{"title":"Titrators","description":null,"products":[{"product_id":"potential-titrator-apt1800-det-met-set-mat-0-01-ph-accuracy","title":"Potential Titrator APT1800 (DET\/MET\/SET\/MAT, ±0.01 pH Accuracy)","description":"\u003cp data-start=\"285\" data-end=\"1030\"\u003eAutomatic Potential Titrator APT1800 is designed for precise and automated titration analysis in laboratory environments. It supports multiple titration modes including dynamic equivalence point, monotone equivalence point, preset endpoint and manual titration, enabling flexibility across different analytical methods. The system features a high-accuracy burette with selectable volumes, ensuring precise reagent delivery. With integrated pH and mV measurement capabilities, temperature compensation and data storage, it delivers reliable and repeatable results. The LCD interface provides detailed visualization of titration curves and results, while connectivity options allow seamless data transfer and integration into laboratory workflows.\u003c\/p\u003e\n\u003ch3 data-start=\"1032\" data-end=\"1049\"\u003eKey Features\u003c\/h3\u003e\n\u003cp data-start=\"1050\" data-end=\"1680\"\u003eSupports DET, MET, SET and MAT titration modes\u003cbr data-start=\"1096\" data-end=\"1099\"\u003eHigh precision burette system with selectable 10 ml and 20 ml options\u003cbr data-start=\"1168\" data-end=\"1171\"\u003eAccurate pH and mV measurement with fine resolution\u003cbr data-start=\"1222\" data-end=\"1225\"\u003eLCD display for real-time curve and result visualization\u003cbr data-start=\"1281\" data-end=\"1284\"\u003eAutomatic titration with repeatable and consistent results\u003cbr data-start=\"1342\" data-end=\"1345\"\u003eData storage up to 50 titration sets\u003cbr data-start=\"1381\" data-end=\"1384\"\u003eIntegrated stirring function for uniform mixing\u003cbr data-start=\"1431\" data-end=\"1434\"\u003eTemperature measurement and compensation support\u003cbr data-start=\"1482\" data-end=\"1485\"\u003eRS232 and USB interface for data connectivity\u003cbr data-start=\"1530\" data-end=\"1533\"\u003eHigh resolution dosing mechanism for precise control\u003cbr data-start=\"1585\" data-end=\"1588\"\u003eGMP compliant data handling system\u003cbr data-start=\"1622\" data-end=\"1625\"\u003eSuitable for automated analytical titration workflows\u003c\/p\u003e\n\u003ch3 data-start=\"1682\" data-end=\"1711\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"1712\" data-end=\"2584\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"1712\" data-end=\"1741\"\u003e\n\u003ctr data-start=\"1712\" data-end=\"1741\"\u003e\n\u003cth data-start=\"1712\" data-end=\"1724\" data-col-size=\"sm\" class=\"\"\u003eParameter\u003c\/th\u003e\n\u003cth data-start=\"1724\" data-end=\"1741\" data-col-size=\"md\" class=\"\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"1752\" data-end=\"2584\"\u003e\n\u003ctr data-start=\"1752\" data-end=\"1801\"\u003e\n\u003ctd data-start=\"1752\" data-end=\"1769\" data-col-size=\"sm\"\u003eEquipment Type\u003c\/td\u003e\n\u003ctd data-start=\"1769\" data-end=\"1801\" data-col-size=\"md\"\u003eAutomatic Potential Titrator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1802\" data-end=\"1821\"\u003e\n\u003ctd data-start=\"1802\" data-end=\"1810\" data-col-size=\"sm\"\u003eModel\u003c\/td\u003e\n\u003ctd data-start=\"1810\" data-end=\"1821\" data-col-size=\"md\"\u003eAPT1800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1822\" data-end=\"1862\"\u003e\n\u003ctd data-start=\"1822\" data-end=\"1840\" data-col-size=\"sm\"\u003eTitration Modes\u003c\/td\u003e\n\u003ctd data-start=\"1840\" data-end=\"1862\" data-col-size=\"md\"\u003eDET, MET, SET, MAT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1863\" data-end=\"1903\"\u003e\n\u003ctd data-start=\"1863\" data-end=\"1890\" data-col-size=\"sm\"\u003eBurette Accuracy (10 ml)\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"1890\" data-end=\"1903\"\u003e±0.025 ml\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1904\" data-end=\"1944\"\u003e\n\u003ctd data-start=\"1904\" data-end=\"1931\" data-col-size=\"sm\"\u003eBurette Accuracy (20 ml)\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"1931\" data-end=\"1944\"\u003e±0.035 ml\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1945\" data-end=\"1981\"\u003e\n\u003ctd data-start=\"1945\" data-end=\"1966\" data-col-size=\"sm\"\u003eBurette Resolution\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"1966\" data-end=\"1981\"\u003e1 µl \/ 2 µl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1982\" data-end=\"2006\"\u003e\n\u003ctd data-start=\"1982\" data-end=\"1998\" data-col-size=\"sm\"\u003eRepeatability\u003c\/td\u003e\n\u003ctd data-start=\"1998\" data-end=\"2006\" data-col-size=\"md\"\u003e0.2%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2007\" data-end=\"2032\"\u003e\n\u003ctd data-start=\"2007\" data-end=\"2018\" data-col-size=\"sm\"\u003emV Range\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2018\" data-end=\"2032\"\u003e±1800.