c\/p\u003e\n\u003ch3 data-start=\"2267\" data-end=\"2294\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"2296\" data-end=\"3168\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"2296\" data-end=\"2325\"\u003e\n\u003ctr data-start=\"2296\" data-end=\"2325\"\u003e\n\u003cth data-start=\"2296\" data-end=\"2308\" data-col-size=\"sm\" class=\"\"\u003eParameter\u003c\/th\u003e\n\u003cth data-start=\"2308\" data-end=\"2325\" data-col-size=\"md\" class=\"\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"2340\" data-end=\"3168\"\u003e\n\u003ctr data-start=\"2340\" data-end=\"2371\"\u003e\n\u003ctd data-start=\"2340\" data-end=\"2348\" data-col-size=\"sm\"\u003eModes\u003c\/td\u003e\n\u003ctd data-start=\"2348\" data-end=\"2371\" data-col-size=\"md\"\u003epH, mV, Temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2372\" data-end=\"2404\"\u003e\n\u003ctd data-start=\"2372\" data-end=\"2383\" data-col-size=\"sm\"\u003epH Range\u003c\/td\u003e\n\u003ctd data-start=\"2383\" data-end=\"2404\" data-col-size=\"md\"\u003e-2.00 to 16.00 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2405\" data-end=\"2432\"\u003e\n\u003ctd data-start=\"2405\" data-end=\"2421\" data-col-size=\"sm\"\u003epH Resolution\u003c\/td\u003e\n\u003ctd data-start=\"2421\" data-end=\"2432\" data-col-size=\"md\"\u003e0.01 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2433\" data-end=\"2459\"\u003e\n\u003ctd data-start=\"2433\" data-end=\"2447\" data-col-size=\"sm\"\u003epH Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"2447\" data-end=\"2459\" data-col-size=\"md\"\u003e±0.01 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2460\" data-end=\"2492\"\u003e\n\u003ctd data-start=\"2460\" data-end=\"2474\" data-col-size=\"sm\"\u003eCalibration\u003c\/td\u003e\n\u003ctd data-start=\"2474\" data-end=\"2492\" data-col-size=\"md\"\u003eUp to 3 Points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2493\" data-end=\"2562\"\u003e\n\u003ctd data-start=\"2493\" data-end=\"2510\" data-col-size=\"sm\"\u003eBuffer Options\u003c\/td\u003e\n\u003ctd data-start=\"2510\" data-end=\"2562\" data-col-size=\"md\"\u003eUSA (4.01, 7.00, 10.01), NIST (4.01, 6.86, 9.18)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2563\" data-end=\"2601\"\u003e\n\u003ctd data-start=\"2563\" data-end=\"2594\" data-col-size=\"sm\"\u003eAutomatic Buffer Recognition\u003c\/td\u003e\n\u003ctd data-start=\"2594\" data-end=\"2601\" data-col-size=\"md\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2602\" data-end=\"2628\"\u003e\n\u003ctd data-start=\"2602\" data-end=\"2621\" data-col-size=\"sm\"\u003epH Slope Display\u003c\/td\u003e\n\u003ctd data-start=\"2621\" data-end=\"2628\" data-col-size=\"md\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2629\" data-end=\"2652\"\u003e\n\u003ctd data-start=\"2629\" data-end=\"2640\" data-col-size=\"sm\"\u003emV Range\u003c\/td\u003e\n\u003ctd data-start=\"2640\" data-end=\"2652\" data-col-size=\"md\"\u003e±1999 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2653\" data-end=\"2676\"\u003e\n\u003ctd data-start=\"2653\" data-end=\"2667\" data-col-size=\"sm\"\u003emV Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"2667\" data-end=\"2676\" data-col-size=\"md\"\u003e±1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2677\" data-end=\"2701\"\u003e\n\u003ctd data-start=\"2677\" data-end=\"2693\" data-col-size=\"sm\"\u003emV Resolution\u003c\/td\u003e\n\u003ctd data-start=\"2693\" data-end=\"2701\" data-col-size=\"md\"\u003e1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2702\" data-end=\"2736\"\u003e\n\u003ctd data-start=\"2702\" data-end=\"2722\" data-col-size=\"sm\"\u003eTemperature Range\u003c\/td\u003e\n\u003ctd data-start=\"2722\" data-end=\"2736\" data-col-size=\"md\"\u003e0 to 105°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2737\" data-end=\"2770\"\u003e\n\u003ctd data-start=\"2737\" data-end=\"2760\" data-col-size=\"sm\"\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"2760\" data-end=\"2770\" data-col-size=\"md\"\u003e±0.5°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2771\" data-end=\"2811\"\u003e\n\u003ctd data-start=\"2771\" data-end=\"2795\" data-col-size=\"sm\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd data-start=\"2795\" data-end=\"2811\" data-col-size=\"md\"\u003e10°C to 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2812\" data-end=\"2840\"\u003e\n\u003ctd data-start=\"2812\" data-end=\"2832\" data-col-size=\"sm\"\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd data-start=\"2832\" data-end=\"2840\" data-col-size=\"md\"\u003e\u0026lt;80%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2841\" data-end=\"2865\"\u003e\n\u003ctd data-start=\"2841\" data-end=\"2858\" data-col-size=\"sm\"\u003eReset Function\u003c\/td\u003e\n\u003ctd data-start=\"2858\" data-end=\"2865\" data-col-size=\"md\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2866\" data-end=\"2885\"\u003e\n\u003ctd data-start=\"2866\" data-end=\"2878\" data-col-size=\"sm\"\u003eInterface\u003c\/td\u003e\n\u003ctd data-start=\"2878\" data-end=\"2885\" data-col-size=\"md\"\u003eUSB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2886\" data-end=\"2934\"\u003e\n\u003ctd data-start=\"2886\" data-end=\"2902\" data-col-size=\"sm\"\u003eHold Function\u003c\/td\u003e\n\u003ctd data-start=\"2902\" data-end=\"2934\" data-col-size=\"md\"\u003eAutomatic Endpoint or Manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2935\" data-end=\"2966\"\u003e\n\u003ctd data-start=\"2935\" data-end=\"2944\" data-col-size=\"sm\"\u003eMemory\u003c\/td\u003e\n\u003ctd data-start=\"2944\" data-end=\"2966\" data-col-size=\"md\"\u003eUp to 100 Readings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2967\" data-end=\"2986\"\u003e\n\u003ctd data-start=\"2967\" data-end=\"2979\" data-col-size=\"sm\"\u003eConnector\u003c\/td\u003e\n\u003ctd data-start=\"2979\" data-end=\"2986\" data-col-size=\"md\"\u003eBNC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2987\" data-end=\"3025\"\u003e\n\u003ctd data-start=\"2987\" data-end=\"2997\" data-col-size=\"sm\"\u003eDisplay\u003c\/td\u003e\n\u003ctd data-start=\"2997\" data-end=\"3025\" data-col-size=\"md\"\u003eLCD with White Backlight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3026\" data-end=\"3057\"\u003e\n\u003ctd data-start=\"3026\" data-end=\"3041\" data-col-size=\"sm\"\u003eDisplay Size\u003c\/td\u003e\n\u003ctd data-start=\"3041\" data-end=\"3057\" data-col-size=\"md\"\u003e125 × 100 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3058\" data-end=\"3106\"\u003e\n\u003ctd data-start=\"3058\" data-end=\"3073\" data-col-size=\"sm\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd data-start=\"3073\" data-end=\"3106\" data-col-size=\"md\"\u003eDC Adaptor, AC 220V \/ 50–60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3107\" data-end=\"3150\"\u003e\n\u003ctd data-start=\"3107\" data-end=\"3128\" data-col-size=\"sm\"\u003eDimensions (L×W×H)\u003c\/td\u003e\n\u003ctd data-start=\"3128\" data-end=\"3150\" data-col-size=\"md\"\u003e310 × 255 × 190 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3151\" data-end=\"3168\"\u003e\n\u003ctd data-start=\"3151\" data-end=\"3160\" data-col-size=\"sm\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-start=\"3160\" data-end=\"3168\" data-col-size=\"md\"\u003e2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 data-start=\"3170\" data-end=\"3185\"\u003eApplications\u003c\/h3\u003e\n\u003cp data-start=\"3187\" data-end=\"3397\"\u003eWater and wastewater analysis\u003cbr data-start=\"3216\" data-end=\"3219\"\u003eChemical and environmental testing\u003cbr data-start=\"3253\" data-end=\"3256\"\u003eEducational and academic laboratories\u003cbr data-start=\"3293\" data-end=\"3296\"\u003ePharmaceutical quality control\u003cbr data-start=\"3326\" data-end=\"3329\"\u003eIndustrial process monitoring\u003cbr data-start=\"3358\" data-end=\"3361\"\u003eResearch and analytical laboratories\u003c\/p\u003e","brand":"Labman","offers":[{"title":"Default Title","offer_id":49968474554605,"sku":null,"price":22500.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5672\/6765\/files\/LMPH10H_2_e61c422d-abd8-41c5-a2ae-9bfb5439ff9c.webp?v=1778960608"},{"product_id":"benchtop-ph-mv-c-meter-with-5-point-calibration","title":"Benchtop pH\/mV\/°C Meter with 5-Point Calibration LMPH12","description":"\u003cp data-start=\"244\" data-end=\"602\"\u003eBenchtop pH\/mV\/°C Meter LMPH12 is a high-precision laboratory instrument designed for accurate pH, mV, ORP, and temperature measurement across research, pharmaceutical, environmental, and industrial testing applications. The instrument combines advanced calibration capability with intelligent diagnostic functions to deliver reliable analytical performance.\u003c\/p\u003e\n\u003cp data-start=\"604\" data-end=\"961\"\u003eThe system features a large backlit LCD display with user guidance prompts for simplified operation and efficient sample analysis. Automatic temperature compensation ensures accurate measurement across the entire operating range, while automatic electrode diagnostics display electrode slope after calibration for improved monitoring of electrode condition.\u003c\/p\u003e\n\u003cp data-start=\"963\" data-end=\"1226\"\u003eThe meter supports up to five-point push-button calibration with automatic buffer recognition and selectable buffer standards. It also includes calibration due reminders, helping laboratories maintain measurement accuracy through scheduled recalibration routines.\u003c\/p\u003e\n\u003cp data-start=\"1228\" data-end=\"1454\"\u003eThe instrument supports both absolute and relative millivolt measurement for precise ORP analysis. Automatic endpoint detection freezes stable measured values for consistent recording and improved repeatability during testing.\u003c\/p\u003e\n\u003cp data-start=\"1456\" data-end=\"1795\"\u003eAn expanded internal memory allows storage of up to 500 readings with date and time stamping to support GLP-compliant laboratory documentation. The setup menu enables users to customize calibration points, buffer standards, resolution, temperature units, stability conditions, and operational settings according to laboratory requirements.\u003c\/p\u003e\n\u003cp data-start=\"1797\" data-end=\"1951\"\u003eLMPH12 is suitable for laboratories requiring advanced pH analysis with high accuracy, flexible calibration, and comprehensive data management capability.\u003c\/p\u003e\n\u003ch3 data-start=\"1953\" data-end=\"1968\"\u003eKey Features\u003c\/h3\u003e\n\u003cp data-start=\"1970\" data-end=\"2543\"\u003eHigh precision pH, mV, ORP, and temperature measurement\u003cbr data-start=\"2025\" data-end=\"2028\"\u003eUp to 5-point calibration with auto buffer recognition\u003cbr data-start=\"2082\" data-end=\"2085\"\u003eAutomatic temperature compensation (ATC)\u003cbr data-start=\"2125\" data-end=\"2128\"\u003eAutomatic electrode slope diagnostics\u003cbr data-start=\"2165\" data-end=\"2168\"\u003eLarge LCD display with backlight\u003cbr data-start=\"2200\" data-end=\"2203\"\u003eAbsolute and relative mV measurement capability\u003cbr data-start=\"2250\" data-end=\"2253\"\u003eAutomatic endpoint detection function\u003cbr data-start=\"2290\" data-end=\"2293\"\u003eCalibration reminder system\u003cbr data-start=\"2320\" data-end=\"2323\"\u003eInternal memory for up to 500 readings\u003cbr data-start=\"2361\" data-end=\"2364\"\u003eDate and time stamped data storage\u003cbr data-start=\"2398\" data-end=\"2401\"\u003eSelectable pH resolution and mV resolution\u003cbr data-start=\"2443\" data-end=\"2446\"\u003eCustomizable setup and calibration parameters\u003cbr data-start=\"2491\" data-end=\"2494\"\u003eSuitable for research and industrial laboratories\u003c\/p\u003e\n\u003ch3 data-start=\"2545\" data-end=\"2572\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"2574\" data-end=\"3278\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"2574\" data-end=\"2603\"\u003e\n\u003ctr data-start=\"2574\" data-end=\"2603\"\u003e\n\u003cth data-start=\"2574\" data-end=\"2586\" data-col-size=\"sm\" class=\"\"\u003eParameter\u003c\/th\u003e\n\u003cth data-start=\"2586\" data-end=\"2603\" data-col-size=\"sm\" class=\"\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"2618\" data-end=\"3278\"\u003e\n\u003ctr data-start=\"2618\" data-end=\"2652\"\u003e\n\u003ctd data-start=\"2618\" data-end=\"2629\" data-col-size=\"sm\"\u003epH Range\u003c\/td\u003e\n\u003ctd data-start=\"2629\" data-end=\"2652\" data-col-size=\"sm\"\u003e-2.000 to 20.000 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2653\" data-end=\"2680\"\u003e\n\u003ctd data-start=\"2653\" data-end=\"2667\" data-col-size=\"sm\"\u003epH Accuracy\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2667\" data-end=\"2680\"\u003e±0.002 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2681\" data-end=\"2733\"\u003e\n\u003ctd data-start=\"2681\" data-end=\"2697\" data-col-size=\"sm\"\u003epH Resolution\u003c\/td\u003e\n\u003ctd data-start=\"2697\" data-end=\"2733\" data-col-size=\"sm\"\u003e0.001, 0.01, 0.1 pH (Selectable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2734\" data-end=\"2757\"\u003e\n\u003ctd data-start=\"2734\" data-end=\"2745\" data-col-size=\"sm\"\u003emV Range\u003c\/td\u003e\n\u003ctd data-start=\"2745\" data-end=\"2757\" data-col-size=\"sm\"\u003e±1999 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2758\" data-end=\"2783\"\u003e\n\u003ctd data-start=\"2758\" data-end=\"2772\" data-col-size=\"sm\"\u003emV Accuracy\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2772\" data-end=\"2783\"\u003e±0.2 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2784\" data-end=\"2826\"\u003e\n\u003ctd data-start=\"2784\" data-end=\"2800\" data-col-size=\"sm\"\u003emV Resolution\u003c\/td\u003e\n\u003ctd data-start=\"2800\" data-end=\"2826\" data-col-size=\"sm\"\u003e0.1, 1 mV (Selectable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2827\" data-end=\"2859\"\u003e\n\u003ctd data-start=\"2827\" data-end=\"2841\" data-col-size=\"sm\"\u003eCalibration\u003c\/td\u003e\n\u003ctd data-start=\"2841\" data-end=\"2859\" data-col-size=\"sm\"\u003eUp to 5 Points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2860\" data-end=\"2905\"\u003e\n\u003ctd data-start=\"2860\" data-end=\"2877\" data-col-size=\"sm\"\u003eBuffer Options\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2877\" data-end=\"2905\"\u003eUSA, NIST \u0026amp; User Defined\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2906\" data-end=\"2952\"\u003e\n\u003ctd data-start=\"2906\" data-end=\"2929\" data-col-size=\"sm\"\u003eCalibration Reminder\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2929\" data-end=\"2952\"\u003e1 to 30 Days or Off\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2953\" data-end=\"2996\"\u003e\n\u003ctd data-start=\"2953\" data-end=\"2973\" data-col-size=\"sm\"\u003eTemperature Range\u003c\/td\u003e\n\u003ctd data-start=\"2973\" data-end=\"2996\" data-col-size=\"sm\"\u003e0°–105°C, 32°–212°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2997\" data-end=\"3038\"\u003e\n\u003ctd data-start=\"2997\" data-end=\"3020\" data-col-size=\"sm\"\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3020\" data-end=\"3038\"\u003e±0.5°C, ±0.9°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3039\" data-end=\"3089\"\u003e\n\u003ctd data-start=\"3039\" data-end=\"3066\" data-col-size=\"sm\"\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd data-start=\"3066\" data-end=\"3089\" data-col-size=\"sm\"\u003eAutomatic or Manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3090\" data-end=\"3124\"\u003e\n\u003ctd data-start=\"3090\" data-end=\"3101\" data-col-size=\"sm\"\u003eAuto-Off\u003c\/td\u003e\n\u003ctd data-start=\"3101\" data-end=\"3124\" data-col-size=\"sm\"\u003eManual or Automatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3125\" data-end=\"3167\"\u003e\n\u003ctd data-start=\"3125\" data-end=\"3134\" data-col-size=\"sm\"\u003eMemory\u003c\/td\u003e\n\u003ctd data-start=\"3134\" data-end=\"3167\" data-col-size=\"sm\"\u003e500 Readings with Date \u0026amp; Time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3168\" data-end=\"3216\"\u003e\n\u003ctd data-start=\"3168\" data-end=\"3183\" data-col-size=\"sm\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd data-start=\"3183\" data-end=\"3216\" data-col-size=\"sm\"\u003eDC Adaptor, AC 220V \/ 50–60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3217\" data-end=\"3260\"\u003e\n\u003ctd data-start=\"3217\" data-end=\"3238\" data-col-size=\"sm\"\u003eDimensions (L×W×H)\u003c\/td\u003e\n\u003ctd data-start=\"3238\" data-end=\"3260\" data-col-size=\"sm\"\u003e310 × 250 × 190 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3261\" data-end=\"3278\"\u003e\n\u003ctd data-start=\"3261\" data-end=\"3270\" data-col-size=\"sm\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-start=\"3270\" data-end=\"3278\" data-col-size=\"sm\"\u003e2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 data-start=\"3280\" data-end=\"3295\"\u003eApplications\u003c\/h3\u003e\n\u003cp data-start=\"3297\" data-end=\"3503\"\u003ePharmaceutical laboratory analysis\u003cbr data-start=\"3331\" data-end=\"3334\"\u003eWater and wastewater testing\u003cbr data-start=\"3362\" data-end=\"3365\"\u003eEnvironmental monitoring\u003cbr data-start=\"3389\" data-end=\"3392\"\u003eChemical and industrial quality control\u003cbr data-start=\"3431\" data-end=\"3434\"\u003eResearch and academic laboratories\u003cbr data-start=\"3468\" data-end=\"3471\"\u003eORP and electrochemical analysis\u003c\/p\u003e","brand":"Labman","offers":[{"title":"Default Title","offer_id":49968478093549,"sku":null,"price":45000.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5672\/6765\/files\/LMPH12.jpg?v=1778960645"},{"product_id":"benchtop-ph-meter-with-thermal-printer-and-5-point-calibration","title":"Benchtop pH Meter LMPH15 (Thermal Printer, 5-Point Calibration)","description":"\u003cp data-start=\"272\" data-end=\"652\"\u003eBenchtop pH Meter with Thermal Printer LMPH15 is a high-precision laboratory instrument designed for accurate pH, ORP, mV, and temperature measurement with integrated printing and advanced data management functionality. The system is suitable for pharmaceutical laboratories, research facilities, environmental testing, water analysis, and industrial quality control applications.\u003c\/p\u003e\n\u003cp data-start=\"654\" data-end=\"913\"\u003eThe instrument supports 1 to 5 point calibration with automatic recognition of USA, NIST, DIN, and user-defined buffer standards. Automatic electrode diagnostics continuously monitor electrode slope and zero offset to maintain reliable analytical performance.\u003c\/p\u003e\n\u003cp data-start=\"915\" data-end=\"1181\"\u003eThe integrated thermal printer enables direct printing of interval readings and measurement reports, improving laboratory documentation and traceability. Built-in real-time clock functionality supports GLP-compliant data records with accurate date and time stamping.\u003c\/p\u003e\n\u003cp data-start=\"1183\" data-end=\"1472\"\u003eLMPH15 provides both relative and absolute millivolt measurement modes for reliable ORP analysis. Automatic temperature compensation ensures stable and accurate readings across the measurement range, while auto-read endpoint sensing locks stable measured values for improved repeatability.\u003c\/p\u003e\n\u003cp data-start=\"1474\" data-end=\"1762\"\u003eThe system also includes calibration due alarms, password protection for calibration settings, high\/low limit alarm functions, and internal memory storage for up to 1000 data sets. A large 7-inch TFT LCD display provides clear visualization of measurement values and operational settings.\u003c\/p\u003e\n\u003cp data-start=\"1764\" data-end=\"1921\"\u003eDesigned for advanced laboratory workflows, the instrument combines high analytical accuracy with integrated reporting and secure data handling capabilities.