{"title":"Refractometers \u0026 Polarimeters","description":null,"products":[{"product_id":"high-speed-automatic-polarimeter-adp100cfr-dual-wavelength-546-589-nm-0-004-accuracy","title":"High Speed Automatic Polarimeter ADP100CFR (Dual Wavelength 546\/589 nm, ±0.004° Accuracy)","description":"\u003cp data-start=\"314\" data-end=\"673\"\u003eHigh Speed Automatic Polarimeter ADP100CFR is an advanced analytical instrument designed for precise measurement of optical rotation, specific rotation, sugar content, and concentration in optically active substances. Equipped with dual wavelength capability (546 nm and 589 nm), it ensures high accuracy and flexibility across a wide range of applications.\u003c\/p\u003e\n\u003cp data-start=\"675\" data-end=\"1012\"\u003eThe system integrates Peltier-based temperature control for stable and reproducible measurements, making it ideal for pharmaceutical, chemical, and food industries. With built-in software, Windows-based operation, and compliance with GMP, GLP, and 21 CFR Part 11 standards, it supports secure data handling and regulatory requirements.\u003c\/p\u003e\n\u003cp data-start=\"1014\" data-end=\"1198\"\u003eIts high-speed measurement capability, intuitive touchscreen interface, and large internal storage make it suitable for both routine quality control and advanced research laboratories.\u003c\/p\u003e\n\u003ch3 data-start=\"1200\" data-end=\"1217\"\u003eKey Features\u003c\/h3\u003e\n\u003cp data-start=\"1218\" data-end=\"1862\"\u003eDual wavelength operation (546 nm \u0026amp; 589 nm) for versatile analysis\u003cbr data-start=\"1284\" data-end=\"1287\"\u003eHigh accuracy up to ±0.004° with excellent repeatability\u003cbr data-start=\"1343\" data-end=\"1346\"\u003ePeltier temperature control for stable measurement conditions\u003cbr data-start=\"1407\" data-end=\"1410\"\u003eMultiple measurement modes: optical rotation, specific rotation, sugar, concentration\u003cbr data-start=\"1495\" data-end=\"1498\"\u003e21 CFR Part 11 compliance for secure electronic records\u003cbr data-start=\"1553\" data-end=\"1556\"\u003eBuilt-in software with no need for external PC\u003cbr data-start=\"1602\" data-end=\"1605\"\u003e8-inch color touchscreen interface\u003cbr data-start=\"1639\" data-end=\"1642\"\u003eHigh-speed measurement with rapid response time\u003cbr data-start=\"1689\" data-end=\"1692\"\u003eLarge internal storage (16GB) for data management\u003cbr data-start=\"1741\" data-end=\"1744\"\u003eMultipoint automatic calibration for improved precision\u003cbr data-start=\"1799\" data-end=\"1802\"\u003eWide connectivity options including USB, Ethernet, and VGA\u003c\/p\u003e\n\u003ch3 data-start=\"1864\" data-end=\"1893\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"1895\" data-end=\"2639\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"1895\" data-end=\"1924\"\u003e\n\u003ctr data-start=\"1895\" data-end=\"1924\"\u003e\n\u003cth data-start=\"1895\" data-end=\"1907\" data-col-size=\"sm\" class=\"\"\u003eParameter\u003c\/th\u003e\n\u003cth data-start=\"1907\" data-end=\"1924\" data-col-size=\"sm\" class=\"\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"1935\" data-end=\"2639\"\u003e\n\u003ctr data-start=\"1935\" data-end=\"1994\"\u003e\n\u003ctd data-start=\"1935\" data-end=\"1955\" data-col-size=\"sm\"\u003eMeasurement Range\u003c\/td\u003e\n\u003ctd data-start=\"1955\" data-end=\"1994\" data-col-size=\"sm\"\u003e±90° Optical Rotation, ±259°Z Sugar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1995\" data-end=\"2023\"\u003e\n\u003ctd data-start=\"1995\" data-end=\"2013\" data-col-size=\"sm\"\u003eMinimum Reading\u003c\/td\u003e\n\u003ctd data-start=\"2013\" data-end=\"2023\" data-col-size=\"sm\"\u003e0.001°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2024\" data-end=\"2046\"\u003e\n\u003ctd data-start=\"2024\" data-end=\"2035\" data-col-size=\"sm\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd data-start=\"2035\" data-end=\"2046\" data-col-size=\"sm\"\u003e±0.004°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2047\" data-end=\"2074\"\u003e\n\u003ctd data-start=\"2047\" data-end=\"2063\" data-col-size=\"sm\"\u003eRepeatability\u003c\/td\u003e\n\u003ctd data-start=\"2063\" data-end=\"2074\" data-col-size=\"sm\"\u003e±0.002°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2075\" data-end=\"2107\"\u003e\n\u003ctd data-start=\"2075\" data-end=\"2088\" data-col-size=\"sm\"\u003eWavelength\u003c\/td\u003e\n\u003ctd data-start=\"2088\" data-end=\"2107\" data-col-size=\"sm\"\u003e546 nm \u0026amp; 589 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2108\" data-end=\"2148\"\u003e\n\u003ctd data-start=\"2108\" data-end=\"2123\" data-col-size=\"sm\"\u003eLight Source\u003c\/td\u003e\n\u003ctd data-start=\"2123\" data-end=\"2148\" data-col-size=\"sm\"\u003eTungsten Halogen Lamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2149\" data-end=\"2196\"\u003e\n\u003ctd data-start=\"2149\" data-end=\"2169\" data-col-size=\"sm\"\u003eMeasurement Speed\u003c\/td\u003e\n\u003ctd data-start=\"2169\" data-end=\"2196\" data-col-size=\"sm\"\u003e6 measurements \/ 26 sec\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2197\" data-end=\"2224\"\u003e\n\u003ctd data-start=\"2197\" data-end=\"2214\" data-col-size=\"sm\"\u003eResponse Speed\u003c\/td\u003e\n\u003ctd data-start=\"2214\" data-end=\"2224\" data-col-size=\"sm\"\u003e8°\/sec\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2225\" data-end=\"2269\"\u003e\n\u003ctd data-start=\"2225\" data-end=\"2247\" data-col-size=\"sm\"\u003eTemperature Control\u003c\/td\u003e\n\u003ctd data-start=\"2247\" data-end=\"2269\" data-col-size=\"sm\"\u003ePeltier (In-built)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2270\" data-end=\"2305\"\u003e\n\u003ctd data-start=\"2270\" data-end=\"2290\" data-col-size=\"sm\"\u003eTemperature Range\u003c\/td\u003e\n\u003ctd data-start=\"2290\" data-end=\"2305\" data-col-size=\"sm\"\u003e10°C – 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2306\" data-end=\"2339\"\u003e\n\u003ctd data-start=\"2306\" data-end=\"2329\" data-col-size=\"sm\"\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"2329\" data-end=\"2339\" data-col-size=\"sm\"\u003e±0.2°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2340\" data-end=\"2374\"\u003e\n\u003ctd data-start=\"2340\" data-end=\"2350\" data-col-size=\"sm\"\u003eDisplay\u003c\/td\u003e\n\u003ctd data-start=\"2350\" data-end=\"2374\" data-col-size=\"sm\"\u003e8\" Color Touchscreen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2375\" data-end=\"2392\"\u003e\n\u003ctd data-start=\"2375\" data-end=\"2384\" data-col-size=\"sm\"\u003eMemory\u003c\/td\u003e\n\u003ctd data-start=\"2384\" data-end=\"2392\" data-col-size=\"sm\"\u003e16GB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2393\" data-end=\"2416\"\u003e\n\u003ctd data-start=\"2393\" data-end=\"2404\" data-col-size=\"sm\"\u003eSoftware\u003c\/td\u003e\n\u003ctd data-start=\"2404\" data-end=\"2416\" data-col-size=\"sm\"\u003eIn-built\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2417\" data-end=\"2464\"\u003e\n\u003ctd data-start=\"2417\" data-end=\"2430\" data-col-size=\"sm\"\u003eCompliance\u003c\/td\u003e\n\u003ctd data-start=\"2430\" data-end=\"2464\" data-col-size=\"sm\"\u003eGMP \/ GLP \/ FDA 21 CFR Part 11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2465\" data-end=\"2516\"\u003e\n\u003ctd data-start=\"2465\" data-end=\"2477\" data-col-size=\"sm\"\u003eInterface\u003c\/td\u003e\n\u003ctd data-start=\"2477\" data-end=\"2516\" data-col-size=\"sm\"\u003eUSB, Keyboard, Mouse, VGA, Ethernet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2517\" data-end=\"2555\"\u003e\n\u003ctd data-start=\"2517\" data-end=\"2536\" data-col-size=\"sm\"\u003eTest Tube Length\u003c\/td\u003e\n\u003ctd data-start=\"2536\" data-end=\"2555\" data-col-size=\"sm\"\u003e100 mm \u0026amp; 200 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2556\" data-end=\"2584\"\u003e\n\u003ctd data-start=\"2556\" data-end=\"2571\" data-col-size=\"sm\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd data-start=\"2571\" data-end=\"2584\" data-col-size=\"sm\"\u003eAC Supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2585\" data-end=\"2620\"\u003e\n\u003ctd data-start=\"2585\" data-end=\"2598\" data-col-size=\"sm\"\u003eDimensions\u003c\/td\u003e\n\u003ctd data-start=\"2598\" data-end=\"2620\" data-col-size=\"sm\"\u003e865 × 515 × 470 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2621\" data-end=\"2639\"\u003e\n\u003ctd data-start=\"2621\" data-end=\"2630\" data-col-size=\"sm\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-start=\"2630\" data-end=\"2639\" data-col-size=\"sm\"\u003e35 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 data-start=\"2641\" data-end=\"2658\"\u003eApplications\u003c\/h3\u003e\n\u003cp data-start=\"2659\" data-end=\"2846\"\u003ePharmaceutical quality control\u003cbr data-start=\"2689\" data-end=\"2692\"\u003eSugar and food industry analysis\u003cbr data-start=\"2724\" data-end=\"2727\"\u003eChemical and petrochemical analysis\u003cbr data-start=\"2762\" data-end=\"2765\"\u003eResearch laboratories and academia\u003cbr data-start=\"2799\" data-end=\"2802\"\u003eOptical activity and concentration studies\u003c\/p\u003e","brand":"Labman","offers":[{"title":"Default Title","offer_id":49886067654893,"sku":null,"price":551000.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5672\/6765\/files\/ADP100CFR.webp?v=1778791082"},{"product_id":"high-speed-automatic-polarimeter-adp95cfr-single-wavelength-589-nm-0-004-accuracy-peltier-control","title":"High Speed Automatic Polarimeter ADP95CFR (Single Wavelength 589 nm, ±0.004° Accuracy, Peltier Control)","description":"\u003cp data-start=\"320\" data-end=\"695\"\u003eHigh Speed Automatic Polarimeter ADP95CFR is a precision analytical instrument designed for accurate measurement of optical rotation, specific rotation, sugar concentration, and related parameters in optically active substances. Operating at a fixed wavelength of 589 nm, it delivers highly stable and repeatable results across routine and advanced laboratory applications.