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2033\" data-end=\"2059\"\u003e\n\u003ctd data-start=\"2033\" data-end=\"2049\" data-col-size=\"sm\"\u003emV Resolution\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2049\" data-end=\"2059\"\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2060\" data-end=\"2087\"\u003e\n\u003ctd data-start=\"2060\" data-end=\"2074\" data-col-size=\"sm\"\u003emV Accuracy\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2074\" data-end=\"2087\"\u003e±0.05% FS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2088\" data-end=\"2118\"\u003e\n\u003ctd data-start=\"2088\" data-end=\"2099\" data-col-size=\"sm\"\u003epH Range\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2099\" data-end=\"2118\"\u003e0.00 – 14.00 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2119\" data-end=\"2146\"\u003e\n\u003ctd data-start=\"2119\" data-end=\"2135\" data-col-size=\"sm\"\u003epH Resolution\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2135\" data-end=\"2146\"\u003e0.01 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2147\" data-end=\"2173\"\u003e\n\u003ctd data-start=\"2147\" data-end=\"2161\" data-col-size=\"sm\"\u003epH Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"2161\" data-end=\"2173\" data-col-size=\"md\"\u003e±0.01 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2174\" data-end=\"2209\"\u003e\n\u003ctd data-start=\"2174\" data-end=\"2194\" data-col-size=\"sm\"\u003eTemperature Range\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2194\" data-end=\"2209\"\u003eUp to 105°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2210\" data-end=\"2244\"\u003e\n\u003ctd data-start=\"2210\" data-end=\"2235\" data-col-size=\"sm\"\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2235\" data-end=\"2244\"\u003e0.1°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2245\" data-end=\"2278\"\u003e\n\u003ctd data-start=\"2245\" data-end=\"2268\" data-col-size=\"sm\"\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"2268\" data-end=\"2278\" data-col-size=\"md\"\u003e±0.3°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2279\" data-end=\"2296\"\u003e\n\u003ctd data-start=\"2279\" data-end=\"2289\" data-col-size=\"sm\"\u003eDisplay\u003c\/td\u003e\n\u003ctd data-start=\"2289\" data-end=\"2296\" data-col-size=\"md\"\u003eLCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2297\" data-end=\"2324\"\u003e\n\u003ctd data-start=\"2297\" data-end=\"2317\" data-col-size=\"sm\"\u003eStirring Function\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2317\" data-end=\"2324\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2325\" data-end=\"2351\"\u003e\n\u003ctd data-start=\"2325\" data-end=\"2340\" data-col-size=\"sm\"\u003eData Storage\u003c\/td\u003e\n\u003ctd data-start=\"2340\" data-end=\"2351\" data-col-size=\"md\"\u003e50 sets\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2352\" data-end=\"2383\"\u003e\n\u003ctd data-start=\"2352\" data-end=\"2368\" data-col-size=\"sm\"\u003eCommunication\u003c\/td\u003e\n\u003ctd data-start=\"2368\" data-end=\"2383\" data-col-size=\"md\"\u003eRS232C, USB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2384\" data-end=\"2417\"\u003e\n\u003ctd data-start=\"2384\" data-end=\"2399\" data-col-size=\"sm\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd data-start=\"2399\" data-end=\"2417\" data-col-size=\"md\"\u003eAC 220V \/ 50Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2418\" data-end=\"2453\"\u003e\n\u003ctd data-start=\"2418\" data-end=\"2431\" data-col-size=\"sm\"\u003eDimensions\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2431\" data-end=\"2453\"\u003e540 × 495 × 480 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2454\" data-end=\"2480\"\u003e\n\u003ctd data-start=\"2454\" data-end=\"2463\" data-col-size=\"sm\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2463\" data-end=\"2480\"\u003eApprox. 10 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2481\" data-end=\"2527\"\u003e\n\u003ctd data-start=\"2481\" data-end=\"2495\" data-col-size=\"sm\"\u003eApplication\u003c\/td\u003e\n\u003ctd data-start=\"2495\" data-end=\"2527\" data-col-size=\"md\"\u003eAutomated titration analysis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2528\" data-end=\"2584\"\u003e\n\u003ctd data-start=\"2528\" data-end=\"2536\" data-col-size=\"sm\"\u003eUsage\u003c\/td\u003e\n\u003ctd data-start=\"2536\" data-end=\"2584\" data-col-size=\"md\"\u003eChemical analysis, quality control workflows\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Labman","offers":[{"title":"Default Title","offer_id":49822427644141,"sku":null,"price":400000.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5672\/6765\/files\/APT1800.webp?v=1776975169"},{"product_id":"karl-fischer-titrator-kft250vc-volumetric-coulometric-0-1-mg-250-mg","title":"Karl Fischer Titrator KFT250VC (Volumetric \u0026 Coulometric, 0.1 mg–250 mg)","description":"\u003cp data-start=\"283\" data-end=\"916\"\u003eKarl Fischer Titrator KFT250VC is designed for precise determination of moisture content using both volumetric and coulometric titration methods. It enables flexible analysis across a wide range of sample types, from trace moisture to higher concentration levels. The system incorporates automatic and manual drift correction to ensure accurate results, along with configurable parameters for titration control. With LCD interface, data storage and multiple unit selection, it provides reliable and repeatable moisture analysis. The integrated system supports safe reagent handling and consistent performance in analytical workflows.