{"title":"Chromatography Systems (GC\/HPLC)","description":null,"products":[{"product_id":"high-performance-liquid-chromatography-hplc-system-isocratic-hplc1is-and-gradient-hplc2gs","title":"High Performance Liquid Chromatography (HPLC) System – Isocratic (HPLC1IS) and Gradient (HPLC2GS)","description":"\u003cp data-end=\"657\" data-start=\"314\"\u003eHigh Performance Liquid Chromatography (HPLC) systems are designed for accurate separation, identification, and quantification of compounds in complex mixtures. These systems deliver precise solvent control and high reproducibility, making them ideal for pharmaceutical, chemical, and quality control laboratories.\u003c\/p\u003e\n\u003cp data-end=\"813\" data-start=\"659\"\u003e\u003cstrong data-end=\"690\" data-start=\"659\"\u003eHPLC1IS (Isocratic System):\u003c\/strong\u003e A single-pump configuration for constant mobile-phase composition, suitable for routine analyses and standard separations.\u003c\/p\u003e\n\u003cp data-end=\"984\" data-start=\"815\"\u003e\u003cstrong data-end=\"845\" data-start=\"815\"\u003eHPLC2GS (Gradient System):\u003c\/strong\u003e An advanced dual-pump design that allows for gradient elution—enabling changing mobile-phase compositions for complex sample separation.\u003c\/p\u003e\n\u003cp data-end=\"1176\" data-start=\"986\"\u003eBoth systems include a high-performance UV detector and user-friendly control software compliant with GLP\/FDA 21 CFR Part 11, ensuring secure electronic data management and audit compliance.\u003c\/p\u003e\n\u003cp data-end=\"1176\" data-start=\"986\"\u003e\u003cstrong data-end=\"1213\" data-start=\"1183\"\u003eKey Features\u003c\/strong\u003e\u003cbr data-end=\"1216\" data-start=\"1213\"\u003eIsocratic and gradient system configurations for flexible analysis\u003cbr data-end=\"1124\" data-start=\"1121\"\u003eDual plunger high pressure pump for accurate solvent delivery\u003cbr data-end=\"1188\" data-start=\"1185\"\u003eLow pulsation control for stable baseline performance\u003cbr data-end=\"1244\" data-start=\"1241\"\u003eWide flow range from 0.001 to 9.999 ml\/min\u003cbr data-end=\"1289\" data-start=\"1286\"\u003eHigh flow accuracy and repeatability across full range\u003cbr data-end=\"1346\" data-start=\"1343\"\u003eDual wavelength UV detection for enhanced sensitivity\u003cbr data-end=\"1402\" data-start=\"1399\"\u003eAdvanced optical system for improved detection capability\u003cbr data-end=\"1462\" data-start=\"1459\"\u003eOLED display with user-friendly interface\u003cbr data-end=\"1506\" data-start=\"1503\"\u003eProgrammable methods for flow and gradient control\u003cbr data-end=\"1559\" data-start=\"1556\"\u003eElectronic pressure control for consistent performance\u003cbr data-is-only-node=\"\" data-end=\"1616\" data-start=\"1613\"\u003eMulti-mode wavelength scanning with programmable settings\u003cbr data-end=\"1676\" data-start=\"1673\"\u003eSoftware compatibility with regulated data requirements\u003cbr data-end=\"1734\" data-start=\"1731\"\u003eModular design for reliability and long-term operation\u003cbr\u003e\u003c\/p\u003e\n\u003cp data-end=\"1176\" data-start=\"986\"\u003e\u003cstrong\u003eProduct Specification Table\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eHPLC1IS\u003c\/th\u003e\n\u003cth\u003eHPLC2GS\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eIsocratic\u003c\/td\u003e\n\u003ctd\u003eGradient\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow Range\u003c\/td\u003e\n\u003ctd\u003e0.001 – 9.999 ml\/min\u003c\/td\u003e\n\u003ctd\u003e0.001 – 9.999 ml\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.5% or 10 µL\/min\u003c\/td\u003e\n\u003ctd\u003e±0.5% or 10 µL\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow Precision\u003c\/td\u003e\n\u003ctd\u003eRSD ≤ 0.1%\u003c\/td\u003e\n\u003ctd\u003eRSD ≤ 0.1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure Range\u003c\/td\u003e\n\u003ctd\u003e≤ 42 MPa (316L) \/ ≤ 30 MPa (PEEK)\u003c\/td\u003e\n\u003ctd\u003eSame\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow Pulsation\u003c\/td\u003e\n\u003ctd\u003e≤ 0.5%\u003c\/td\u003e\n\u003ctd\u003e≤ 0.5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncrement\u003c\/td\u003e\n\u003ctd\u003e0.001 ml\/min\u003c\/td\u003e\n\u003ctd\u003e0.001 ml\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump Design\u003c\/td\u003e\n\u003ctd\u003eDual