\u003c\/p\u003e\n\u003ch3 data-start=\"1923\" data-end=\"1938\"\u003eKey Features\u003c\/h3\u003e\n\u003cp data-start=\"1940\" data-end=\"2535\"\u003eIntegrated thermal printer for direct result printing\u003cbr data-start=\"1993\" data-end=\"1996\"\u003e1 to 5 point calibration with auto buffer recognition\u003cbr data-start=\"2049\" data-end=\"2052\"\u003eSupports USA, NIST, DIN, and user-defined buffers\u003cbr data-start=\"2101\" data-end=\"2104\"\u003eAutomatic temperature compensation (ATC)\u003cbr data-start=\"2144\" data-end=\"2147\"\u003eORP and mV measurement capability\u003cbr data-start=\"2180\" data-end=\"2183\"\u003eAutomatic electrode diagnostics\u003cbr data-start=\"2214\" data-end=\"2217\"\u003eAuto-read endpoint sensing function\u003cbr data-start=\"2252\" data-end=\"2255\"\u003e7-inch TFT LCD display\u003cbr data-start=\"2277\" data-end=\"2280\"\u003ePassword protection for calibration settings\u003cbr data-start=\"2324\" data-end=\"2327\"\u003eHigh and low limit alarm system\u003cbr data-start=\"2358\" data-end=\"2361\"\u003eGLP-compliant real-time clock data stamping\u003cbr data-start=\"2404\" data-end=\"2407\"\u003eMemory storage for up to 1000 data sets\u003cbr data-start=\"2446\" data-end=\"2449\"\u003eRelative and absolute mV measurement modes\u003cbr data-start=\"2491\" data-end=\"2494\"\u003eSuitable for advanced laboratory analysis\u003c\/p\u003e\n\u003ch3 data-start=\"2537\" data-end=\"2564\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"2566\" data-end=\"3413\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"2566\" data-end=\"2595\"\u003e\n\u003ctr data-start=\"2566\" data-end=\"2595\"\u003e\n\u003cth data-start=\"2566\" data-end=\"2578\" data-col-size=\"sm\" class=\"\"\u003eParameter\u003c\/th\u003e\n\u003cth data-start=\"2578\" data-end=\"2595\" data-col-size=\"sm\" class=\"\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"2610\" data-end=\"3413\"\u003e\n\u003ctr data-start=\"2610\" data-end=\"2644\"\u003e\n\u003ctd data-start=\"2610\" data-end=\"2621\" data-col-size=\"sm\"\u003epH Range\u003c\/td\u003e\n\u003ctd data-start=\"2621\" data-end=\"2644\" data-col-size=\"sm\"\u003e-2.000 to 20.000 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2645\" data-end=\"2689\"\u003e\n\u003ctd data-start=\"2645\" data-end=\"2661\" data-col-size=\"sm\"\u003epH Resolution\u003c\/td\u003e\n\u003ctd data-start=\"2661\" data-end=\"2689\" data-col-size=\"sm\"\u003e0.001, 0.01 (Selectable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2690\" data-end=\"2717\"\u003e\n\u003ctd data-start=\"2690\" data-end=\"2704\" data-col-size=\"sm\"\u003epH Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"2704\" data-end=\"2717\" data-col-size=\"sm\"\u003e±0.002 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2718\" data-end=\"2757\"\u003e\n\u003ctd data-start=\"2718\" data-end=\"2739\" data-col-size=\"sm\"\u003eCalibration Points\u003c\/td\u003e\n\u003ctd data-start=\"2739\" data-end=\"2757\" data-col-size=\"sm\"\u003eUp to 5 Points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2758\" data-end=\"2807\"\u003e\n\u003ctd data-start=\"2758\" data-end=\"2775\" data-col-size=\"sm\"\u003eBuffer Options\u003c\/td\u003e\n\u003ctd data-start=\"2775\" data-end=\"2807\" data-col-size=\"sm\"\u003eUSA, NIST, DIN, User Defined\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2808\" data-end=\"2831\"\u003e\n\u003ctd data-start=\"2808\" data-end=\"2819\" data-col-size=\"sm\"\u003emV Range\u003c\/td\u003e\n\u003ctd data-start=\"2819\" data-end=\"2831\" data-col-size=\"sm\"\u003e±2000 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2832\" data-end=\"2857\"\u003e\n\u003ctd data-start=\"2832\" data-end=\"2846\" data-col-size=\"sm\"\u003emV Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"2846\" data-end=\"2857\" data-col-size=\"sm\"\u003e±0.2 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2858\" data-end=\"2884\"\u003e\n\u003ctd data-start=\"2858\" data-end=\"2874\" data-col-size=\"sm\"\u003emV Resolution\u003c\/td\u003e\n\u003ctd data-start=\"2874\" data-end=\"2884\" data-col-size=\"sm\"\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2885\" data-end=\"2929\"\u003e\n\u003ctd data-start=\"2885\" data-end=\"2905\" data-col-size=\"sm\"\u003eTemperature Range\u003c\/td\u003e\n\u003ctd data-start=\"2905\" data-end=\"2929\" data-col-size=\"sm\"\u003e0°–105°C \/ 32°–221°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2930\" data-end=\"2972\"\u003e\n\u003ctd data-start=\"2930\" data-end=\"2953\" data-col-size=\"sm\"\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"2953\" data-end=\"2972\" data-col-size=\"sm\"\u003e±0.5°C \/ ±0.9°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2973\" data-end=\"3015\"\u003e\n\u003ctd data-start=\"2973\" data-end=\"2998\" data-col-size=\"sm\"\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd data-start=\"2998\" data-end=\"3015\" data-col-size=\"sm\"\u003e0.1°C \/ 0.1°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3016\" data-end=\"3065\"\u003e\n\u003ctd data-start=\"3016\" data-end=\"3043\" data-col-size=\"sm\"\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd data-start=\"3043\" data-end=\"3065\" data-col-size=\"sm\"\u003eManual \/ Automatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3066\" data-end=\"3095\"\u003e\n\u003ctd data-start=\"3066\" data-end=\"3084\" data-col-size=\"sm\"\u003eInput Impedance\u003c\/td\u003e\n\u003ctd data-start=\"3084\" data-end=\"3095\" data-col-size=\"sm\"\u003e\u0026lt;10¹² Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3096\" data-end=\"3137\"\u003e\n\u003ctd data-start=\"3096\" data-end=\"3108\" data-col-size=\"sm\"\u003eStability\u003c\/td\u003e\n\u003ctd data-start=\"3108\" data-end=\"3137\" data-col-size=\"sm\"\u003eStandard or High Accuracy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3138\" data-end=\"3185\"\u003e\n\u003ctd data-start=\"3138\" data-end=\"3162\" data-col-size=\"sm\"\u003eCalibration Due Alarm\u003c\/td\u003e\n\u003ctd data-start=\"3162\" data-end=\"3185\" data-col-size=\"sm\"\u003e1 to 31 Days or Off\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3186\" data-end=\"3225\"\u003e\n\u003ctd data-start=\"3186\" data-end=\"3208\" data-col-size=\"sm\"\u003ePassword Protection\u003c\/td\u003e\n\u003ctd data-start=\"3208\" data-end=\"3225\" data-col-size=\"sm\"\u003eYes, 4 Digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3226\" data-end=\"3253\"\u003e\n\u003ctd data-start=\"3226\" data-end=\"3235\" data-col-size=\"sm\"\u003eMemory\u003c\/td\u003e\n\u003ctd data-start=\"3235\" data-end=\"3253\" data-col-size=\"sm\"\u003e1000 Data Sets\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3254\" data-end=\"3273\"\u003e\n\u003ctd data-start=\"3254\" data-end=\"3266\" data-col-size=\"sm\"\u003eConnector\u003c\/td\u003e\n\u003ctd data-start=\"3266\" data-end=\"3273\" data-col-size=\"sm\"\u003eBNC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3274\" data-end=\"3302\"\u003e\n\u003ctd data-start=\"3274\" data-end=\"3284\" data-col-size=\"sm\"\u003eDisplay\u003c\/td\u003e\n\u003ctd data-start=\"3284\" data-end=\"3302\" data-col-size=\"sm\"\u003e7-inch TFT LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3303\" data-end=\"3351\"\u003e\n\u003ctd data-start=\"3303\" data-end=\"3318\" data-col-size=\"sm\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd data-start=\"3318\" data-end=\"3351\" data-col-size=\"sm\"\u003eDC Adaptor, AC 220V \/ 50–60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3352\" data-end=\"3395\"\u003e\n\u003ctd data-start=\"3352\" data-end=\"3373\" data-col-size=\"sm\"\u003eDimensions (L×W×H)\u003c\/td\u003e\n\u003ctd data-start=\"3373\" data-end=\"3395\" data-col-size=\"sm\"\u003e330 × 235 × 420 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3396\" data-end=\"3413\"\u003e\n\u003ctd data-start=\"3396\" data-end=\"3405\" data-col-size=\"sm\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-start=\"3405\" data-end=\"3413\" data-col-size=\"sm\"\u003e2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 data-start=\"3415\" data-end=\"3430\"\u003eApplications\u003c\/h3\u003e\n\u003cp data-start=\"3432\" data-end=\"3679\"\u003ePharmaceutical laboratory analysis\u003cbr data-start=\"3466\" data-end=\"3469\"\u003eWater and wastewater testing\u003cbr data-start=\"3497\" data-end=\"3500\"\u003eEnvironmental monitoring\u003cbr data-start=\"3524\" data-end=\"3527\"\u003eChemical and industrial quality control\u003cbr data-start=\"3566\" data-end=\"3569\"\u003eResearch and academic laboratories\u003cbr data-start=\"3603\" data-end=\"3606\"\u003eORP and electrochemical analysis\u003cbr data-start=\"3638\" data-end=\"3641\"\u003eGLP-compliant laboratory documentation\u003c\/p\u003e","brand":"Labman","offers":[{"title":"Default Title","offer_id":49968482025709,"sku":null,"price":70000.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5672\/6765\/files\/LMPH15.webp?v=1778960706"},{"product_id":"conductivity-tds-meter-with-auto-ranging-and-usb-interface","title":"Conductivity \/ TDS Meter LMCM20H (Auto Ranging, USB Interface)","description":"\u003cp data-start=\"272\" data-end=\"656\"\u003eConductivity \/ TDS Meter LMCM20H is a microprocessor-based laboratory instrument designed for accurate measurement of conductivity, total dissolved solids (TDS), and temperature in water, chemical, environmental, and industrial testing applications. The system features automatic ranging capability and intelligent calibration functions for stable and reliable analytical performance.\u003c\/p\u003e\n\u003cp data-start=\"658\" data-end=\"954\"\u003eThe instrument supports conductivity, TDS, and temperature measurement modes with automatic temperature compensation to ensure accurate readings across varying sample conditions. A large LCD display with white backlight provides clear visualization of measurement data and operational parameters.\u003c\/p\u003e\n\u003cp data-start=\"956\" data-end=\"1239\"\u003eLMCM20H supports 1 to 3 point calibration with automatic recognition of conductivity standards, enabling fast and simplified calibration procedures. Users can select cell constants and reference temperatures according to specific laboratory applications and measurement requirements.\u003c\/p\u003e\n\u003cp data-start=\"1241\" data-end=\"1525\"\u003eThe auto-read endpoint function automatically detects stable values and locks the measurement for improved repeatability and consistency. Internal memory allows storage and recall of up to 100 readings, while USB connectivity enables convenient data transfer and external interfacing.\u003c\/p\u003e\n\u003cp data-start=\"1527\" data-end=\"1767\"\u003eThe instrument is suitable for laboratory water analysis, pharmaceutical testing, chemical processing, environmental monitoring, food industry applications, and industrial quality control requiring accurate conductivity and TDS measurement.\u003c\/p\u003e\n\u003ch3 data-start=\"1769\" data-end=\"1784\"\u003eKey Features\u003c\/h3\u003e\n\u003cp data-start=\"1786\" data-end=\"2333\"\u003eConductivity, TDS, and temperature measurement modes\u003cbr data-start=\"1838\" data-end=\"1841\"\u003eAutomatic conductivity and TDS ranging\u003cbr data-start=\"1879\" data-end=\"1882\"\u003eAutomatic temperature compensation\u003cbr data-start=\"1916\" data-end=\"1919\"\u003e1 to 3 point calibration with auto standard recognition\u003cbr data-start=\"1974\" data-end=\"1977\"\u003eSelectable cell constant and reference temperature\u003cbr data-start=\"2027\" data-end=\"2030\"\u003eAuto-read endpoint sensing function\u003cbr data-start=\"2065\" data-end=\"2068\"\u003eLarge LCD display with white backlight\u003cbr data-start=\"2106\" data-end=\"2109\"\u003eUSB interface for data transfer\u003cbr data-start=\"2140\" data-end=\"2143\"\u003eMemory storage for up to 100 readings\u003cbr data-start=\"2180\" data-end=\"2183\"\u003eManual and automatic temperature compensation modes\u003cbr data-start=\"2234\" data-end=\"2237\"\u003eSuitable for laboratory and industrial water analysis\u003cbr data-start=\"2290\" data-end=\"2293\"\u003eUser-friendly setup and calibration menu\u003c\/p\u003e\n\u003ch3 data-start=\"2335\" data-end=\"2362\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"2364\" data-end=\"3415\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"2364\" data-end=\"2393\"\u003e\n\u003ctr data-start=\"2364\" data-end=\"2393\"\u003e\n\u003cth data-start=\"2364\" data-end=\"2376\" data-col-size=\"sm\" class=\"\"\u003eParameter\u003c\/th\u003e\n\u003cth data-start=\"2376\" data-end=\"2393\" data-col-size=\"md\" class=\"\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"2408\" data-end=\"3415\"\u003e\n\u003ctr data-start=\"2408\" data-end=\"2450\"\u003e\n\u003ctd data-start=\"2408\" data-end=\"2416\" data-col-size=\"sm\"\u003eModes\u003c\/td\u003e\n\u003ctd data-start=\"2416\" data-end=\"2450\" data-col-size=\"md\"\u003eConductivity, TDS, Temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2451\" data-end=\"2521\"\u003e\n\u003ctd data-start=\"2451\" data-end=\"2472\" data-col-size=\"sm\"\u003eConductivity Range\u003c\/td\u003e\n\u003ctd data-start=\"2472\" data-end=\"2521\" data-col-size=\"md\"\u003e0–20.0, 200.0, 2000 µS\/cm, 20.00, 200.0 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2522\" data-end=\"2564\"\u003e\n\u003ctd data-start=\"2522\" data-end=\"2548\" data-col-size=\"sm\"\u003eConductivity Resolution\u003c\/td\u003e\n\u003ctd data-start=\"2548\" data-end=\"2564\" data-col-size=\"md\"\u003e0.01, 0.1, 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2565\" data-end=\"2603\"\u003e\n\u003ctd data-start=\"2565\" data-end=\"2589\" data-col-size=\"sm\"\u003eConductivity Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"2589\" data-end=\"2603\" data-col-size=\"md\"\u003e±0.5% F.S.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2604\" data-end=\"2643\"\u003e\n\u003ctd data-start=\"2604\" data-end=\"2625\" data-col-size=\"sm\"\u003eCalibration Points\u003c\/td\u003e\n\u003ctd data-start=\"2625\" data-end=\"2643\" data-col-size=\"md\"\u003eUp to 3 Points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2644\" data-end=\"2728\"\u003e\n\u003ctd data-start=\"2644\" data-end=\"2668\" data-col-size=\"sm\"\u003eCalibration Solutions\u003c\/td\u003e\n\u003ctd data-start=\"2668\" data-end=\"2728\" data-col-size=\"md\"\u003e10 µS\/cm, 84 µS\/cm, 1413 µS\/cm, 12.88 mS\/cm, 111.8 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2729\" data-end=\"2753\"\u003e\n\u003ctd data-start=\"2729\" data-end=\"2741\" data-col-size=\"sm\"\u003eTDS Range\u003c\/td\u003e\n\u003ctd data-start=\"2741\" data-end=\"2753\" data-col-size=\"md\"\u003e0–10 ppt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2754\" data-end=\"2781\"\u003e\n\u003ctd data-start=\"2754\" data-end=\"2769\" data-col-size=\"sm\"\u003eTDS Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"2769\" data-end=\"2781\" data-col-size=\"md\"\u003e±1% F.S.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2782\" data-end=\"2823\"\u003e\n\u003ctd data-start=\"2782\" data-end=\"2795\" data-col-size=\"sm\"\u003eTDS Factor\u003c\/td\u003e\n\u003ctd data-start=\"2795\" data-end=\"2823\" data-col-size=\"md\"\u003e0.1 to 1.0 (Default 0.5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2824\" data-end=\"2858\"\u003e\n\u003ctd data-start=\"2824\" data-end=\"2844\" data-col-size=\"sm\"\u003eTemperature Range\u003c\/td\u003e\n\u003ctd data-start=\"2844\" data-end=\"2858\" data-col-size=\"md\"\u003e0 to 105°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2859\" data-end=\"2893\"\u003e\n\u003ctd data-start=\"2859\" data-end=\"2884\" data-col-size=\"sm\"\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd data-start=\"2884\" data-end=\"2893\" data-col-size=\"md\"\u003e0.1°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2894\" data-end=\"2927\"\u003e\n\u003ctd data-start=\"2894\" data-end=\"2917\" data-col-size=\"sm\"\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"2917\" data-end=\"2927\" data-col-size=\"md\"\u003e±0.5°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2928\" data-end=\"2978\"\u003e\n\u003ctd data-start=\"2928\" data-end=\"2955\" data-col-size=\"sm\"\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd data-start=\"2955\" data-end=\"2978\" data-col-size=\"md\"\u003eManual or Automatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2979\" data-end=\"3020\"\u003e\n\u003ctd data-start=\"2979\" data-end=\"3002\" data-col-size=\"sm\"\u003eCell Constant Option\u003c\/td\u003e\n\u003ctd data-start=\"3002\" data-end=\"3020\" data-col-size=\"md\"\u003eK = 0.1, 1, 10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3021\" data-end=\"3057\"\u003e\n\u003ctd data-start=\"3021\" data-end=\"3049\" data-col-size=\"sm\"\u003eNormalization Temperature\u003c\/td\u003e\n\u003ctd data-start=\"3049\" data-end=\"3057\" data-col-size=\"md\"\u003e25°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3058\" data-end=\"3089\"\u003e\n\u003ctd data-start=\"3058\" data-end=\"3067\" data-col-size=\"sm\"\u003eMemory\u003c\/td\u003e\n\u003ctd data-start=\"3067\" data-end=\"3089\" data-col-size=\"md\"\u003eUp to 100 Readings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3090\" data-end=\"3114\"\u003e\n\u003ctd data-start=\"3090\" data-end=\"3107\" data-col-size=\"sm\"\u003eReset Function\u003c\/td\u003e\n\u003ctd data-start=\"3107\" data-end=\"3114\" data-col-size=\"md\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3115\" data-end=\"3134\"\u003e\n\u003ctd data-start=\"3115\" data-end=\"3127\" data-col-size=\"sm\"\u003eInterface\u003c\/td\u003e\n\u003ctd data-start=\"3127\" data-end=\"3134\" data-col-size=\"md\"\u003eUSB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3135\" data-end=\"3166\"\u003e\n\u003ctd data-start=\"3135\" data-end=\"3147\" data-col-size=\"sm\"\u003eConnector\u003c\/td\u003e\n\u003ctd data-start=\"3147\" data-end=\"3166\" data-col-size=\"md\"\u003e6 Pin Mini Plug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3167\" data-end=\"3205\"\u003e\n\u003ctd data-start=\"3167\" data-end=\"3191\" data-col-size=\"sm\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd data-start=\"3191\" data-end=\"3205\" data-col-size=\"md\"\u003e10 to 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3206\" data-end=\"3234\"\u003e\n\u003ctd data-start=\"3206\" data-end=\"3226\" data-col-size=\"sm\"\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd data-start=\"3226\" data-end=\"3234\" data-col-size=\"md\"\u003e\u0026lt;80%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3235\" data-end=\"3273\"\u003e\n\u003ctd data-start=\"3235\" data-end=\"3245\" data-col-size=\"sm\"\u003eDisplay\u003c\/td\u003e\n\u003ctd data-start=\"3245\" data-end=\"3273\" data-col-size=\"md\"\u003eLCD with White Backlight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3274\" data-end=\"3304\"\u003e\n\u003ctd data-start=\"3274\" data-end=\"3289\" data-col-size=\"sm\"\u003eDisplay Size\u003c\/td\u003e\n\u003ctd data-start=\"3289\" data-end=\"3304\" data-col-size=\"md\"\u003e25 × 100 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3305\" data-end=\"3353\"\u003e\n\u003ctd data-start=\"3305\" data-end=\"3320\" data-col-size=\"sm\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd data-start=\"3320\" data-end=\"3353\" data-col-size=\"md\"\u003eDC Adaptor, AC 220V \/ 50–60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3354\" data-end=\"3397\"\u003e\n\u003ctd data-start=\"3354\" data-end=\"3375\" data-col-size=\"sm\"\u003eDimensions (L×W×H)\u003c\/td\u003e\n\u003ctd data-start=\"3375\" data-end=\"3397\" data-col-size=\"md\"\u003e310 × 255 × 200 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3398\" data-end=\"3415\"\u003e\n\u003ctd data-start=\"3398\" data-end=\"3407\" data-col-size=\"sm\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-start=\"3407\" data-end=\"3415\" data-col-size=\"md\"\u003e2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 data-start=\"3417\" data-end=\"3432\"\u003eApplications\u003c\/h3\u003e\n\u003cp data-start=\"3434\" data-end=\"3685\"\u003eWater and wastewater testing\u003cbr data-start=\"3462\" data-end=\"3465\"\u003eRO and purified water analysis\u003cbr data-start=\"3495\" data-end=\"3498\"\u003eEnvironmental monitoring laboratories\u003cbr data-start=\"3535\" data-end=\"3538\"\u003eChemical and pharmaceutical testing\u003cbr data-start=\"3573\" data-end=\"3576\"\u003eFood and beverage quality control\u003cbr data-start=\"3609\" data-end=\"3612\"\u003eIndustrial process water analysis\u003cbr data-start=\"3645\" data-end=\"3648\"\u003eEducational and research laboratories\u003c\/p\u003e","brand":"Labman","offers":[{"title":"Default Title","offer_id":49968484810989,"sku":null,"price":25000.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5672\/6765\/files\/LMCM20H.jpg?v=1778960775"},{"product_id":"water-quality-multiparameter-meter-for-ph-orp-conductivity-tds","title":"Water Quality Multiparameter Meter LMMP30 (pH, ORP, Conductivity, TDS)","description":"\u003cp data-start=\"271\" data-end=\"693\"\u003eWater Quality Multiparameter LMMP30 is a high-performance laboratory instrument designed for comprehensive water analysis applications including pH, ORP, conductivity, TDS, salinity, resistivity, and temperature measurement. The system combines multiple analytical functions into a single platform for accurate and efficient testing in research, environmental, pharmaceutical, industrial, and water treatment laboratories.\u003c\/p\u003e\n\u003cp data-start=\"695\" data-end=\"1010\"\u003eThe instrument supports up to 5-point push-button calibration with automatic buffer recognition for pH measurement and customizable calibration solutions for conductivity analysis. Automatic electrode diagnostics continuously monitor electrode slope and offset, helping users maintain reliable measurement accuracy.\u003c\/p\u003e\n\u003cp data-start=\"1012\" data-end=\"1285\"\u003eLMMP30 features automatic temperature compensation for highly stable and repeatable readings across different sample conditions. Users can select temperature units, compensation modes, normalization temperature, and salinity standards according to application requirements.\u003c\/p\u003e\n\u003cp data-start=\"1287\" data-end=\"1573\"\u003eThe system supports absolute and relative mV measurement for ORP analysis, along with conductivity, TDS, salinity, and resistivity testing using selectable cell constants and compensation settings. Auto endpoint detection freezes stable measured values for easier reading and recording.\u003c\/p\u003e\n\u003cp data-start=\"1575\" data-end=\"1793\"\u003eA large backlit LCD interface provides clear visualization of all parameters and operational prompts. Built-in memory stores up to 500 data sets with date and time records to support GLP-compliant laboratory workflows.\u003c\/p\u003e\n\u003cp data-start=\"1795\" data-end=\"2018\"\u003eThe LMMP30 is suitable for water treatment facilities, environmental monitoring laboratories, pharmaceutical quality control, food and beverage analysis, chemical processing, aquaculture, and academic research applications.