\u003c\/p\u003e\n\u003cp data-start=\"697\" data-end=\"959\"\u003eThe instrument incorporates an advanced control system with Android-based interface, enabling intuitive operation through a large touchscreen display. Built-in Peltier temperature control ensures consistent sample conditions, enhancing measurement reliability.\u003c\/p\u003e\n\u003cp data-start=\"961\" data-end=\"1193\"\u003eWith compliance to GMP, GLP, and 21 CFR Part 11 standards, along with large internal storage and automated calibration, the system is ideal for regulated environments such as pharmaceutical quality control and research laboratories.\u003c\/p\u003e\n\u003ch3 data-start=\"1195\" data-end=\"1212\"\u003eKey Features\u003c\/h3\u003e\n\u003cp data-start=\"1213\" data-end=\"1815\"\u003eSingle wavelength operation at 589 nm for stable measurements\u003cbr data-start=\"1274\" data-end=\"1277\"\u003eHigh accuracy up to ±0.004° with excellent repeatability\u003cbr data-start=\"1333\" data-end=\"1336\"\u003eAdvanced Peltier temperature control for precise thermal stability\u003cbr data-start=\"1402\" data-end=\"1405\"\u003eAndroid-based operating system with intuitive interface\u003cbr data-start=\"1460\" data-end=\"1463\"\u003e10.1-inch color touchscreen display\u003cbr data-start=\"1498\" data-end=\"1501\"\u003eMultiple measurement modes including optical rotation and sugar analysis\u003cbr data-start=\"1573\" data-end=\"1576\"\u003eMultipoint automatic calibration for enhanced accuracy\u003cbr data-start=\"1630\" data-end=\"1633\"\u003eLarge internal storage up to 128GB\u003cbr data-start=\"1667\" data-end=\"1670\"\u003eFast measurement with high response speed\u003cbr data-start=\"1711\" data-end=\"1714\"\u003e21 CFR Part 11 compliance for secure data management\u003cbr data-start=\"1766\" data-end=\"1769\"\u003eUSB and RS232 connectivity for data transfer\u003c\/p\u003e\n\u003ch3 data-start=\"1817\" data-end=\"1846\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"1848\" data-end=\"2511\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"1848\" data-end=\"1877\"\u003e\n\u003ctr data-start=\"1848\" data-end=\"1877\"\u003e\n\u003cth data-start=\"1848\" data-end=\"1860\" data-col-size=\"sm\" class=\"\"\u003eParameter\u003c\/th\u003e\n\u003cth data-start=\"1860\" data-end=\"1877\" data-col-size=\"sm\" class=\"\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"1888\" data-end=\"2511\"\u003e\n\u003ctr data-start=\"1888\" data-end=\"1947\"\u003e\n\u003ctd data-start=\"1888\" data-end=\"1908\" data-col-size=\"sm\"\u003eMeasurement Range\u003c\/td\u003e\n\u003ctd data-start=\"1908\" data-end=\"1947\" data-col-size=\"sm\"\u003e±90° Optical Rotation, ±259°Z Sugar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1948\" data-end=\"1976\"\u003e\n\u003ctd data-start=\"1948\" data-end=\"1966\" data-col-size=\"sm\"\u003eMinimum Reading\u003c\/td\u003e\n\u003ctd data-start=\"1966\" data-end=\"1976\" data-col-size=\"sm\"\u003e0.001°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1977\" data-end=\"1999\"\u003e\n\u003ctd data-start=\"1977\" data-end=\"1988\" data-col-size=\"sm\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd data-start=\"1988\" data-end=\"1999\" data-col-size=\"sm\"\u003e±0.004°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2000\" data-end=\"2027\"\u003e\n\u003ctd data-start=\"2000\" data-end=\"2016\" data-col-size=\"sm\"\u003eRepeatability\u003c\/td\u003e\n\u003ctd data-start=\"2016\" data-end=\"2027\" data-col-size=\"sm\"\u003e±0.002°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2028\" data-end=\"2051\"\u003e\n\u003ctd data-start=\"2028\" data-end=\"2041\" data-col-size=\"sm\"\u003eWavelength\u003c\/td\u003e\n\u003ctd data-start=\"2041\" data-end=\"2051\" data-col-size=\"sm\"\u003e589 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2052\" data-end=\"2074\"\u003e\n\u003ctd data-start=\"2052\" data-end=\"2067\" data-col-size=\"sm\"\u003eLight Source\u003c\/td\u003e\n\u003ctd data-start=\"2067\" data-end=\"2074\" data-col-size=\"sm\"\u003eLED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2075\" data-end=\"2122\"\u003e\n\u003ctd data-start=\"2075\" data-end=\"2095\" data-col-size=\"sm\"\u003eMeasurement Speed\u003c\/td\u003e\n\u003ctd data-start=\"2095\" data-end=\"2122\" data-col-size=\"sm\"\u003e6 measurements \/ 26 sec\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2123\" data-end=\"2150\"\u003e\n\u003ctd data-start=\"2123\" data-end=\"2140\" data-col-size=\"sm\"\u003eResponse Speed\u003c\/td\u003e\n\u003ctd data-start=\"2140\" data-end=\"2150\" data-col-size=\"sm\"\u003e8°\/sec\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2151\" data-end=\"2195\"\u003e\n\u003ctd data-start=\"2151\" data-end=\"2173\" data-col-size=\"sm\"\u003eTemperature Control\u003c\/td\u003e\n\u003ctd data-start=\"2173\" data-end=\"2195\" data-col-size=\"sm\"\u003ePeltier (In-built)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2196\" data-end=\"2231\"\u003e\n\u003ctd data-start=\"2196\" data-end=\"2216\" data-col-size=\"sm\"\u003eTemperature Range\u003c\/td\u003e\n\u003ctd data-start=\"2216\" data-end=\"2231\" data-col-size=\"sm\"\u003e10°C – 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2232\" data-end=\"2265\"\u003e\n\u003ctd data-start=\"2232\" data-end=\"2255\" data-col-size=\"sm\"\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"2255\" data-end=\"2265\" data-col-size=\"sm\"\u003e±0.2°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2266\" data-end=\"2303\"\u003e\n\u003ctd data-start=\"2266\" data-end=\"2276\" data-col-size=\"sm\"\u003eDisplay\u003c\/td\u003e\n\u003ctd data-start=\"2276\" data-end=\"2303\" data-col-size=\"sm\"\u003e10.1\" Color Touchscreen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2304\" data-end=\"2322\"\u003e\n\u003ctd data-start=\"2304\" data-end=\"2313\" data-col-size=\"sm\"\u003eMemory\u003c\/td\u003e\n\u003ctd data-start=\"2313\" data-end=\"2322\" data-col-size=\"sm\"\u003e128GB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2323\" data-end=\"2346\"\u003e\n\u003ctd data-start=\"2323\" data-end=\"2334\" data-col-size=\"sm\"\u003eSoftware\u003c\/td\u003e\n\u003ctd data-start=\"2334\" data-end=\"2346\" data-col-size=\"sm\"\u003eIn-built\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2347\" data-end=\"2390\"\u003e\n\u003ctd data-start=\"2347\" data-end=\"2360\" data-col-size=\"sm\"\u003eCompliance\u003c\/td\u003e\n\u003ctd data-start=\"2360\" data-end=\"2390\" data-col-size=\"sm\"\u003eGMP \/ GLP \/ 21 CFR Part 11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2391\" data-end=\"2417\"\u003e\n\u003ctd data-start=\"2391\" data-end=\"2403\" data-col-size=\"sm\"\u003eInterface\u003c\/td\u003e\n\u003ctd data-start=\"2403\" data-end=\"2417\" data-col-size=\"sm\"\u003eUSB, RS232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2418\" data-end=\"2456\"\u003e\n\u003ctd data-start=\"2418\" data-end=\"2437\" data-col-size=\"sm\"\u003eTest Tube Length\u003c\/td\u003e\n\u003ctd data-start=\"2437\" data-end=\"2456\" data-col-size=\"sm\"\u003e100 mm \u0026amp; 200 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2457\" data-end=\"2492\"\u003e\n\u003ctd data-start=\"2457\" data-end=\"2470\" data-col-size=\"sm\"\u003eDimensions\u003c\/td\u003e\n\u003ctd data-start=\"2470\" data-end=\"2492\" data-col-size=\"sm\"\u003e870 × 520 × 475 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2493\" data-end=\"2511\"\u003e\n\u003ctd data-start=\"2493\" data-end=\"2502\" data-col-size=\"sm\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-start=\"2502\" data-end=\"2511\" data-col-size=\"sm\"\u003e34 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 data-start=\"2513\" data-end=\"2530\"\u003eApplications\u003c\/h3\u003e\n\u003cp data-start=\"2531\" data-end=\"2738\"\u003ePharmaceutical analysis and quality control\u003cbr data-start=\"2574\" data-end=\"2577\"\u003eSugar and food industry testing\u003cbr data-start=\"2608\" data-end=\"2611\"\u003eChemical and petrochemical laboratories\u003cbr data-start=\"2650\" data-end=\"2653\"\u003eAcademic and research institutions\u003cbr data-start=\"2687\" data-end=\"2690\"\u003eOptical activity and concentration measurement\u003c\/p\u003e","brand":"Labman","offers":[{"title":"Default Title","offer_id":49889628586221,"sku":null,"price":490000.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5672\/6765\/files\/ADP95CFR.webp?v=1778791234"},{"product_id":"automatic-digital-polarimeter-adp-series-45-90-589-nm-touchscreen","title":"Automatic Digital Polarimeter ADP Series (±45° \/ ±90°, 589 nm, Touchscreen)","description":"\u003cp data-start=\"520\" data-end=\"749\"\u003eThe Automatic Digital Polarimeter ADP Series is engineered for precise measurement of optical rotation, specific rotation, sugar concentration, and sample purity across pharmaceutical, chemical, food, and research laboratories.\u003c\/p\u003e\n\u003cp data-start=\"751\" data-end=\"966\"\u003eBased on the optical null detection principle, the system delivers high accuracy, repeatability, and fast measurement performance suitable for both routine quality control and advanced analytical applications.\u003c\/p\u003e\n\u003cp data-start=\"968\" data-end=\"1262\"\u003eThe series includes four models—ADP45, ADP50, ADP75, and ADP90 providing flexibility in measurement range and temperature control. Models ADP50 and ADP90 are equipped with integrated Peltier temperature control, ensuring stable sample conditions for highly sensitive measurements.\u003c\/p\u003e\n\u003cp data-start=\"1264\" data-end=\"1432\"\u003eWith an intuitive touchscreen interface, multi-parameter analysis, and robust data handling, the ADP Series is designed for efficient and reliable laboratory workflows.