\u003c\/p\u003e\n\u003ch3 data-start=\"918\" data-end=\"935\"\u003eKey Features\u003c\/h3\u003e\n\u003cp data-start=\"936\" data-end=\"1471\"\u003eSupports both volumetric and coulometric titration methods\u003cbr data-start=\"994\" data-end=\"997\"\u003eWide moisture analysis range from trace to higher concentrations\u003cbr data-start=\"1061\" data-end=\"1064\"\u003eAutomatic and manual drift correction for improved accuracy\u003cbr data-start=\"1123\" data-end=\"1126\"\u003eData storage capacity up to 200 test results\u003cbr data-start=\"1170\" data-end=\"1173\"\u003eLCD display for real-time data and curve visualization\u003cbr data-start=\"1227\" data-end=\"1230\"\u003eSelectable units including mg, mg\/L, %, ppm\u003cbr data-start=\"1273\" data-end=\"1276\"\u003eConfigurable parameters for titration control\u003cbr data-start=\"1321\" data-end=\"1324\"\u003eHigh repeatability and measurement stability\u003cbr data-start=\"1368\" data-end=\"1371\"\u003eRS232 interface for data communication\u003cbr data-start=\"1409\" data-end=\"1412\"\u003eIntegrated system for safe reagent handling and operation\u003c\/p\u003e\n\u003ch3 data-start=\"1473\" data-end=\"1502\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"1503\" data-end=\"2297\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"1503\" data-end=\"1532\"\u003e\n\u003ctr data-start=\"1503\" data-end=\"1532\"\u003e\n\u003cth data-start=\"1503\" data-end=\"1515\" data-col-size=\"sm\" class=\"\"\u003eParameter\u003c\/th\u003e\n\u003cth data-start=\"1515\" data-end=\"1532\" data-col-size=\"md\" class=\"\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"1543\" data-end=\"2297\"\u003e\n\u003ctr data-start=\"1543\" data-end=\"1585\"\u003e\n\u003ctd data-start=\"1543\" data-end=\"1560\" data-col-size=\"sm\"\u003eEquipment Type\u003c\/td\u003e\n\u003ctd data-start=\"1560\" data-end=\"1585\" data-col-size=\"md\"\u003eKarl Fischer Titrator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1586\" data-end=\"1606\"\u003e\n\u003ctd data-start=\"1586\" data-end=\"1594\" data-col-size=\"sm\"\u003eModel\u003c\/td\u003e\n\u003ctd data-start=\"1594\" data-end=\"1606\" data-col-size=\"md\"\u003eKFT250VC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1607\" data-end=\"1652\"\u003e\n\u003ctd data-start=\"1607\" data-end=\"1624\" data-col-size=\"sm\"\u003eTitration Mode\u003c\/td\u003e\n\u003ctd data-start=\"1624\" data-end=\"1652\" data-col-size=\"md\"\u003eVolumetric \u0026amp; Coulometric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1653\" data-end=\"1691\"\u003e\n\u003ctd data-start=\"1653\" data-end=\"1672\" data-col-size=\"sm\"\u003eVolumetric Range\u003c\/td\u003e\n\u003ctd data-start=\"1672\" data-end=\"1691\" data-col-size=\"md\"\u003e0.1 mg – 250 mg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1692\" data-end=\"1728\"\u003e\n\u003ctd data-start=\"1692\" data-end=\"1719\" data-col-size=\"sm\"\u003eVolumetric Repeatability\u003c\/td\u003e\n\u003ctd data-start=\"1719\" data-end=\"1728\" data-col-size=\"md\"\u003e±0.5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1729\" data-end=\"1796\"\u003e\n\u003ctd data-start=\"1729\" data-end=\"1772\" data-col-size=\"sm\"\u003eVolumetric Polarization Current Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"1772\" data-end=\"1796\" data-col-size=\"md\"\u003e1µA±0.2µA, 50µA±10µA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1797\" data-end=\"1834\"\u003e\n\u003ctd data-start=\"1797\" data-end=\"1817\" data-col-size=\"sm\"\u003eCoulometric Range\u003c\/td\u003e\n\u003ctd data-start=\"1817\" data-end=\"1834\" data-col-size=\"md\"\u003e10 µg – 20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1835\" data-end=\"1901\"\u003e\n\u003ctd data-start=\"1835\" data-end=\"1870\" data-col-size=\"sm\"\u003eCoulometric Electrolytic Current\u003c\/td\u003e\n\u003ctd data-start=\"1870\" data-end=\"1901\" data-col-size=\"md\"\u003e10 mA, 20 mA, 50 mA, 100 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1902\" data-end=\"1941\"\u003e\n\u003ctd data-start=\"1902\" data-end=\"1925\" data-col-size=\"sm\"\u003eCoulometric Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"1925\" data-end=\"1941\" data-col-size=\"md\"\u003e±(5% + 3) µg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1942\" data-end=\"1965\"\u003e\n\u003ctd data-start=\"1942\" data-end=\"1958\" data-col-size=\"sm\"\u003eRepeatability\u003c\/td\u003e\n\u003ctd data-start=\"1958\" data-end=\"1965\" data-col-size=\"md\"\u003e≤3%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1966\" data-end=\"1983\"\u003e\n\u003ctd data-start=\"1966\" data-end=\"1976\" data-col-size=\"sm\"\u003eDisplay\u003c\/td\u003e\n\u003ctd data-start=\"1976\" data-end=\"1983\" data-col-size=\"md\"\u003eLCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1984\" data-end=\"2010\"\u003e\n\u003ctd data-start=\"1984\" data-end=\"1993\" data-col-size=\"sm\"\u003eMemory\u003c\/td\u003e\n\u003ctd data-start=\"1993\" data-end=\"2010\" data-col-size=\"md\"\u003e200 data sets\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2011\" data-end=\"2039\"\u003e\n\u003ctd data-start=\"2011\" data-end=\"2019\" data-col-size=\"sm\"\u003eUnits\u003c\/td\u003e\n\u003ctd data-start=\"2019\" data-end=\"2039\" data-col-size=\"md\"\u003emg, mg\/L, %, ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2040\" data-end=\"2081\"\u003e\n\u003ctd data-start=\"2040\" data-end=\"2059\" data-col-size=\"sm\"\u003eDrift Correction\u003c\/td\u003e\n\u003ctd data-start=\"2059\" data-end=\"2081\" data-col-size=\"md\"\u003eAutomatic \/ Manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2082\" data-end=\"2107\"\u003e\n\u003ctd data-start=\"2082\" data-end=\"2098\" data-col-size=\"sm\"\u003eCommunication\u003c\/td\u003e\n\u003ctd data-start=\"2098\" data-end=\"2107\" data-col-size=\"md\"\u003eRS232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2108\" data-end=\"2141\"\u003e\n\u003ctd data-start=\"2108\" data-end=\"2123\" data-col-size=\"sm\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd data-start=\"2123\" data-end=\"2141\" data-col-size=\"md\"\u003eAC 220V \/ 50Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2142\" data-end=\"2177\"\u003e\n\u003ctd data-start=\"2142\" data-end=\"2155\" data-col-size=\"sm\"\u003eDimensions\u003c\/td\u003e\n\u003ctd data-start=\"2155\" data-end=\"2177\" data-col-size=\"md\"\u003e535 × 500 × 480 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2178\" data-end=\"2204\"\u003e\n\u003ctd data-start=\"2178\" data-end=\"2187\" data-col-size=\"sm\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-start=\"2187\" data-end=\"2204\" data-col-size=\"md\"\u003eApprox. 13 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2205\" data-end=\"2240\"\u003e\n\u003ctd data-start=\"2205\" data-end=\"2219\" data-col-size=\"sm\"\u003eApplication\u003c\/td\u003e\n\u003ctd data-start=\"2219\" data-end=\"2240\" data-col-size=\"md\"\u003eMoisture analysis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2241\" data-end=\"2297\"\u003e\n\u003ctd data-start=\"2241\" data-end=\"2249\" data-col-size=\"sm\"\u003eUsage\u003c\/td\u003e\n\u003ctd data-start=\"2249\" data-end=\"2297\" data-col-size=\"md\"\u003eChemical analysis, quality control workflows\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Labman","offers":[{"title":"Default Title","offer_id":49822461329645,"sku":null,"price":488000.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5672\/6765\/files\/KFT250VC.jpg?v=1776975432"},{"product_id":"automatic-potentiometric-titrator-apt2000t-7-touch-screen-10-ml-20-ml-burette-multi-mode-titration","title":"Automatic Potentiometric Titrator – APT2000T (7\" Touch Screen | 10 ml \/ 20 ml Burette | Multi-Mode Titration)","description":"\u003cp data-start=\"571\" data-end=\"934\"\u003eAPT2000T Automatic Potentiometric Titrator is designed for precise and automated volumetric analysis in research laboratories, pharmaceutical industries, food testing laboratories and quality control environments. The instrument features a 7-inch color touch screen that displays titration methods, curves and results in real time for easy operation and analysis.\u003c\/p\u003e\n\u003cp data-start=\"936\" data-end=\"1286\"\u003eThe system supports Dynamic Endpoint Titration (DET), Monotone Endpoint Titration (MET), Preset Endpoint Titration (SET) and Manual Titration (MAT), making it suitable for a wide variety of analytical applications. High-precision replaceable burettes are available in 10 ml and 20 ml capacities, providing excellent dosing accuracy and repeatability.\u003c\/p\u003e\n\u003cp data-start=\"1288\" data-end=\"1541\"\u003eAPT2000T supports acid-base, non-aqueous acid-base, redox, precipitation and complex titrations. Advanced formula editing allows customized calculations and result reporting. Data can be exported through RS232C and USB interfaces in CSV and PDF formats.\u003c\/p\u003e\n\u003cp data-start=\"1543\" data-end=\"1769\"\u003eWith password protection, GLP-compliant memory storage for up to 1000 data sets and support for pH calibration and measurement, APT2000T delivers reliable and efficient titration performance for modern analytical laboratories.\u003c\/p\u003e\n\u003ch3 data-start=\"1771\" data-end=\"1786\"\u003eKey Features\u003c\/h3\u003e\n\u003cp data-start=\"1788\" data-end=\"1821\"\u003e7-inch color touch screen display\u003c\/p\u003e\n\u003cp data-start=\"1823\" data-end=\"1872\"\u003eReal-time display of titration curves and results\u003c\/p\u003e\n\u003cp data-start=\"1874\" data-end=\"1893\"\u003ePassword protection\u003c\/p\u003e\n\u003cp data-start=\"1895\" data-end=\"1928\"\u003eHigh-accuracy replaceable burette\u003c\/p\u003e\n\u003cp data-start=\"1930\" data-end=\"1965\"\u003eSelectable 10 ml and 20 ml burettes\u003c\/p\u003e\n\u003cp data-start=\"1967\" data-end=\"2005\"\u003eAcid and alkali resistant burette line\u003c\/p\u003e\n\u003cp data-start=\"2007\" data-end=\"2038\"\u003eUpper and lower stirrer support\u003c\/p\u003e\n\u003cp data-start=\"2040\" data-end=\"2072\"\u003eDynamic Endpoint Titration (DET)\u003c\/p\u003e\n\u003cp data-start=\"2074\" data-end=\"2107\"\u003eMonotone Endpoint Titration (MET)\u003c\/p\u003e\n\u003cp data-start=\"2109\" data-end=\"2140\"\u003ePreset Endpoint Titration (SET)\u003c\/p\u003e\n\u003cp data-start=\"2142\" data-end=\"2164\"\u003eManual Titration (MAT)\u003c\/p\u003e\n\u003cp data-start=\"2166\" data-end=\"2182\"\u003eConstant pH mode\u003c\/p\u003e\n\u003cp data-start=\"2184\" data-end=\"2204\"\u003eBlank titration mode\u003c\/p\u003e\n\u003cp data-start=\"2206\" data-end=\"2230\"\u003e1 to 3-point calibration\u003c\/p\u003e\n\u003cp data-start=\"2232\" data-end=\"2262\"\u003epH calibration and measurement\u003c\/p\u003e\n\u003cp data-start=\"2264\" data-end=\"2291\"\u003eSelectable pH buffer groups\u003c\/p\u003e\n\u003cp data-start=\"2293\" data-end=\"2316\"\u003eAdvanced formula editor\u003c\/p\u003e\n\u003cp