\u003c\/p\u003e\n\u003ch3 data-start=\"2020\" data-end=\"2035\"\u003eKey Features\u003c\/h3\u003e\n\u003cp data-start=\"2037\" data-end=\"2704\"\u003epH, ORP, conductivity, TDS, salinity, resistivity, and temperature measurement\u003cbr data-start=\"2115\" data-end=\"2118\"\u003eUp to 5-point calibration with auto buffer recognition\u003cbr data-start=\"2172\" data-end=\"2175\"\u003eAutomatic temperature compensation\u003cbr data-start=\"2209\" data-end=\"2212\"\u003eAutomatic endpoint detection for stable readings\u003cbr data-start=\"2260\" data-end=\"2263\"\u003eAbsolute and relative mV ORP measurement\u003cbr data-start=\"2303\" data-end=\"2306\"\u003eSelectable conductivity compensation modes\u003cbr data-start=\"2348\" data-end=\"2351\"\u003eSalinity measurement in PSU or seawater standards\u003cbr data-start=\"2400\" data-end=\"2403\"\u003eAutomatic electrode diagnosis with slope and offset display\u003cbr data-start=\"2462\" data-end=\"2465\"\u003eLarge LCD display with operational guidance\u003cbr data-start=\"2508\" data-end=\"2511\"\u003eMemory storage for up to 500 data sets\u003cbr data-start=\"2549\" data-end=\"2552\"\u003eBuilt-in real-time clock with date and time stamping\u003cbr data-start=\"2604\" data-end=\"2607\"\u003eSelectable temperature units in °C and °F\u003cbr data-start=\"2648\" data-end=\"2651\"\u003eSuitable for laboratory and industrial water analysis\u003c\/p\u003e\n\u003ch3 data-start=\"2706\" data-end=\"2733\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"2735\" data-end=\"4334\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"2735\" data-end=\"2764\"\u003e\n\u003ctr data-start=\"2735\" data-end=\"2764\"\u003e\n\u003cth data-start=\"2735\" data-end=\"2747\" data-col-size=\"sm\" class=\"\"\u003eParameter\u003c\/th\u003e\n\u003cth data-start=\"2747\" data-end=\"2764\" data-col-size=\"md\" class=\"\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"2779\" data-end=\"4334\"\u003e\n\u003ctr data-start=\"2779\" data-end=\"2813\"\u003e\n\u003ctd data-start=\"2779\" data-end=\"2790\" data-col-size=\"sm\"\u003epH Range\u003c\/td\u003e\n\u003ctd data-start=\"2790\" data-end=\"2813\" data-col-size=\"md\"\u003e-2.000 to 20.000 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2814\" data-end=\"2853\"\u003e\n\u003ctd data-start=\"2814\" data-end=\"2830\" data-col-size=\"sm\"\u003epH Resolution\u003c\/td\u003e\n\u003ctd data-start=\"2830\" data-end=\"2853\" data-col-size=\"md\"\u003e0.001, 0.01, 0.1 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2854\" data-end=\"2881\"\u003e\n\u003ctd data-start=\"2854\" data-end=\"2868\" data-col-size=\"sm\"\u003epH Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"2868\" data-end=\"2881\" data-col-size=\"md\"\u003e±0.002 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2882\" data-end=\"2924\"\u003e\n\u003ctd data-start=\"2882\" data-end=\"2906\" data-col-size=\"sm\"\u003epH Calibration Points\u003c\/td\u003e\n\u003ctd data-start=\"2906\" data-end=\"2924\" data-col-size=\"md\"\u003eUp to 5 Points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2925\" data-end=\"2972\"\u003e\n\u003ctd data-start=\"2925\" data-end=\"2945\" data-col-size=\"sm\"\u003epH Buffer Options\u003c\/td\u003e\n\u003ctd data-start=\"2945\" data-end=\"2972\" data-col-size=\"md\"\u003eUSA, NIST, User Defined\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2973\" data-end=\"3002\"\u003e\n\u003ctd data-start=\"2973\" data-end=\"2985\" data-col-size=\"sm\"\u003eORP Range\u003c\/td\u003e\n\u003ctd data-start=\"2985\" data-end=\"3002\" data-col-size=\"md\"\u003e0 to ±1999 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3003\" data-end=\"3034\"\u003e\n\u003ctd data-start=\"3003\" data-end=\"3020\" data-col-size=\"sm\"\u003eORP Resolution\u003c\/td\u003e\n\u003ctd data-start=\"3020\" data-end=\"3034\" data-col-size=\"md\"\u003e0.1 \/ 1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3035\" data-end=\"3061\"\u003e\n\u003ctd data-start=\"3035\" data-end=\"3050\" data-col-size=\"sm\"\u003eORP Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"3050\" data-end=\"3061\" data-col-size=\"md\"\u003e±0.2 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3062\" data-end=\"3115\"\u003e\n\u003ctd data-start=\"3062\" data-end=\"3085\" data-col-size=\"sm\"\u003eORP Measurement Mode\u003c\/td\u003e\n\u003ctd data-start=\"3085\" data-end=\"3115\" data-col-size=\"md\"\u003eAbsolute mV or Relative mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3116\" data-end=\"3152\"\u003e\n\u003ctd data-start=\"3116\" data-end=\"3137\" data-col-size=\"sm\"\u003eConductivity Range\u003c\/td\u003e\n\u003ctd data-start=\"3137\" data-end=\"3152\" data-col-size=\"md\"\u003e0–200 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3153\" data-end=\"3197\"\u003e\n\u003ctd data-start=\"3153\" data-end=\"3179\" data-col-size=\"sm\"\u003eConductivity Resolution\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3179\" data-end=\"3197\"\u003e0.01 \/ 0.1 \/ 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3198\" data-end=\"3242\"\u003e\n\u003ctd data-start=\"3198\" data-end=\"3222\" data-col-size=\"sm\"\u003eConductivity Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"3222\" data-end=\"3242\" data-col-size=\"md\"\u003e±0.5% Full Scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3243\" data-end=\"3289\"\u003e\n\u003ctd data-start=\"3243\" data-end=\"3259\" data-col-size=\"sm\"\u003eCell Constant\u003c\/td\u003e\n\u003ctd data-start=\"3259\" data-end=\"3289\" data-col-size=\"md\"\u003e0.01 \/ 1 \/ 10 User Defined\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3290\" data-end=\"3336\"\u003e\n\u003ctd data-start=\"3290\" data-end=\"3316\" data-col-size=\"sm\"\u003eTemperature Coefficient\u003c\/td\u003e\n\u003ctd data-start=\"3316\" data-end=\"3336\" data-col-size=\"md\"\u003e0.0–10.0% per °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3337\" data-end=\"3389\"\u003e\n\u003ctd data-start=\"3337\" data-end=\"3371\" data-col-size=\"sm\"\u003eConductivity Calibration Points\u003c\/td\u003e\n\u003ctd data-start=\"3371\" data-end=\"3389\" data-col-size=\"md\"\u003eUp to 5 Points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3390\" data-end=\"3474\"\u003e\n\u003ctd data-start=\"3390\" data-end=\"3414\" data-col-size=\"sm\"\u003eCalibration Solutions\u003c\/td\u003e\n\u003ctd data-start=\"3414\" data-end=\"3474\" data-col-size=\"md\"\u003e10 µS\/cm, 84 µS\/cm, 1413 µS\/cm, 12.88 mS\/cm, 111.8 µS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3475\" data-end=\"3520\"\u003e\n\u003ctd data-start=\"3475\" data-end=\"3496\" data-col-size=\"sm\"\u003eCompensation Modes\u003c\/td\u003e\n\u003ctd data-start=\"3496\" data-end=\"3520\" data-col-size=\"md\"\u003eLinear or Pure Water\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3521\" data-end=\"3545\"\u003e\n\u003ctd data-start=\"3521\" data-end=\"3533\" data-col-size=\"sm\"\u003eTDS Range\u003c\/td\u003e\n\u003ctd data-start=\"3533\" data-end=\"3545\" data-col-size=\"md\"\u003e0–10 ppt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3546\" data-end=\"3579\"\u003e\n\u003ctd data-start=\"3546\" data-end=\"3561\" data-col-size=\"sm\"\u003eTDS Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"3561\" data-end=\"3579\" data-col-size=\"md\"\u003e±1% Full Scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3580\" data-end=\"3604\"\u003e\n\u003ctd data-start=\"3580\" data-end=\"3593\" data-col-size=\"sm\"\u003eTDS Factor\u003c\/td\u003e\n\u003ctd data-start=\"3593\" data-end=\"3604\" data-col-size=\"md\"\u003e0.0–1.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3605\" data-end=\"3634\"\u003e\n\u003ctd data-start=\"3605\" data-end=\"3622\" data-col-size=\"sm\"\u003eSalinity Range\u003c\/td\u003e\n\u003ctd data-start=\"3622\" data-end=\"3634\" data-col-size=\"md\"\u003e0–80 ppt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3635\" data-end=\"3673\"\u003e\n\u003ctd data-start=\"3635\" data-end=\"3655\" data-col-size=\"sm\"\u003eSalinity Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"3655\" data-end=\"3673\" data-col-size=\"md\"\u003e±1% Full Scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3674\" data-end=\"3739\"\u003e\n\u003ctd data-start=\"3674\" data-end=\"3690\" data-col-size=\"sm\"\u003eSalinity Mode\u003c\/td\u003e\n\u003ctd data-start=\"3690\" data-end=\"3739\" data-col-size=\"md\"\u003ePractical Salinity (PSU) or Seawater Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3740\" data-end=\"3772\"\u003e\n\u003ctd data-start=\"3740\" data-end=\"3760\" data-col-size=\"sm\"\u003eResistivity Range\u003c\/td\u003e\n\u003ctd data-start=\"3760\" data-end=\"3772\" data-col-size=\"md\"\u003e0–100 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3773\" data-end=\"3816\"\u003e\n\u003ctd data-start=\"3773\" data-end=\"3798\" data-col-size=\"sm\"\u003eResistivity Resolution\u003c\/td\u003e\n\u003ctd data-start=\"3798\" data-end=\"3816\" data-col-size=\"md\"\u003e1 \/ 0.1 \/ 0.01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3817\" data-end=\"3858\"\u003e\n\u003ctd data-start=\"3817\" data-end=\"3840\" data-col-size=\"sm\"\u003eResistivity Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"3840\" data-end=\"3858\" data-col-size=\"md\"\u003e±1% Full Scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3859\" data-end=\"3890\"\u003e\n\u003ctd data-start=\"3859\" data-end=\"3879\" data-col-size=\"sm\"\u003eTemperature Range\u003c\/td\u003e\n\u003ctd data-start=\"3879\" data-end=\"3890\" data-col-size=\"md\"\u003e0–100°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3891\" data-end=\"3941\"\u003e\n\u003ctd data-start=\"3891\" data-end=\"3918\" data-col-size=\"sm\"\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd data-start=\"3918\" data-end=\"3941\" data-col-size=\"md\"\u003eAutomatic or Manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3942\" data-end=\"3975\"\u003e\n\u003ctd data-start=\"3942\" data-end=\"3965\" data-col-size=\"sm\"\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3965\" data-end=\"3975\"\u003e±0.5°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3976\" data-end=\"4020\"\u003e\n\u003ctd data-start=\"3976\" data-end=\"3996\" data-col-size=\"sm\"\u003eAuto-Off Function\u003c\/td\u003e\n\u003ctd data-start=\"3996\" data-end=\"4020\" data-col-size=\"md\"\u003e10 \/ 20 \/ 30 Minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4021\" data-end=\"4057\"\u003e\n\u003ctd data-start=\"4021\" data-end=\"4050\" data-col-size=\"sm\"\u003eReset \u0026amp; Auto Hold Function\u003c\/td\u003e\n\u003ctd data-start=\"4050\" data-end=\"4057\" data-col-size=\"md\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4058\" data-end=\"4097\"\u003e\n\u003ctd data-start=\"4058\" data-end=\"4080\" data-col-size=\"sm\"\u003eElectrode Diagnosis\u003c\/td\u003e\n\u003ctd data-start=\"4080\" data-end=\"4097\" data-col-size=\"md\"\u003eSlope, Offset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4098\" data-end=\"4148\"\u003e\n\u003ctd data-start=\"4098\" data-end=\"4121\" data-col-size=\"sm\"\u003eStability Conditions\u003c\/td\u003e\n\u003ctd data-start=\"4121\" data-end=\"4148\" data-col-size=\"md\"\u003eHigh or Low, Selectable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4149\" data-end=\"4192\"\u003e\n\u003ctd data-start=\"4149\" data-end=\"4176\" data-col-size=\"sm\"\u003eCalibration Due Reminder\u003c\/td\u003e\n\u003ctd data-start=\"4176\" data-end=\"4192\" data-col-size=\"md\"\u003e1 to 30 Days\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4193\" data-end=\"4236\"\u003e\n\u003ctd data-start=\"4193\" data-end=\"4202\" data-col-size=\"sm\"\u003eMemory\u003c\/td\u003e\n\u003ctd data-start=\"4202\" data-end=\"4236\" data-col-size=\"md\"\u003e500 Data Sets with Date \u0026amp; Time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4237\" data-end=\"4272\"\u003e\n\u003ctd data-start=\"4237\" data-end=\"4249\" data-col-size=\"sm\"\u003eConnector\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"4249\" data-end=\"4272\"\u003eBNC 6-Pin Connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4273\" data-end=\"4316\"\u003e\n\u003ctd data-start=\"4273\" data-end=\"4294\" data-col-size=\"sm\"\u003eDimensions (L×W×H)\u003c\/td\u003e\n\u003ctd data-start=\"4294\" data-end=\"4316\" data-col-size=\"md\"\u003e310 × 250 × 190 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4317\" data-end=\"4334\"\u003e\n\u003ctd data-start=\"4317\" data-end=\"4326\" data-col-size=\"sm\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-start=\"4326\" data-end=\"4334\" data-col-size=\"md\"\u003e2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 data-start=\"4336\" data-end=\"4351\"\u003eApplications\u003c\/h3\u003e\n\u003cp data-start=\"4353\" data-end=\"4635\"\u003eWater and wastewater analysis\u003cbr data-start=\"4382\" data-end=\"4385\"\u003eEnvironmental monitoring laboratories\u003cbr data-start=\"4422\" data-end=\"4425\"\u003ePharmaceutical and chemical testing\u003cbr data-start=\"4460\" data-end=\"4463\"\u003eRO and purified water systems\u003cbr data-start=\"4492\" data-end=\"4495\"\u003eFood and beverage quality control\u003cbr data-start=\"4528\" data-end=\"4531\"\u003eAquaculture and seawater testing\u003cbr data-start=\"4563\" data-end=\"4566\"\u003eIndustrial process monitoring\u003cbr data-start=\"4595\" data-end=\"4598\"\u003eEducational and research laboratories\u003c\/p\u003e","brand":"Labman","offers":[{"title":"Default Title","offer_id":49968489038061,"sku":null,"price":50000.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5672\/6765\/files\/LMMP30.webp?v=1778961608"},{"product_id":"water-quality-multiparameter-meter-for-ph-conductivity-do-ion","title":"Water Quality Multiparameter Meter LMMP32 (pH, Conductivity, DO, Ion)","description":"\u003cp data-start=\"253\" data-end=\"676\"\u003eWater Quality Multiparameter LMMP32 is a high-precision laboratory instrument designed for comprehensive water analysis applications including pH, ORP, ion concentration, dissolved oxygen, conductivity, TDS, salinity, resistivity, and temperature measurement. The system combines multiple analytical functions into a single platform for environmental, pharmaceutical, industrial, research, and water treatment laboratories.\u003c\/p\u003e\n\u003cp data-start=\"678\" data-end=\"965\"\u003eThe instrument supports up to 5-point pH calibration with automatic buffer recognition and customizable calibration standards. Automatic electrode diagnostics continuously monitor electrode slope and offset, helping users maintain accurate and reliable measurements throughout operation.\u003c\/p\u003e\n\u003cp data-start=\"967\" data-end=\"1288\"\u003eLMMP32 provides advanced conductivity and TDS analysis with selectable compensation modes, cell constants, temperature coefficients, and normalization temperature settings. The instrument also supports dissolved oxygen measurement with pressure correction and selectable calibration modes for highly accurate DO analysis.\u003c\/p\u003e\n\u003cp data-start=\"1290\" data-end=\"1566\"\u003eThe multiparameter system offers ion concentration analysis compatible with ion selective electrodes, making it suitable for specialized laboratory testing applications. Automatic temperature compensation ensures stable and repeatable results across varying sample conditions.\u003c\/p\u003e\n\u003cp data-start=\"1568\" data-end=\"1886\"\u003eA large backlit LCD interface displays operational prompts and measured parameters clearly for improved usability. The system includes automatic endpoint detection, auto hold functionality, calibration reminders, and memory storage for up to 500 data sets with date and time records to support GLP-compliant workflows.\u003c\/p\u003e\n\u003cp data-start=\"1888\" data-end=\"2104\"\u003eLMMP32 is suitable for water quality laboratories, environmental monitoring, pharmaceutical analysis, wastewater treatment, aquaculture, food processing, educational institutions, and industrial process applications.\u003c\/p\u003e\n\u003ch3 data-start=\"2106\" data-end=\"2121\"\u003eKey Features\u003c\/h3\u003e\n\u003cp data-start=\"2123\" data-end=\"2824\"\u003epH, ORP, ion, conductivity, TDS, salinity, resistivity, DO, and temperature measurement\u003cbr data-start=\"2210\" data-end=\"2213\"\u003eUp to 5-point pH calibration with auto buffer recognition\u003cbr data-start=\"2270\" data-end=\"2273\"\u003eDissolved oxygen measurement with pressure correction\u003cbr data-start=\"2326\" data-end=\"2329\"\u003eIon analysis using ion selective electrodes\u003cbr data-start=\"2372\" data-end=\"2375\"\u003eAutomatic temperature compensation\u003cbr data-start=\"2409\" data-end=\"2412\"\u003eAutomatic endpoint detection and auto hold function\u003cbr data-start=\"2463\" data-end=\"2466\"\u003eAutomatic electrode diagnosis with slope and offset display\u003cbr data-start=\"2525\" data-end=\"2528\"\u003eSelectable conductivity compensation modes\u003cbr data-start=\"2570\" data-end=\"2573\"\u003eSalinity measurement in PSU or seawater standards\u003cbr data-start=\"2622\" data-end=\"2625\"\u003eLarge backlit LCD display with operational guidance\u003cbr data-start=\"2676\" data-end=\"2679\"\u003eMemory storage for up to 500 data sets\u003cbr data-start=\"2717\" data-end=\"2720\"\u003eCalibration due reminder and stability selection\u003cbr data-start=\"2768\" data-end=\"2771\"\u003eSuitable for laboratory and industrial water analysis\u003c\/p\u003e\n\u003ch3 data-start=\"2826\" data-end=\"2853\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"2855\" data-end=\"4744\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"2855\" data-end=\"2884\"\u003e\n\u003ctr data-start=\"2855\" data-end=\"2884\"\u003e\n\u003cth data-start=\"2855\" data-end=\"2867\" data-col-size=\"sm\" class=\"\"\u003eParameter\u003c\/th\u003e\n\u003cth data-start=\"2867\" data-end=\"2884\" data-col-size=\"md\" class=\"\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"2899\" data-end=\"4744\"\u003e\n\u003ctr data-start=\"2899\" data-end=\"2933\"\u003e\n\u003ctd data-start=\"2899\" data-end=\"2910\" data-col-size=\"sm\"\u003epH Range\u003c\/td\u003e\n\u003ctd data-start=\"2910\" data-end=\"2933\" data-col-size=\"md\"\u003e-2.000 to 20.000 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2934\" data-end=\"2973\"\u003e\n\u003ctd data-start=\"2934\" data-end=\"2950\" data-col-size=\"sm\"\u003epH Resolution\u003c\/td\u003e\n\u003ctd data-start=\"2950\" data-end=\"2973\" data-col-size=\"md\"\u003e0.001, 0.01, 0.1 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2974\" data-end=\"3001\"\u003e\n\u003ctd data-start=\"2974\" data-end=\"2988\" data-col-size=\"sm\"\u003epH Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"2988\" data-end=\"3001\" data-col-size=\"md\"\u003e±0.002 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3002\" data-end=\"3044\"\u003e\n\u003ctd data-start=\"3002\" data-end=\"3026\" data-col-size=\"sm\"\u003epH Calibration Points\u003c\/td\u003e\n\u003ctd data-start=\"3026\" data-end=\"3044\" data-col-size=\"md\"\u003eUp to 5 Points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3045\" data-end=\"3097\"\u003e\n\u003ctd data-start=\"3045\" data-end=\"3065\" data-col-size=\"sm\"\u003epH Buffer Options\u003c\/td\u003e\n\u003ctd data-start=\"3065\" data-end=\"3097\" data-col-size=\"md\"\u003eUSA, NIST, DIN, User Defined\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3098\" data-end=\"3127\"\u003e\n\u003ctd data-start=\"3098\" data-end=\"3110\" data-col-size=\"sm\"\u003eORP Range\u003c\/td\u003e\n\u003ctd data-start=\"3110\" data-end=\"3127\" data-col-size=\"md\"\u003e0 to ±1999 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3128\" data-end=\"3159\"\u003e\n\u003ctd data-start=\"3128\" data-end=\"3145\" data-col-size=\"sm\"\u003eORP Resolution\u003c\/td\u003e\n\u003ctd data-start=\"3145\" data-end=\"3159\" data-col-size=\"md\"\u003e0.1 \/ 1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3160\" data-end=\"3186\"\u003e\n\u003ctd data-start=\"3160\" data-end=\"3175\" data-col-size=\"sm\"\u003eORP Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"3175\" data-end=\"3186\" data-col-size=\"md\"\u003e±0.2 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3187\" data-end=\"3216\"\u003e\n\u003ctd data-start=\"3187\" data-end=\"3199\" data-col-size=\"sm\"\u003eIon Range\u003c\/td\u003e\n\u003ctd data-start=\"3199\" data-end=\"3216\" data-col-size=\"md\"\u003e0.00 to 19999\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3217\" data-end=\"3254\"\u003e\n\u003ctd data-start=\"3217\" data-end=\"3234\" data-col-size=\"sm\"\u003eIon Resolution\u003c\/td\u003e\n\u003ctd data-start=\"3234\" data-end=\"3254\" data-col-size=\"md\"\u003e0.001, 0.01, 0.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3255\" data-end=\"3295\"\u003e\n\u003ctd data-start=\"3255\" data-end=\"3270\" data-col-size=\"sm\"\u003eIon Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"3270\" data-end=\"3295\" data-col-size=\"md\"\u003e±0.5%, ±1% Full Scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3296\" data-end=\"3332\"\u003e\n\u003ctd data-start=\"3296\" data-end=\"3317\" data-col-size=\"sm\"\u003eConductivity Range\u003c\/td\u003e\n\u003ctd data-start=\"3317\" data-end=\"3332\" data-col-size=\"md\"\u003e0–200 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3333\" data-end=\"3377\"\u003e\n\u003ctd data-start=\"3333\" data-end=\"3359\" data-col-size=\"sm\"\u003eConductivity Resolution\u003c\/td\u003e\n\u003ctd data-start=\"3359\" data-end=\"3377\" data-col-size=\"md\"\u003e0.01 \/ 0.1 \/ 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3378\" data-end=\"3422\"\u003e\n\u003ctd data-start=\"3378\" data-end=\"3402\" data-col-size=\"sm\"\u003eConductivity Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"3402\" data-end=\"3422\" data-col-size=\"md\"\u003e±0.5% Full Scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3423\" data-end=\"3468\"\u003e\n\u003ctd data-start=\"3423\" data-end=\"3439\" data-col-size=\"sm\"\u003eCell Constant\u003c\/td\u003e\n\u003ctd data-start=\"3439\" data-end=\"3468\" data-col-size=\"md\"\u003e0.1 \/ 1 \/ 10 User Defined\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3469\" data-end=\"3515\"\u003e\n\u003ctd data-start=\"3469\" data-end=\"3495\" data-col-size=\"sm\"\u003eTemperature Coefficient\u003c\/td\u003e\n\u003ctd data-start=\"3495\" data-end=\"3515\" data-col-size=\"md\"\u003e0.0–10.0% per °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3516\" data-end=\"3568\"\u003e\n\u003ctd data-start=\"3516\" data-end=\"3550\" data-col-size=\"sm\"\u003eConductivity Calibration Points\u003c\/td\u003e\n\u003ctd data-start=\"3550\" data-end=\"3568\" data-col-size=\"md\"\u003eUp to 5 Points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3569\" data-end=\"3653\"\u003e\n\u003ctd data-start=\"3569\" data-end=\"3593\" data-col-size=\"sm\"\u003eCalibration Solutions\u003c\/td\u003e\n\u003ctd data-start=\"3593\" data-end=\"3653\" data-col-size=\"md\"\u003e10 µS\/cm, 84 µS\/cm, 1413 µS\/cm, 12.88 mS\/cm, 111.8 µS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3654\" data-end=\"3699\"\u003e\n\u003ctd data-start=\"3654\" data-end=\"3675\" data-col-size=\"sm\"\u003eCompensation Modes\u003c\/td\u003e\n\u003ctd data-start=\"3675\" data-end=\"3699\" data-col-size=\"md\"\u003eLinear or Pure Water\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3700\" data-end=\"3724\"\u003e\n\u003ctd data-start=\"3700\" data-end=\"3712\" data-col-size=\"sm\"\u003eTDS Range\u003c\/td\u003e\n\u003ctd data-start=\"3712\" data-end=\"3724\" data-col-size=\"md\"\u003e0–10 ppt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3725\" data-end=\"3760\"\u003e\n\u003ctd data-start=\"3725\" data-end=\"3742\" data-col-size=\"sm\"\u003eTDS Resolution\u003c\/td\u003e\n\u003ctd data-start=\"3742\" data-end=\"3760\" data-col-size=\"md\"\u003e0.01 \/ 0.1 \/ 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3761\" data-end=\"3794\"\u003e\n\u003ctd data-start=\"3761\" data-end=\"3776\" data-col-size=\"sm\"\u003eTDS Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"3776\" data-end=\"3794\" data-col-size=\"md\"\u003e±1% Full Scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3795\" data-end=\"3819\"\u003e\n\u003ctd data-start=\"3795\" data-end=\"3808\" data-col-size=\"sm\"\u003eTDS Factor\u003c\/td\u003e\n\u003ctd data-start=\"3808\" data-end=\"3819\" data-col-size=\"md\"\u003e0.0–1.