plunger in series\u003c\/td\u003e\n\u003ctd\u003eParallel pump system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eOLED\u003c\/td\u003e\n\u003ctd\u003eOLED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl\u003c\/td\u003e\n\u003ctd\u003ePanel \/ Computer control\u003c\/td\u003e\n\u003ctd\u003ePanel \/ Computer control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e75 W\u003c\/td\u003e\n\u003ctd\u003e75 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003eAC 220V, 50\/60 Hz\u003c\/td\u003e\n\u003ctd\u003eAC 220V, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eUV Detector Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection Type\u003c\/td\u003e\n\u003ctd\u003eUV Detector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWavelength Range\u003c\/td\u003e\n\u003ctd\u003e190 – 400 nm (700 nm optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWavelength Accuracy\u003c\/td\u003e\n\u003ctd\u003e1 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWavelength Precision\u003c\/td\u003e\n\u003ctd\u003e±0.1 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncrement\u003c\/td\u003e\n\u003ctd\u003e1 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrift\u003c\/td\u003e\n\u003ctd\u003e≤ 2×10⁻⁴ AU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow Cell Volume\u003c\/td\u003e\n\u003ctd\u003e10 µL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection Range\u003c\/td\u003e\n\u003ctd\u003e0 – 2 AU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLight Source\u003c\/td\u003e\n\u003ctd\u003eDeuterium \/ Halogen (optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eOLED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl\u003c\/td\u003e\n\u003ctd\u003ePanel \/ Computer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e80 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003eAC 220V, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Labman","offers":[{"title":"Isocratic (HPLC1IS)","offer_id":48996228497645,"sku":null,"price":790000.0,"currency_code":"INR","in_stock":true},{"title":"Gradient (HPLC2GS)","offer_id":48996228530413,"sku":null,"price":1065000.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5672\/6765\/files\/HPLC1IS.jpg?v=1776624161"},{"product_id":"gas-chromatography-system-gc10ci-fid-programmable-oven-capillary-injector","title":"Gas Chromatography System GC10CI (FID, Programmable Oven, Capillary Injector)","description":"\u003cp data-start=\"286\" data-end=\"1083\"\u003eGas Chromatography System GC10CI is designed for high-precision separation and analysis of volatile and semi-volatile compounds in analytical laboratories. The system integrates a programmable column oven with multistage temperature ramping, enabling accurate control of thermal conditions for complex sample separation. It features a high-sensitivity Flame Ionization Detector (FID) for reliable detection of organic compounds with excellent stability and linearity. The capillary injection system ensures efficient sample introduction, while the advanced computer-based control system supports real-time monitoring, data acquisition and method programming. The system is suitable for routine and advanced chromatography workflows requiring accuracy, repeatability and compliance-ready operation.\u003c\/p\u003e\n\u003ch3 data-start=\"1085\" data-end=\"1102\"\u003eKey Features\u003c\/h3\u003e\n\u003cp data-start=\"1103\" data-end=\"1779\"\u003eProgrammable column oven with multi-stage temperature ramp control\u003cbr data-start=\"1169\" data-end=\"1172\"\u003eHigh sensitivity FID detector for organic compound analysis\u003cbr data-start=\"1231\" data-end=\"1234\"\u003eCapillary injector for precise sample introduction\u003cbr data-start=\"1284\" data-end=\"1287\"\u003eFast heating and rapid cooling oven design\u003cbr data-start=\"1329\" data-end=\"1332\"\u003eAdvanced data acquisition with real-time monitoring\u003cbr data-start=\"1383\" data-end=\"1386\"\u003eComputer-based control system with software integration\u003cbr data-start=\"1441\" data-end=\"1444\"\u003eHigh temperature accuracy with stable thermal performance\u003cbr data-start=\"1501\" data-end=\"1504\"\u003eSupports up to 10 temperature ramps with software control\u003cbr data-start=\"1561\" data-end=\"1564\"\u003eAnalog signal output for external integration\u003cbr data-start=\"1609\" data-end=\"1612\"\u003eSelf-diagnostic