data-start=\"2318\" data-end=\"2345\"\u003eCustomized result reporting\u003c\/p\u003e\n\u003cp data-start=\"2347\" data-end=\"2370\"\u003eCSV and PDF data export\u003c\/p\u003e\n\u003cp data-start=\"2372\" data-end=\"2397\"\u003eRS232C and USB interfaces\u003c\/p\u003e\n\u003cp data-start=\"2399\" data-end=\"2418\"\u003eAcid-base titration\u003c\/p\u003e\n\u003cp data-start=\"2420\" data-end=\"2451\"\u003eNon-aqueous acid-base titration\u003c\/p\u003e\n\u003cp data-start=\"2453\" data-end=\"2468\"\u003eRedox titration\u003c\/p\u003e\n\u003cp data-start=\"2470\" data-end=\"2493\"\u003ePrecipitation titration\u003c\/p\u003e\n\u003cp data-start=\"2495\" data-end=\"2519\"\u003eComplexometric titration\u003c\/p\u003e\n\u003cp data-start=\"2521\" data-end=\"2560\"\u003eStorage of 1000 GLP-compliant data sets\u003c\/p\u003e\n\u003cp data-start=\"2562\" data-end=\"2596\"\u003e21 CFR software support (optional)\u003c\/p\u003e\n\u003ch3 data-start=\"2598\" data-end=\"2625\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"2627\" data-end=\"3575\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"2627\" data-end=\"2651\"\u003e\n\u003ctr data-start=\"2627\" data-end=\"2651\"\u003e\n\u003cth data-start=\"2627\" data-end=\"2639\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth data-start=\"2639\" data-end=\"2651\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eAPT2000T\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"2679\" data-end=\"3575\"\u003e\n\u003ctr data-start=\"2679\" data-end=\"2719\"\u003e\n\u003ctd data-start=\"2679\" data-end=\"2697\" data-col-size=\"sm\"\u003eTitration Modes\u003c\/td\u003e\n\u003ctd data-start=\"2697\" data-end=\"2719\" data-col-size=\"sm\"\u003eDET, MET, SET, MAT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2720\" data-end=\"2764\"\u003e\n\u003ctd data-start=\"2720\" data-end=\"2756\" data-col-size=\"sm\"\u003eBurette Titrimetric Repeatability\u003c\/td\u003e\n\u003ctd data-start=\"2756\" data-end=\"2764\" data-col-size=\"sm\"\u003e0.2%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2765\" data-end=\"2803\"\u003e\n\u003ctd data-start=\"2765\" data-end=\"2790\" data-col-size=\"sm\"\u003e10 ml Burette Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"2790\" data-end=\"2803\" data-col-size=\"sm\"\u003e±0.025 ml\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2804\" data-end=\"2842\"\u003e\n\u003ctd data-start=\"2804\" data-end=\"2829\" data-col-size=\"sm\"\u003e20 ml Burette Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"2829\" data-end=\"2842\" data-col-size=\"sm\"\u003e±0.035 ml\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2843\" data-end=\"2878\"\u003e\n\u003ctd data-start=\"2843\" data-end=\"2870\" data-col-size=\"sm\"\u003e10 ml Burette Resolution\u003c\/td\u003e\n\u003ctd data-start=\"2870\" data-end=\"2878\" data-col-size=\"sm\"\u003e1 μl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2879\" data-end=\"2914\"\u003e\n\u003ctd data-start=\"2879\" data-end=\"2906\" data-col-size=\"sm\"\u003e20 ml Burette Resolution\u003c\/td\u003e\n\u003ctd data-start=\"2906\" data-end=\"2914\" data-col-size=\"sm\"\u003e2 μl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2915\" data-end=\"2957\"\u003e\n\u003ctd data-start=\"2915\" data-end=\"2936\" data-col-size=\"sm\"\u003emV Measuring Range\u003c\/td\u003e\n\u003ctd data-start=\"2936\" data-end=\"2957\" data-col-size=\"sm\"\u003e-2000 to +2000 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2958\" data-end=\"2984\"\u003e\n\u003ctd data-start=\"2958\" data-end=\"2974\" data-col-size=\"sm\"\u003emV Resolution\u003c\/td\u003e\n\u003ctd data-start=\"2974\" data-end=\"2984\" data-col-size=\"sm\"\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2985\" data-end=\"3026\"\u003e\n\u003ctd data-start=\"2985\" data-end=\"3002\" data-col-size=\"sm\"\u003emV Fluctuation\u003c\/td\u003e\n\u003ctd data-start=\"3002\" data-end=\"3026\" data-col-size=\"sm\"\u003e±0.3 mV ±1 bit \/ 3 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3027\" data-end=\"3053\"\u003e\n\u003ctd data-start=\"3027\" data-end=\"3041\" data-col-size=\"sm\"\u003emV Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"3041\" data-end=\"3053\" data-col-size=\"sm\"\u003e±0.01 FS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3054\" data-end=\"3098\"\u003e\n\u003ctd data-start=\"3054\" data-end=\"3075\" data-col-size=\"sm\"\u003epH Measuring Range\u003c\/td\u003e\n\u003ctd data-start=\"3075\" data-end=\"3098\" data-col-size=\"sm\"\u003e-2.000 to 20.000 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3099\" data-end=\"3127\"\u003e\n\u003ctd data-start=\"3099\" data-end=\"3115\" data-col-size=\"sm\"\u003epH Resolution\u003c\/td\u003e\n\u003ctd data-start=\"3115\" data-end=\"3127\" data-col-size=\"sm\"\u003e0.001 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3128\" data-end=\"3155\"\u003e\n\u003ctd data-start=\"3128\" data-end=\"3142\" data-col-size=\"sm\"\u003epH Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"3142\" data-end=\"3155\" data-col-size=\"sm\"\u003e±0.005 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3156\" data-end=\"3196\"\u003e\n\u003ctd data-start=\"3156\" data-end=\"3185\" data-col-size=\"sm\"\u003eMechanical Unit Resolution\u003c\/td\u003e\n\u003ctd data-start=\"3185\" data-end=\"3196\" data-col-size=\"sm\"\u003e1\/50000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3197\" data-end=\"3234\"\u003e\n\u003ctd