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3820\" data-end=\"3849\"\u003e\n\u003ctd data-start=\"3820\" data-end=\"3837\" data-col-size=\"sm\"\u003eSalinity Range\u003c\/td\u003e\n\u003ctd data-start=\"3837\" data-end=\"3849\" data-col-size=\"md\"\u003e0–80 ppt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3850\" data-end=\"3888\"\u003e\n\u003ctd data-start=\"3850\" data-end=\"3870\" data-col-size=\"sm\"\u003eSalinity Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"3870\" data-end=\"3888\" data-col-size=\"md\"\u003e±1% Full Scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3889\" data-end=\"3954\"\u003e\n\u003ctd data-start=\"3889\" data-end=\"3905\" data-col-size=\"sm\"\u003eSalinity Mode\u003c\/td\u003e\n\u003ctd data-start=\"3905\" data-end=\"3954\" data-col-size=\"md\"\u003ePractical Salinity (PSU) or Seawater Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3955\" data-end=\"3987\"\u003e\n\u003ctd data-start=\"3955\" data-end=\"3975\" data-col-size=\"sm\"\u003eResistivity Range\u003c\/td\u003e\n\u003ctd data-start=\"3975\" data-end=\"3987\" data-col-size=\"md\"\u003e0–100 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3988\" data-end=\"4031\"\u003e\n\u003ctd data-start=\"3988\" data-end=\"4013\" data-col-size=\"sm\"\u003eResistivity Resolution\u003c\/td\u003e\n\u003ctd data-start=\"4013\" data-end=\"4031\" data-col-size=\"md\"\u003e1 \/ 0.1 \/ 0.01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4032\" data-end=\"4073\"\u003e\n\u003ctd data-start=\"4032\" data-end=\"4055\" data-col-size=\"sm\"\u003eResistivity Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"4055\" data-end=\"4073\" data-col-size=\"md\"\u003e±1% Full Scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4074\" data-end=\"4107\"\u003e\n\u003ctd data-start=\"4074\" data-end=\"4085\" data-col-size=\"sm\"\u003eDO Range\u003c\/td\u003e\n\u003ctd data-start=\"4085\" data-end=\"4107\" data-col-size=\"md\"\u003e0.00 to 20.00 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4108\" data-end=\"4147\"\u003e\n\u003ctd data-start=\"4108\" data-end=\"4130\" data-col-size=\"sm\"\u003eDO Saturation Range\u003c\/td\u003e\n\u003ctd data-start=\"4130\" data-end=\"4147\" data-col-size=\"md\"\u003e0.0 to 200.0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4148\" data-end=\"4178\"\u003e\n\u003ctd data-start=\"4148\" data-end=\"4164\" data-col-size=\"sm\"\u003eDO Resolution\u003c\/td\u003e\n\u003ctd data-start=\"4164\" data-end=\"4178\" data-col-size=\"md\"\u003e0.01 \/ 0.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4179\" data-end=\"4206\"\u003e\n\u003ctd data-start=\"4179\" data-end=\"4193\" data-col-size=\"sm\"\u003eDO Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"4193\" data-end=\"4206\" data-col-size=\"md\"\u003e±0.2 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4207\" data-end=\"4241\"\u003e\n\u003ctd data-start=\"4207\" data-end=\"4224\" data-col-size=\"sm\"\u003eDO Calibration\u003c\/td\u003e\n\u003ctd data-start=\"4224\" data-end=\"4241\" data-col-size=\"md\"\u003e1 or 2 Points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4242\" data-end=\"4285\"\u003e\n\u003ctd data-start=\"4242\" data-end=\"4264\" data-col-size=\"sm\"\u003ePressure Correction\u003c\/td\u003e\n\u003ctd data-start=\"4264\" data-end=\"4285\" data-col-size=\"md\"\u003e60.0 to 112.5 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4286\" data-end=\"4317\"\u003e\n\u003ctd data-start=\"4286\" data-end=\"4306\" data-col-size=\"sm\"\u003eTemperature Range\u003c\/td\u003e\n\u003ctd data-start=\"4306\" data-end=\"4317\" data-col-size=\"md\"\u003e0–100°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4318\" data-end=\"4368\"\u003e\n\u003ctd data-start=\"4318\" data-end=\"4345\" data-col-size=\"sm\"\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd data-start=\"4345\" data-end=\"4368\" data-col-size=\"md\"\u003eAutomatic or Manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4369\" data-end=\"4402\"\u003e\n\u003ctd data-start=\"4369\" data-end=\"4392\" data-col-size=\"sm\"\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"4392\" data-end=\"4402\" data-col-size=\"md\"\u003e±0.5°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4403\" data-end=\"4430\"\u003e\n\u003ctd data-start=\"4403\" data-end=\"4423\" data-col-size=\"sm\"\u003eAuto-Off Function\u003c\/td\u003e\n\u003ctd data-start=\"4423\" data-end=\"4430\" data-col-size=\"md\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4431\" data-end=\"4467\"\u003e\n\u003ctd data-start=\"4431\" data-end=\"4460\" data-col-size=\"sm\"\u003eReset \u0026amp; Auto Hold Function\u003c\/td\u003e\n\u003ctd data-start=\"4460\" data-end=\"4467\" data-col-size=\"md\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4468\" data-end=\"4507\"\u003e\n\u003ctd data-start=\"4468\" data-end=\"4490\" data-col-size=\"sm\"\u003eElectrode Diagnosis\u003c\/td\u003e\n\u003ctd data-start=\"4490\" data-end=\"4507\" data-col-size=\"md\"\u003eSlope, Offset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4508\" data-end=\"4558\"\u003e\n\u003ctd data-start=\"4508\" data-end=\"4531\" data-col-size=\"sm\"\u003eStability Conditions\u003c\/td\u003e\n\u003ctd data-start=\"4531\" data-end=\"4558\" data-col-size=\"md\"\u003eHigh or Low, Selectable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4559\" data-end=\"4602\"\u003e\n\u003ctd data-start=\"4559\" data-end=\"4586\" data-col-size=\"sm\"\u003eCalibration Due Reminder\u003c\/td\u003e\n\u003ctd data-start=\"4586\" data-end=\"4602\" data-col-size=\"md\"\u003e1 to 30 Days\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4603\" data-end=\"4646\"\u003e\n\u003ctd data-start=\"4603\" data-end=\"4612\" data-col-size=\"sm\"\u003eMemory\u003c\/td\u003e\n\u003ctd data-start=\"4612\" data-end=\"4646\" data-col-size=\"md\"\u003e500 Data Sets with Date \u0026amp; Time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4647\" data-end=\"4682\"\u003e\n\u003ctd data-start=\"4647\" data-end=\"4659\" data-col-size=\"sm\"\u003eConnector\u003c\/td\u003e\n\u003ctd data-start=\"4659\" data-end=\"4682\" data-col-size=\"md\"\u003eBNC 6-Pin Connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4683\" data-end=\"4726\"\u003e\n\u003ctd data-start=\"4683\" data-end=\"4704\" data-col-size=\"sm\"\u003eDimensions (L×W×H)\u003c\/td\u003e\n\u003ctd data-start=\"4704\" data-end=\"4726\" data-col-size=\"md\"\u003e310 × 250 × 190 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4727\" data-end=\"4744\"\u003e\n\u003ctd data-start=\"4727\" data-end=\"4736\" data-col-size=\"sm\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-start=\"4736\" data-end=\"4744\" data-col-size=\"md\"\u003e2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 data-start=\"4746\" data-end=\"4761\"\u003eApplications\u003c\/h3\u003e\n\u003cp data-start=\"4763\" data-end=\"5054\"\u003eWater quality and wastewater testing\u003cbr data-start=\"4799\" data-end=\"4802\"\u003eEnvironmental monitoring laboratories\u003cbr data-start=\"4839\" data-end=\"4842\"\u003ePharmaceutical and chemical analysis\u003cbr data-start=\"4878\" data-end=\"4881\"\u003eAquaculture and seawater testing\u003cbr data-start=\"4913\" data-end=\"4916\"\u003eIndustrial process monitoring\u003cbr data-start=\"4945\" data-end=\"4948\"\u003eFood and beverage quality control\u003cbr data-start=\"4981\" data-end=\"4984\"\u003eResearch and educational laboratories\u003cbr data-start=\"5021\" data-end=\"5024\"\u003eRO and purified water analysis\u003c\/p\u003e","brand":"Labman","offers":[{"title":"Default Title","offer_id":49968493068525,"sku":null,"price":68000.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5672\/6765\/files\/LMMP32_2.webp?v=1778961662"},{"product_id":"benchtop-ion-ph-mv-temperature-meter-for-laboratory-analysis","title":"Benchtop ION pH mV Temperature Meter LMION40","description":"\u003cp data-start=\"255\" data-end=\"595\"\u003eBenchtop ION\/pH\/mV\/°C Meter LMION40 is a high-accuracy laboratory instrument designed for ion concentration, pH, ORP, mV, and temperature measurement in research, environmental, industrial, and academic laboratories. The system combines advanced ion analysis with precision pH measurement to support a wide range of analytical applications.\u003c\/p\u003e\n\u003cp data-start=\"597\" data-end=\"914\"\u003eThe instrument supports up to 5-point pH calibration with automatic buffer recognition and selectable international buffer standards including USA, NIST, DIN, and user-defined options. Automatic electrode diagnostics calculate and display electrode slope after calibration to maintain reliable analytical performance.\u003c\/p\u003e\n\u003cp data-start=\"916\" data-end=\"1210\"\u003eLMION40 provides advanced ion concentration analysis with support for ion selective electrodes and multiple concentration units including ppm, mg\/L, mol\/L, and percentage concentration measurements. The system allows 2 to 5-point ion calibration for accurate low-to-high concentration analysis.\u003c\/p\u003e\n\u003cp data-start=\"1212\" data-end=\"1447\"\u003eThe meter also supports ORP and relative mV measurement with selectable calibration and stability conditions. Automatic temperature compensation ensures accurate readings across varying sample temperatures and environmental conditions.\u003c\/p\u003e\n\u003cp data-start=\"1449\" data-end=\"1719\"\u003eA large LCD interface with operational guidance simplifies routine operation and setup. The instrument features automatic endpoint detection, calibration reminders, real-time clock stamping, and internal memory for storing up to 500 data sets with date and time records.\u003c\/p\u003e\n\u003cp data-start=\"1721\" data-end=\"1962\"\u003eLMION40 is suitable for water quality testing, environmental monitoring, chemical laboratories, pharmaceutical analysis, educational institutions, food processing, and ion concentration studies requiring accurate electrochemical measurement.\u003c\/p\u003e\n\u003ch3 data-start=\"1964\" data-end=\"1979\"\u003eKey Features\u003c\/h3\u003e\n\u003cp data-start=\"1981\" data-end=\"2576\"\u003epH, ion concentration, ORP, mV, and temperature measurement\u003cbr data-start=\"2040\" data-end=\"2043\"\u003eHigh-accuracy ion selective electrode analysis\u003cbr data-start=\"2089\" data-end=\"2092\"\u003eUp to 5-point pH and ion calibration\u003cbr data-start=\"2128\" data-end=\"2131\"\u003eAutomatic buffer recognition with multiple standards\u003cbr data-start=\"2183\" data-end=\"2186\"\u003eAutomatic electrode slope calculation and diagnostics\u003cbr data-start=\"2239\" data-end=\"2242\"\u003eAutomatic temperature compensation\u003cbr data-start=\"2276\" data-end=\"2279\"\u003eAutomatic endpoint detection for stable readings\u003cbr data-start=\"2327\" data-end=\"2330\"\u003eSelectable concentration units including ppm and mol\/L\u003cbr data-start=\"2384\" data-end=\"2387\"\u003eUSB communication interface for data transfer\u003cbr data-start=\"2432\" data-end=\"2435\"\u003eMemory storage for up to 500 data sets\u003cbr data-start=\"2473\" data-end=\"2476\"\u003eCalibration due reminder and stability selection\u003cbr data-start=\"2524\" data-end=\"2527\"\u003eSuitable for laboratory and environmental testing\u003c\/p\u003e\n\u003ch3 data-start=\"2578\" data-end=\"2605\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"2607\" data-end=\"3675\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"2607\" data-end=\"2636\"\u003e\n\u003ctr data-start=\"2607\" data-end=\"2636\"\u003e\n\u003cth data-start=\"2607\" data-end=\"2619\" data-col-size=\"sm\" class=\"\"\u003eParameter\u003c\/th\u003e\n\u003cth data-start=\"2619\" data-end=\"2636\" data-col-size=\"md\" class=\"\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"2651\" data-end=\"3675\"\u003e\n\u003ctr data-start=\"2651\" data-end=\"2685\"\u003e\n\u003ctd data-start=\"2651\" data-end=\"2662\" data-col-size=\"sm\"\u003epH Range\u003c\/td\u003e\n\u003ctd data-start=\"2662\" data-end=\"2685\" data-col-size=\"md\"\u003e-2.000 to 20.000 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2686\" data-end=\"2713\"\u003e\n\u003ctd data-start=\"2686\" data-end=\"2700\" data-col-size=\"sm\"\u003epH Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"2700\" data-end=\"2713\" data-col-size=\"md\"\u003e±0.002 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2714\" data-end=\"2753\"\u003e\n\u003ctd data-start=\"2714\" data-end=\"2730\" data-col-size=\"sm\"\u003epH Resolution\u003c\/td\u003e\n\u003ctd data-start=\"2730\" data-end=\"2753\" data-col-size=\"md\"\u003e0.001, 0.01, 0.1 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2754\" data-end=\"2796\"\u003e\n\u003ctd data-start=\"2754\" data-end=\"2778\" data-col-size=\"sm\"\u003epH Calibration Points\u003c\/td\u003e\n\u003ctd data-start=\"2778\" data-end=\"2796\" data-col-size=\"md\"\u003eUp to 5 Points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2797\" data-end=\"2855\"\u003e\n\u003ctd data-start=\"2797\" data-end=\"2823\" data-col-size=\"sm\"\u003eIon Concentration Range\u003c\/td\u003e\n\u003ctd data-start=\"2823\" data-end=\"2855\" data-col-size=\"md\"\u003e0.001–19999 ppm, mg\/L, mol\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2856\" data-end=\"2931\"\u003e\n\u003ctd data-start=\"2856\" data-end=\"2871\" data-col-size=\"sm\"\u003eIon Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"2871\" data-end=\"2931\" data-col-size=\"md\"\u003e±0.5% Full Scale (Monovalent), ±1% Full Scale (Divalent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2932\" data-end=\"2972\"\u003e\n\u003ctd data-start=\"2932\" data-end=\"2949\" data-col-size=\"sm\"\u003eIon Resolution\u003c\/td\u003e\n\u003ctd data-start=\"2949\" data-end=\"2972\" data-col-size=\"md\"\u003e0.001, 0.01, 0.1, 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2973\" data-end=\"3016\"\u003e\n\u003ctd data-start=\"2973\" data-end=\"2998\" data-col-size=\"sm\"\u003eIon Calibration Points\u003c\/td\u003e\n\u003ctd data-start=\"2998\" data-end=\"3016\" data-col-size=\"md\"\u003eUp to 5 Points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3017\" data-end=\"3042\"\u003e\n\u003ctd data-start=\"3017\" data-end=\"3028\" data-col-size=\"sm\"\u003emV Range\u003c\/td\u003e\n\u003ctd data-start=\"3028\" data-end=\"3042\" data-col-size=\"md\"\u003e±1999.9 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3043\" data-end=\"3068\"\u003e\n\u003ctd data-start=\"3043\" data-end=\"3057\" data-col-size=\"sm\"\u003emV Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"3057\" data-end=\"3068\" data-col-size=\"md\"\u003e±0.2 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3069\" data-end=\"3099\"\u003e\n\u003ctd data-start=\"3069\" data-end=\"3085\" data-col-size=\"sm\"\u003emV Resolution\u003c\/td\u003e\n\u003ctd data-start=\"3085\" data-end=\"3099\" data-col-size=\"md\"\u003e0.1 \/ 1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3100\" data-end=\"3128\"\u003e\n\u003ctd data-start=\"3100\" data-end=\"3117\" data-col-size=\"sm\"\u003emV Calibration\u003c\/td\u003e\n\u003ctd data-start=\"3117\" data-end=\"3128\" data-col-size=\"md\"\u003e1 Point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3129\" data-end=\"3160\"\u003e\n\u003ctd data-start=\"3129\" data-end=\"3149\" data-col-size=\"sm\"\u003eTemperature Range\u003c\/td\u003e\n\u003ctd data-start=\"3149\" data-end=\"3160\" data-col-size=\"md\"\u003e0–105°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3161\" data-end=\"3194\"\u003e\n\u003ctd data-start=\"3161\" data-end=\"3184\" data-col-size=\"sm\"\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"3184\" data-end=\"3194\" data-col-size=\"md\"\u003e±0.5°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3195\" data-end=\"3229\"\u003e\n\u003ctd data-start=\"3195\" data-end=\"3220\" data-col-size=\"sm\"\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd data-start=\"3220\" data-end=\"3229\" data-col-size=\"md\"\u003e0.1°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3230\" data-end=\"3282\"\u003e\n\u003ctd data-start=\"3230\" data-end=\"3250\" data-col-size=\"sm\"\u003epH Buffer Options\u003c\/td\u003e\n\u003ctd data-start=\"3250\" data-end=\"3282\" data-col-size=\"md\"\u003eUSA, NIST, DIN, User Defined\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3283\" data-end=\"3326\"\u003e\n\u003ctd data-start=\"3283\" data-end=\"3292\" data-col-size=\"sm\"\u003eMemory\u003c\/td\u003e\n\u003ctd data-start=\"3292\" data-end=\"3326\" data-col-size=\"md\"\u003e500 Data Sets with Date \u0026amp; Time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3327\" data-end=\"3367\"\u003e\n\u003ctd data-start=\"3327\" data-end=\"3336\" data-col-size=\"sm\"\u003eOutput\u003c\/td\u003e\n\u003ctd data-start=\"3336\" data-end=\"3367\" data-col-size=\"md\"\u003eUSB Communication Interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3368\" data-end=\"3387\"\u003e\n\u003ctd data-start=\"3368\" data-end=\"3380\" data-col-size=\"sm\"\u003eConnector\u003c\/td\u003e\n\u003ctd data-start=\"3380\" data-end=\"3387\" data-col-size=\"md\"\u003eBNC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3388\" data-end=\"3418\"\u003e\n\u003ctd data-start=\"3388\" data-end=\"3404\" data-col-size=\"sm\"\u003eHold Function\u003c\/td\u003e\n\u003ctd data-start=\"3404\" data-end=\"3418\" data-col-size=\"md\"\u003eSelectable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3419\" data-end=\"3469\"\u003e\n\u003ctd data-start=\"3419\" data-end=\"3446\" data-col-size=\"sm\"\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd data-start=\"3446\" data-end=\"3469\" data-col-size=\"md\"\u003eAutomatic or Manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3470\" data-end=\"3520\"\u003e\n\u003ctd data-start=\"3470\" data-end=\"3493\" data-col-size=\"sm\"\u003eStability Conditions\u003c\/td\u003e\n\u003ctd data-start=\"3493\" data-end=\"3520\" data-col-size=\"md\"\u003eLow or High, Selectable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3521\" data-end=\"3564\"\u003e\n\u003ctd data-start=\"3521\" data-end=\"3548\" data-col-size=\"sm\"\u003eCalibration Due Reminder\u003c\/td\u003e\n\u003ctd data-start=\"3548\" data-end=\"3564\" data-col-size=\"md\"\u003e1 to 31 Days\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3565\" data-end=\"3613\"\u003e\n\u003ctd data-start=\"3565\" data-end=\"3580\" data-col-size=\"sm\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd data-start=\"3580\" data-end=\"3613\" data-col-size=\"md\"\u003eDC Adaptor, AC 220V \/ 50–60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3614\" data-end=\"3657\"\u003e\n\u003ctd data-start=\"3614\" data-end=\"3635\" data-col-size=\"sm\"\u003eDimensions (L×W×H)\u003c\/td\u003e\n\u003ctd data-start=\"3635\" data-end=\"3657\" data-col-size=\"md\"\u003e310 × 255 × 190 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3658\" data-end=\"3675\"\u003e\n\u003ctd data-start=\"3658\" data-end=\"3667\" data-col-size=\"sm\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-start=\"3667\" data-end=\"3675\" data-col-size=\"md\"\u003e2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 data-start=\"3677\" data-end=\"3692\"\u003eApplications\u003c\/h3\u003e\n\u003cp data-start=\"3694\" data-end=\"3951\"\u003eIon concentration analysis\u003cbr data-start=\"3720\" data-end=\"3723\"\u003eWater quality and environmental testing\u003cbr data-start=\"3762\" data-end=\"3765\"\u003eChemical and pharmaceutical laboratories\u003cbr data-start=\"3805\" data-end=\"3808\"\u003eSwimming pool and wastewater analysis\u003cbr data-start=\"3845\" data-end=\"3848\"\u003eEducational and research institutions\u003cbr data-start=\"3885\" data-end=\"3888\"\u003eFood and beverage testing\u003cbr data-start=\"3913\" data-end=\"3916\"\u003eIndustrial electrochemical analysis\u003c\/p\u003e","brand":"Labman","offers":[{"title":"Default Title","offer_id":49968495231213,"sku":null,"price":50000.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5672\/6765\/files\/LMION40.jpg?v=1778961731"},{"product_id":"benchtop-dissolved-oxygen-meter-for-water-quality-analysis","title":"Benchtop Dissolved Oxygen Meter LMDO50","description":"\u003cp data-start=\"269\" data-end=\"606\"\u003eBenchtop Dissolved Oxygen Meter LMDO50 is a professional laboratory instrument designed for accurate measurement of dissolved oxygen concentration and oxygen saturation in water samples. The system is suitable for environmental monitoring, water treatment, aquaculture, research laboratories, and industrial quality control applications.\u003c\/p\u003e\n\u003cp data-start=\"608\" data-end=\"895\"\u003eThe instrument uses a polarographic dissolved oxygen sensor for stable and reliable DO measurement across a wide operating range. It supports dissolved oxygen measurement in mg\/L, ppm, and percentage saturation modes, allowing flexibility for different laboratory and field applications.\u003c\/p\u003e\n\u003cp data-start=\"897\" data-end=\"1160\"\u003eLMDO50 features automatic temperature compensation to ensure highly accurate readings under varying sample temperatures. The system also supports manual salinity and barometric pressure correction, improving measurement reliability for different water conditions.\u003c\/p\u003e\n\u003cp data-start=\"1162\" data-end=\"1391\"\u003eThe meter provides 1 or 2-point automatic calibration using air-saturated water or zero oxygen solution for easy and accurate setup. Automatic endpoint detection freezes stable readings for simplified data recording and analysis.\u003c\/p\u003e\n\u003cp data-start=\"1393\" data-end=\"1683\"\u003eA large LCD interface displays measured parameters clearly and includes operational guidance for user convenience. The system also includes calibration reminders, selectable stability modes, hold functionality, and internal memory for storing up to 500 data sets with date and time records.\u003c\/p\u003e\n\u003cp data-start=\"1685\" data-end=\"1934\"\u003eLMDO50 is ideal for water quality testing laboratories, environmental studies, wastewater treatment plants, aquaculture facilities, educational institutions, and industrial process monitoring applications requiring precise dissolved oxygen analysis.