and protection functions for safe operation\u003cbr data-start=\"1671\" data-end=\"1674\"\u003eCompatible with regulatory-compliant data systems\u003cbr data-start=\"1723\" data-end=\"1726\"\u003eSupports headspace and thermal analysis accessories\u003c\/p\u003e\n\u003ch3 data-start=\"1781\" data-end=\"1810\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSample Introduction\u003c\/td\u003e\n\u003ctd\u003eCapillary Injector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetector Type\u003c\/td\u003e\n\u003ctd\u003eFID\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003eRT +7°C to 400°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.02°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Time\u003c\/td\u003e\n\u003ctd\u003e400°C to 50°C in 8–10 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Program Rate\u003c\/td\u003e\n\u003ctd\u003e0.1°C to 40°C\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProgram Ramps\u003c\/td\u003e\n\u003ctd\u003e7 standard (up to 10 with software)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection Limit\u003c\/td\u003e\n\u003ctd\u003e≤3×10⁻¹² g\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrift\u003c\/td\u003e\n\u003ctd\u003e≤6×10⁻¹³ A\/30 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinearity Range\u003c\/td\u003e\n\u003ctd\u003e≥10⁶\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInner Dimensions (L×W×H)\u003c\/td\u003e\n\u003ctd\u003e284 × 280 × 241 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOuter Dimensions (L×W×H)\u003c\/td\u003e\n\u003ctd\u003e340 × 345 × 281 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e2000 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e220V \/ 50Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePacking Dimensions\u003c\/td\u003e\n\u003ctd\u003e830 × 680 × 855 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 79 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Labman","offers":[{"title":"Default Title","offer_id":49800356659437,"sku":null,"price":500000.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5672\/6765\/files\/GC10CI.jpg?v=1776625590"},{"product_id":"gas-chromatography-system-gc99si-epc-fid-split-splitless-injector","title":"Gas Chromatography System GC99SI (EPC, FID, Split\/Splitless Injector)","description":"\u003cp data-start=\"276\" data-end=\"1064\"\u003eGas Chromatography System GC99SI is a high-performance analytical instrument designed for precise separation and detection of volatile and semi-volatile compounds. It features an Electronic Pneumatic Control (EPC) system for accurate gas flow management, ensuring stable and reproducible results. The system includes a programmable column oven with multi-stage temperature ramping, enabling efficient separation of complex samples. Equipped with a high-sensitivity Flame Ionization Detector (FID) and split\/splitless injection system, it delivers excellent detection capability and flexibility. The integrated touchscreen interface and computer-based control system allow real-time monitoring, method programming and data acquisition, making it suitable for advanced laboratory workflows.\u003c\/p\u003e\n\u003ch3 data-start=\"1066\" data-end=\"1083\"\u003eKey Features\u003c\/h3\u003e\n\u003cp data-start=\"1084\" data-end=\"1772\"\u003eElectronic pneumatic control system for precise gas flow regulation\u003cbr data-start=\"1151\" data-end=\"1154\"\u003eSplit and splitless injector for flexible sample introduction\u003cbr data-start=\"1215\" data-end=\"1218\"\u003eHigh sensitivity FID detector for organic compound analysis\u003cbr data-start=\"1277\" data-end=\"1280\"\u003eProgrammable column oven with multi-stage temperature ramps\u003cbr data-start=\"1339\" data-end=\"1342\"\u003eSupports up to 20 ramps (99 with software control)\u003cbr data-start=\"1392\" data-end=\"1395\"\u003eFast heating and rapid cooling oven performance\u003cbr data-start=\"1442\" data-end=\"1445\"\u003e7 inch touchscreen display for intuitive operation\u003cbr data-start=\"1495\" data-end=\"1498\"\u003eAdvanced data acquisition with real-time monitoring\u003cbr data-start=\"1549\" data-end=\"1552\"\u003eHigh temperature accuracy and stability\u003cbr data-start=\"1591\" data-end=\"1594\"\u003eCompatible with computer-based control and analysis software\u003cbr data-start=\"1654\" data-end=\"1657\"\u003eSelf-diagnostic