data-start=\"3197\" data-end=\"3217\" data-col-size=\"sm\"\u003eTemperature Range\u003c\/td\u003e\n\u003ctd data-start=\"3217\" data-end=\"3234\" data-col-size=\"sm\"\u003e-5°C to 110°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3235\" data-end=\"3269\"\u003e\n\u003ctd data-start=\"3235\" data-end=\"3260\" data-col-size=\"sm\"\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd data-start=\"3260\" data-end=\"3269\" data-col-size=\"sm\"\u003e0.1°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3270\" data-end=\"3303\"\u003e\n\u003ctd data-start=\"3270\" data-end=\"3293\" data-col-size=\"sm\"\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"3293\" data-end=\"3303\" data-col-size=\"sm\"\u003e±0.2°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3304\" data-end=\"3337\"\u003e\n\u003ctd data-start=\"3304\" data-end=\"3314\" data-col-size=\"sm\"\u003eDisplay\u003c\/td\u003e\n\u003ctd data-start=\"3314\" data-end=\"3337\" data-col-size=\"sm\"\u003e7-inch Touch Screen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3338\" data-end=\"3362\"\u003e\n\u003ctd data-start=\"3338\" data-end=\"3355\" data-col-size=\"sm\"\u003eGMP Compliance\u003c\/td\u003e\n\u003ctd data-start=\"3355\" data-end=\"3362\" data-col-size=\"sm\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3363\" data-end=\"3390\"\u003e\n\u003ctd data-start=\"3363\" data-end=\"3383\" data-col-size=\"sm\"\u003eStirring Function\u003c\/td\u003e\n\u003ctd data-start=\"3383\" data-end=\"3390\" data-col-size=\"sm\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3391\" data-end=\"3427\"\u003e\n\u003ctd data-start=\"3391\" data-end=\"3412\" data-col-size=\"sm\"\u003eCommunication Port\u003c\/td\u003e\n\u003ctd data-start=\"3412\" data-end=\"3427\" data-col-size=\"sm\"\u003eRS232C, USB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3428\" data-end=\"3464\"\u003e\n\u003ctd data-start=\"3428\" data-end=\"3446\" data-col-size=\"sm\"\u003eMemory Capacity\u003c\/td\u003e\n\u003ctd data-start=\"3446\" data-end=\"3464\" data-col-size=\"sm\"\u003e1000 Data Sets\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3465\" data-end=\"3498\"\u003e\n\u003ctd data-start=\"3465\" data-end=\"3480\" data-col-size=\"sm\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd data-start=\"3480\" data-end=\"3498\" data-col-size=\"sm\"\u003eAC 220V \/ 50Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3499\" data-end=\"3550\"\u003e\n\u003ctd data-start=\"3499\" data-end=\"3528\" data-col-size=\"sm\"\u003ePacking Dimensions (L×W×H)\u003c\/td\u003e\n\u003ctd data-start=\"3528\" data-end=\"3550\" data-col-size=\"sm\"\u003e540 × 495 × 480 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3551\" data-end=\"3575\"\u003e\n\u003ctd data-start=\"3551\" data-end=\"3566\" data-col-size=\"sm\"\u003eGross Weight\u003c\/td\u003e\n\u003ctd data-start=\"3566\" data-end=\"3575\" data-col-size=\"sm\"\u003e10 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Labman","offers":[{"title":"Default Title","offer_id":50104709153005,"sku":null,"price":400000.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5672\/6765\/files\/APT2000T.jpg?v=1781461008"},{"product_id":"karl-fischer-titrator-kft200tc-kft250tv-coulometric-volumetric-titration-7-touch-screen-rs232c-usb","title":"Karl Fischer Titrator – KFT200TC \/ KFT250TV (Coulometric \u0026 Volumetric Titration | 7\" Touch Screen | RS232C \u0026 USB)","description":"\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eKFT200TC and KFT250TV Karl Fischer Titrators are advanced moisture analysis systems developed for accurate determination of water content in gases, liquids and solid samples. The KFT200TC employs the coulometric Karl Fischer principle for trace moisture measurement, while the KFT250TV utilizes volumetric Karl Fischer titration for higher moisture concentrations.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eBoth instruments feature a 7-inch LCD touch screen with intuitive operation and support multiple titration methods. Automatic and manual drift adjustment ensures accurate results, while GLP-compliant data management allows storage of up to 200 results. Data can be exported through USB and RS232C interfaces in CSV format.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eKFT200TC supports Auto Titration Method, Oven Titration Method, Oven Blank Titration Method and Coefficient Correction Method. KFT250TV additionally supports KF Titer Determination Method. Optional oven sampling capability enables constant moisture and trace moisture analysis for gas, liquid and solid samples.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eDesigned for pharmaceutical laboratories, petrochemical industries, food testing laboratories and research institutions, KFT200TC and KFT250TV provide high sensitivity, repeatability and flexible moisture determination capabilities.