\u003c\/p\u003e\n\u003ch3 data-start=\"1936\" data-end=\"1951\"\u003eKey Features\u003c\/h3\u003e\n\u003cp data-start=\"1953\" data-end=\"2469\"\u003eDissolved oxygen concentration and saturation measurement\u003cbr data-start=\"2010\" data-end=\"2013\"\u003eMeasurement in mg\/L, ppm, or % saturation\u003cbr data-start=\"2054\" data-end=\"2057\"\u003ePolarographic dissolved oxygen sensor\u003cbr data-start=\"2094\" data-end=\"2097\"\u003eAutomatic temperature compensation\u003cbr data-start=\"2131\" data-end=\"2134\"\u003eSalinity and barometric pressure correction\u003cbr data-start=\"2177\" data-end=\"2180\"\u003e1 or 2-point automatic calibration\u003cbr data-start=\"2214\" data-end=\"2217\"\u003eAutomatic endpoint detection and hold function\u003cbr data-start=\"2263\" data-end=\"2266\"\u003eSelectable stability conditions\u003cbr data-start=\"2297\" data-end=\"2300\"\u003eLarge LCD display with operational guidance\u003cbr data-start=\"2343\" data-end=\"2346\"\u003eMemory storage for up to 500 data sets\u003cbr data-start=\"2384\" data-end=\"2387\"\u003eUSB communication interface\u003cbr data-start=\"2414\" data-end=\"2417\"\u003eSuitable for laboratory and industrial water testing\u003c\/p\u003e\n\u003ch3 data-start=\"2471\" data-end=\"2498\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"2500\" data-end=\"3302\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"2500\" data-end=\"2529\"\u003e\n\u003ctr data-start=\"2500\" data-end=\"2529\"\u003e\n\u003cth data-start=\"2500\" data-end=\"2512\" data-col-size=\"sm\" class=\"\"\u003eParameter\u003c\/th\u003e\n\u003cth data-start=\"2512\" data-end=\"2529\" data-col-size=\"sm\" class=\"\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"2544\" data-end=\"3302\"\u003e\n\u003ctr data-start=\"2544\" data-end=\"2595\"\u003e\n\u003ctd data-start=\"2544\" data-end=\"2569\" data-col-size=\"sm\"\u003eDissolved Oxygen Range\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2569\" data-end=\"2595\"\u003e0.00–20.00 mg\/L or ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2596\" data-end=\"2630\"\u003e\n\u003ctd data-start=\"2596\" data-end=\"2612\" data-col-size=\"sm\"\u003eDO Resolution\u003c\/td\u003e\n\u003ctd data-start=\"2612\" data-end=\"2630\" data-col-size=\"sm\"\u003e0.1 \/ 0.01 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2631\" data-end=\"2665\"\u003e\n\u003ctd data-start=\"2631\" data-end=\"2645\" data-col-size=\"sm\"\u003eDO Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"2645\" data-end=\"2665\" data-col-size=\"sm\"\u003e±0.2 mg\/L or ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2666\" data-end=\"2706\"\u003e\n\u003ctd data-start=\"2666\" data-end=\"2692\" data-col-size=\"sm\"\u003eOxygen Saturation Range\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2692\" data-end=\"2706\"\u003e0.0–200.0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2707\" data-end=\"2743\"\u003e\n\u003ctd data-start=\"2707\" data-end=\"2731\" data-col-size=\"sm\"\u003eSaturation Resolution\u003c\/td\u003e\n\u003ctd data-start=\"2731\" data-end=\"2743\" data-col-size=\"sm\"\u003e0.1 \/ 1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2744\" data-end=\"2775\"\u003e\n\u003ctd data-start=\"2744\" data-end=\"2766\" data-col-size=\"sm\"\u003eSaturation Accuracy\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2766\" data-end=\"2775\"\u003e±2.0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2776\" data-end=\"2806\"\u003e\n\u003ctd data-start=\"2776\" data-end=\"2796\" data-col-size=\"sm\"\u003eTemperature Range\u003c\/td\u003e\n\u003ctd data-start=\"2796\" data-end=\"2806\" data-col-size=\"sm\"\u003e0–50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2807\" data-end=\"2840\"\u003e\n\u003ctd data-start=\"2807\" data-end=\"2830\" data-col-size=\"sm\"\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2830\" data-end=\"2840\"\u003e±0.5°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2841\" data-end=\"2889\"\u003e\n\u003ctd data-start=\"2841\" data-end=\"2868\" data-col-size=\"sm\"\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2868\" data-end=\"2889\"\u003e0–50°C, Automatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2890\" data-end=\"2924\"\u003e\n\u003ctd data-start=\"2890\" data-end=\"2912\" data-col-size=\"sm\"\u003eSalinity Correction\u003c\/td\u003e\n\u003ctd data-start=\"2912\" data-end=\"2924\" data-col-size=\"sm\"\u003e0–50 g\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2925\" data-end=\"2976\"\u003e\n\u003ctd data-start=\"2925\" data-end=\"2958\" data-col-size=\"sm\"\u003eBarometric Pressure Correction\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2958\" data-end=\"2976\"\u003e60.0–112.5 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2977\" data-end=\"3015\"\u003e\n\u003ctd data-start=\"2977\" data-end=\"2998\" data-col-size=\"sm\"\u003eCalibration Points\u003c\/td\u003e\n\u003ctd data-start=\"2998\" data-end=\"3015\" data-col-size=\"sm\"\u003e1 or 2 Points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3016\" data-end=\"3059\"\u003e\n\u003ctd data-start=\"3016\" data-end=\"3025\" data-col-size=\"sm\"\u003eMemory\u003c\/td\u003e\n\u003ctd data-start=\"3025\" data-end=\"3059\" data-col-size=\"sm\"\u003e500 Data Sets with Date \u0026amp; Time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3060\" data-end=\"3077\"\u003e\n\u003ctd data-start=\"3060\" data-end=\"3070\" data-col-size=\"sm\"\u003eDisplay\u003c\/td\u003e\n\u003ctd data-start=\"3070\" data-end=\"3077\" data-col-size=\"sm\"\u003eLCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3078\" data-end=\"3107\"\u003e\n\u003ctd data-start=\"3078\" data-end=\"3094\" data-col-size=\"sm\"\u003eHold Function\u003c\/td\u003e\n\u003ctd data-start=\"3094\" data-end=\"3107\" data-col-size=\"sm\"\u003eAvailable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3108\" data-end=\"3127\"\u003e\n\u003ctd data-start=\"3108\" data-end=\"3120\" data-col-size=\"sm\"\u003eInterface\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3120\" data-end=\"3127\"\u003eUSB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3128\" data-end=\"3158\"\u003e\n\u003ctd data-start=\"3128\" data-end=\"3140\" data-col-size=\"sm\"\u003eConnector\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3140\" data-end=\"3158\"\u003e6-Pin Mini-DIN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3159\" data-end=\"3191\"\u003e\n\u003ctd data-start=\"3159\" data-end=\"3177\" data-col-size=\"sm\"\u003eStability Modes\u003c\/td\u003e\n\u003ctd data-start=\"3177\" data-end=\"3191\" data-col-size=\"sm\"\u003eLow \/ High\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3192\" data-end=\"3240\"\u003e\n\u003ctd data-start=\"3192\" data-end=\"3207\" data-col-size=\"sm\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd data-start=\"3207\" data-end=\"3240\" data-col-size=\"sm\"\u003eDC Adaptor, AC 220V \/ 50–60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3241\" data-end=\"3284\"\u003e\n\u003ctd data-start=\"3241\" data-end=\"3262\" data-col-size=\"sm\"\u003eDimensions (L×W×H)\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3262\" data-end=\"3284\"\u003e310 × 250 × 190 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3285\" data-end=\"3302\"\u003e\n\u003ctd data-start=\"3285\" data-end=\"3294\" data-col-size=\"sm\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-start=\"3294\" data-end=\"3302\" data-col-size=\"sm\"\u003e2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 data-start=\"3304\" data-end=\"3319\"\u003eApplications\u003c\/h3\u003e\n\u003cp data-start=\"3321\" data-end=\"3535\"\u003eWater quality testing\u003cbr data-start=\"3342\" data-end=\"3345\"\u003eEnvironmental monitoring laboratories\u003cbr data-start=\"3382\" data-end=\"3385\"\u003eAquaculture and fisheries\u003cbr data-start=\"3410\" data-end=\"3413\"\u003eWastewater treatment plants\u003cbr data-start=\"3440\" data-end=\"3443\"\u003eResearch and academic laboratories\u003cbr data-start=\"3477\" data-end=\"3480\"\u003eIndustrial process monitoring\u003cbr data-start=\"3509\" data-end=\"3512\"\u003eDrinking water analysis\u003c\/p\u003e","brand":"Labman","offers":[{"title":"Default Title","offer_id":49968502735085,"sku":null,"price":60000.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5672\/6765\/files\/LMDO50.jpg?v=1778961789"},{"product_id":"water-hardness-meter-for-ion-concentration-analysis","title":"Water Hardness Meter for Ion Concentration Analysis LMHD60","description":"\u003cp data-start=\"245\" data-end=\"610\"\u003eWater Hardness Meter LMHD60 is a precision laboratory instrument designed for accurate water hardness and ion concentration analysis in environmental, industrial, research, and water treatment applications. The system supports advanced ion-selective electrode measurement methods for reliable determination of hardness concentration across a wide measurement range.\u003c\/p\u003e\n\u003cp data-start=\"612\" data-end=\"948\"\u003eThe instrument features a 7-inch TFT display with user-friendly operation and supports 2 to 5-point calibration for both water hardness and ion concentration analysis. Multiple selectable concentration units including mg\/L, ppm, mol\/L, and mmol\/L provide flexibility for various laboratory testing standards and analytical requirements.\u003c\/p\u003e\n\u003cp data-start=\"950\" data-end=\"1261\"\u003eLMHD60 supports multiple ion measurement modes including direct reading, known addition, known subtraction, sample addition, and sample subtraction methods. Electrode management capability allows storage and recall of up to three electrode slopes for improved calibration consistency and operational efficiency.\u003c\/p\u003e\n\u003cp data-start=\"1263\" data-end=\"1607\"\u003eAutomatic temperature compensation ensures accurate measurements over varying sample conditions, while auto-read functionality locks stable measurement endpoints for simplified data recording. The system also includes calibration due reminders, password protection, stability selection, and real-time clock stamping for GLP-compliant workflows.\u003c\/p\u003e\n\u003cp data-start=\"1609\" data-end=\"1849\"\u003eA large internal memory stores up to 1000 data sets, and interval reading data can be transferred to external systems or printers for documentation and reporting purposes. An optional thermal printer is available for direct report printing.\u003c\/p\u003e\n\u003cp data-start=\"1851\" data-end=\"2086\"\u003eLMHD60 is suitable for water quality laboratories, industrial water testing, environmental monitoring, chemical analysis, educational institutions, and research laboratories requiring precise hardness and ion concentration measurement.\u003c\/p\u003e\n\u003ch3 data-start=\"2088\" data-end=\"2103\"\u003eKey Features\u003c\/h3\u003e\n\u003cp data-start=\"2105\" data-end=\"2637\"\u003eWater hardness and ion concentration measurement\u003cbr data-start=\"2153\" data-end=\"2156\"\u003e7-inch TFT color display\u003cbr data-start=\"2180\" data-end=\"2183\"\u003e2 to 5-point calibration capability\u003cbr data-start=\"2218\" data-end=\"2221\"\u003eMultiple concentration units including ppm, mg\/L, mol\/L, and mmol\/L\u003cbr data-start=\"2288\" data-end=\"2291\"\u003eAutomatic temperature compensation\u003cbr data-start=\"2325\" data-end=\"2328\"\u003eSelectable ion measurement methods\u003cbr data-start=\"2362\" data-end=\"2365\"\u003eElectrode slope storage and recall function\u003cbr data-start=\"2408\" data-end=\"2411\"\u003eAuto-read endpoint detection\u003cbr data-start=\"2439\" data-end=\"2442\"\u003ePassword protection and calibration reminder\u003cbr data-start=\"2486\" data-end=\"2489\"\u003eMemory storage for up to 1000 data sets\u003cbr data-start=\"2528\" data-end=\"2531\"\u003eData transfer and optional thermal printer support\u003cbr data-start=\"2581\" data-end=\"2584\"\u003eSuitable for laboratory and industrial water analysis\u003c\/p\u003e\n\u003ch3 data-start=\"2639\" data-end=\"2666\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"2668\" data-end=\"3725\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"2668\" data-end=\"2697\"\u003e\n\u003ctr data-start=\"2668\" data-end=\"2697\"\u003e\n\u003cth data-start=\"2668\" data-end=\"2680\" data-col-size=\"sm\" class=\"\"\u003eParameter\u003c\/th\u003e\n\u003cth data-start=\"2680\" data-end=\"2697\" data-col-size=\"md\" class=\"\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"2712\" data-end=\"3725\"\u003e\n\u003ctr data-start=\"2712\" data-end=\"2757\"\u003e\n\u003ctd data-start=\"2712\" data-end=\"2735\" data-col-size=\"sm\"\u003eWater Hardness Range\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2735\" data-end=\"2757\"\u003e0.05 to 200 mmol\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2758\" data-end=\"2796\"\u003e\n\u003ctd data-start=\"2758\" data-end=\"2784\" data-col-size=\"sm\"\u003eWater Hardness Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"2784\" data-end=\"2796\" data-col-size=\"md\"\u003e±1% F.S.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2797\" data-end=\"2848\"\u003e\n\u003ctd data-start=\"2797\" data-end=\"2825\" data-col-size=\"sm\"\u003eWater Hardness Resolution\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2825\" data-end=\"2848\"\u003e0.001, 0.01, 0.1, 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2849\" data-end=\"2895\"\u003e\n\u003ctd data-start=\"2849\" data-end=\"2878\" data-col-size=\"sm\"\u003eWater Hardness Calibration\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2878\" data-end=\"2895\"\u003e2 to 5 Points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2896\" data-end=\"2969\"\u003e\n\u003ctd data-start=\"2896\" data-end=\"2933\" data-col-size=\"sm\"\u003eWater Hardness Calibration Options\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2933\" data-end=\"2969\"\u003e0.01 \/ 0.1 \/ 1 \/ 10 \/ 100 mmol\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2970\" data-end=\"3004\"\u003e\n\u003ctd data-start=\"2970\" data-end=\"2982\" data-col-size=\"sm\"\u003eIon Range\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2982\" data-end=\"3004\"\u003e0.001–30000 mmol\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3005\" data-end=\"3045\"\u003e\n\u003ctd data-start=\"3005\" data-end=\"3020\" data-col-size=\"sm\"\u003eIon Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"3020\" data-end=\"3045\" data-col-size=\"md\"\u003e±0.5% F.S. \/ ±1% F.S.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3046\" data-end=\"3086\"\u003e\n\u003ctd data-start=\"3046\" data-end=\"3063\" data-col-size=\"sm\"\u003eIon Resolution\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3063\" data-end=\"3086\"\u003e0.001, 0.01, 0.1, 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3087\" data-end=\"3122\"\u003e\n\u003ctd data-start=\"3087\" data-end=\"3105\" data-col-size=\"sm\"\u003eIon Calibration\u003c\/td\u003e\n\u003ctd data-start=\"3105\" data-end=\"3122\" data-col-size=\"md\"\u003e2 to 5 Points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3123\" data-end=\"3208\"\u003e\n\u003ctd data-start=\"3123\" data-end=\"3149\" data-col-size=\"sm\"\u003eIon Calibration Options\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3149\" data-end=\"3208\"\u003e0.001 \/ 0.01 \/ 0.1 \/ 1 \/ 10 \/ 100 \/ 1000 \/ 10000 mmol\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3209\" data-end=\"3257\"\u003e\n\u003ctd data-start=\"3209\" data-end=\"3229\" data-col-size=\"sm\"\u003eMeasurement Units\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3229\" data-end=\"3257\"\u003eppm, mg\/L, mol\/L, mmol\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3258\" data-end=\"3289\"\u003e\n\u003ctd data-start=\"3258\" data-end=\"3278\" data-col-size=\"sm\"\u003eTemperature Range\u003c\/td\u003e\n\u003ctd data-start=\"3278\" data-end=\"3289\" data-col-size=\"md\"\u003e0–105°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3290\" data-end=\"3323\"\u003e\n\u003ctd data-start=\"3290\" data-end=\"3313\" data-col-size=\"sm\"\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3313\" data-end=\"3323\"\u003e±0.5°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3324\" data-end=\"3358\"\u003e\n\u003ctd data-start=\"3324\" data-end=\"3349\" data-col-size=\"sm\"\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3349\" data-end=\"3358\"\u003e0.1°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3359\" data-end=\"3409\"\u003e\n\u003ctd data-start=\"3359\" data-end=\"3386\" data-col-size=\"sm\"\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd data-start=\"3386\" data-end=\"3409\" data-col-size=\"md\"\u003eAutomatic or Manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3410\" data-end=\"3457\"\u003e\n\u003ctd data-start=\"3410\" data-end=\"3428\" data-col-size=\"sm\"\u003eStability Modes\u003c\/td\u003e\n\u003ctd data-start=\"3428\" data-end=\"3457\" data-col-size=\"md\"\u003eStandard or High Accuracy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3458\" data-end=\"3505\"\u003e\n\u003ctd data-start=\"3458\" data-end=\"3482\" data-col-size=\"sm\"\u003eCalibration Due Alarm\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3482\" data-end=\"3505\"\u003e1 to 31 Days or Off\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3506\" data-end=\"3545\"\u003e\n\u003ctd data-start=\"3506\" data-end=\"3528\" data-col-size=\"sm\"\u003ePassword Protection\u003c\/td\u003e\n\u003ctd data-start=\"3528\" data-end=\"3545\" data-col-size=\"md\"\u003eYes, 4 Digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3546\" data-end=\"3573\"\u003e\n\u003ctd data-start=\"3546\" data-end=\"3555\" data-col-size=\"sm\"\u003eMemory\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3555\" data-end=\"3573\"\u003e1000 Data Sets\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3574\" data-end=\"3593\"\u003e\n\u003ctd data-start=\"3574\" data-end=\"3586\" data-col-size=\"sm\"\u003eConnector\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3586\" data-end=\"3593\"\u003eBNC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3594\" data-end=\"3622\"\u003e\n\u003ctd data-start=\"3594\" data-end=\"3604\" data-col-size=\"sm\"\u003eDisplay\u003c\/td\u003e\n\u003ctd data-start=\"3604\" data-end=\"3622\" data-col-size=\"md\"\u003e7-inch TFT LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3623\" data-end=\"3663\"\u003e\n\u003ctd data-start=\"3623\" data-end=\"3638\" data-col-size=\"sm\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd data-start=\"3638\" data-end=\"3663\" data-col-size=\"md\"\u003eDC12V, AC 220V \/ 50Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3664\" data-end=\"3707\"\u003e\n\u003ctd data-start=\"3664\" data-end=\"3685\" data-col-size=\"sm\"\u003eDimensions (L×W×H)\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3685\" data-end=\"3707\"\u003e310 × 250 × 190 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3708\" data-end=\"3725\"\u003e\n\u003ctd data-start=\"3708\" data-end=\"3717\" data-col-size=\"sm\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-start=\"3717\" data-end=\"3725\" data-col-size=\"md\"\u003e2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 data-start=\"3727\" data-end=\"3742\"\u003eApplications\u003c\/h3\u003e\n\u003cp data-start=\"3744\" data-end=\"3991\"\u003eWater hardness testing\u003cbr data-start=\"3766\" data-end=\"3769\"\u003eIndustrial water analysis\u003cbr data-start=\"3794\" data-end=\"3797\"\u003eEnvironmental monitoring laboratories\u003cbr data-start=\"3834\" data-end=\"3837\"\u003eBoiler and cooling water testing\u003cbr data-start=\"3869\" data-end=\"3872\"\u003eChemical and research laboratories\u003cbr data-start=\"3906\" data-end=\"3909\"\u003eEducational institutions\u003cbr data-start=\"3933\" data-end=\"3936\"\u003eWater treatment facilities\u003cbr data-start=\"3962\" data-end=\"3965\"\u003eIon concentration analysis\u003c\/p\u003e","brand":"Labman","offers":[{"title":"Default Title","offer_id":49968506536173,"sku":null,"price":80000.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5672\/6765\/files\/LMHD60.jpg?v=1778962899"},{"product_id":"turbidity-meter-lmtb200-4-5-tft-display-tss-measurement-mode","title":"Turbidity Meter LMTB200 (4.5\" TFT Display, TSS Measurement Mode)","description":"\u003cp data-start=\"261\" data-end=\"594\"\u003eTurbidity Meter LMTB200 is a precision laboratory instrument designed for accurate turbidity and total suspended solids (TSS) measurement in water and wastewater analysis applications. The system combines advanced optical detection with multi-point calibration capability to deliver stable and reliable turbidity measurement results.\u003c\/p\u003e\n\u003cp data-start=\"596\" data-end=\"848\"\u003eThe instrument supports turbidity measurement from 1 to 2000 NTU with selectable turbidity units including NTU, FNU, EBC, and ASBC. A built-in TSS conversion mode enables accurate suspended solids analysis for industrial and environmental applications.\u003c\/p\u003e\n\u003cp data-start=\"850\" data-end=\"1121\"\u003eLMTB200 features a 4.5-inch TFT display with user-friendly menu navigation and operational guidance for simplified testing procedures. The system supports 2 to 7-point calibration using Formazin standards to improve measurement accuracy across different turbidity ranges.\u003c\/p\u003e\n\u003cp data-start=\"1123\" data-end=\"1384\"\u003eAn infrared-emitting diode operating at 850 nm combined with a silicon photodiode detector ensures stable optical performance with low stray light interference. Continuous measurement mode allows indexing and matching of sample vials for improved repeatability.\u003c\/p\u003e\n\u003cp data-start=\"1386\" data-end=\"1580\"\u003eThe meter includes password protection, hold functionality, automatic reset options, and internal memory capable of storing up to 200 data sets for laboratory record management and traceability.\u003c\/p\u003e\n\u003cp data-start=\"1582\" data-end=\"1795\"\u003eLMTB200 is suitable for industrial wastewater plants, municipal water treatment facilities, environmental laboratories, food and beverage testing, academic research, and industrial process monitoring applications.