\u003c\/p\u003e\n\u003ch3 data-start=\"1439\" data-end=\"1458\"\u003eModel Overview\u003c\/h3\u003e\n\u003cp\u003eADP45 – ±45° range, without temperature control\u003c\/p\u003e\n\u003cp\u003eADP50 – ±45° range with integrated Peltier temperature control\u003c\/p\u003e\n\u003cp\u003eADP75 – ±90° range, without temperature control\u003c\/p\u003e\n\u003cp\u003eADP90 – ±90° range with integrated Peltier temperature control\u003c\/p\u003e\n\u003ch3 data-start=\"1719\" data-end=\"1736\"\u003eKey Features\u003c\/h3\u003e\n\u003cp\u003eHigh-resolution touchscreen display (7\" \/ 8\")\u003c\/p\u003e\n\u003cp\u003eAdvanced optical null measurement technology\u003c\/p\u003e\n\u003cp\u003eMultiple measurement modes: optical rotation, specific rotation, sugar, and concentration\u003c\/p\u003e\n\u003cp\u003eAutomatic repeated measurement (up to 6 cycles) with averaging\u003c\/p\u003e\n\u003cp\u003eHigh-speed measurement with excellent repeatability\u003c\/p\u003e\n\u003cp\u003eStable photodiode detection system\u003c\/p\u003e\n\u003cp\u003eInsulated sample chamber for improved temperature stability\u003c\/p\u003e\n\u003cp\u003eSuitable for dark and colored samples\u003c\/p\u003e\n\u003cp\u003eInstant operation with no warm-up time required\u003c\/p\u003e\n\u003cp\u003eUSB and RS232 connectivity for data transfer\u003c\/p\u003e\n\u003cp\u003eOptional Peltier temperature control system (ADP50, ADP90)\u003c\/p\u003e\n\u003ch3 data-start=\"2392\" data-end=\"2421\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"2423\" data-end=\"3146\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"2423\" data-end=\"2468\"\u003e\n\u003ctr data-start=\"2423\" data-end=\"2468\"\u003e\n\u003cth data-start=\"2423\" data-end=\"2435\" data-col-size=\"sm\" class=\"\"\u003eParameter\u003c\/th\u003e\n\u003cth data-start=\"2435\" data-end=\"2451\" data-col-size=\"sm\" class=\"\"\u003eADP45 \/ ADP50\u003c\/th\u003e\n\u003cth data-start=\"2451\" data-end=\"2468\" data-col-size=\"sm\" class=\"\"\u003eADP75 \/ ADP90\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"2512\" data-end=\"3146\"\u003e\n\u003ctr data-start=\"2512\" data-end=\"2547\"\u003e\n\u003ctd data-start=\"2512\" data-end=\"2532\" data-col-size=\"sm\"\u003eMeasurement Range\u003c\/td\u003e\n\u003ctd data-start=\"2532\" data-end=\"2539\" data-col-size=\"sm\"\u003e±45°\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2539\" data-end=\"2547\"\u003e±90°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2548\" data-end=\"2580\"\u003e\n\u003ctd data-start=\"2548\" data-end=\"2561\" data-col-size=\"sm\"\u003eResolution\u003c\/td\u003e\n\u003ctd data-start=\"2561\" data-end=\"2570\" data-col-size=\"sm\"\u003e0.001°\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2570\" data-end=\"2580\"\u003e0.001°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2581\" data-end=\"2612\"\u003e\n\u003ctd data-start=\"2581\" data-end=\"2592\" data-col-size=\"sm\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2592\" data-end=\"2601\"\u003e±0.01°\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2601\" data-end=\"2612\"\u003e±0.004°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2613\" data-end=\"2646\"\u003e\n\u003ctd data-start=\"2613\" data-end=\"2627\" data-col-size=\"sm\"\u003eSugar Range\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2627\" data-end=\"2636\"\u003e±120°Z\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2636\" data-end=\"2646\"\u003e±259°Z\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2647\" data-end=\"2697\"\u003e\n\u003ctd data-start=\"2647\" data-end=\"2669\" data-col-size=\"sm\"\u003eConcentration Range\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2669\" data-end=\"2683\"\u003e0–99.9 g\/ml\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2683\" data-end=\"2697\"\u003e0–100 g\/ml\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2698\" data-end=\"2735\"\u003e\n\u003ctd data-start=\"2698\" data-end=\"2711\" data-col-size=\"sm\"\u003eWavelength\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2711\" data-end=\"2722\"\u003e589.3 nm\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2722\" data-end=\"2735\"\u003e589.44 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2736\" data-end=\"2781\"\u003e\n\u003ctd data-start=\"2736\" data-end=\"2746\" data-col-size=\"sm\"\u003eDisplay\u003c\/td\u003e\n\u003ctd data-start=\"2746\" data-end=\"2763\" data-col-size=\"sm\"\u003e7\" Touchscreen\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2763\" data-end=\"2781\"\u003e8\" Touchscreen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2782\" data-end=\"2843\"\u003e\n\u003ctd data-start=\"2782\" data-end=\"2804\" data-col-size=\"sm\"\u003eTemperature Control\u003c\/td\u003e\n\u003ctd data-start=\"2804\" data-end=\"2823\" data-col-size=\"sm\"\u003eOptional (ADP50)\u003c\/td\u003e\n\u003ctd data-start=\"2823\" data-end=\"2843\" data-col-size=\"sm\"\u003eOptional (ADP90)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2844\" data-end=\"2919\"\u003e\n\u003ctd data-start=\"2844\" data-end=\"2864\" data-col-size=\"sm\"\u003eTemperature Range\u003c\/td\u003e\n\u003ctd data-start=\"2864\" data-end=\"2891\" data-col-size=\"sm\"\u003e10–50°C (Peltier models)\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2891\" data-end=\"2919\"\u003e10–50°C (Peltier models)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2920\" data-end=\"2965\"\u003e\n\u003ctd data-start=\"2920\" data-end=\"2929\" data-col-size=\"sm\"\u003eMemory\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2929\" data-end=\"2939\"\u003eLimited\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2939\" data-end=\"2965\"\u003eUp to 10,000 data sets\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2966\" data-end=\"3005\"\u003e\n\u003ctd data-start=\"2966\" data-end=\"2978\" data-col-size=\"sm\"\u003eInterface\u003c\/td\u003e\n\u003ctd data-start=\"2978\" data-end=\"2991\" data-col-size=\"sm\"\u003eUSB, RS232\u003c\/td\u003e\n\u003ctd data-start=\"2991\" data-end=\"3005\" data-col-size=\"sm\"\u003eUSB, RS232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3006\" data-end=\"3034\"\u003e\n\u003ctd data-start=\"3006\" data-end=\"3021\" data-col-size=\"sm\"\u003eLight Source\u003c\/td\u003e\n\u003ctd data-start=\"3021\" data-end=\"3027\" data-col-size=\"sm\"\u003eLED\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3027\" data-end=\"3034\"\u003eLED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3035\" data-end=\"3091\"\u003e\n\u003ctd data-start=\"3035\" data-end=\"3054\" data-col-size=\"sm\"\u003eTest Tube Length\u003c\/td\u003e\n\u003ctd data-start=\"3054\" data-end=\"3072\" data-col-size=\"sm\"\u003e100 mm \u0026amp; 200 mm\u003c\/td\u003e\n\u003ctd data-start=\"3072\" data-end=\"3091\" data-col-size=\"sm\"\u003e100 mm \u0026amp; 200 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3092\" data-end=\"3146\"\u003e\n\u003ctd data-start=\"3092\" data-end=\"3107\" data-col-size=\"sm\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd data-start=\"3107\" data-end=\"3126\" data-col-size=\"sm\"\u003eAC 220V, 50\/60Hz\u003c\/td\u003e\n\u003ctd data-start=\"3126\" data-end=\"3146\" data-col-size=\"sm\"\u003eAC 220V, 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-start=\"3148\" data-end=\"3151\"\u003e\n\u003ch3 data-start=\"3153\" data-end=\"3170\"\u003eApplications\u003c\/h3\u003e\n\u003cp\u003ePharmaceutical analysis for purity and concentration determination\u003c\/p\u003e\n\u003cp\u003eChemical industry for optical activity measurement\u003c\/p\u003e\n\u003cp\u003eSugar industry for glucose and fructose analysis\u003c\/p\u003e\n\u003cp\u003eFood and beverage industry for quality control\u003c\/p\u003e\n\u003cp\u003eAcademic and research laboratories\u003c\/p\u003e","brand":"Labman","offers":[{"title":"ADP45","offer_id":49894179406061,"sku":null,"price":240000.0,"currency_code":"INR","in_stock":true},{"title":"ADP50","offer_id":49894179438829,"sku":null,"price":325000.0,"currency_code":"INR","in_stock":true},{"title":"ADP75","offer_id":49894179471597,"sku":null,"price":305000.0,"currency_code":"INR","in_stock":true},{"title":"ADP90","offer_id":49894179504365,"sku":null,"price":421000.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5672\/6765\/files\/ADP45.webp?v=1778791322"},{"product_id":"automatic-digital-polarimeter-adp40-45-589-3-nm-touchscreen","title":"Automatic Digital Polarimeter ADP40 (±45°, 589.3 nm, Touchscreen)","description":"\u003cp data-end=\"638\" data-start=\"281\"\u003eThe Automatic Digital Polarimeter ADP40 is a compact and reliable laboratory instrument designed for precise measurement of optical rotation, specific rotation, sugar degree, and concentration. Utilizing a photoelectric automatic measurement principle, the system ensures stable, repeatable, and accurate results for routine analytical applications.\u003c\/p\u003e\n\u003cp data-end=\"934\" data-start=\"640\"\u003eEquipped with a touchscreen color display and user-friendly interface, the ADP40 simplifies operation while enabling efficient data acquisition. The instrument supports multiple measurement modes and performs automatic repeated measurements with averaging, improving result reliability.\u003c\/p\u003e\n\u003cp data-end=\"1079\" data-start=\"936\"\u003eIts robust design and precise optics make it suitable for applications in pharmaceuticals, food, sugar industry, and chemical laboratories.