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eKey Features\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003e7-inch LCD touch screen\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eAutomatic and manual drift adjustment\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eMultiple titration methods\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eGLP-compliant data management\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eStorage capacity of 200 results\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eUSB data export\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eRS232C communication\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eCSV data output\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eUser password protection\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eSelectable measurement units\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eOven sampling method support\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003e21 CFR software optional\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eTrace moisture measurement\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eConstant moisture determination\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eSuitable for gas, liquid and solid samples\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eKFT200TC for coulometric titration\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eKFT250TV for volumetric titration\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eTechnical Specifications\u003c\/span\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eParameter\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eKFT200TC\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eKFT250TV\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eKarl Fischer Principle\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCoulometric Titration\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVolumetric Titration\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWater Measuring Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10.0 μg to 200 mg\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.1 mg to 250.0 mg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eResolution\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.1 μg\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 μg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRepeatability\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e≤1%\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e≤0.5%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMultiple Titration Methods\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYes\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMeasurement Units\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eμg, mg%, ppm, μg\/mL, mg\/L\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eμg, mg%, ppm, μg\/mL, mg\/L\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDisplay\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7-inch Touch Screen\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7-inch Touch Screen\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003emV Measuring Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 2000 mV\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 2000 mV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003emV Resolution\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.1 mV\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.1 mV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePolarization Current Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 to 200 μA\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 to 200 μA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePolarization Current Accuracy\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e±3%\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e±3%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDrift Adjustment\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAutomatic \/ Manual\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAutomatic \/ Manual\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCommunication Ports\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSB, RS232C\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSB, RS232C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMemory Storage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e200 Results\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e200 Results\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eGMP Compliance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYes\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eUser Password Protection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAvailable\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAvailable\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Supply\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAC 220V, 50–60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAC 220V, 50–60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePacking Dimensions (L×W×H)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e240 × 370 × 270 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e240 × 370 × 270 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Labman","offers":[{"title":"KFT200TC","offer_id":50104723603693,"sku":null,"price":400000.0,"currency_code":"INR","in_stock":true},{"title":"KFT250TV","offer_id":50104723636461,"sku":null,"price":400000.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5672\/6765\/files\/KFT250TV.jpg?v=1781461237"},{"product_id":"karl-fischer-titrator-kft2t-coulometric-method-7-touch-screen-built-in-printer","title":"Karl Fischer Titrator – KFT2T (Coulometric Method | 7\" Touch Screen | Built-in Printer)","description":"\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eKFT2T Karl Fischer Titrator is designed for accurate trace moisture determination using the coulometric Karl Fischer titration principle. The instrument provides high sensitivity for low moisture analysis and is suitable for chemical, pharmaceutical, petrochemical and research laboratories.