\u003c\/p\u003e\n\u003ch3 data-start=\"1797\" data-end=\"1812\"\u003eKey Features\u003c\/h3\u003e\n\u003cp data-start=\"1814\" data-end=\"2376\"\u003eTurbidity and TSS measurement capability\u003cbr data-start=\"1854\" data-end=\"1857\"\u003eMeasurement range from 1 to 2000 NTU\u003cbr data-start=\"1893\" data-end=\"1896\"\u003eSelectable turbidity units including NTU, FNU, EBC, and ASBC\u003cbr data-start=\"1956\" data-end=\"1959\"\u003e2 to 7-point calibration using Formazin standards\u003cbr data-start=\"2008\" data-end=\"2011\"\u003e4.5-inch TFT display with menu-based operation\u003cbr data-start=\"2057\" data-end=\"2060\"\u003eInfrared LED light source at 850 nm\u003cbr data-start=\"2095\" data-end=\"2098\"\u003eSilicon photodiode detector for stable measurement\u003cbr data-start=\"2148\" data-end=\"2151\"\u003eContinuous measurement mode for vial indexing\u003cbr data-start=\"2196\" data-end=\"2199\"\u003ePassword protection for calibration and settings\u003cbr data-start=\"2247\" data-end=\"2250\"\u003eMemory storage for up to 200 data sets\u003cbr data-start=\"2288\" data-end=\"2291\"\u003eLow stray light optical system\u003cbr data-start=\"2321\" data-end=\"2324\"\u003eSuitable for laboratory and industrial water testing\u003c\/p\u003e\n\u003ch3 data-start=\"2378\" data-end=\"2405\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"2407\" data-end=\"3198\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"2407\" data-end=\"2436\"\u003e\n\u003ctr data-start=\"2407\" data-end=\"2436\"\u003e\n\u003cth data-start=\"2407\" data-end=\"2419\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth data-start=\"2419\" data-end=\"2436\" data-col-size=\"md\" class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"2451\" data-end=\"3198\"\u003e\n\u003ctr data-start=\"2451\" data-end=\"2485\"\u003e\n\u003ctd data-start=\"2451\" data-end=\"2471\" data-col-size=\"sm\"\u003eMeasurement Range\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2471\" data-end=\"2485\"\u003e1–2000 NTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2486\" data-end=\"2556\"\u003e\n\u003ctd data-start=\"2486\" data-end=\"2499\" data-col-size=\"sm\"\u003eResolution\u003c\/td\u003e\n\u003ctd data-start=\"2499\" data-end=\"2556\" data-col-size=\"md\"\u003e0.01 (1–100 NTU), 0.1 (100–999 NTU), 1 (999–2000 NTU)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2557\" data-end=\"2575\"\u003e\n\u003ctd data-start=\"2557\" data-end=\"2568\" data-col-size=\"sm\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2568\" data-end=\"2575\"\u003e±5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2576\" data-end=\"2614\"\u003e\n\u003ctd data-start=\"2576\" data-end=\"2597\" data-col-size=\"sm\"\u003eCalibration Points\u003c\/td\u003e\n\u003ctd data-start=\"2597\" data-end=\"2614\" data-col-size=\"md\"\u003e2 to 7 Points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2615\" data-end=\"2683\"\u003e\n\u003ctd data-start=\"2615\" data-end=\"2639\" data-col-size=\"sm\"\u003eCalibration Standards\u003c\/td\u003e\n\u003ctd data-start=\"2639\" data-end=\"2683\" data-col-size=\"md\"\u003e0.02, 10, 200, 500, 1000, 1500, 2000 NTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2684\" data-end=\"2734\"\u003e\n\u003ctd data-start=\"2684\" data-end=\"2696\" data-col-size=\"sm\"\u003eTSS Range\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2696\" data-end=\"2734\"\u003eDepending on TSS Conversion Factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2735\" data-end=\"2763\"\u003e\n\u003ctd data-start=\"2735\" data-end=\"2752\" data-col-size=\"sm\"\u003eTSS Resolution\u003c\/td\u003e\n\u003ctd data-start=\"2752\" data-end=\"2763\" data-col-size=\"md\"\u003e0.0 \/ 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2764\" data-end=\"2797\"\u003e\n\u003ctd data-start=\"2764\" data-end=\"2779\" data-col-size=\"sm\"\u003eTSS Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"2779\" data-end=\"2797\" data-col-size=\"md\"\u003e±3% of Reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2798\" data-end=\"2849\"\u003e\n\u003ctd data-start=\"2798\" data-end=\"2813\" data-col-size=\"sm\"\u003eLight Source\u003c\/td\u003e\n\u003ctd data-start=\"2813\" data-end=\"2849\" data-col-size=\"md\"\u003eInfrared Emitting Diode (850 nm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2850\" data-end=\"2883\"\u003e\n\u003ctd data-start=\"2850\" data-end=\"2861\" data-col-size=\"sm\"\u003eDetector\u003c\/td\u003e\n\u003ctd data-start=\"2861\" data-end=\"2883\" data-col-size=\"md\"\u003eSilicon Photodiode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2884\" data-end=\"2911\"\u003e\n\u003ctd data-start=\"2884\" data-end=\"2898\" data-col-size=\"sm\"\u003eStray Light\u003c\/td\u003e\n\u003ctd data-start=\"2898\" data-end=\"2911\" data-col-size=\"md\"\u003e\u0026lt;0.02 NTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2912\" data-end=\"2954\"\u003e\n\u003ctd data-start=\"2912\" data-end=\"2927\" data-col-size=\"sm\"\u003eSample Vials\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2927\" data-end=\"2954\"\u003e60 (H) × 25 mm Diameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2955\" data-end=\"2987\"\u003e\n\u003ctd data-start=\"2955\" data-end=\"2964\" data-col-size=\"sm\"\u003eMemory\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2964\" data-end=\"2987\"\u003eUp to 200 Data Sets\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2988\" data-end=\"3022\"\u003e\n\u003ctd data-start=\"2988\" data-end=\"2998\" data-col-size=\"sm\"\u003eDisplay\u003c\/td\u003e\n\u003ctd data-start=\"2998\" data-end=\"3022\" data-col-size=\"md\"\u003e4.5-inch TFT Display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3023\" data-end=\"3052\"\u003e\n\u003ctd data-start=\"3023\" data-end=\"3045\" data-col-size=\"sm\"\u003ePassword Protection\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3045\" data-end=\"3052\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3053\" data-end=\"3087\"\u003e\n\u003ctd data-start=\"3053\" data-end=\"3077\" data-col-size=\"sm\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3077\" data-end=\"3087\"\u003e0–50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3088\" data-end=\"3136\"\u003e\n\u003ctd data-start=\"3088\" data-end=\"3103\" data-col-size=\"sm\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd data-start=\"3103\" data-end=\"3136\" data-col-size=\"md\"\u003eDC Adaptor, AC 220V \/ 50–60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3137\" data-end=\"3180\"\u003e\n\u003ctd data-start=\"3137\" data-end=\"3158\" data-col-size=\"sm\"\u003eDimensions (L×W×H)\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3158\" data-end=\"3180\"\u003e310 × 255 × 190 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3181\" data-end=\"3198\"\u003e\n\u003ctd data-start=\"3181\" data-end=\"3190\" data-col-size=\"sm\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-start=\"3190\" data-end=\"3198\" data-col-size=\"md\"\u003e2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 data-start=\"3200\" data-end=\"3215\"\u003eApplications\u003c\/h3\u003e\n\u003cp data-start=\"3217\" data-end=\"3448\"\u003eIndustrial wastewater analysis\u003cbr data-start=\"3247\" data-end=\"3250\"\u003eMunicipal water treatment testing\u003cbr data-start=\"3283\" data-end=\"3286\"\u003eEnvironmental monitoring laboratories\u003cbr data-start=\"3323\" data-end=\"3326\"\u003eWater quality analysis\u003cbr data-start=\"3348\" data-end=\"3351\"\u003eFood and beverage processing\u003cbr data-start=\"3379\" data-end=\"3382\"\u003eAcademic and research laboratories\u003cbr data-start=\"3416\" data-end=\"3419\"\u003eIndustrial process monitoring\u003c\/p\u003e","brand":"Labman","offers":[{"title":"Default Title","offer_id":49973052440813,"sku":null,"price":60000.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5672\/6765\/files\/LMTB200.jpg?v=1778962945"},{"product_id":"portable-turbidity-meter-lmtb5p-nephelometric-90-method-usb-interface","title":"Portable Turbidity Meter LMTB5P (Nephelometric 90° Method, USB Interface)","description":"\u003cp\u003e\u003cimg\u003ePortable Turbidity Meter LMTB5P is designed for accurate turbidity analysis in laboratory, environmental, and field testing applications. Based on the nephelometric 90° measurement principle, the instrument delivers reliable and repeatable turbidity measurements for water quality monitoring and industrial testing.\u003c\/p\u003e\n\u003cp data-start=\"618\" data-end=\"931\"\u003eThe meter supports turbidity measurement ranges up to 1100 NTU with selectable units including NTU, FNU, EBC, and ASBC, making it suitable for multiple industrial and laboratory standards. Multi-point calibration capability using Formazin standards improves measurement accuracy across different turbidity ranges.\u003c\/p\u003e\n\u003cp data-start=\"933\" data-end=\"1202\"\u003eLMTB5P features both single and continuous measurement modes, allowing users to perform rapid sample analysis and vial indexing for improved repeatability. The instrument automatically detects stable readings and locks the measurement endpoint for simplified operation.\u003c\/p\u003e\n\u003cp data-start=\"1204\" data-end=\"1466\"\u003eAn infrared 850 nm light source combined with a silicon photoelectric detector ensures stable optical performance with low stray light interference. The compact handheld design with battery operation makes the instrument suitable for portable field applications.\u003c\/p\u003e\n\u003cp data-start=\"1468\" data-end=\"1752\"\u003eThe system includes internal memory for storing up to 100 data sets, USB communication interface for data transfer, automatic power-off functionality for battery conservation, and customizable operational settings including calibration points, resolution, and date\/time configuration.\u003c\/p\u003e\n\u003cp data-start=\"1754\" data-end=\"1954\"\u003eLMTB5P is suitable for water treatment plants, environmental monitoring, industrial wastewater testing, food and beverage processing, educational laboratories, and on-site field analysis applications.\u003c\/p\u003e\n\u003ch3 data-start=\"1956\" data-end=\"1971\"\u003eKey Features\u003c\/h3\u003e\n\u003cp data-start=\"1973\" data-end=\"2519\"\u003ePortable turbidity meter with nephelometric 90° method\u003cbr data-start=\"2027\" data-end=\"2030\"\u003eMeasurement range up to 1100 NTU\u003cbr data-start=\"2062\" data-end=\"2065\"\u003eSelectable turbidity units including NTU, FNU, EBC, and ASBC\u003cbr data-start=\"2125\" data-end=\"2128\"\u003e2 to 5-point calibration using Formazin standards\u003cbr data-start=\"2177\" data-end=\"2180\"\u003eInfrared 850 nm optical system\u003cbr data-start=\"2210\" data-end=\"2213\"\u003eSingle and continuous measurement modes\u003cbr data-start=\"2252\" data-end=\"2255\"\u003eAutomatic endpoint detection and reading lock\u003cbr data-start=\"2300\" data-end=\"2303\"\u003eUSB communication interface for data transfer\u003cbr data-start=\"2348\" data-end=\"2351\"\u003eInternal memory for up to 100 readings\u003cbr data-start=\"2389\" data-end=\"2392\"\u003eAuto power-off and automatic shutdown functions\u003cbr data-start=\"2439\" data-end=\"2442\"\u003eBattery and DC adaptor operation\u003cbr data-start=\"2474\" data-end=\"2477\"\u003eCompact handheld design with carrying case\u003c\/p\u003e\n\u003ch3 data-start=\"2521\" data-end=\"2548\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"2550\" data-end=\"3486\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"2550\" data-end=\"2579\"\u003e\n\u003ctr data-start=\"2550\" data-end=\"2579\"\u003e\n\u003cth data-start=\"2550\" data-end=\"2562\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth data-start=\"2562\" data-end=\"2579\" data-col-size=\"md\" class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"2594\" data-end=\"3486\"\u003e\n\u003ctr data-start=\"2594\" data-end=\"2636\"\u003e\n\u003ctd data-start=\"2594\" data-end=\"2606\" data-col-size=\"sm\"\u003ePrinciple\u003c\/td\u003e\n\u003ctd data-start=\"2606\" data-end=\"2636\" data-col-size=\"md\"\u003eNephelometric Method (90°)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2637\" data-end=\"2705\"\u003e\n\u003ctd data-start=\"2637\" data-end=\"2665\" data-col-size=\"sm\"\u003eTurbidity Measuring Range\u003c\/td\u003e\n\u003ctd data-start=\"2665\" data-end=\"2705\" data-col-size=\"md\"\u003e1–1100 NTU \/ 0–275 EBC \/ 0–9999 ASBC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2706\" data-end=\"2784\"\u003e\n\u003ctd data-start=\"2706\" data-end=\"2727\" data-col-size=\"sm\"\u003eDisplay Resolution\u003c\/td\u003e\n\u003ctd data-start=\"2727\" data-end=\"2784\" data-col-size=\"md\"\u003e0.01 (1–99 NTU), 0.1 (100–999 NTU), 1 (1000–1100 NTU)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2785\" data-end=\"2815\"\u003e\n\u003ctd data-start=\"2785\" data-end=\"2808\" data-col-size=\"sm\"\u003eMeasurement Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"2808\" data-end=\"2815\" data-col-size=\"md\"\u003e±3%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2816\" data-end=\"2891\"\u003e\n\u003ctd data-start=\"2816\" data-end=\"2843\" data-col-size=\"sm\"\u003eCalibration Point Option\u003c\/td\u003e\n\u003ctd data-start=\"2843\" data-end=\"2891\" data-col-size=\"md\"\u003e2 to 5 Points (0.02, 10, 200, 500, 1000 NTU)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2892\" data-end=\"2938\"\u003e\n\u003ctd data-start=\"2892\" data-end=\"2916\" data-col-size=\"sm\"\u003eCalibration Standards\u003c\/td\u003e\n\u003ctd data-start=\"2916\" data-end=\"2938\" data-col-size=\"md\"\u003e200, 500, 1000 NTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2939\" data-end=\"2980\"\u003e\n\u003ctd data-start=\"2939\" data-end=\"2957\" data-col-size=\"sm\"\u003eTurbidity Units\u003c\/td\u003e\n\u003ctd data-start=\"2957\" data-end=\"2980\" data-col-size=\"md\"\u003eNTU, FNU, EBC, ASBC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2981\" data-end=\"3037\"\u003e\n\u003ctd data-start=\"2981\" data-end=\"2996\" data-col-size=\"sm\"\u003eLight Source\u003c\/td\u003e\n\u003ctd data-start=\"2996\" data-end=\"3037\" data-col-size=\"md\"\u003eInfrared Light Emitting Diode, 850 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3038\" data-end=\"3083\"\u003e\n\u003ctd data-start=\"3038\" data-end=\"3049\" data-col-size=\"sm\"\u003eDetector\u003c\/td\u003e\n\u003ctd data-start=\"3049\" data-end=\"3083\" data-col-size=\"md\"\u003eSilicon Photoelectric Detector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3084\" data-end=\"3111\"\u003e\n\u003ctd data-start=\"3084\" data-end=\"3098\" data-col-size=\"sm\"\u003eStray Light\u003c\/td\u003e\n\u003ctd data-start=\"3098\" data-end=\"3111\" data-col-size=\"md\"\u003e\u0026lt;0.02 NTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3112\" data-end=\"3157\"\u003e\n\u003ctd data-start=\"3112\" data-end=\"3124\" data-col-size=\"sm\"\u003eVial Size\u003c\/td\u003e\n\u003ctd data-start=\"3124\" data-end=\"3157\" data-col-size=\"md\"\u003e60 mm Height × 25 mm Diameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3158\" data-end=\"3191\"\u003e\n\u003ctd data-start=\"3158\" data-end=\"3174\" data-col-size=\"sm\"\u003eSample Volume\u003c\/td\u003e\n\u003ctd data-start=\"3174\" data-end=\"3191\" data-col-size=\"md\"\u003eApprox. 30 ml\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3192\" data-end=\"3221\"\u003e\n\u003ctd data-start=\"3192\" data-end=\"3208\" data-col-size=\"sm\"\u003eCarrying Case\u003c\/td\u003e\n\u003ctd data-start=\"3208\" data-end=\"3221\" data-col-size=\"md\"\u003eAvailable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3222\" data-end=\"3246\"\u003e\n\u003ctd data-start=\"3222\" data-end=\"3239\" data-col-size=\"sm\"\u003eAuto Power Off\u003c\/td\u003e\n\u003ctd data-start=\"3239\" data-end=\"3246\" data-col-size=\"md\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3247\" data-end=\"3264\"\u003e\n\u003ctd data-start=\"3247\" data-end=\"3257\" data-col-size=\"sm\"\u003eDisplay\u003c\/td\u003e\n\u003ctd data-start=\"3257\" data-end=\"3264\" data-col-size=\"md\"\u003eLCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3265\" data-end=\"3307\"\u003e\n\u003ctd data-start=\"3265\" data-end=\"3280\" data-col-size=\"sm\"\u003eData Storage\u003c\/td\u003e\n\u003ctd data-start=\"3280\" data-end=\"3307\" data-col-size=\"md\"\u003eUp to 100 Data Readings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3308\" data-end=\"3346\"\u003e\n\u003ctd data-start=\"3308\" data-end=\"3330\" data-col-size=\"sm\"\u003eAmbient Temperature\u003c\/td\u003e\n\u003ctd data-start=\"3330\" data-end=\"3346\" data-col-size=\"md\"\u003e10°C to 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3347\" data-end=\"3366\"\u003e\n\u003ctd data-start=\"3347\" data-end=\"3359\" data-col-size=\"sm\"\u003eInterface\u003c\/td\u003e\n\u003ctd data-start=\"3359\" data-end=\"3366\" data-col-size=\"md\"\u003eUSB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3367\" data-end=\"3425\"\u003e\n\u003ctd data-start=\"3367\" data-end=\"3382\" data-col-size=\"sm\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd data-start=\"3382\" data-end=\"3425\" data-col-size=\"md\"\u003e3 × AA Batteries or DC 5V Power Adaptor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3426\" data-end=\"3468\"\u003e\n\u003ctd data-start=\"3426\" data-end=\"3447\" data-col-size=\"sm\"\u003eDimensions (L×W×H)\u003c\/td\u003e\n\u003ctd data-start=\"3447\" data-end=\"3468\" data-col-size=\"md\"\u003e290 × 90 × 240 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3469\" data-end=\"3486\"\u003e\n\u003ctd data-start=\"3469\" data-end=\"3478\" data-col-size=\"sm\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-start=\"3478\" data-end=\"3486\" data-col-size=\"md\"\u003e1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 data-start=\"3488\" data-end=\"3503\"\u003eApplications\u003c\/h3\u003e\n\u003cp data-start=\"3505\" data-end=\"3771\"\u003ePortable water quality testing\u003cbr data-start=\"3535\" data-end=\"3538\"\u003eEnvironmental monitoring and field analysis\u003cbr data-start=\"3581\" data-end=\"3584\"\u003eMunicipal water treatment testing\u003cbr data-start=\"3617\" data-end=\"3620\"\u003eIndustrial wastewater analysis\u003cbr data-start=\"3650\" data-end=\"3653\"\u003eFood and beverage quality control\u003cbr data-start=\"3686\" data-end=\"3689\"\u003eEducational and research laboratories\u003cbr data-start=\"3726\" data-end=\"3729\"\u003eOn-site turbidity measurement applications\u003c\/p\u003e","brand":"Labman","offers":[{"title":"Default Title","offer_id":49973054013677,"sku":null,"price":45000.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5672\/6765\/files\/LMTB5P.webp?v=1778963031"},{"product_id":"portable-ph-meter-lmph1p-auto-calibration-usb-interface","title":"Portable pH Meter LMPH1P (Auto Calibration, USB Interface)","description":"\u003cp data-start=\"272\" data-end=\"602\"\u003ePortable pH Meter LMPH1P is designed for accurate pH, mV, and temperature measurement in laboratory, industrial, educational, and field testing applications. The compact handheld instrument combines portability with stable analytical performance, making it suitable for routine water quality analysis and environmental monitoring.\u003c\/p\u003e\n\u003cp data-start=\"604\" data-end=\"891\"\u003eThe meter supports automatic calibration with USA and NIST buffer standards and allows 1 to 3-point calibration for improved measurement accuracy across different pH ranges. Automatic electrode diagnosis helps users monitor electrode condition and determine when replacement is required.\u003c\/p\u003e\n\u003cp data-start=\"893\" data-end=\"1171\"\u003eLMPH1P features automatic and manual temperature compensation to ensure accurate readings over varying sample temperatures. The instrument also includes auto-read endpoint detection, which senses stable measurement conditions and locks the final reading for consistent analysis.\u003c\/p\u003e\n\u003cp data-start=\"1173\" data-end=\"1413\"\u003eAn LCD display with white backlight provides clear visibility during operation, while internal memory stores up to 100 data sets for easy recall and documentation. USB connectivity allows data transfer and external power adaptor connection.\u003c\/p\u003e\n\u003cp data-start=\"1415\" data-end=\"1675\"\u003eThe portable design operates on AA batteries or DC power adaptor, making the instrument suitable for both laboratory bench use and on-site field applications. Automatic shutdown and auto power-off functions help conserve battery life during extended operation.\u003c\/p\u003e\n\u003cp data-start=\"1677\" data-end=\"1867\"\u003eLMPH1P is widely used in water treatment plants, environmental testing laboratories, educational institutions, food and beverage testing, aquaculture, and routine pH monitoring applications.\u003c\/p\u003e\n\u003ch3 data-start=\"1869\" data-end=\"1884\"\u003eKey Features\u003c\/h3\u003e\n\u003cp data-start=\"1886\" data-end=\"2390\"\u003ePortable pH, mV, and temperature measurement\u003cbr data-start=\"1930\" data-end=\"1933\"\u003e1 to 3-point automatic calibration\u003cbr data-start=\"1967\" data-end=\"1970\"\u003eSupports USA and NIST pH buffer standards\u003cbr data-start=\"2011\" data-end=\"2014\"\u003eAutomatic electrode diagnosis function\u003cbr data-start=\"2052\" data-end=\"2055\"\u003eAutomatic and manual temperature compensation\u003cbr data-start=\"2100\" data-end=\"2103\"\u003eAuto-read endpoint detection for stable measurements\u003cbr data-start=\"2155\" data-end=\"2158\"\u003eLCD display with white backlight\u003cbr data-start=\"2190\" data-end=\"2193\"\u003eUSB communication interface\u003cbr data-start=\"2220\" data-end=\"2223\"\u003eInternal memory for up to 100 data sets\u003cbr data-start=\"2262\" data-end=\"2265\"\u003eBattery and DC adaptor operation\u003cbr data-start=\"2297\" data-end=\"2300\"\u003eAutomatic shutdown and power-saving functions\u003cbr data-start=\"2345\" data-end=\"2348\"\u003eCompact portable design with carrying case\u003c\/p\u003e\n\u003ch3 data-start=\"2392\" data-end=\"2419\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"2421\" data-end=\"3363\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"2421\" data-end=\"2450\"\u003e\n\u003ctr data-start=\"2421\" data-end=\"2450\"\u003e\n\u003cth data-start=\"2421\" data-end=\"2433\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth data-start=\"2433\" data-end=\"2450\" data-col-size=\"md\" class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"2465\" data-end=\"3363\"\u003e\n\u003ctr data-start=\"2465\" data-end=\"2497\"\u003e\n\u003ctd data-start=\"2465\" data-end=\"2476\" data-col-size=\"sm\"\u003epH Range\u003c\/td\u003e\n\u003ctd data-start=\"2476\" data-end=\"2497\" data-col-size=\"md\"\u003e-2.00 to 20.00 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2498\" data-end=\"2525\"\u003e\n\u003ctd data-start=\"2498\" data-end=\"2514\" data-col-size=\"sm\"\u003epH Resolution\u003c\/td\u003e\n\u003ctd data-start=\"2514\" data-end=\"2525\" data-col-size=\"md\"\u003e0.01 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2526\" data-end=\"2552\"\u003e\n\u003ctd data-start=\"2526\" data-end=\"2540\" data-col-size=\"sm\"\u003epH Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"2540\" data-end=\"2552\" data-col-size=\"md\"\u003e±0.01 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2553\" data-end=\"2655\"\u003e\n\u003ctd data-start=\"2553\" data-end=\"2573\" data-col-size=\"sm\"\u003epH Buffer Options\u003c\/td\u003e\n\u003ctd data-start=\"2573\" data-end=\"2655\" data-col-size=\"md\"\u003e1 to 3 Points Calibration, USA (pH 4.01\/7.00\/10.01) \/ NIST (pH 4.01\/6.86\/9.18)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2656\" data-end=\"2679\"\u003e\n\u003ctd data-start=\"2656\" data-end=\"2667\" data-col-size=\"sm\"\u003emV Range\u003c\/td\u003e\n\u003ctd data-start=\"2667\" data-end=\"2679\" data-col-size=\"md\"\u003e±1999 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2680\" data-end=\"2704\"\u003e\n\u003ctd data-start=\"2680\" data-end=\"2696\" data-col-size=\"sm\"\u003emV Resolution\u003c\/td\u003e\n\u003ctd data-start=\"2696\" data-end=\"2704\" data-col-size=\"md\"\u003e1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2705\" data-end=\"2728\"\u003e\n\u003ctd data-start=\"2705\" data-end=\"2719\" data-col-size=\"sm\"\u003emV Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"2719\" data-end=\"2728\" data-col-size=\"md\"\u003e±1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2729\" data-end=\"2777\"\u003e\n\u003ctd data-start=\"2729\" data-end=\"2749\" data-col-size=\"sm\"\u003eTemperature Range\u003c\/td\u003e\n\u003ctd data-start=\"2749\" data-end=\"2777\" data-col-size=\"md\"\u003e0 to 105°C \/ 32 to 221°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2778\" data-end=\"2820\"\u003e\n\u003ctd data-start=\"2778\" data-end=\"2803\" data-col-size=\"sm\"\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd data-start=\"2803\" data-end=\"2820\" data-col-size=\"md\"\u003e0.1°C \/ 0.1°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2821\" data-end=\"2863\"\u003e\n\u003ctd data-start=\"2821\" data-end=\"2844\" data-col-size=\"sm\"\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"2844\" data-end=\"2863\" data-col-size=\"md\"\u003e±0.5°C \/ ±0.9°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2864\" data-end=\"2940\"\u003e\n\u003ctd data-start=\"2864\" data-end=\"2891\" data-col-size=\"sm\"\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd data-start=\"2891\" data-end=\"2940\" data-col-size=\"md\"\u003e0 to 100°C \/ 32 to 212°F, Manual or Automatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2941\" data-end=\"3000\"\u003e\n\u003ctd data-start=\"2941\" data-end=\"2957\" data-col-size=\"sm\"\u003eHold Function\u003c\/td\u003e\n\u003ctd data-start=\"2957\" data-end=\"3000\" data-col-size=\"md\"\u003eManual \/ Auto-read Measurement Endpoint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3001\" data-end=\"3039\"\u003e\n\u003ctd data-start=\"3001\" data-end=\"3011\" data-col-size=\"sm\"\u003eDisplay\u003c\/td\u003e\n\u003ctd data-start=\"3011\" data-end=\"3039\" data-col-size=\"md\"\u003eLCD with White Backlight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3040\" data-end=\"3059\"\u003e\n\u003ctd data-start=\"3040\" data-end=\"3052\" data-col-size=\"sm\"\u003eInterface\u003c\/td\u003e\n\u003ctd data-start=\"3052\" data-end=\"3059\" data-col-size=\"md\"\u003eUSB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3060\" data-end=\"3079\"\u003e\n\u003ctd data-start=\"3060\" data-end=\"3072\" data-col-size=\"sm\"\u003eConnector\u003c\/td\u003e\n\u003ctd data-start=\"3072\" data-end=\"3079\" data-col-size=\"md\"\u003eBNC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3080\" data-end=\"3109\"\u003e\n\u003ctd data-start=\"3080\" data-end=\"3096\" data-col-size=\"sm\"\u003eCarrying Case\u003c\/td\u003e\n\u003ctd data-start=\"3096\" data-end=\"3109\" data-col-size=\"md\"\u003eAvailable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3110\" data-end=\"3150\"\u003e\n\u003ctd data-start=\"3110\" data-end=\"3121\" data-col-size=\"sm\"\u003eAuto OFF\u003c\/td\u003e\n\u003ctd data-start=\"3121\" data-end=\"3150\" data-col-size=\"md\"\u003e30 Minutes, If Not in Use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3151\" data-end=\"3177\"\u003e\n\u003ctd data-start=\"3151\" data-end=\"3160\" data-col-size=\"sm\"\u003eMemory\u003c\/td\u003e\n\u003ctd data-start=\"3160\" data-end=\"3177\" data-col-size=\"md\"\u003e100 Data Sets\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3178\" data-end=\"3241\"\u003e\n\u003ctd data-start=\"3178\" data-end=\"3193\" data-col-size=\"sm\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd data-start=\"3193\" data-end=\"3241\" data-col-size=\"md\"\u003e3 × 1.5V AA Batteries or 5V DC Power Adaptor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3242\" data-end=\"3302\"\u003e\n\u003ctd data-start=\"3242\" data-end=\"3257\" data-col-size=\"sm\"\u003eBattery Life\u003c\/td\u003e\n\u003ctd data-start=\"3257\" data-end=\"3302\" data-col-size=\"md\"\u003eApproximately 150 Hours Without Backlight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3303\" data-end=\"3345\"\u003e\n\u003ctd data-start=\"3303\" data-end=\"3324\" data-col-size=\"sm\"\u003eDimensions (L×W×H)\u003c\/td\u003e\n\u003ctd data-start=\"3324\" data-end=\"3345\" data-col-size=\"md\"\u003e340 × 90 × 300 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3346\" data-end=\"3363\"\u003e\n\u003ctd data-start=\"3346\" data-end=\"3355\" data-col-size=\"sm\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-start=\"3355\" data-end=\"3363\" data-col-size=\"md\"\u003e2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 data-start=\"3365\" data-end=\"3380\"\u003eApplications\u003c\/h3\u003e\n\u003cp data-start=\"3382\" data-end=\"3617\"\u003ePortable water quality testing\u003cbr data-start=\"3412\" data-end=\"3415\"\u003eEnvironmental monitoring and field analysis\u003cbr data-start=\"3458\" data-end=\"3461\"\u003eLaboratory pH measurement\u003cbr data-start=\"3486\" data-end=\"3489\"\u003eFood and beverage testing\u003cbr data-start=\"3514\" data-end=\"3517\"\u003eAquaculture and water treatment\u003cbr data-start=\"3548\" data-end=\"3551\"\u003eEducational and research laboratories\u003cbr data-start=\"3588\" data-end=\"3591\"\u003eIndustrial liquid analysis\u003c\/p\u003e","brand":"Labman","offers":[{"title":"Default Title","offer_id":49973059813613,"sku":null,"price":15000.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5672\/6765\/files\/LMPH1P.webp?v=1778963174"},{"product_id":"portable-conductivity-meter-lmcm2p-auto-range-usb-interface","title":"Portable Conductivity Meter LMCM2P (Auto Range, USB Interface)","description":"\u003cp data-start=\"275\" data-end=\"580\"\u003ePortable Conductivity Meter LMCM2P is designed for accurate conductivity, TDS, and temperature measurement in laboratory, industrial, environmental, and field testing applications. The handheld instrument combines portable operation with reliable analytical performance for routine water quality analysis.\u003c\/p\u003e\n\u003cp data-start=\"582\" data-end=\"890\"\u003eThe meter features automatic ranging conductivity measurement with selectable cell constants (K=0.1\/1\/10), allowing accurate testing across low and high conductivity samples. It supports 1 to 3-point calibration with automatic conductivity standard recognition for simplified operation and improved accuracy.\u003c\/p\u003e\n\u003cp data-start=\"892\" data-end=\"1161\"\u003eLMCM2P provides simultaneous conductivity and TDS analysis with automatic or manual temperature compensation to ensure stable and precise readings under varying sample conditions. Auto-read endpoint detection locks stable measurements for consistent analytical results.\u003c\/p\u003e\n\u003cp data-start=\"1163\" data-end=\"1470\"\u003eThe instrument includes a backlit LCD display for easy viewing, internal memory for storing up to 100 data sets, and USB communication interface for data transfer and external power connectivity. Battery-powered operation and automatic shutdown functions make the meter suitable for portable field analysis.\u003c\/p\u003e\n\u003cp data-start=\"1472\" data-end=\"1749\"\u003eWith compact construction, high measurement flexibility, and multi-parameter capability, LMCM2P is ideal for water treatment plants, environmental monitoring, industrial process control, aquaculture, food processing, educational laboratories, and routine water quality testing.\u003c\/p\u003e\n\u003ch3 data-start=\"1751\" data-end=\"1766\"\u003eKey Features\u003c\/h3\u003e\n\u003cp data-start=\"1768\" data-end=\"2248\"\u003ePortable conductivity, TDS, and temperature measurement\u003cbr data-start=\"1823\" data-end=\"1826\"\u003eAuto-ranging conductivity measurement system\u003cbr data-start=\"1870\" data-end=\"1873\"\u003eSelectable cell constants K=0.1\/1\/10\u003cbr data-start=\"1909\" data-end=\"1912\"\u003e1 to 3-point conductivity calibration\u003cbr data-start=\"1949\" data-end=\"1952\"\u003eAutomatic conductivity standard recognition\u003cbr data-start=\"1995\" data-end=\"1998\"\u003eAutomatic and manual temperature compensation\u003cbr data-start=\"2043\" data-end=\"2046\"\u003eAuto-read endpoint detection\u003cbr data-start=\"2074\" data-end=\"2077\"\u003eBacklit LCD display\u003cbr data-start=\"2096\" data-end=\"2099\"\u003eUSB communication interface\u003cbr data-start=\"2126\" data-end=\"2129\"\u003eInternal memory for up to 100 data sets\u003cbr data-start=\"2168\" data-end=\"2171\"\u003eBattery and DC adaptor operation\u003cbr data-start=\"2203\" data-end=\"2206\"\u003eCompact handheld design with carrying case\u003c\/p\u003e\n\u003ch3 data-start=\"2250\" data-end=\"2277\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"2279\" data-end=\"3344\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"2279\" data-end=\"2308\"\u003e\n\u003ctr data-start=\"2279\" data-end=\"2308\"\u003e\n\u003cth data-start=\"2279\" data-end=\"2291\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth data-start=\"2291\" data-end=\"2308\" data-col-size=\"md\" class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"2323\" data-end=\"3344\"\u003e\n\u003ctr data-start=\"2323\" data-end=\"2410\"\u003e\n\u003ctd data-start=\"2323\" data-end=\"2344\" data-col-size=\"sm\"\u003eConductivity Range\u003c\/td\u003e\n\u003ctd data-start=\"2344\" data-end=\"2410\" data-col-size=\"md\"\u003e0 to 20.00, 200.0, 2000 µS\/cm, 20.00, 200.0 mS\/cm (Auto Range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2411\" data-end=\"2453\"\u003e\n\u003ctd data-start=\"2411\" data-end=\"2437\" data-col-size=\"sm\"\u003eConductivity Resolution\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2437\" data-end=\"2453\"\u003e0.01, 0.1, 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2454\" data-end=\"2492\"\u003e\n\u003ctd data-start=\"2454\" data-end=\"2478\" data-col-size=\"sm\"\u003eConductivity Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"2478\" data-end=\"2492\" data-col-size=\"md\"\u003e±0.5% F.S.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2493\" data-end=\"2537\"\u003e\n\u003ctd data-start=\"2493\" data-end=\"2520\" data-col-size=\"sm\"\u003eConductivity Calibration\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2520\" data-end=\"2537\"\u003e1 to 3 Points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2538\" data-end=\"2617\"\u003e\n\u003ctd data-start=\"2538\" data-end=\"2568\" data-col-size=\"sm\"\u003eConductivity Buffer Options\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2568\" data-end=\"2617\"\u003e10 µS \/ 84 µS \/ 1413 µS \/ 12.88 mS \/ 111.8 mS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2618\" data-end=\"2679\"\u003e\n\u003ctd data-start=\"2618\" data-end=\"2630\" data-col-size=\"sm\"\u003eTDS Range\u003c\/td\u003e\n\u003ctd data-start=\"2630\" data-end=\"2679\" data-col-size=\"md\"\u003e0 to 10.00, 100.0, 1000 ppm, 10.00, 200.0 ppt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2680\" data-end=\"2713\"\u003e\n\u003ctd data-start=\"2680\" data-end=\"2697\" data-col-size=\"sm\"\u003eTDS Resolution\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2697\" data-end=\"2713\"\u003e0.01, 0.1, 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2714\" data-end=\"2741\"\u003e\n\u003ctd data-start=\"2714\" data-end=\"2729\" data-col-size=\"sm\"\u003eTDS Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"2729\" data-end=\"2741\" data-col-size=\"md\"\u003e±1% F.S.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2742\" data-end=\"2790\"\u003e\n\u003ctd data-start=\"2742\" data-end=\"2762\" data-col-size=\"sm\"\u003eTemperature Range\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2762\" data-end=\"2790\"\u003e0 to 105°C \/ 32 to 221°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2791\" data-end=\"2825\"\u003e\n\u003ctd data-start=\"2791\" data-end=\"2816\" data-col-size=\"sm\"\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2816\" data-end=\"2825\"\u003e0.1°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2826\" data-end=\"2868\"\u003e\n\u003ctd data-start=\"2826\" data-end=\"2849\" data-col-size=\"sm\"\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2849\" data-end=\"2868\"\u003e±0.5°C \/ ±0.9°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2869\" data-end=\"2945\"\u003e\n\u003ctd data-start=\"2869\" data-end=\"2896\" data-col-size=\"sm\"\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2896\" data-end=\"2945\"\u003e0 to 100°C \/ 32 to 212°F, Manual or Automatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2946\" data-end=\"2998\"\u003e\n\u003ctd data-start=\"2946\" data-end=\"2966\" data-col-size=\"sm\"\u003eConductivity Cell\u003c\/td\u003e\n\u003ctd data-start=\"2966\" data-end=\"2998\" data-col-size=\"md\"\u003eCell Constant K=0.1 \/ 1 \/ 10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2999\" data-end=\"3037\"\u003e\n\u003ctd data-start=\"2999\" data-end=\"3009\" data-col-size=\"sm\"\u003eDisplay\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3009\" data-end=\"3037\"\u003eLCD with White Backlight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3038\" data-end=\"3061\"\u003e\n\u003ctd data-start=\"3038\" data-end=\"3054\" data-col-size=\"sm\"\u003eHold Function\u003c\/td\u003e\n\u003ctd data-start=\"3054\" data-end=\"3061\" data-col-size=\"md\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3062\" data-end=\"3108\"\u003e\n\u003ctd data-start=\"3062\" data-end=\"3079\" data-col-size=\"sm\"\u003eAuto Power OFF\u003c\/td\u003e\n\u003ctd data-start=\"3079\" data-end=\"3108\" data-col-size=\"md\"\u003e15 Minutes, If Not in Use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3109\" data-end=\"3148\"\u003e\n\u003ctd data-start=\"3109\" data-end=\"3118\" data-col-size=\"sm\"\u003eMemory\u003c\/td\u003e\n\u003ctd data-start=\"3118\" data-end=\"3148\" data-col-size=\"md\"\u003eStores up to 100 Data Sets\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3149\" data-end=\"3168\"\u003e\n\u003ctd data-start=\"3149\" data-end=\"3161\" data-col-size=\"sm\"\u003eInterface\u003c\/td\u003e\n\u003ctd data-start=\"3161\" data-end=\"3168\" data-col-size=\"md\"\u003eUSB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3169\" data-end=\"3219\"\u003e\n\u003ctd data-start=\"3169\" data-end=\"3181\" data-col-size=\"sm\"\u003eConnector\u003c\/td\u003e\n\u003ctd data-start=\"3181\" data-end=\"3219\" data-col-size=\"md\"\u003e6-pin Mini-DIN, 3.5 mm Jack Socket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3220\" data-end=\"3283\"\u003e\n\u003ctd data-start=\"3220\" data-end=\"3235\" data-col-size=\"sm\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3235\" data-end=\"3283\"\u003e3 × 1.5V AA Batteries or 5V DC Power Adaptor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3284\" data-end=\"3326\"\u003e\n\u003ctd data-start=\"3284\" data-end=\"3305\" data-col-size=\"sm\"\u003eDimensions (L×W×H)\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3305\" data-end=\"3326\"\u003e350 × 90 × 300 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3327\" data-end=\"3344\"\u003e\n\u003ctd data-start=\"3327\" data-end=\"3336\" data-col-size=\"sm\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3336\" data-end=\"3344\"\u003e1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 data-start=\"3346\" data-end=\"3361\"\u003eApplications\u003c\/h3\u003e\n\u003cp data-start=\"3363\" data-end=\"3623\"\u003ePortable water quality testing\u003cbr data-start=\"3393\" data-end=\"3396\"\u003eEnvironmental monitoring and field analysis\u003cbr data-start=\"3439\" data-end=\"3442\"\u003eIndustrial process water testing\u003cbr data-start=\"3474\" data-end=\"3477\"\u003eAquaculture and hydroponics\u003cbr data-start=\"3504\" data-end=\"3507\"\u003eFood and beverage quality control\u003cbr data-start=\"3540\" data-end=\"3543\"\u003eEducational and research laboratories\u003cbr data-start=\"3580\" data-end=\"3583\"\u003eRoutine conductivity and TDS measurement\u003c\/p\u003e","brand":"Labman","offers":[{"title":"Default Title","offer_id":49973060436205,"sku":null,"price":20000.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5672\/6765\/files\/LMCM2P.webp?v=1778963394"},{"product_id":"portable-dissolved-oxygen-meter-lmdo4p-polarographic-sensor-usb-interface","title":"Portable Dissolved Oxygen Meter LMDO4P (Polarographic Sensor, USB Interface)","description":"\u003cp data-start=\"289\" data-end=\"613\"\u003ePortable Dissolved Oxygen Meter LMDO4P is designed for accurate dissolved oxygen and oxygen saturation measurement in environmental, industrial, laboratory, and field water testing applications. The compact handheld instrument provides reliable performance for routine dissolved oxygen monitoring and water quality analysis.\u003c\/p\u003e\n\u003cp data-start=\"615\" data-end=\"940\"\u003eThe meter uses a polarographic dissolved oxygen electrode for stable and precise DO measurement across a wide range of liquid samples. It supports dissolved oxygen measurement in mg\/L or ppm along with oxygen saturation percentage analysis, making it suitable for environmental monitoring and industrial process applications.\u003c\/p\u003e\n\u003cp data-start=\"942\" data-end=\"1276\"\u003eLMDO4P features 1 or 2-point calibration using air-saturated water or zero oxygen solution to ensure accurate measurement performance. Automatic temperature compensation improves reading accuracy over varying sample temperatures, while manual salinity and barometric pressure correction enhance dissolved oxygen measurement precision.\u003c\/p\u003e\n\u003cp data-start=\"1278\" data-end=\"1574\"\u003eThe instrument includes auto-read endpoint detection that locks stable readings automatically or manually for consistent analytical results. A backlit LCD display provides clear visibility during operation, while internal memory stores up to 100 data readings for future recall and documentation.\u003c\/p\u003e\n\u003cp data-start=\"1576\" data-end=\"1841\"\u003eUSB communication interface enables data transfer and external power adaptor connection. Battery-powered portable operation with automatic shutdown and power-saving functions makes the instrument ideal for on-site field analysis and mobile water quality monitoring.\u003c\/p\u003e\n\u003cp data-start=\"1843\" data-end=\"2029\"\u003eLMDO4P is widely used in environmental testing, aquaculture, wastewater treatment plants, educational laboratories, food processing, fisheries, and industrial water quality applications.\u003c\/p\u003e\n\u003ch3 data-start=\"2031\" data-end=\"2046\"\u003eKey Features\u003c\/h3\u003e\n\u003cp data-start=\"2048\" data-end=\"2515\"\u003ePortable dissolved oxygen and saturation measurement\u003cbr data-start=\"2100\" data-end=\"2103\"\u003ePolarographic dissolved oxygen electrode\u003cbr data-start=\"2143\" data-end=\"2146\"\u003eDO measurement in mg\/L or ppm\u003cbr data-start=\"2175\" data-end=\"2178\"\u003eOxygen saturation measurement up to 200%\u003cbr data-start=\"2218\" data-end=\"2221\"\u003e1 or 2-point calibration system\u003cbr data-start=\"2252\" data-end=\"2255\"\u003eAutomatic temperature compensation\u003cbr data-start=\"2289\" data-end=\"2292\"\u003eSalinity and barometric pressure correction\u003cbr data-start=\"2335\" data-end=\"2338\"\u003eAuto-read endpoint detection\u003cbr data-start=\"2366\" data-end=\"2369\"\u003eUSB communication interface\u003cbr data-start=\"2396\" data-end=\"2399\"\u003eBacklit LCD display\u003cbr data-start=\"2418\" data-end=\"2421\"\u003eInternal memory for up to 100 readings\u003cbr data-start=\"2459\" data-end=\"2462\"\u003eBattery-powered portable operation with carrying case\u003c\/p\u003e\n\u003ch3 data-start=\"2517\" data-end=\"2544\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"2546\" data-end=\"3501\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"2546\" data-end=\"2575\"\u003e\n\u003ctr data-start=\"2546\" data-end=\"2575\"\u003e\n\u003cth data-start=\"2546\" data-end=\"2558\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth data-start=\"2558\" data-end=\"2575\" data-col-size=\"md\" class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"2590\" data-end=\"3501\"\u003e\n\u003ctr data-start=\"2590\" data-end=\"2643\"\u003e\n\u003ctd data-start=\"2590\" data-end=\"2615\" data-col-size=\"sm\"\u003eDissolved Oxygen Range\u003c\/td\u003e\n\u003ctd data-start=\"2615\" data-end=\"2643\" data-col-size=\"md\"\u003e0.00 to 20.00 mg\/L (ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2644\" data-end=\"2693\"\u003e\n\u003ctd data-start=\"2644\" data-end=\"2674\" data-col-size=\"sm\"\u003eDissolved Oxygen Resolution\u003c\/td\u003e\n\u003ctd data-start=\"2674\" data-end=\"2693\" data-col-size=\"md\"\u003e0.01 mg\/L (ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2694\" data-end=\"2741\"\u003e\n\u003ctd data-start=\"2694\" data-end=\"2722\" data-col-size=\"sm\"\u003eDissolved Oxygen Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"2722\" data-end=\"2741\" data-col-size=\"md\"\u003e±0.5 mg\/L (ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2742\" data-end=\"2778\"\u003e\n\u003ctd data-start=\"2742\" data-end=\"2761\" data-col-size=\"sm\"\u003eSaturation Range\u003c\/td\u003e\n\u003ctd data-start=\"2761\" data-end=\"2778\" data-col-size=\"md\"\u003e0.0 to 200.0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2779\" data-end=\"2811\"\u003e\n\u003ctd data-start=\"2779\" data-end=\"2803\" data-col-size=\"sm\"\u003eSaturation Resolution\u003c\/td\u003e\n\u003ctd data-start=\"2803\" data-end=\"2811\" data-col-size=\"md\"\u003e0.1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2812\" data-end=\"2843\"\u003e\n\u003ctd data-start=\"2812\" data-end=\"2834\" data-col-size=\"sm\"\u003eSaturation Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"2834\" data-end=\"2843\" data-col-size=\"md\"\u003e±2.0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2844\" data-end=\"2875\"\u003e\n\u003ctd data-start=\"2844\" data-end=\"2858\" data-col-size=\"sm\"\u003eCalibration\u003c\/td\u003e\n\u003ctd data-start=\"2858\" data-end=\"2875\" data-col-size=\"md\"\u003e1 or 2 Points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2876\" data-end=\"2941\"\u003e\n\u003ctd data-start=\"2876\" data-end=\"2903\" data-col-size=\"sm\"\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd data-start=\"2903\" data-end=\"2941\" data-col-size=\"md\"\u003e0 to 50°C \/ 32 to 122°F, Automatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2942\" data-end=\"3011\"\u003e\n\u003ctd data-start=\"2942\" data-end=\"2964\" data-col-size=\"sm\"\u003ePressure Correction\u003c\/td\u003e\n\u003ctd data-start=\"2964\" data-end=\"3011\" data-col-size=\"md\"\u003e60.0 to 113.3 kPa \/ 450 to 850 mmHg, Manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3012\" data-end=\"3061\"\u003e\n\u003ctd data-start=\"3012\" data-end=\"3034\" data-col-size=\"sm\"\u003eSalinity Correction\u003c\/td\u003e\n\u003ctd data-start=\"3034\" data-end=\"3061\" data-col-size=\"md\"\u003e0.0 to 50.0 ppt, Manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3062\" data-end=\"3079\"\u003e\n\u003ctd data-start=\"3062\" data-end=\"3072\" data-col-size=\"sm\"\u003eDisplay\u003c\/td\u003e\n\u003ctd data-start=\"3072\" data-end=\"3079\" data-col-size=\"md\"\u003eLCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3080\" data-end=\"3150\"\u003e\n\u003ctd data-start=\"3080\" data-end=\"3096\" data-col-size=\"sm\"\u003eHold Function\u003c\/td\u003e\n\u003ctd data-start=\"3096\" data-end=\"3150\" data-col-size=\"md\"\u003eSelectable Manual or Automatic Hold after Endpoint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3151\" data-end=\"3197\"\u003e\n\u003ctd data-start=\"3151\" data-end=\"3168\" data-col-size=\"sm\"\u003eAuto Power OFF\u003c\/td\u003e\n\u003ctd data-start=\"3168\" data-end=\"3197\" data-col-size=\"md\"\u003e15 Minutes, If Not in Use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3198\" data-end=\"3227\"\u003e\n\u003ctd data-start=\"3198\" data-end=\"3214\" data-col-size=\"sm\"\u003eCarrying Case\u003c\/td\u003e\n\u003ctd data-start=\"3214\" data-end=\"3227\" data-col-size=\"md\"\u003eAvailable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3228\" data-end=\"3252\"\u003e\n\u003ctd data-start=\"3228\" data-end=\"3245\" data-col-size=\"sm\"\u003eReset Function\u003c\/td\u003e\n\u003ctd data-start=\"3245\" data-end=\"3252\" data-col-size=\"md\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3253\" data-end=\"3274\"\u003e\n\u003ctd data-start=\"3253\" data-end=\"3267\" data-col-size=\"sm\"\u003eDate \u0026amp; Time\u003c\/td\u003e\n\u003ctd data-start=\"3267\" data-end=\"3274\" data-col-size=\"md\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3275\" data-end=\"3311\"\u003e\n\u003ctd data-start=\"3275\" data-end=\"3284\" data-col-size=\"sm\"\u003eMemory\u003c\/td\u003e\n\u003ctd data-start=\"3284\" data-end=\"3311\" data-col-size=\"md\"\u003eUp to 100 Data Readings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3312\" data-end=\"3342\"\u003e\n\u003ctd data-start=\"3312\" data-end=\"3324\" data-col-size=\"sm\"\u003eConnector\u003c\/td\u003e\n\u003ctd data-start=\"3324\" data-end=\"3342\" data-col-size=\"md\"\u003e6-pin Mini-DIN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3343\" data-end=\"3376\"\u003e\n\u003ctd data-start=\"3343\" data-end=\"3359\" data-col-size=\"sm\"\u003eCommunication\u003c\/td\u003e\n\u003ctd data-start=\"3359\" data-end=\"3376\" data-col-size=\"md\"\u003eUSB Interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3377\" data-end=\"3440\"\u003e\n\u003ctd data-start=\"3377\" data-end=\"3392\" data-col-size=\"sm\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd data-start=\"3392\" data-end=\"3440\" data-col-size=\"md\"\u003e3 × 1.5V AA Batteries or 5V DC Power Adaptor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3441\" data-end=\"3483\"\u003e\n\u003ctd data-start=\"3441\" data-end=\"3462\" data-col-size=\"sm\"\u003eDimensions (L×W×H)\u003c\/td\u003e\n\u003ctd data-start=\"3462\" data-end=\"3483\" data-col-size=\"md\"\u003e345 × 85 × 300 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3484\" data-end=\"3501\"\u003e\n\u003ctd data-start=\"3484\" data-end=\"3493\" data-col-size=\"sm\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-start=\"3493\" data-end=\"3501\" data-col-size=\"md\"\u003e1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 data-start=\"3503\" data-end=\"3518\"\u003eApplications\u003c\/h3\u003e\n\u003cp data-start=\"3520\" data-end=\"3761\"\u003ePortable water quality testing\u003cbr data-start=\"3550\" data-end=\"3553\"\u003eEnvironmental and wastewater monitoring\u003cbr data-start=\"3592\" data-end=\"3595\"\u003eAquaculture and fisheries\u003cbr data-start=\"3620\" data-end=\"3623\"\u003eIndustrial process water analysis\u003cbr data-start=\"3656\" data-end=\"3659\"\u003eEducational and research laboratories\u003cbr data-start=\"3696\" data-end=\"3699\"\u003eFood and beverage processing\u003cbr data-start=\"3727\" data-end=\"3730\"\u003eField dissolved oxygen analysis\u003c\/p\u003e","brand":"Labman","offers":[{"title":"Default Title","offer_id":49973066793197,"sku":null,"price":40000.