and protection functions for safe operation\u003cbr data-start=\"1716\" data-end=\"1719\"\u003eSupports headspace and thermal analysis accessories\u003c\/p\u003e\n\u003ch3 data-start=\"1774\" data-end=\"1803\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"1804\" data-end=\"2582\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"1804\" data-end=\"1833\"\u003e\n\u003ctr data-start=\"1804\" data-end=\"1833\"\u003e\n\u003cth data-start=\"1804\" data-end=\"1816\" data-col-size=\"sm\" class=\"\"\u003eParameter\u003c\/th\u003e\n\u003cth data-start=\"1816\" data-end=\"1833\" data-col-size=\"md\" class=\"\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"1844\" data-end=\"2582\"\u003e\n\u003ctr data-start=\"1844\" data-end=\"1899\"\u003e\n\u003ctd data-start=\"1844\" data-end=\"1861\" data-col-size=\"sm\"\u003eControl System\u003c\/td\u003e\n\u003ctd data-start=\"1861\" data-end=\"1899\" data-col-size=\"md\"\u003eEPC (Electronic Pneumatic Control)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1900\" data-end=\"1933\"\u003e\n\u003ctd data-start=\"1900\" data-end=\"1910\" data-col-size=\"sm\"\u003eDisplay\u003c\/td\u003e\n\u003ctd data-start=\"1910\" data-end=\"1933\" data-col-size=\"md\"\u003e7 inch Touch Screen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1934\" data-end=\"1983\"\u003e\n\u003ctd data-start=\"1934\" data-end=\"1953\" data-col-size=\"sm\"\u003eInjection System\u003c\/td\u003e\n\u003ctd data-start=\"1953\" data-end=\"1983\" data-col-size=\"md\"\u003eSplit \/ Splitless Injector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1984\" data-end=\"2007\"\u003e\n\u003ctd data-start=\"1984\" data-end=\"2000\" data-col-size=\"sm\"\u003eDetector Type\u003c\/td\u003e\n\u003ctd data-start=\"2000\" data-end=\"2007\" data-col-size=\"md\"\u003eFID\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2008\" data-end=\"2048\"\u003e\n\u003ctd data-start=\"2008\" data-end=\"2028\" data-col-size=\"sm\"\u003eTemperature Range\u003c\/td\u003e\n\u003ctd data-start=\"2028\" data-end=\"2048\" data-col-size=\"md\"\u003eRT +7°C to 420°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2049\" data-end=\"2083\"\u003e\n\u003ctd data-start=\"2049\" data-end=\"2072\" data-col-size=\"sm\"\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"2072\" data-end=\"2083\" data-col-size=\"md\"\u003e±0.02°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2084\" data-end=\"2151\"\u003e\n\u003ctd data-start=\"2084\" data-end=\"2099\" data-col-size=\"sm\"\u003eCooling Time\u003c\/td\u003e\n\u003ctd data-start=\"2099\" data-end=\"2151\" data-col-size=\"md\"\u003e350°C to 100°C ≤3 min, 400°C to 50°C in 8–10 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2152\" data-end=\"2200\"\u003e\n\u003ctd data-start=\"2152\" data-end=\"2179\" data-col-size=\"sm\"\u003eTemperature Program Rate\u003c\/td\u003e\n\u003ctd data-start=\"2179\" data-end=\"2200\" data-col-size=\"md\"\u003e0.1°C to 80°C\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2201\" data-end=\"2257\"\u003e\n\u003ctd data-start=\"2201\" data-end=\"2217\" data-col-size=\"sm\"\u003eProgram Ramps\u003c\/td\u003e\n\u003ctd data-start=\"2217\" data-end=\"2257\" data-col-size=\"md\"\u003e20 standard (up to 99 with software)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2258\" data-end=\"2307\"\u003e\n\u003ctd data-start=\"2258\" data-end=\"2276\" data-col-size=\"sm\"\u003eDetection Limit\u003c\/td\u003e\n\u003ctd data-start=\"2276\" data-end=\"2307\" data-col-size=\"md\"\u003e≤8×10⁻¹² g\/s (n-hexadecane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2308\" data-end=\"2334\"\u003e\n\u003ctd data-start=\"2308\" data-end=\"2316\" data-col-size=\"sm\"\u003eDrift\u003c\/td\u003e\n\u003ctd data-start=\"2316\" data-end=\"2334\" data-col-size=\"md\"\u003e≤1.5×10⁻¹³ A\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2335\" data-end=\"2361\"\u003e\n\u003ctd data-start=\"2335\" data-end=\"2353\" data-col-size=\"sm\"\u003eLinearity Range\u003c\/td\u003e\n\u003ctd data-start=\"2353\" data-end=\"2361\" data-col-size=\"md\"\u003e≥10⁶\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2362\" data-end=\"2411\"\u003e\n\u003ctd data-start=\"2362\" data-end=\"2389\" data-col-size=\"sm\"\u003eInner Dimensions (L×W×H)\u003c\/td\u003e\n\u003ctd data-start=\"2389\" data-end=\"2411\" data-col-size=\"md\"\u003e284 × 280 × 241 