\u003c\/p\u003e\n\u003ch3 data-end=\"1103\" data-start=\"1086\"\u003eKey Features\u003c\/h3\u003e\n\u003cp\u003eMeasurement of optical rotation, specific rotation, sugar degree, and concentration\u003c\/p\u003e\n\u003cp\u003ePhotoelectric automatic measurement principle for high accuracy\u003c\/p\u003e\n\u003cp\u003e4 selectable measurement modes\u003c\/p\u003e\n\u003cp\u003eAutomatic repeat measurement (up to 6 times) with average calculation\u003c\/p\u003e\n\u003cp\u003eTouchscreen color display for easy operation\u003c\/p\u003e\n\u003cp\u003eUSB interface for data transfer\u003c\/p\u003e\n\u003cp\u003eStable LED light source with interference filter\u003c\/p\u003e\n\u003cp\u003eCompact and robust laboratory design\u003c\/p\u003e\n\u003ch3 data-end=\"1583\" data-start=\"1554\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\" data-end=\"2120\" data-start=\"1585\"\u003e\n\u003cthead data-end=\"1606\" data-start=\"1585\"\u003e\n\u003ctr data-end=\"1606\" data-start=\"1585\"\u003e\n\u003cth class=\"\" data-col-size=\"sm\" data-end=\"1597\" data-start=\"1585\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"\" data-col-size=\"md\" data-end=\"1606\" data-start=\"1597\"\u003eADP40\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-end=\"2120\" data-start=\"1627\"\u003e\n\u003ctr data-end=\"1652\" data-start=\"1627\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"1637\" data-start=\"1627\"\u003eDisplay\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"1652\" data-start=\"1637\"\u003eTouchscreen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"1739\" data-start=\"1653\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"1671\" data-start=\"1653\"\u003eMeasuring Modes\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"1739\" data-start=\"1671\"\u003eOptical Rotation, Specific Rotation, Sugar Degree, Concentration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"1787\" data-start=\"1740\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"1755\" data-start=\"1740\"\u003eLight Source\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"1787\" data-start=\"1755\"\u003eLED with Interference Filter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"1813\" data-start=\"1788\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"1801\" data-start=\"1788\"\u003eWavelength\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"1813\" data-start=\"1801\"\u003e589.3 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"1861\" data-start=\"1814\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"1853\" data-start=\"1814\"\u003eMeasurement Range (Optical Rotation)\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"1861\" data-start=\"1853\"\u003e±45°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"1886\" data-start=\"1862\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"1876\" data-start=\"1862\"\u003eSugar Range\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"1886\" data-start=\"1876\"\u003e±120°Z\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"1915\" data-start=\"1887\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"1905\" data-start=\"1887\"\u003eMinimum Reading\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"1915\" data-start=\"1905\"\u003e0.001°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"1944\" data-start=\"1916\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"1932\" data-start=\"1916\"\u003eRepeatability\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"1944\" data-start=\"1932\"\u003e≤ 0.003°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"1983\" data-start=\"1945\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"1964\" data-start=\"1945\"\u003eTest Tube Length\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"1983\" data-start=\"1964\"\u003e100 mm \u0026amp; 200 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2014\" data-start=\"1984\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2007\" data-start=\"1984\"\u003eMinimum Transmission\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"2014\" data-start=\"2007\"\u003e10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2034\" data-start=\"2015\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2027\" data-start=\"2015\"\u003eInterface\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"2034\" data-start=\"2027\"\u003eUSB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2068\" data-start=\"2035\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2050\" data-start=\"2035\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"2068\" data-start=\"2050\"\u003eAC 220V \/ 50Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2120\" data-start=\"2069\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2091\" data-start=\"2069\"\u003eDimensions \u0026amp; Weight\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"2120\" data-start=\"2091\"\u003e730 × 480 × 500 mm, 32 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Labman","offers":[{"title":"Default Title","offer_id":49894328893677,"sku":null,"price":200000.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5672\/6765\/files\/ADP40.webp?v=1778791457"},{"product_id":"manual-lab-polarimeter-lmpm180-180-589-4-nm-led","title":"Manual Lab Polarimeter LMPM180 (±180°, 589.4 nm, LED)","description":"\u003cp data-start=\"224\" data-end=\"877\"\u003eThe Manual Lab Polarimeter LMPM180 is designed for measuring the optical rotation of optically active substances in laboratory applications. It uses a disc-based optical system where polarized light is split into ordinary and extraordinary rays, enabling clear observation through the eyepiece. The user adjusts the instrument to the zero point and records the dial reading to determine optical rotation values. This method allows reliable evaluation of purity, concentration, content, and specific rotation. The instrument is simple to operate, durable, and well suited for routine analysis in chemical, pharmaceutical, food, and academic laboratories.\u003c\/p\u003e\n\u003ch3 data-start=\"879\" data-end=\"896\"\u003eKey Features\u003c\/h3\u003e\n\u003cp data-start=\"897\" data-end=\"1277\"\u003eManual polarimeter with wide measurement range up to ±180°\u003cbr data-start=\"955\" data-end=\"958\"\u003eSuitable for determining optical rotation of compounds\u003cbr data-start=\"1012\" data-end=\"1015\"\u003eMeasurement accuracy up to ±0.05°\u003cbr data-start=\"1048\" data-end=\"1051\"\u003eDisc polarimeter design with LED light source\u003cbr data-start=\"1096\" data-end=\"1099\"\u003eEyepiece-based observation with precise manual adjustment\u003cbr data-start=\"1156\" data-end=\"1159\"\u003eSupports analysis of purity, concentration, content and specific rotation\u003cbr data-start=\"1232\" data-end=\"1235\"\u003eStable performance with simple operation\u003c\/p\u003e\n\u003ch3 data-start=\"1279\" data-end=\"1308\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"1310\" data-end=\"1740\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"1310\" data-end=\"1333\"\u003e\n\u003ctr data-start=\"1310\" data-end=\"1333\"\u003e\n\u003cth data-start=\"1310\" data-end=\"1322\" data-col-size=\"sm\" class=\"\"\u003eParameter\u003c\/th\u003e\n\u003cth data-start=\"1322\" data-end=\"1333\" data-col-size=\"sm\" class=\"\"\u003eLMPM180\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"1356\" data-end=\"1740\"\u003e\n\u003ctr data-start=\"1356\" data-end=\"1404\"\u003e\n\u003ctd data-start=\"1356\" data-end=\"1376\" data-col-size=\"sm\"\u003eMeasurement Range\u003c\/td\u003e\n\u003ctd data-start=\"1376\" data-end=\"1404\" data-col-size=\"sm\"\u003e±180° (Optical Rotation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1405\" data-end=\"1424\"\u003e\n\u003ctd data-start=\"1405\" data-end=\"1418\" data-col-size=\"sm\"\u003eDial Value\u003c\/td\u003e\n\u003ctd data-start=\"1418\" data-end=\"1424\" data-col-size=\"sm\"\u003e1°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1425\" data-end=\"1456\"\u003e\n\u003ctd data-start=\"1425\" data-end=\"1446\" data-col-size=\"sm\"\u003eMeasuring Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"1446\" data-end=\"1456\" data-col-size=\"sm\"\u003e±0.05°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1457\" data-end=\"1489\"\u003e\n\u003ctd data-start=\"1457\" data-end=\"1483\" data-col-size=\"sm\"\u003eMagnifier Magnification\u003c\/td\u003e\n\u003ctd data-start=\"1483\" data-end=\"1489\" data-col-size=\"sm\"\u003e3X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1490\" data-end=\"1512\"\u003e\n\u003ctd data-start=\"1490\" data-end=\"1505\" data-col-size=\"sm\"\u003eLight Source\u003c\/td\u003e\n\u003ctd data-start=\"1505\" data-end=\"1512\" data-col-size=\"sm\"\u003eLED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1513\" data-end=\"1538\"\u003e\n\u003ctd data-start=\"1513\" data-end=\"1526\" data-col-size=\"sm\"\u003eWavelength\u003c\/td\u003e\n\u003ctd data-start=\"1526\" data-end=\"1538\" data-col-size=\"sm\"\u003e589.4 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1539\" data-end=\"1576\"\u003e\n\u003ctd data-start=\"1539\" data-end=\"1560\" data-col-size=\"sm\"\u003eSample Tube Length\u003c\/td\u003e\n\u003ctd data-start=\"1560\" data-end=\"1576\" data-col-size=\"sm\"\u003eUp to 200 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1577\" data-end=\"1630\"\u003e\n\u003ctd data-start=\"1577\" data-end=\"1593\" data-col-size=\"sm\"\u003eStandard Tube\u003c\/td\u003e\n\u003ctd data-start=\"1593\" data-end=\"1630\" data-col-size=\"sm\"\u003e100 mm \u0026amp; 200 mm Glass Sample Tube\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1631\" data-end=\"1664\"\u003e\n\u003ctd data-start=\"1631\" data-end=\"1646\" data-col-size=\"sm\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd data-start=\"1646\" data-end=\"1664\" data-col-size=\"sm\"\u003eAC 220V \/ 50Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1665\" data-end=\"1716\"\u003e\n\u003ctd data-start=\"1665\" data-end=\"1694\" data-col-size=\"sm\"\u003ePacking Dimensions (L×W×H)\u003c\/td\u003e\n\u003ctd data-start=\"1694\" data-end=\"1716\" data-col-size=\"sm\"\u003e570 × 200 × 400 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1717\" data-end=\"1740\"\u003e\n\u003ctd data-start=\"1717\" data-end=\"1732\" data-col-size=\"sm\"\u003eGross Weight\u003c\/td\u003e\n\u003ctd data-start=\"1732\" data-end=\"1740\" data-col-size=\"sm\"\u003e4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 data-start=\"1742\" data-end=\"1759\"\u003eApplications\u003c\/h3\u003e\n\u003cp data-start=\"1760\" data-end=\"1968\"\u003eChemical laboratories for optical rotation measurement\u003cbr data-start=\"1814\" data-end=\"1817\"\u003ePharmaceutical analysis for purity and concentration determination\u003cbr data-start=\"1883\" data-end=\"1886\"\u003eFood and sugar industry for quality control\u003cbr data-start=\"1929\" data-end=\"1932\"\u003eAcademic and research laboratories\u003c\/p\u003e","brand":"Labman","offers":[{"title":"Default Title","offer_id":49926283690221,"sku":null,"price":40000.