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eKFT2T features a 7-inch touch screen display with programmable stirring speed and automatic calculation functions. The sealed titration cell minimizes reagent exposure and reduces the influence of environmental humidity, ensuring reliable measurements.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe instrument supports multiple calculation formulas with automatic unit conversion between μg, mg\/L, ppm and percentage. Real-time clock retention during power failure and storage capacity for up to 20,000 results enhance data management and traceability.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eKFT2T incorporates a built-in thermal printer for result documentation and provides rapid moisture determination with automatic stirring and analysis completion in approximately 60 seconds. The system delivers high sensitivity and repeatability for trace moisture analysis across a wide range of applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eKey Features\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003e7-inch touch screen display\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eCoulometric Karl Fischer method\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eHigh sensitivity trace moisture analysis\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eSensitivity down to 0.01 μg H₂O\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eAutomatic stirring\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eFast analysis in approximately 60 seconds\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eSealed titration cell\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eBuilt-in thermal printer\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eAutomatic calculation function\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eMultiple calculation formulas\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eAutomatic unit switching\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eProgrammable stirring speed\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eReal-time clock with power failure retention\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eData storage up to 20,000 results\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eDate and time display\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eTechnical Specifications\u003c\/span\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eParameter\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTitration Method\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCoulometric\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMeasuring Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.0001% (1 ppm) to 100%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSensitivity Threshold\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.01 μg H₂O\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAccuracy\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e±2 μg for 5 μg–1 mg; 0.2% above 1 mg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eResult Output\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBuilt-in Printer\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDisplay Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTouch Screen\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDisplay Size\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7 inch\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMeasurement Units\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eμg, mg\/L, ppm, %\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDate and Time Function\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAmbient Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e15°C to 25°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eData Storage Capacity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20,000 Results\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eHumidity Requirement\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u0026lt;65% RH\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e60 W\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Supply\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAC 220 V, 50–60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMachine Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e280 × 370 × 210 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePacking Dimensions (L×W×H)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e430 × 470 × 330 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNet Weight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eGross Weight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePacking Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eWooden Packing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Labman","offers":[{"title":"Default Title","offer_id":50104724390125,"sku":null,"price":160000.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5672\/6765\/files\/KFT2T.jpg?v=1781461667"}],"url":"https:\/\/www.biotronscientific.com\/collections\/titrators.oembed","provider":"BIOTRON","version":"1.0","type":"link"}