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2412\" data-end=\"2461\"\u003e\n\u003ctd data-start=\"2412\" data-end=\"2439\" data-col-size=\"sm\"\u003eOuter Dimensions (L×W×H)\u003c\/td\u003e\n\u003ctd data-start=\"2439\" data-end=\"2461\" data-col-size=\"md\"\u003e340 × 345 × 281 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2462\" data-end=\"2480\"\u003e\n\u003ctd data-start=\"2462\" data-end=\"2470\" data-col-size=\"sm\"\u003ePower\u003c\/td\u003e\n\u003ctd data-start=\"2470\" data-end=\"2480\" data-col-size=\"md\"\u003e2000 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2481\" data-end=\"2511\"\u003e\n\u003ctd data-start=\"2481\" data-end=\"2496\" data-col-size=\"sm\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd data-start=\"2496\" data-end=\"2511\" data-col-size=\"md\"\u003e220V \/ 50Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2512\" data-end=\"2555\"\u003e\n\u003ctd data-start=\"2512\" data-end=\"2533\" data-col-size=\"sm\"\u003ePacking Dimensions\u003c\/td\u003e\n\u003ctd data-start=\"2533\" data-end=\"2555\" data-col-size=\"md\"\u003e835 × 770 × 930 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2556\" data-end=\"2582\"\u003e\n\u003ctd data-start=\"2556\" data-end=\"2565\" data-col-size=\"sm\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-start=\"2565\" data-end=\"2582\" data-col-size=\"md\"\u003eApprox. 88 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Labman","offers":[{"title":"Default Title","offer_id":49822333567213,"sku":null,"price":850000.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5672\/6765\/files\/GC99SI.jpg?v=1776974059"},{"product_id":"autosampler-for-gas-chromatography-asgc22-0-1-250-µl-22-vial-tray","title":"Autosampler for Gas Chromatography ASGC22 (0.1–250 µL, 22 Vial Tray)","description":"\u003cp data-start=\"281\" data-end=\"870\"\u003eAutosampler ASGC22 is designed to automate sample injection in gas chromatography systems, improving precision, repeatability and workflow efficiency. It enables unattended operation with programmable injection sequences, ensuring consistent injection volumes and reduced manual error. The system features a multi-position vial tray, flexible injection modes and adjustable speed control for accurate sample handling. With touchscreen interface, barcode support and communication compatibility, it integrates seamlessly with GC systems for routine and high-throughput analytical workflows.\u003c\/p\u003e\n\u003ch3 data-start=\"872\" data-end=\"889\"\u003eKey Features\u003c\/h3\u003e\n\u003cp data-start=\"890\" data-end=\"1530\"\u003eAutomated sample injection for improved reproducibility\u003cbr data-start=\"945\" data-end=\"948\"\u003eInjection volume range from 0.1 µL to 250 µL\u003cbr data-start=\"992\" data-end=\"995\"\u003eMulti-position sample tray for high-throughput operation\u003cbr data-start=\"1051\" data-end=\"1054\"\u003eProgrammable injection sequences with multiple methods\u003cbr data-start=\"1108\" data-end=\"1111\"\u003eAdjustable needle speed and injection modes\u003cbr data-start=\"1154\" data-end=\"1157\"\u003eHigh precision syringe control for accurate volume delivery\u003cbr data-start=\"1216\" data-end=\"1219\"\u003eTouchscreen interface for easy operation and monitoring\u003cbr data-start=\"1274\" data-end=\"1277\"\u003eSupports barcode scanning and sample tracking\u003cbr data-start=\"1322\" data-end=\"1325\"\u003eContinuous and normal injection modes for flexibility\u003cbr data-start=\"1378\" data-end=\"1381\"\u003eLow carryover design with multiple needle cleaning cycles\u003cbr data-start=\"1438\" data-end=\"1441\"\u003eCompatible with GC software control systems\u003cbr data-start=\"1484\" data-end=\"1487\"\u003eSupports long unattended operation cycles\u003c\/p\u003e\n\u003ch3 data-start=\"1532\" data-end=\"1561\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"1562\" data-end=\"2425\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"1562\" data-end=\"1591\"\u003e\n\u003ctr data-start=\"1562\" data-end=\"1591\"\u003e\n\u003cth data-start=\"1562\" data-end=\"1574\" data-col-size=\"sm\" class=\"\"\u003eParameter\u003c\/th\u003e\n\u003cth data-start=\"1574\" data-end=\"1591\" data-col-size=\"md\" class=\"\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"1602\" data-end=\"2425\"\u003e\n\u003ctr data-start=\"1602\" data-end=\"1637\"\u003e\n\u003ctd