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5672\/6765\/files\/LMPM180.webp?v=1778791593"},{"product_id":"manual-abbe-refractometer-mar100-1-300-1-700-nd-0-95-brix-digital-temperature","title":"Manual ABBE Refractometer MAR100 (1.300–1.700 nD, 0–95% Brix, Digital Temperature)","description":"\u003cp data-start=\"287\" data-end=\"1077\"\u003eThe Manual ABBE Refractometer MAR100 is designed for precise measurement of refractive index and sugar concentration in transparent and translucent samples. It is suitable for both liquid and solid sample analysis, providing reliable results for quality control and research applications. The instrument features a robust cast metal housing and binocular observation system for clear and accurate readings. It supports measurement in both refractive index and Brix units, making it versatile for various laboratory and industrial uses. Equipped with a digital thermometer, the system ensures accurate temperature monitoring, which is critical for refractive index measurements. The MAR100 is widely used in food and beverage analysis, sugar industry applications, and research laboratories.\u003c\/p\u003e\n\u003ch3 data-start=\"1079\" data-end=\"1096\"\u003eKey Features\u003c\/h3\u003e\n\u003cp data-start=\"1097\" data-end=\"1443\"\u003eSolid cast metal housing for durability\u003cbr data-start=\"1136\" data-end=\"1139\"\u003eMeasurement of refractive index and sugar content\u003cbr data-start=\"1188\" data-end=\"1191\"\u003eSuitable for transparent and translucent samples\u003cbr data-start=\"1239\" data-end=\"1242\"\u003eDual measurement units Brix and refractive index\u003cbr data-start=\"1290\" data-end=\"1293\"\u003eEasy handling with binocular observation system\u003cbr data-start=\"1340\" data-end=\"1343\"\u003eEquipped with digital temperature display\u003cbr data-start=\"1384\" data-end=\"1387\"\u003eWide application in laboratory and industrial analysis\u003c\/p\u003e\n\u003ch3 data-start=\"1445\" data-end=\"1474\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"1476\" data-end=\"1997\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"1476\" data-end=\"1498\"\u003e\n\u003ctr data-start=\"1476\" data-end=\"1498\"\u003e\n\u003cth data-start=\"1476\" data-end=\"1488\" data-col-size=\"sm\" class=\"\"\u003eParameter\u003c\/th\u003e\n\u003cth data-start=\"1488\" data-end=\"1498\" data-col-size=\"sm\" class=\"\"\u003eMAR100\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"1521\" data-end=\"1997\"\u003e\n\u003ctr data-start=\"1521\" data-end=\"1566\"\u003e\n\u003ctd data-start=\"1521\" data-end=\"1546\" data-col-size=\"sm\"\u003eRefractive Index Range\u003c\/td\u003e\n\u003ctd data-start=\"1546\" data-end=\"1566\" data-col-size=\"sm\"\u003e1.300 – 1.700 nD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1567\" data-end=\"1609\"\u003e\n\u003ctd data-start=\"1567\" data-end=\"1595\" data-col-size=\"sm\"\u003eRefractive Index Accuracy\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1595\" data-end=\"1609\"\u003e±0.0003 nD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1610\" data-end=\"1642\"\u003e\n\u003ctd data-start=\"1610\" data-end=\"1629\" data-col-size=\"sm\"\u003eMinimum Division\u003c\/td\u003e\n\u003ctd data-start=\"1629\" data-end=\"1642\" data-col-size=\"sm\"\u003e0.0005 nD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1643\" data-end=\"1672\"\u003e\n\u003ctd data-start=\"1643\" data-end=\"1656\" data-col-size=\"sm\"\u003eBrix Range\u003c\/td\u003e\n\u003ctd data-start=\"1656\" data-end=\"1672\" data-col-size=\"sm\"\u003e0 – 95% Brix\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1673\" data-end=\"1713\"\u003e\n\u003ctd data-start=\"1673\" data-end=\"1704\" data-col-size=\"sm\"\u003eSugar Concentration Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"1704\" data-end=\"1713\" data-col-size=\"sm\"\u003e0.25%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1714\" data-end=\"1748\"\u003e\n\u003ctd data-start=\"1714\" data-end=\"1735\" data-col-size=\"sm\"\u003eObservation Method\u003c\/td\u003e\n\u003ctd data-start=\"1735\" data-end=\"1748\" data-col-size=\"sm\"\u003eBinocular\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1749\" data-end=\"1791\"\u003e\n\u003ctd data-start=\"1749\" data-end=\"1777\" data-col-size=\"sm\"\u003eTemperature Range Display\u003c\/td\u003e\n\u003ctd data-start=\"1777\" data-end=\"1791\" data-col-size=\"sm\"\u003eRT to 70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1792\" data-end=\"1822\"\u003e\n\u003ctd data-start=\"1792\" data-end=\"1815\" data-col-size=\"sm\"\u003eTemperature Division\u003c\/td\u003e\n\u003ctd data-start=\"1815\" data-end=\"1822\" data-col-size=\"sm\"\u003e1°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1823\" data-end=\"1856\"\u003e\n\u003ctd data-start=\"1823\" data-end=\"1845\" data-col-size=\"sm\"\u003eTemperature Display\u003c\/td\u003e\n\u003ctd data-start=\"1845\" data-end=\"1856\" data-col-size=\"sm\"\u003eDigital\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1857\" data-end=\"1898\"\u003e\n\u003ctd data-start=\"1857\" data-end=\"1872\" data-col-size=\"sm\"\u003eLight Source\u003c\/td\u003e\n\u003ctd data-start=\"1872\" data-end=\"1898\" data-col-size=\"sm\"\u003eNatural\/External Light\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1899\" data-end=\"1935\"\u003e\n\u003ctd data-start=\"1899\" data-end=\"1914\" data-col-size=\"sm\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd data-start=\"1914\" data-end=\"1935\" data-col-size=\"sm\"\u003eAC 220V \/ 50–60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1936\" data-end=\"1979\"\u003e\n\u003ctd data-start=\"1936\" data-end=\"1957\" data-col-size=\"sm\"\u003eDimensions (L×W×H)\u003c\/td\u003e\n\u003ctd data-start=\"1957\" data-end=\"1979\" data-col-size=\"sm\"\u003e280 × 180 × 385 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1980\" data-end=\"1997\"\u003e\n\u003ctd data-start=\"1980\" data-end=\"1989\" data-col-size=\"sm\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-start=\"1989\" data-end=\"1997\" data-col-size=\"sm\"\u003e3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 data-start=\"1999\" data-end=\"2016\"\u003eApplications\u003c\/h3\u003e\n\u003cp data-start=\"2017\" data-end=\"2234\"\u003eFood and beverage industry for sugar concentration measurement\u003cbr data-start=\"2079\" data-end=\"2082\"\u003eQuality control in jams, syrups, and confectionery products\u003cbr data-start=\"2141\" data-end=\"2144\"\u003eChemical laboratories for refractive index analysis\u003cbr data-start=\"2195\" data-end=\"2198\"\u003eResearch and academic laboratories\u003c\/p\u003e","brand":"Labman","offers":[{"title":"Default Title","offer_id":49926285590765,"sku":null,"price":37500.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5672\/6765\/files\/MAR100.webp?v=1778791647"},{"product_id":"automatic-digital-refractometer-rfm950-rfm970-1-3000-1-7000-nd-0-100-brix-touchscreen","title":"Automatic Digital Refractometer RFM950 \/ RFM970 (1.3000–1.7000 nD, 0–100% Brix, Touchscreen)","description":"\u003cp data-start=\"293\" data-end=\"998\"\u003eThe Automatic Digital Refractometer RFM950 and RFM970 are designed for precise measurement of refractive index and Brix in liquid samples. These instruments are suitable for applications across petroleum, chemical, pharmaceutical, sugar, and food industries as well as research laboratories. The system provides fast and accurate analysis of transparent and translucent samples while automatically compensating for temperature effects on Brix values. It features a user-friendly touchscreen interface and high-resolution optical system for reliable and repeatable measurements. The RFM970 model includes thermostatic temperature control, enabling improved measurement stability for sensitive applications.\u003c\/p\u003e\n\u003ch3 data-start=\"1000\" data-end=\"1017\"\u003eKey Features\u003c\/h3\u003e\n\u003cp data-start=\"1018\" data-end=\"1429\"\u003eFully automatic measurement system\u003cbr data-start=\"1052\" data-end=\"1055\"\u003eTouchscreen display for easy operation\u003cbr data-start=\"1093\" data-end=\"1096\"\u003eMeasurement of refractive index and Brix\u003cbr data-start=\"1136\" data-end=\"1139\"\u003eAutomatic temperature compensation for Brix\u003cbr data-start=\"1182\" data-end=\"1185\"\u003eFast measurement time of approximately 2 seconds\u003cbr data-start=\"1233\" data-end=\"1236\"\u003eCalibration password protection\u003cbr data-start=\"1267\" data-end=\"1270\"\u003eMemory storage up to 1024 results\u003cbr data-start=\"1303\" data-end=\"1306\"\u003eEasy cleaning prism design\u003cbr data-start=\"1332\" data-end=\"1335\"\u003eUser configurable scan and measurement settings\u003cbr data-start=\"1382\" data-end=\"1385\"\u003eThermostatic temperature control in RFM970\u003c\/p\u003e\n\u003ch3 data-start=\"1431\" data-end=\"1460\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"1462\" data-end=\"2237\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"1462\" data-end=\"1493\"\u003e\n\u003ctr data-start=\"1462\" data-end=\"1493\"\u003e\n\u003cth data-start=\"1462\" data-end=\"1474\" data-col-size=\"sm\" class=\"\"\u003eParameter\u003c\/th\u003e\n\u003cth data-start=\"1474\" data-end=\"1483\" data-col-size=\"sm\" class=\"\"\u003eRFM950\u003c\/th\u003e\n\u003cth data-start=\"1483\" data-end=\"1493\" data-col-size=\"sm\" class=\"\"\u003eRFM970\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"1525\" data-end=\"2237\"\u003e\n\u003ctr data-start=\"1525\" data-end=\"1564\"\u003e\n\u003ctd data-start=\"1525\" data-end=\"1535\" data-col-size=\"sm\"\u003eDisplay\u003c\/td\u003e\n\u003ctd data-start=\"1535\" data-end=\"1549\" data-col-size=\"sm\"\u003eTouchscreen\u003c\/td\u003e\n\u003ctd data-start=\"1549\" data-end=\"1564\" data-col-size=\"sm\"\u003eTouchscreen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1565\" data-end=\"1633\"\u003e\n\u003ctd data-start=\"1565\" data-end=\"1590\" data-col-size=\"sm\"\u003eRefractive Index