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5672\/6765\/files\/LMDO4P.webp?v=1778963430"},{"product_id":"online-ph-controller-oph11-4-20ma-output-rs485-communication","title":"Online pH Controller OPH11 (4–20mA Output, RS485 Communication)","description":"\u003cp data-start=\"275\" data-end=\"565\"\u003eOnline pH Controller OPH11 is designed for continuous pH monitoring and process control in industrial, environmental, and water treatment applications. The controller combines accurate pH measurement with reliable signal output and communication capability for real-time monitoring systems.\u003c\/p\u003e\n\u003cp data-start=\"567\" data-end=\"899\"\u003eThe instrument supports pH, mV, and temperature measurement with automatic temperature compensation to ensure stable and accurate readings across varying process conditions. It offers 1 to 3-point calibration with auto-buffer recognition using USA and NIST buffer standards for simplified setup and reliable calibration performance.\u003c\/p\u003e\n\u003cp data-start=\"901\" data-end=\"1175\"\u003eOPH11 includes a built-in electrode diagnosis function that helps users evaluate sensor condition and determine when probe replacement is required. Adjustable alarm settings and hysteresis control improve operational safety and process management in industrial environments.\u003c\/p\u003e\n\u003cp data-start=\"1177\" data-end=\"1426\"\u003eThe controller provides 4–20mA analog signal output and RS485 communication interface for integration with PLC systems, SCADA platforms, and industrial automation networks. Detachable screw terminal connections simplify installation and maintenance.\u003c\/p\u003e\n\u003cp data-start=\"1428\" data-end=\"1632\"\u003eIts compact panel-mount design with LCD display allows easy operation and continuous monitoring in laboratories, water treatment systems, chemical plants, aquaculture, and industrial process applications.\u003c\/p\u003e\n\u003ch3 data-start=\"1634\" data-end=\"1649\"\u003eKey Features\u003c\/h3\u003e\n\u003cp data-start=\"1651\" data-end=\"2116\"\u003eContinuous online pH monitoring and control\u003cbr data-start=\"1694\" data-end=\"1697\"\u003epH, mV, and temperature measurement\u003cbr data-start=\"1732\" data-end=\"1735\"\u003e1 to 3-point calibration with auto-buffer recognition\u003cbr data-start=\"1788\" data-end=\"1791\"\u003eSupports USA and NIST buffer standards\u003cbr data-start=\"1829\" data-end=\"1832\"\u003eAutomatic temperature compensation\u003cbr data-start=\"1866\" data-end=\"1869\"\u003eElectrode diagnosis function\u003cbr data-start=\"1897\" data-end=\"1900\"\u003e4–20mA analog signal output\u003cbr data-start=\"1927\" data-end=\"1930\"\u003eRS485 communication interface\u003cbr data-start=\"1959\" data-end=\"1962\"\u003eConfigurable low and high alarm settings\u003cbr data-start=\"2002\" data-end=\"2005\"\u003eDetachable screw terminal connections\u003cbr data-start=\"2042\" data-end=\"2045\"\u003eCompact panel-mount design\u003cbr data-start=\"2071\" data-end=\"2074\"\u003eSuitable for industrial automation systems\u003c\/p\u003e\n\u003ch3 data-start=\"2118\" data-end=\"2145\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"2147\" data-end=\"2956\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"2147\" data-end=\"2176\"\u003e\n\u003ctr data-start=\"2147\" data-end=\"2176\"\u003e\n\u003cth data-start=\"2147\" data-end=\"2159\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth data-start=\"2159\" data-end=\"2176\" data-col-size=\"md\" class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"2191\" data-end=\"2956\"\u003e\n\u003ctr data-start=\"2191\" data-end=\"2223\"\u003e\n\u003ctd data-start=\"2191\" data-end=\"2202\" data-col-size=\"sm\"\u003epH Range\u003c\/td\u003e\n\u003ctd data-start=\"2202\" data-end=\"2223\" data-col-size=\"md\"\u003e-1.00 to 15.00 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2224\" data-end=\"2251\"\u003e\n\u003ctd data-start=\"2224\" data-end=\"2240\" data-col-size=\"sm\"\u003epH Resolution\u003c\/td\u003e\n\u003ctd data-start=\"2240\" data-end=\"2251\" data-col-size=\"md\"\u003e0.01 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2252\" data-end=\"2278\"\u003e\n\u003ctd data-start=\"2252\" data-end=\"2266\" data-col-size=\"sm\"\u003epH Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"2266\" data-end=\"2278\" data-col-size=\"md\"\u003e±0.01 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2279\" data-end=\"2317\"\u003e\n\u003ctd data-start=\"2279\" data-end=\"2300\" data-col-size=\"sm\"\u003eCalibration Points\u003c\/td\u003e\n\u003ctd data-start=\"2300\" data-end=\"2317\" data-col-size=\"md\"\u003e1 to 3 Points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2318\" data-end=\"2388\"\u003e\n\u003ctd data-start=\"2318\" data-end=\"2338\" data-col-size=\"sm\"\u003epH Buffer Options\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2338\" data-end=\"2388\"\u003eUSA (4.01\/7.00\/10.01) or NIST (4.01\/6.86\/9.18)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2389\" data-end=\"2412\"\u003e\n\u003ctd data-start=\"2389\" data-end=\"2400\" data-col-size=\"sm\"\u003emV Range\u003c\/td\u003e\n\u003ctd data-start=\"2400\" data-end=\"2412\" data-col-size=\"md\"\u003e±1000 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2413\" data-end=\"2437\"\u003e\n\u003ctd data-start=\"2413\" data-end=\"2429\" data-col-size=\"sm\"\u003emV Resolution\u003c\/td\u003e\n\u003ctd data-start=\"2429\" data-end=\"2437\" data-col-size=\"md\"\u003e1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2438\" data-end=\"2461\"\u003e\n\u003ctd data-start=\"2438\" data-end=\"2452\" data-col-size=\"sm\"\u003emV Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"2452\" data-end=\"2461\" data-col-size=\"md\"\u003e±1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2462\" data-end=\"2496\"\u003e\n\u003ctd data-start=\"2462\" data-end=\"2482\" data-col-size=\"sm\"\u003eTemperature Range\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2482\" data-end=\"2496\"\u003e0 to 100°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2497\" data-end=\"2531\"\u003e\n\u003ctd data-start=\"2497\" data-end=\"2522\" data-col-size=\"sm\"\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd data-start=\"2522\" data-end=\"2531\" data-col-size=\"md\"\u003e0.1°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2532\" data-end=\"2563\"\u003e\n\u003ctd data-start=\"2532\" data-end=\"2555\" data-col-size=\"sm\"\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"2555\" data-end=\"2563\" data-col-size=\"md\"\u003e±1°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2564\" data-end=\"2591\"\u003e\n\u003ctd data-start=\"2564\" data-end=\"2580\" data-col-size=\"sm\"\u003eSignal Output\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2580\" data-end=\"2591\"\u003e4–20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2592\" data-end=\"2644\"\u003e\n\u003ctd data-start=\"2592\" data-end=\"2611\" data-col-size=\"sm\"\u003eLow \/ High Alarm\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2611\" data-end=\"2644\"\u003e0.00 to 14.00 pH (Selectable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2645\" data-end=\"2680\"\u003e\n\u003ctd data-start=\"2645\" data-end=\"2671\" data-col-size=\"sm\"\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2671\" data-end=\"2680\"\u003eRS485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2681\" data-end=\"2734\"\u003e\n\u003ctd data-start=\"2681\" data-end=\"2704\" data-col-size=\"sm\"\u003eConnection Terminals\u003c\/td\u003e\n\u003ctd data-start=\"2704\" data-end=\"2734\" data-col-size=\"md\"\u003eDetachable Screw Terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2735\" data-end=\"2787\"\u003e\n\u003ctd data-start=\"2735\" data-end=\"2762\" data-col-size=\"sm\"\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2762\" data-end=\"2787\"\u003e0 to 100°C, Automatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2788\" data-end=\"2868\"\u003e\n\u003ctd data-start=\"2788\" data-end=\"2815\" data-col-size=\"sm\"\u003eEnvironmental Conditions\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2815\" data-end=\"2868\"\u003eAmbient Temperature \u0026lt;50°C, Relative Humidity \u0026lt;70%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2869\" data-end=\"2894\"\u003e\n\u003ctd data-start=\"2869\" data-end=\"2884\" data-col-size=\"sm\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd data-start=\"2884\" data-end=\"2894\" data-col-size=\"md\"\u003eDC 24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2895\" data-end=\"2938\"\u003e\n\u003ctd data-start=\"2895\" data-end=\"2916\" data-col-size=\"sm\"\u003eDimensions (L×W×H)\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2916\" data-end=\"2938\"\u003e260 × 200 × 110 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2939\" data-end=\"2956\"\u003e\n\u003ctd data-start=\"2939\" data-end=\"2948\" data-col-size=\"sm\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-start=\"2948\" data-end=\"2956\" data-col-size=\"md\"\u003e1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 data-start=\"2958\" data-end=\"2973\"\u003eApplications\u003c\/h3\u003e\n\u003cp data-start=\"2975\" data-end=\"3192\"\u003eIndustrial process pH monitoring\u003cbr data-start=\"3007\" data-end=\"3010\"\u003eWater and wastewater treatment plants\u003cbr data-start=\"3047\" data-end=\"3050\"\u003eChemical processing industries\u003cbr data-start=\"3080\" data-end=\"3083\"\u003eAquaculture systems\u003cbr data-start=\"3102\" data-end=\"3105\"\u003eEnvironmental monitoring\u003cbr data-start=\"3129\" data-end=\"3132\"\u003eFood and beverage processing\u003cbr data-start=\"3160\" data-end=\"3163\"\u003eLaboratory automation systems\u003c\/p\u003e","brand":"Labman","offers":[{"title":"Default Title","offer_id":49973069938925,"sku":null,"price":35000.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5672\/6765\/files\/OPH11.webp?v=1778963470"},{"product_id":"online-conductivity-controller-ocm21-4-20ma-output-rs485-communication","title":"Online Conductivity Controller OCM21 (4–20mA Output, RS485 Communication)","description":"\u003cp data-start=\"291\" data-end=\"629\"\u003eOnline Conductivity Controller OCM21 is designed for continuous conductivity and TDS monitoring in industrial water treatment, environmental systems, and process control applications. The controller delivers stable online measurement performance with integrated communication and signal output capability for automated monitoring systems.\u003c\/p\u003e\n\u003cp data-start=\"631\" data-end=\"927\"\u003eThe instrument supports conductivity and TDS measurement across a wide measuring range with selectable cell constants, temperature coefficients, and TDS conversion factors for flexible application use. Automatic temperature compensation ensures accurate readings under varying process conditions.\u003c\/p\u003e\n\u003cp data-start=\"929\" data-end=\"1237\"\u003eOCM21 features 1 to 3-point calibration with automatic recognition of conductivity standards, simplifying setup and calibration procedures while maintaining measurement reliability. Adjustable alarm settings and hysteresis control improve process monitoring and operational safety in industrial environments.\u003c\/p\u003e\n\u003cp data-start=\"1239\" data-end=\"1511\"\u003eThe controller provides 4–20mA analog output and RS485 communication interface for integration with PLC, SCADA, and industrial automation systems. Its compact panel-mount design with LCD display allows easy operation and real-time monitoring in water quality applications.\u003c\/p\u003e\n\u003cp data-start=\"1513\" data-end=\"1754\"\u003eWith conductivity, TDS, and temperature monitoring capability, OCM21 is suitable for industrial water treatment, cooling towers, boiler systems, wastewater monitoring, aquaculture, chemical processing, and laboratory automation applications.\u003c\/p\u003e\n\u003ch3 data-start=\"1756\" data-end=\"1771\"\u003eKey Features\u003c\/h3\u003e\n\u003cp data-start=\"1773\" data-end=\"2276\"\u003eContinuous online conductivity and TDS monitoring\u003cbr data-start=\"1822\" data-end=\"1825\"\u003eWide auto-ranging conductivity measurement\u003cbr data-start=\"1867\" data-end=\"1870\"\u003e1 to 3-point conductivity calibration\u003cbr data-start=\"1907\" data-end=\"1910\"\u003eAutomatic conductivity standard recognition\u003cbr data-start=\"1953\" data-end=\"1956\"\u003eSelectable cell constant and TDS conversion factor\u003cbr data-start=\"2006\" data-end=\"2009\"\u003eAutomatic temperature compensation\u003cbr data-start=\"2043\" data-end=\"2046\"\u003e4–20mA analog signal output\u003cbr data-start=\"2073\" data-end=\"2076\"\u003eRS485 communication interface\u003cbr data-start=\"2105\" data-end=\"2108\"\u003eConfigurable high and low alarm limits\u003cbr data-start=\"2146\" data-end=\"2149\"\u003eCompact panel-mount controller design\u003cbr data-start=\"2186\" data-end=\"2189\"\u003eSuitable for industrial automation systems\u003cbr data-start=\"2231\" data-end=\"2234\"\u003eIntegrated conductivity and TDS monitoring\u003c\/p\u003e\n\u003ch3 data-start=\"2278\" data-end=\"2305\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"2307\" data-end=\"3225\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"2307\" data-end=\"2336\"\u003e\n\u003ctr data-start=\"2307\" data-end=\"2336\"\u003e\n\u003cth data-start=\"2307\" data-end=\"2319\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth data-start=\"2319\" data-end=\"2336\" data-col-size=\"md\" class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"2351\" data-end=\"3225\"\u003e\n\u003ctr data-start=\"2351\" data-end=\"2428\"\u003e\n\u003ctd data-start=\"2351\" data-end=\"2372\" data-col-size=\"sm\"\u003eConductivity Range\u003c\/td\u003e\n\u003ctd data-start=\"2372\" data-end=\"2428\" data-col-size=\"md\"\u003e0.01 to 20.00, 200.0, 2000 µS\/cm, 20.00, 200.0 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2429\" data-end=\"2508\"\u003e\n\u003ctd data-start=\"2429\" data-end=\"2466\" data-col-size=\"sm\"\u003eConductivity Resolution \u0026amp; Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"2466\" data-end=\"2508\" data-col-size=\"md\"\u003e0.001, 0.01, 0.1, 1, Accuracy ±1% F.S.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2509\" data-end=\"2588\"\u003e\n\u003ctd data-start=\"2509\" data-end=\"2523\" data-col-size=\"sm\"\u003eCalibration\u003c\/td\u003e\n\u003ctd data-start=\"2523\" data-end=\"2588\" data-col-size=\"md\"\u003e1 to 3 Points (10 µS \/ 84 µS \/ 1413 µS \/ 12.88 mS \/ 111.8 mS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2589\" data-end=\"2650\"\u003e\n\u003ctd data-start=\"2589\" data-end=\"2601\" data-col-size=\"sm\"\u003eTDS Range\u003c\/td\u003e\n\u003ctd data-start=\"2601\" data-end=\"2650\" data-col-size=\"md\"\u003e0 to 10.00, 100.0, 1000 ppm, 10.00, 200.0 ppt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2651\" data-end=\"2714\"\u003e\n\u003ctd data-start=\"2651\" data-end=\"2679\" data-col-size=\"sm\"\u003eTDS Resolution \u0026amp; Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"2679\" data-end=\"2714\" data-col-size=\"md\"\u003e0.01, 0.1, 1, Accuracy ±1% F.S.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2715\" data-end=\"2767\"\u003e\n\u003ctd data-start=\"2715\" data-end=\"2739\" data-col-size=\"sm\"\u003eTDS Conversion Factor\u003c\/td\u003e\n\u003ctd data-start=\"2739\" data-end=\"2767\" data-col-size=\"md\"\u003e0.1 to 1.0 (Default 0.5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2768\" data-end=\"2816\"\u003e\n\u003ctd data-start=\"2768\" data-end=\"2788\" data-col-size=\"sm\"\u003eTemperature Range\u003c\/td\u003e\n\u003ctd data-start=\"2788\" data-end=\"2816\" data-col-size=\"md\"\u003e0 to 100°C \/ 32 to 212°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2817\" data-end=\"2889\"\u003e\n\u003ctd data-start=\"2817\" data-end=\"2853\" data-col-size=\"sm\"\u003eTemperature Resolution \u0026amp; Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"2853\" data-end=\"2889\" data-col-size=\"md\"\u003e0.1°C\/°F, Accuracy ±1°C \/ ±1.8°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2890\" data-end=\"2935\"\u003e\n\u003ctd data-start=\"2890\" data-end=\"2916\" data-col-size=\"sm\"\u003eTemperature Coefficient\u003c\/td\u003e\n\u003ctd data-start=\"2916\" data-end=\"2935\" data-col-size=\"md\"\u003e0.0 to 10.0%\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2936\" data-end=\"2983\"\u003e\n\u003ctd data-start=\"2936\" data-end=\"2957\" data-col-size=\"sm\"\u003eOffset Calibration\u003c\/td\u003e\n\u003ctd data-start=\"2957\" data-end=\"2983\" data-col-size=\"md\"\u003e1 Point, Reading ±10°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2984\" data-end=\"3011\"\u003e\n\u003ctd data-start=\"2984\" data-end=\"3000\" data-col-size=\"sm\"\u003eSignal Output\u003c\/td\u003e\n\u003ctd data-start=\"3000\" data-end=\"3011\" data-col-size=\"md\"\u003e4–20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3012\" data-end=\"3036\"\u003e\n\u003ctd data-start=\"3012\" data-end=\"3019\" data-col-size=\"sm\"\u003eLoad\u003c\/td\u003e\n\u003ctd data-start=\"3019\" data-end=\"3036\" data-col-size=\"md\"\u003eMaximum 500 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3037\" data-end=\"3101\"\u003e\n\u003ctd data-start=\"3037\" data-end=\"3060\" data-col-size=\"sm\"\u003eHigh\/Low Limit Alarm\u003c\/td\u003e\n\u003ctd data-start=\"3060\" data-end=\"3101\" data-col-size=\"md\"\u003e0.02 µS\/cm to 20.0 mS\/cm (Selectable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3102\" data-end=\"3137\"\u003e\n\u003ctd data-start=\"3102\" data-end=\"3128\" data-col-size=\"sm\"\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd data-start=\"3128\" data-end=\"3137\" data-col-size=\"md\"\u003eRS485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3138\" data-end=\"3163\"\u003e\n\u003ctd data-start=\"3138\" data-end=\"3153\" data-col-size=\"sm\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd data-start=\"3153\" data-end=\"3163\" data-col-size=\"md\"\u003eDC 24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3164\" data-end=\"3207\"\u003e\n\u003ctd data-start=\"3164\" data-end=\"3185\" data-col-size=\"sm\"\u003eDimensions (L×W×H)\u003c\/td\u003e\n\u003ctd data-start=\"3185\" data-end=\"3207\" data-col-size=\"md\"\u003e290 × 230 × 155 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3208\" data-end=\"3225\"\u003e\n\u003ctd data-start=\"3208\" data-end=\"3217\" data-col-size=\"sm\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-start=\"3217\" data-end=\"3225\" data-col-size=\"md\"\u003e1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 data-start=\"3227\" data-end=\"3242\"\u003eApplications\u003c\/h3\u003e\n\u003cp data-start=\"3244\" data-end=\"3472\"\u003eIndustrial water treatment systems\u003cbr data-start=\"3278\" data-end=\"3281\"\u003eCooling tower monitoring\u003cbr data-start=\"3305\" data-end=\"3308\"\u003eBoiler water conductivity control\u003cbr data-start=\"3341\" data-end=\"3344\"\u003eWastewater treatment plants\u003cbr data-start=\"3371\" data-end=\"3374\"\u003eAquaculture and hydroponics\u003cbr data-start=\"3401\" data-end=\"3404\"\u003eChemical process industries\u003cbr data-start=\"3431\" data-end=\"3434\"\u003eOnline TDS and conductivity monitoring\u003c\/p\u003e","brand":"Labman","offers":[{"title":"Default Title","offer_id":49973076689133,"sku":null,"price":36500.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5672\/6765\/files\/OCM21.webp?v=1778963517"}],"url":"https:\/\/www.biotronscientific.com\/collections\/water-quality-analytical-meters.oembed","provider":"BIOTRON","version":"1.0","type":"link"}