data-start=\"1602\" data-end=\"1619\" data-col-size=\"sm\"\u003eEquipment Type\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"1619\" data-end=\"1637\"\u003eGC Autosampler\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1638\" data-end=\"1656\"\u003e\n\u003ctd data-start=\"1638\" data-end=\"1646\" data-col-size=\"sm\"\u003eModel\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"1646\" data-end=\"1656\"\u003eASGC22\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1657\" data-end=\"1701\"\u003e\n\u003ctd data-start=\"1657\" data-end=\"1682\" data-col-size=\"sm\"\u003eInjection Volume Range\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"1682\" data-end=\"1701\"\u003e0.1 µL – 250 µL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1702\" data-end=\"1758\"\u003e\n\u003ctd data-start=\"1702\" data-end=\"1720\" data-col-size=\"sm\"\u003eSyringe Options\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"1720\" data-end=\"1758\"\u003e1, 5, 10, 25, 50, 100, 250, 500 µL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1759\" data-end=\"1798\"\u003e\n\u003ctd data-start=\"1759\" data-end=\"1782\" data-col-size=\"sm\"\u003eSample Tray Capacity\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"1782\" data-end=\"1798\"\u003e22 positions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1799\" data-end=\"1820\"\u003e\n\u003ctd data-start=\"1799\" data-end=\"1814\" data-col-size=\"sm\"\u003eSample Vials\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"1814\" data-end=\"1820\"\u003e19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1821\" data-end=\"1842\"\u003e\n\u003ctd data-start=\"1821\" data-end=\"1837\" data-col-size=\"sm\"\u003eSolvent Vials\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"1837\" data-end=\"1842\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1843\" data-end=\"1861\"\u003e\n\u003ctd data-start=\"1843\" data-end=\"1856\" data-col-size=\"sm\"\u003eWaste Vial\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"1856\" data-end=\"1861\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1862\" data-end=\"1898\"\u003e\n\u003ctd data-start=\"1862\" data-end=\"1882\" data-col-size=\"sm\"\u003eInjection Repeats\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"1882\" data-end=\"1898\"\u003e1 – 99 times\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1899\" data-end=\"1929\"\u003e\n\u003ctd data-start=\"1899\" data-end=\"1918\" data-col-size=\"sm\"\u003eMaximum Interval\u003c\/td\u003e\n\u003ctd data-start=\"1918\" data-end=\"1929\" data-col-size=\"md\"\u003e999 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1930\" data-end=\"1950\"\u003e\n\u003ctd data-start=\"1930\" data-end=\"1940\" data-col-size=\"sm\"\u003eMethods\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"1940\" data-end=\"1950\"\u003e1 – 20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1951\" data-end=\"1994\"\u003e\n\u003ctd data-start=\"1951\" data-end=\"1976\" data-col-size=\"sm\"\u003eNeedle Cleaning Cycles\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"1976\" data-end=\"1994\"\u003eUp to 99 times\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1995\" data-end=\"2031\"\u003e\n\u003ctd data-start=\"1995\" data-end=\"2014\" data-col-size=\"sm\"\u003ePumping Interval\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2014\" data-end=\"2031\"\u003eUp to 5000 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2032\" data-end=\"2062\"\u003e\n\u003ctd data-start=\"2032\" data-end=\"2050\" data-col-size=\"sm\"\u003eViscosity Delay\u003c\/td\u003e\n\u003ctd data-start=\"2050\" data-end=\"2062\" data-col-size=\"md\"\u003e0 – 60 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2063\" data-end=\"2089\"\u003e\n\u003ctd data-start=\"2063\" data-end=\"2076\" data-col-size=\"sm\"\u003eDwell Time\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2076\" data-end=\"2089\"\u003e0 – 120 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2090\" data-end=\"2131\"\u003e\n\u003ctd data-start=\"2090\" data-end=\"2108\" data-col-size=\"sm\"\u003eInjection Modes\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2108\" data-end=\"2131\"\u003eNormal \/ Continuous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2132\" data-end=\"2177\"\u003e\n\u003ctd data-start=\"2132\" data-end=\"2147\" data-col-size=\"sm\"\u003eNeedle Speed\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2147\" data-end=\"2177\"\u003eFast \/ Slow \/ User-defined\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2178\" data-end=\"2216\"\u003e\n\u003ctd data-start=\"2178\" data-end=\"2193\" data-col-size=\"sm\"\u003eControl Mode\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2193\" data-end=\"2216\"\u003eGC software control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2217\" data-end=\"2253\"\u003e\n\u003ctd data-start=\"2217\" data-end=\"2232\" data-col-size=\"sm\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2232\" data-end=\"2253\"\u003eAC 220V, 50–60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2254\" data-end=\"2289\"\u003e\n\u003ctd data-start=\"2254\" data-end=\"2267\" data-col-size=\"sm\"\u003eDimensions\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2267\" data-end=\"2289\"\u003e620 × 325 × 280 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2290\" data-end=\"2315\"\u003e\n\u003ctd data-start=\"2290\" data-end=\"2299\" data-col-size=\"sm\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-start=\"2299\" data-end=\"2315\" data-col-size=\"md\"\u003eApprox. 6 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2316\" data-end=\"2363\"\u003e\n\u003ctd data-start=\"2316\" data-end=\"2330\" data-col-size=\"sm\"\u003eApplication\u003c\/td\u003e\n\u003ctd data-start=\"2330\" data-end=\"2363\" data-col-size=\"md\"\u003eAutomated GC sample injection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2364\" data-end=\"2425\"\u003e\n\u003ctd data-start=\"2364\" data-end=\"2372\" data-col-size=\"sm\"\u003eUsage\u003c\/td\u003e\n\u003ctd data-start=\"2372\" data-end=\"2425\" data-col-size=\"md\"\u003eAnalytical laboratories, chromatography workflows\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Labman","offers":[{"title":"Default Title","offer_id":49822367056109,"sku":null,"price":450000.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5672\/6765\/files\/ASGC22.jpg?v=1776974426"},{"product_id":"column-oven-lmc01-pid-temperature-control-40-c-to-80-c-range","title":"Column Oven LMC01 (PID Temperature Control, 40°C to 80°C Range)","description":"\u003cp data-start=\"260\" data-end=\"620\"\u003eColumn Oven LMC01 is a compact laboratory heating system designed for precise temperature control of analytical and protective columns used in HPLC and chromatography applications. The oven provides stable and uniform heating conditions to improve analytical consistency, peak reproducibility, and separation efficiency during routine chromatographic analysis.\u003c\/p\u003e\n\u003cp data-start=\"622\" data-end=\"921\"\u003eThe unit features PID-based self-tuning temperature control with real-time temperature indication for accurate and stable thermal regulation. Its integrated LCD display provides clear visibility of both set and actual temperature values, enabling convenient operation and monitoring during analysis.\u003c\/p\u003e\n\u003cp data-start=\"923\" data-end=\"1213\"\u003eLMC01 is equipped with a three-slot double column base capable of accommodating analytical and protective columns up to 340 mm in length. The compact chamber design ensures efficient heat distribution while maintaining stable operating conditions for sensitive chromatographic applications.\u003c\/p\u003e\n\u003cp data-start=\"1215\" data-end=\"1455\"\u003eThe oven supports temperature setting and control operation through a user-friendly interface with dedicated adjustment keys. Its integral thickened alloy structure enhances durability and operational stability for long-term laboratory use.\u003c\/p\u003e\n\u003cp data-start=\"1457\" data-end=\"1680\"\u003eDesigned for HPLC laboratories, analytical research facilities, pharmaceutical testing, and chemical analysis applications, the LMC01 provides reliable column temperature management for improved chromatographic performance.