Range\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1590\" data-end=\"1611\"\u003e1.3000 – 1.7000 nD\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1611\" data-end=\"1633\"\u003e1.3000 – 1.7000 nD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1634\" data-end=\"1670\"\u003e\n\u003ctd data-start=\"1634\" data-end=\"1647\" data-col-size=\"sm\"\u003eBrix Range\u003c\/td\u003e\n\u003ctd data-start=\"1647\" data-end=\"1658\" data-col-size=\"sm\"\u003e0 – 100%\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1658\" data-end=\"1670\"\u003e0 – 100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1671\" data-end=\"1720\"\u003e\n\u003ctd data-start=\"1671\" data-end=\"1699\" data-col-size=\"sm\"\u003eRefractive Index Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"1699\" data-end=\"1709\" data-col-size=\"sm\"\u003e±0.0002\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1709\" data-end=\"1720\"\u003e±0.0002\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1721\" data-end=\"1754\"\u003e\n\u003ctd data-start=\"1721\" data-end=\"1737\" data-col-size=\"sm\"\u003eBrix Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"1737\" data-end=\"1745\" data-col-size=\"sm\"\u003e±0.1%\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1745\" data-end=\"1754\"\u003e±0.1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1755\" data-end=\"1806\"\u003e\n\u003ctd data-start=\"1755\" data-end=\"1785\" data-col-size=\"sm\"\u003eRefractive Index Resolution\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1785\" data-end=\"1795\"\u003e0.00001\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1795\" data-end=\"1806\"\u003e0.00001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1807\" data-end=\"1842\"\u003e\n\u003ctd data-start=\"1807\" data-end=\"1825\" data-col-size=\"sm\"\u003eBrix Resolution\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1825\" data-end=\"1833\"\u003e0.01%\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1833\" data-end=\"1842\"\u003e0.01%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1843\" data-end=\"1896\"\u003e\n\u003ctd data-start=\"1843\" data-end=\"1871\" data-col-size=\"sm\"\u003eTemperature Display Range\u003c\/td\u003e\n\u003ctd data-start=\"1871\" data-end=\"1883\" data-col-size=\"sm\"\u003e0 to 50°C\u003c\/td\u003e\n\u003ctd data-start=\"1883\" data-end=\"1896\" data-col-size=\"sm\"\u003e0 to 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1897\" data-end=\"1950\"\u003e\n\u003ctd data-start=\"1897\" data-end=\"1919\" data-col-size=\"sm\"\u003eTemperature Control\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1919\" data-end=\"1924\"\u003eNA\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1924\" data-end=\"1950\"\u003eRoom temperature ±10°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1951\" data-end=\"1993\"\u003e\n\u003ctd data-start=\"1951\" data-end=\"1974\" data-col-size=\"sm\"\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1974\" data-end=\"1983\"\u003e±0.5°C\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1983\" data-end=\"1993\"\u003e±0.5°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1994\" data-end=\"2050\"\u003e\n\u003ctd data-start=\"1994\" data-end=\"2015\" data-col-size=\"sm\"\u003eMemory \u0026amp; Interface\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2015\" data-end=\"2032\"\u003e1024 data, USB\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2032\" data-end=\"2050\"\u003e1024 data, USB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2051\" data-end=\"2090\"\u003e\n\u003ctd data-start=\"2051\" data-end=\"2063\" data-col-size=\"sm\"\u003eInterface\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2063\" data-end=\"2076\"\u003eUSB, RS232\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2076\" data-end=\"2090\"\u003eUSB, RS232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2091\" data-end=\"2147\"\u003e\n\u003ctd data-start=\"2091\" data-end=\"2106\" data-col-size=\"sm\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2106\" data-end=\"2126\"\u003eAC 220V \/ 50–60Hz\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2126\" data-end=\"2147\"\u003eAC 220V \/ 50–60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2148\" data-end=\"2212\"\u003e\n\u003ctd data-start=\"2148\" data-end=\"2169\" data-col-size=\"sm\"\u003eDimensions (L×W×H)\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2169\" data-end=\"2190\"\u003e500 × 340 × 240 mm\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2190\" data-end=\"2212\"\u003e500 × 340 × 240 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2213\" data-end=\"2237\"\u003e\n\u003ctd data-start=\"2213\" data-end=\"2222\" data-col-size=\"sm\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2222\" data-end=\"2229\"\u003e8 kg\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2229\" data-end=\"2237\"\u003e9 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 data-start=\"2239\" data-end=\"2256\"\u003eApplications\u003c\/h3\u003e\n\u003cp data-start=\"2257\" data-end=\"2462\"\u003ePetroleum and chemical industry for refractive index analysis\u003cbr data-start=\"2318\" data-end=\"2321\"\u003ePharmaceutical industry for concentration measurement\u003cbr data-start=\"2374\" data-end=\"2377\"\u003eSugar and food industry for Brix determination\u003cbr data-start=\"2423\" data-end=\"2426\"\u003eAcademic and research laboratories\u003c\/p\u003e","brand":"Labman","offers":[{"title":"RFM950","offer_id":49926289850605,"sku":null,"price":250000.0,"currency_code":"INR","in_stock":true},{"title":"RFM970","offer_id":49926289883373,"sku":null,"price":395000.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5672\/6765\/files\/RFM950.webp?v=1778791735"},{"product_id":"automatic-digital-refractometer-rfm100cfr-1-30000-1-70000-nd-0-100-brix-peltier-control","title":"Automatic Digital Refractometer RFM100CFR (1.30000–1.70000 nD, 0–100% Brix, Peltier Control)","description":"\u003cp data-start=\"332\" data-end=\"1300\"\u003eThe Automatic Digital Refractometer RFM100CFR is designed for high-accuracy measurement of refractive index and Brix in laboratory and industrial applications. It operates using a high-resolution CCD detection system combined with a precision optical setup to deliver stable and repeatable results. The instrument is equipped with an integrated Peltier temperature control system, ensuring precise thermal stability during measurement, which is critical for refractive index analysis. It features an intuitive touchscreen interface with inbuilt software, eliminating the need for an external computer. The system supports multiple measurement modes and offers secure data handling with electronic signatures and user management. Built with a durable sapphire prism, the instrument ensures long-term reliability and easy maintenance. It is suitable for pharmaceutical, chemical, food, sugar, and research laboratory applications requiring compliance and high precision.\u003c\/p\u003e\n\u003ch3 data-start=\"1302\" data-end=\"1319\"\u003eKey Features\u003c\/h3\u003e\n\u003cp data-start=\"1320\" data-end=\"1777\"\u003eFully automatic measurement system\u003cbr data-start=\"1354\" data-end=\"1357\"\u003eHigh-resolution CCD detection system\u003cbr data-start=\"1393\" data-end=\"1396\"\u003eTouchscreen colour display for easy operation\u003cbr data-start=\"1441\" data-end=\"1444\"\u003eMultiple measurement modes for versatile analysis\u003cbr data-start=\"1493\" data-end=\"1496\"\u003eInbuilt software with no requirement for external PC\u003cbr data-start=\"1548\" data-end=\"1551\"\u003eIntegrated Peltier temperature control system\u003cbr data-start=\"1596\" data-end=\"1599\"\u003eHigh precision sapphire prism for durability\u003cbr data-start=\"1643\" data-end=\"1646\"\u003eFast measurement with minimal sample requirement\u003cbr data-start=\"1694\" data-end=\"1697\"\u003eElectronic signature and password management\u003cbr data-start=\"1741\" data-end=\"1744\"\u003eLarge internal storage capacity\u003c\/p\u003e\n\u003ch3 data-start=\"1779\" data-end=\"1808\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"1810\" data-end=\"2645\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"1810\" data-end=\"1835\"\u003e\n\u003ctr data-start=\"1810\" data-end=\"1835\"\u003e\n\u003cth data-start=\"1810\" data-end=\"1822\" data-col-size=\"sm\" class=\"\"\u003eParameter\u003c\/th\u003e\n\u003cth data-start=\"1822\" data-end=\"1835\" data-col-size=\"md\" class=\"\"\u003eRFM100CFR\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"1861\" data-end=\"2645\"\u003e\n\u003ctr data-start=\"1861\" data-end=\"1891\"\u003e\n\u003ctd data-start=\"1861\" data-end=\"1880\" data-col-size=\"sm\"\u003eOperating System\u003c\/td\u003e\n\u003ctd data-start=\"1880\" data-end=\"1891\" data-col-size=\"md\"\u003eWindows\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1892\" data-end=\"1914\"\u003e\n\u003ctd data-start=\"1892\" data-end=\"1903\" data-col-size=\"sm\"\u003eSoftware\u003c\/td\u003e\n\u003ctd data-start=\"1903\" data-end=\"1914\" data-col-size=\"md\"\u003eInbuilt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1915\" data-end=\"1964\"\u003e\n\u003ctd data-start=\"1915\" data-end=\"1940\" data-col-size=\"sm\"\u003eRefractive Index Range\u003c\/td\u003e\n\u003ctd data-start=\"1940\" data-end=\"1964\" data-col-size=\"md\"\u003e1.30000 – 1.70000 nD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1965\" data-end=\"2004\"\u003e\n\u003ctd data-start=\"1965\" data-end=\"1993\" data-col-size=\"sm\"\u003eRefractive Index Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"1993\" data-end=\"2004\" data-col-size=\"md\"\u003e±0.0001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2005\" data-end=\"2046\"\u003e\n\u003ctd data-start=\"2005\" data-end=\"2035\" data-col-size=\"sm\"\u003eRefractive Index Resolution\u003c\/td\u003e\n\u003ctd data-start=\"2035\" data-end=\"2046\" data-col-size=\"md\"\u003e0.00001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2047\" data-end=\"2072\"\u003e\n\u003ctd