\u003c\/p\u003e\n\u003ch3 data-start=\"1682\" data-end=\"1697\"\u003eKey Features\u003c\/h3\u003e\n\u003cp data-start=\"1699\" data-end=\"2154\"\u003ePID self-tuning temperature control system\u003cbr data-start=\"1741\" data-end=\"1744\"\u003eReal-time temperature indication\u003cbr data-start=\"1776\" data-end=\"1779\"\u003eLarge white LCD display\u003cbr data-start=\"1802\" data-end=\"1805\"\u003eStable chamber heating performance\u003cbr data-start=\"1839\" data-end=\"1842\"\u003eTemperature range from RT+5°C to 80°C\u003cbr data-start=\"1879\" data-end=\"1882\"\u003eThree-slot double column base\u003cbr data-start=\"1911\" data-end=\"1914\"\u003eSupports columns up to 340 mm length\u003cbr data-start=\"1950\" data-end=\"1953\"\u003eCompact and durable alloy construction\u003cbr data-start=\"1991\" data-end=\"1994\"\u003eUser-friendly temperature control interface\u003cbr data-start=\"2037\" data-end=\"2040\"\u003eSuitable for HPLC analytical applications\u003cbr data-start=\"2081\" data-end=\"2084\"\u003eUniform and reliable temperature regulation\u003cbr data-start=\"2127\" data-end=\"2130\"\u003eCompact bench-top design\u003c\/p\u003e\n\u003ch3 data-start=\"2156\" data-end=\"2183\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"2185\" data-end=\"2510\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"2185\" data-end=\"2214\"\u003e\n\u003ctr data-start=\"2185\" data-end=\"2214\"\u003e\n\u003cth data-start=\"2185\" data-end=\"2197\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth data-start=\"2197\" data-end=\"2214\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"2229\" data-end=\"2510\"\u003e\n\u003ctr data-start=\"2229\" data-end=\"2267\"\u003e\n\u003ctd data-start=\"2229\" data-end=\"2249\" data-col-size=\"sm\"\u003eTemperature Range\u003c\/td\u003e\n\u003ctd data-start=\"2249\" data-end=\"2267\" data-col-size=\"sm\"\u003eRT+5°C to 80°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2268\" data-end=\"2309\"\u003e\n\u003ctd data-start=\"2268\" data-end=\"2300\" data-col-size=\"sm\"\u003eConstant Temperature Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"2300\" data-end=\"2309\" data-col-size=\"sm\"\u003e0.1°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2310\" data-end=\"2353\"\u003e\n\u003ctd data-start=\"2310\" data-end=\"2333\" data-col-size=\"sm\"\u003eChamber Size (L×W×H)\u003c\/td\u003e\n\u003ctd data-start=\"2333\" data-end=\"2353\" data-col-size=\"sm\"\u003e80 × 38 × 400 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2354\" data-end=\"2388\"\u003e\n\u003ctd data-start=\"2354\" data-end=\"2378\" data-col-size=\"sm\"\u003eMaximum Column Length\u003c\/td\u003e\n\u003ctd data-start=\"2378\" data-end=\"2388\" data-col-size=\"sm\"\u003e340 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2389\" data-end=\"2414\"\u003e\n\u003ctd data-start=\"2389\" data-end=\"2405\" data-col-size=\"sm\"\u003ePower Wattage\u003c\/td\u003e\n\u003ctd data-start=\"2405\" data-end=\"2414\" data-col-size=\"sm\"\u003e120 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2415\" data-end=\"2448\"\u003e\n\u003ctd data-start=\"2415\" data-end=\"2430\" data-col-size=\"sm\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd data-start=\"2430\" data-end=\"2448\" data-col-size=\"sm\"\u003eAC 220V \/ 50Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2449\" data-end=\"2492\"\u003e\n\u003ctd data-start=\"2449\" data-end=\"2470\" data-col-size=\"sm\"\u003eDimensions (L×W×H)\u003c\/td\u003e\n\u003ctd data-start=\"2470\" data-end=\"2492\" data-col-size=\"sm\"\u003e550 × 210 × 215 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2493\" data-end=\"2510\"\u003e\n\u003ctd data-start=\"2493\" data-end=\"2502\" data-col-size=\"sm\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-start=\"2502\" data-end=\"2510\" data-col-size=\"sm\"\u003e3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 data-start=\"2512\" data-end=\"2527\"\u003eApplications\u003c\/h3\u003e\n\u003cp data-start=\"2529\" data-end=\"2762\"\u003eHPLC analytical systems\u003cbr data-start=\"2552\" data-end=\"2555\"\u003eChromatography laboratories\u003cbr data-start=\"2582\" data-end=\"2585\"\u003ePharmaceutical analysis\u003cbr data-start=\"2608\" data-end=\"2611\"\u003eChemical testing laboratories\u003cbr data-start=\"2640\" data-end=\"2643\"\u003eResearch and development laboratories\u003cbr data-start=\"2680\" data-end=\"2683\"\u003eColumn temperature stabilization applications\u003cbr data-start=\"2728\" data-end=\"2731\"\u003eAnalytical separation workflows\u003c\/p\u003e","brand":"Labman","offers":[{"title":"Default Title","offer_id":49973782544621,"sku":null,"price":27500.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/5672\/6765\/files\/LMCO1.jpg?v=1778963921"}],"url":"https:\/\/www.biotronscientific.com\/collections\/chromatography-systems-gc-hplc.oembed","provider":"BIOTRON","version":"1.0","type":"link"}