data-start=\"2047\" data-end=\"2060\" data-col-size=\"sm\"\u003eBrix Range\u003c\/td\u003e\n\u003ctd data-start=\"2060\" data-end=\"2072\" data-col-size=\"md\"\u003e0 – 100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2073\" data-end=\"2098\"\u003e\n\u003ctd data-start=\"2073\" data-end=\"2089\" data-col-size=\"sm\"\u003eBrix Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"2089\" data-end=\"2098\" data-col-size=\"md\"\u003e±0.1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2099\" data-end=\"2126\"\u003e\n\u003ctd data-start=\"2099\" data-end=\"2117\" data-col-size=\"sm\"\u003eBrix Resolution\u003c\/td\u003e\n\u003ctd data-start=\"2117\" data-end=\"2126\" data-col-size=\"md\"\u003e0.01%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2127\" data-end=\"2170\"\u003e\n\u003ctd data-start=\"2127\" data-end=\"2149\" data-col-size=\"sm\"\u003eTemperature Control\u003c\/td\u003e\n\u003ctd data-start=\"2149\" data-end=\"2170\" data-col-size=\"md\"\u003ePeltier (Inbuilt)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2171\" data-end=\"2214\"\u003e\n\u003ctd data-start=\"2171\" data-end=\"2199\" data-col-size=\"sm\"\u003eTemperature Display Range\u003c\/td\u003e\n\u003ctd data-start=\"2199\" data-end=\"2214\" data-col-size=\"md\"\u003e0°C – 100°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2215\" data-end=\"2257\"\u003e\n\u003ctd data-start=\"2215\" data-end=\"2243\" data-col-size=\"sm\"\u003eTemperature Control Range\u003c\/td\u003e\n\u003ctd data-start=\"2243\" data-end=\"2257\" data-col-size=\"md\"\u003e5°C – 85°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2258\" data-end=\"2293\"\u003e\n\u003ctd data-start=\"2258\" data-end=\"2283\" data-col-size=\"sm\"\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd data-start=\"2283\" data-end=\"2293\" data-col-size=\"md\"\u003e0.01°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2294\" data-end=\"2328\"\u003e\n\u003ctd data-start=\"2294\" data-end=\"2317\" data-col-size=\"sm\"\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"2317\" data-end=\"2328\" data-col-size=\"md\"\u003e±0.02°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2329\" data-end=\"2364\"\u003e\n\u003ctd data-start=\"2329\" data-end=\"2339\" data-col-size=\"sm\"\u003eDisplay\u003c\/td\u003e\n\u003ctd data-start=\"2339\" data-end=\"2364\" data-col-size=\"md\"\u003e8\" Colour Touchscreen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2365\" data-end=\"2383\"\u003e\n\u003ctd data-start=\"2365\" data-end=\"2374\" data-col-size=\"sm\"\u003eMemory\u003c\/td\u003e\n\u003ctd data-start=\"2374\" data-end=\"2383\" data-col-size=\"md\"\u003e16 GB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2384\" data-end=\"2404\"\u003e\n\u003ctd data-start=\"2384\" data-end=\"2392\" data-col-size=\"sm\"\u003ePrism\u003c\/td\u003e\n\u003ctd data-start=\"2392\" data-end=\"2404\" data-col-size=\"md\"\u003eSapphire\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2405\" data-end=\"2437\"\u003e\n\u003ctd data-start=\"2405\" data-end=\"2425\" data-col-size=\"sm\"\u003eMeasurement Modes\u003c\/td\u003e\n\u003ctd data-start=\"2425\" data-end=\"2437\" data-col-size=\"md\"\u003e12 Types\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2438\" data-end=\"2499\"\u003e\n\u003ctd data-start=\"2438\" data-end=\"2450\" data-col-size=\"sm\"\u003eInterface\u003c\/td\u003e\n\u003ctd data-start=\"2450\" data-end=\"2499\" data-col-size=\"md\"\u003eUSB, Keyboard, Mouse, Ethernet, Optional WLAN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2500\" data-end=\"2547\"\u003e\n\u003ctd data-start=\"2500\" data-end=\"2513\" data-col-size=\"sm\"\u003eCompliance\u003c\/td\u003e\n\u003ctd data-start=\"2513\" data-end=\"2547\" data-col-size=\"md\"\u003eGMP \/ GLP \/ FDA 21 CFR Part 11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2548\" data-end=\"2583\"\u003e\n\u003ctd data-start=\"2548\" data-end=\"2563\" data-col-size=\"sm\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd data-start=\"2563\" data-end=\"2583\" data-col-size=\"md\"\u003eAC 220V, 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2584\" data-end=\"2627\"\u003e\n\u003ctd data-start=\"2584\" data-end=\"2605\" data-col-size=\"sm\"\u003eDimensions (L×W×H)\u003c\/td\u003e\n\u003ctd data-start=\"2605\" data-end=\"2627\" data-col-size=\"md\"\u003e570 × 470 × 300 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2628\" data-end=\"2645\"\u003e\n\u003ctd data-start=\"2628\" data-end=\"2637\" data-col-size=\"sm\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-start=\"2637\" data-end=\"2645\" data-col-size=\"md\"\u003e9 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 data-start=\"2647\" data-end=\"2664\"\u003eApplications\u003c\/h3\u003e\n\u003cp data-start=\"2665\" data-end=\"2930\"\u003ePharmaceutical industry for quality control and formulation analysis\u003cbr data-start=\"2733\" data-end=\"2736\"\u003eChemical industry for refractive index measurement\u003cbr data-start=\"2786\" data-end=\"2789\"\u003eFood and sugar industry for Brix and concentration analysis\u003cbr data-start=\"2848\" data-end=\"2851\"\u003ePetroleum and petrochemical laboratories\u003cbr data-start=\"2891\" data-end=\"2894\"\u003eResearch and academic laboratories\u003c\/p\u003e","brand":"Labman","offers":[{"title":"Default Title","offer_id":49926290374893,"sku":null,"price":551000.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5672\/6765\/files\/RFM100CFR.webp?v=1778791861"},{"product_id":"abbe-refractometer-lmar1317t-1-30000-1-72000-nd-0-100-brix-touch-screen","title":"ABBE Refractometer LMAR1317T (1.30000–1.72000 nD, 0–100% Brix, Touch Screen)","description":"\u003cp data-start=\"307\" data-end=\"1273\"\u003eThe ABBE Refractometer LMAR1317T is a high-precision instrument designed for measuring refractive index and Brix values of transparent and translucent liquids as well as solid samples. The system uses an advanced optical measurement principle combined with a microprocessor-based control system to ensure accurate and stable results. It features a touchscreen interface for simplified operation and real-time data display. The instrument supports automatic temperature correction, improving measurement reliability across varying conditions. With a wide temperature operating range and high-resolution detection, it is suitable for demanding laboratory environments. The integrated LED light source at 589 nm ensures consistent illumination, while the hard glass prism enhances durability and measurement stability. This refractometer is widely used in pharmaceutical, chemical, food, sugar, and research laboratories for quality control and analytical applications.\u003c\/p\u003e\n\u003ch3 data-start=\"1275\" data-end=\"1292\"\u003eKey Features\u003c\/h3\u003e\n\u003cp data-start=\"1293\" data-end=\"1759\"\u003eTouchscreen colour display for easy operation\u003cbr data-start=\"1338\" data-end=\"1341\"\u003eHigh precision refractive index measurement with 5 digit resolution\u003cbr data-start=\"1408\" data-end=\"1411\"\u003eWide measurement range for refractive index and Brix\u003cbr data-start=\"1463\" data-end=\"1466\"\u003eAutomatic temperature correction for accurate results\u003cbr data-start=\"1519\" data-end=\"1522\"\u003eIntegrated LED light source at 589 nm wavelength\u003cbr data-start=\"1570\" data-end=\"1573\"\u003eHard glass prism for durability and stable readings\u003cbr data-start=\"1624\" data-end=\"1627\"\u003eFully automatic measurement system\u003cbr data-start=\"1661\" data-end=\"1664\"\u003eSuitable for transparent and translucent samples\u003cbr data-start=\"1712\" data-end=\"1715\"\u003eInternal memory storage for data recording\u003c\/p\u003e\n\u003ch3 data-start=\"1761\" data-end=\"1790\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"1792\" data-end=\"2367\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"1792\" data-end=\"1817\"\u003e\n\u003ctr data-start=\"1792\" data-end=\"1817\"\u003e\n\u003cth data-start=\"1792\" data-end=\"1804\" data-col-size=\"sm\" class=\"\"\u003eParameter\u003c\/th\u003e\n\u003cth data-start=\"1804\" data-end=\"1817\" data-col-size=\"sm\" class=\"\"\u003eLMAR1317T\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"1843\" data-end=\"2367\"\u003e\n\u003ctr data-start=\"1843\" data-end=\"1892\"\u003e\n\u003ctd data-start=\"1843\" data-end=\"1868\" data-col-size=\"sm\"\u003eRefractive Index Range\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1868\" data-end=\"1892\"\u003e1.30000 – 1.72000 nD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1893\" data-end=\"1918\"\u003e\n\u003ctd data-start=\"1893\" data-end=\"1906\" data-col-size=\"sm\"\u003eBrix Range\u003c\/td\u003e\n\u003ctd data-start=\"1906\" data-end=\"1918\" data-col-size=\"sm\"\u003e0 – 100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1919\" data-end=\"1959\"\u003e\n\u003ctd data-start=\"1919\" data-end=\"1947\" data-col-size=\"sm\"\u003eRefractive Index Accuracy\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1947\" data-end=\"1959\"\u003e±0.00002\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1960\" data-end=\"1985\"\u003e\n\u003ctd data-start=\"1960\" data-end=\"1976\" data-col-size=\"sm\"\u003eBrix Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"1976\" data-end=\"1985\" data-col-size=\"sm\"\u003e±0.1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1986\" data-end=\"2027\"\u003e\n\u003ctd data-start=\"1986\" data-end=\"2016\" data-col-size=\"sm\"\u003eRefractive Index Resolution\u003c\/td\u003e\n\u003ctd data-start=\"2016\" data-end=\"2027\" data-col-size=\"sm\"\u003e0.00001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2028\" data-end=\"2055\"\u003e\n\u003ctd data-start=\"2028\" data-end=\"2046\" data-col-size=\"sm\"\u003eBrix Resolution\u003c\/td\u003e\n\u003ctd data-start=\"2046\" data-end=\"2055\" data-col-size=\"sm\"\u003e0.01%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2056\" data-end=\"2095\"\u003e\n\u003ctd data-start=\"2056\" data-end=\"2076\" data-col-size=\"sm\"\u003eTemperature Range\u003c\/td\u003e\n\u003ctd data-start=\"2076\" data-end=\"2095\" data-col-size=\"sm\"\u003e-20°C to +120°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2096\" data-end=\"2130\"\u003e\n\u003ctd data-start=\"2096\" data-end=\"2121\" data-col-size=\"sm\"\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd data-start=\"2121\" data-end=\"2130\" data-col-size=\"sm\"\u003e0.1°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2131\" data-end=\"2163\"\u003e\n\u003ctd data-start=\"2131\" data-end=\"2141\" data-col-size=\"sm\"\u003eDisplay\u003c\/td\u003e\n\u003ctd data-start=\"2141\" data-end=\"2163\" data-col-size=\"sm\"\u003eColour Touchscreen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2164\" data-end=\"2191\"\u003e\n\u003ctd data-start=\"2164\" data-end=\"2176\" data-col-size=\"sm\"\u003eInterface\u003c\/td\u003e\n\u003ctd data-start=\"2176\" data-end=\"2191\" data-col-size=\"sm\"\u003eRS232C, USB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2192\" data-end=\"2224\"\u003e\n\u003ctd data-start=\"2192\" data-end=\"2207\" data-col-size=\"sm\"\u003eData Storage\u003c\/td\u003e\n\u003ctd data-start=\"2207\" data-end=\"2224\" data-col-size=\"sm\"\u003e500 data sets\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2225\" data-end=\"2252\"\u003e\n\u003ctd data-start=\"2225\" data-end=\"2244\" data-col-size=\"sm\"\u003eProtection Grade\u003c\/td\u003e\n\u003ctd data-start=\"2244\" data-end=\"2252\" data-col-size=\"sm\"\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2253\" data-end=\"2268\"\u003e\n\u003ctd data-start=\"2253\" data-end=\"2261\" data-col-size=\"sm\"\u003ePower\u003c\/td\u003e\n\u003ctd data-start=\"2261\" data-end=\"2268\" data-col-size=\"sm\"\u003e30W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2269\" data-end=\"2304\"\u003e\n\u003ctd data-start=\"2269\" data-end=\"2284\" data-col-size=\"sm\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd data-start=\"2284\" data-end=\"2304\" data-col-size=\"sm\"\u003eAC 220V, 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2305\" data-end=\"2348\"\u003e\n\u003ctd data-start=\"2305\" data-end=\"2326\" data-col-size=\"sm\"\u003eDimensions (L×W×H)\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2326\" data-end=\"2348\"\u003e365 × 245 × 455 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2349\" data-end=\"2367\"\u003e\n\u003ctd data-start=\"2349\" data-end=\"2358\" data-col-size=\"sm\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-start=\"2358\" data-end=\"2367\" data-col-size=\"sm\"\u003e10 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 data-start=\"2369\" data-end=\"2386\"\u003eApplications\u003c\/h3\u003e\n\u003cp data-start=\"2387\" data-end=\"2651\"\u003ePharmaceutical industry for formulation and quality control\u003cbr data-start=\"2446\" data-end=\"2449\"\u003eChemical industry for refractive index analysis\u003cbr data-start=\"2496\" data-end=\"2499\"\u003eFood and sugar industry for Brix and concentration measurement\u003cbr data-start=\"2561\" data-end=\"2564\"\u003ePetroleum and petrochemical testing laboratories\u003cbr data-start=\"2612\" data-end=\"2615\"\u003eAcademic and research laboratories\u003c\/p\u003e","brand":"Labman","offers":[{"title":"Default Title","offer_id":49926341460205,"sku":null,"price":155000.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5672\/6765\/files\/LMAR1317T_b8077547-0248-41d9-b2b1-53777021c9b6.webp?v=1780689042"},{"product_id":"abbe-refractometer-lmar1317-1-3000-1-7000-nd-0-100-brix-lcd-display","title":"ABBE Refractometer LMAR1317 (1.3000–1.7000 nD, 0–100% Brix, LCD Display)","description":"\u003cp data-start=\"282\" data-end=\"1107\"\u003eThe ABBE Refractometer LMAR1317 is a reliable and precise instrument designed for measuring refractive index and Brix values of transparent and translucent liquids as well as solid samples. The system operates on an optical measurement principle using a high-quality hard glass prism to ensure stable and repeatable readings. It features an LCD display with visual aiming for easy observation and measurement. The instrument includes automatic temperature correction to minimize errors caused by temperature variations, ensuring consistent results. With a compact design and simple operation, it is well suited for routine laboratory analysis. The LMAR1317 also supports direct data output through an RS232 interface, making it suitable for documentation and quality control processes in industrial and research laboratories.\u003c\/p\u003e\n\u003ch3 data-start=\"1109\" data-end=\"1126\"\u003eKey Features\u003c\/h3\u003e\n\u003cp data-start=\"1127\" data-end=\"1485\"\u003eMeasurement of refractive index for transparent and translucent samples\u003cbr data-start=\"1198\" data-end=\"1201\"\u003eMeasurement of Brix value for sugar solutions\u003cbr data-start=\"1246\" data-end=\"1249\"\u003eHard glass prism for durability and accuracy\u003cbr data-start=\"1293\" data-end=\"1296\"\u003eLCD display with visual aiming system\u003cbr data-start=\"1333\" data-end=\"1336\"\u003eAutomatic temperature correction for Brix measurement\u003cbr data-start=\"1389\" data-end=\"1392\"\u003eRS232 interface for data output and connectivity\u003cbr data-start=\"1440\" data-end=\"1443\"\u003eSimple operation with stable performance\u003c\/p\u003e\n\u003ch3 data-start=\"1487\" data-end=\"1516\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"1518\" data-end=\"1994\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"1518\" data-end=\"1542\"\u003e\n\u003ctr data-start=\"1518\" data-end=\"1542\"\u003e\n\u003cth data-start=\"1518\" data-end=\"1530\" data-col-size=\"sm\" class=\"\"\u003eParameter\u003c\/th\u003e\n\u003cth data-start=\"1530\" data-end=\"1542\" data-col-size=\"sm\" class=\"\"\u003eLMAR1317\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"1567\" data-end=\"1994\"\u003e\n\u003ctr data-start=\"1567\" data-end=\"1614\"\u003e\n\u003ctd data-start=\"1567\" data-end=\"1592\" data-col-size=\"sm\"\u003eRefractive Index Range\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1592\" data-end=\"1614\"\u003e1.3000 – 1.7000 nD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1615\" data-end=\"1640\"\u003e\n\u003ctd data-start=\"1615\" data-end=\"1628\" data-col-size=\"sm\"\u003eBrix Range\u003c\/td\u003e\n\u003ctd data-start=\"1628\" data-end=\"1640\" data-col-size=\"sm\"\u003e0 – 100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1641\" data-end=\"1682\"\u003e\n\u003ctd data-start=\"1641\" data-end=\"1669\" data-col-size=\"sm\"\u003eRefractive Index Accuracy\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1669\" data-end=\"1682\"\u003e≤ ±0.0002\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1683\" data-end=\"1710\"\u003e\n\u003ctd data-start=\"1683\" data-end=\"1699\" data-col-size=\"sm\"\u003eBrix Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"1699\" data-end=\"1710\" data-col-size=\"sm\"\u003e≤ ±0.1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1711\" data-end=\"1745\"\u003e\n\u003ctd data-start=\"1711\" data-end=\"1736\" data-col-size=\"sm\"\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1736\" data-end=\"1745\"\u003e0.1°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1746\" data-end=\"1778\"\u003e\n\u003ctd data-start=\"1746\" data-end=\"1766\" data-col-size=\"sm\"\u003eTemperature Range\u003c\/td\u003e\n\u003ctd data-start=\"1766\" data-end=\"1778\" data-col-size=\"sm\"\u003e0 – 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1779\" data-end=\"1830\"\u003e\n\u003ctd data-start=\"1779\" data-end=\"1817\" data-col-size=\"sm\"\u003eBrix Temperature Compensation Range\u003c\/td\u003e\n\u003ctd data-start=\"1817\" data-end=\"1830\" data-col-size=\"sm\"\u003e15 – 45°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1831\" data-end=\"1874\"\u003e\n\u003ctd data-start=\"1831\" data-end=\"1855\" data-col-size=\"sm\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd data-start=\"1855\" data-end=\"1874\" data-col-size=\"sm\"\u003eAmbient to 35°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1875\" data-end=\"1897\"\u003e\n\u003ctd data-start=\"1875\" data-end=\"1887\" data-col-size=\"sm\"\u003eInterface\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1887\" data-end=\"1897\"\u003eRS232C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1898\" data-end=\"1931\"\u003e\n\u003ctd data-start=\"1898\" data-end=\"1913\" data-col-size=\"sm\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd data-start=\"1913\" data-end=\"1931\" data-col-size=\"sm\"\u003eAC 220V \/ 50Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1932\" data-end=\"1975\"\u003e\n\u003ctd data-start=\"1932\" data-end=\"1953\" data-col-size=\"sm\"\u003eDimensions (L×W×H)\u003c\/td\u003e\n\u003ctd data-start=\"1953\" data-end=\"1975\" data-col-size=\"sm\"\u003e360 × 250 × 450 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1976\" data-end=\"1994\"\u003e\n\u003ctd data-start=\"1976\" data-end=\"1985\" data-col-size=\"sm\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1985\" data-end=\"1994\"\u003e10 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 data-start=\"1996\" data-end=\"2013\"\u003eApplications\u003c\/h3\u003e\n\u003cp data-start=\"2014\" data-end=\"2285\"\u003ePharmaceutical industry for formulation and quality control\u003cbr data-start=\"2073\" data-end=\"2076\"\u003eFood and sugar industry for Brix measurement and concentration analysis\u003cbr data-start=\"2147\" data-end=\"2150\"\u003eChemical industry for refractive index determination\u003cbr data-start=\"2202\" data-end=\"2205\"\u003ePetrochemical and industrial laboratories\u003cbr data-start=\"2246\" data-end=\"2249\"\u003eAcademic and research laboratories\u003c\/p\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\u003c\/div\u003e","brand":"Labman","offers":[{"title":"Default Title","offer_id":49926342181101,"sku":null,"price":135000.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5672\/6765\/files\/LMAR1317.webp?v=1778871037"}],"url":"https:\/\/www.biotronscientific.com\/collections\/refractometers-polarimeters.oembed","provider":"BIOTRON","version":"1.0","type":"link"}